  • No heat call, found the exhaust vent was tripped due to an overheated draft vent rollout switch. System was rolling out bad, found this to be cause by a clogged up flue pipe. How to fix flame rollout, Come along for the ride.
    Help support the channel. Purchasing tools from my Amazon Store provides a small commission and helps me make more videos like this one.
    amazon.com/shop/nighthawkhvac
    Follow me on Facebook and Instagram
    nighthawkhvac
    nighthawk_hvac
    Intro and Outro Music
    "Alive" by CHOIX
    #nighthawkhvac #hvac, #hvaclife, #airconditioning #maintenance, #heating, #cooling #refrigerator, #refrigeration #refrigerationcycle #airflow #refrigerant #techlife #installation, #hvachacks, #tools, #furnace, #tech, #electric, #residential, #commercial, #heat, #comfort, #ac, #hvacservice, #hvactools, #repair#toolreviews #fieldpiece #aircon #packageunit #rheem #condenserfanmotor #sequencerrelay #flamerollout #bvent #fluepipe #howtofixfurnace #howtofixheater
  • Jak na to + styl

Komentáře • 166

  • @gregsmith9395
    @gregsmith9395 Před 3 lety +31

    I like videos that SHOW the problem. I get tired of videos that just talk without showing. This one shows symptoms very well. Diagnosis steps are shown. You don't just say what you did. Also A-B-A. You showed the problem (A). Showed it fixed with the cap off (B). Then put the cap back on to make it go back to the original bad condition (A) again. You are able to "turn the problem on and off", showing a correct diagnosis.

  • @alexnunez4019
    @alexnunez4019 Před rokem +3

    "Tell me what a horrible technician I am" lmao they do troll hard. Thanks for the video

  • @aaronsmith5433
    @aaronsmith5433 Před rokem +4

    We're too many generations removed from direct hands on fire tending(campfires, coalstoves, woodstoves, etc.)..
    Oldsters generations ago taught us well about giving fire enough air to breath.
    When I was little ,my best friend had a coal fired furnace in the cellar just like in "The Christmas Story" , only his father was friendly with and he spent time teaching us all about tending it properly.
    I still remember the sweet smell.
    That's why coal oven 🍕is heavenly.

  • @Khn83
    @Khn83 Před rokem +5

    Nice detective work… I wager that most techs would have diagnosed as a bad heat exchanger. You went the extra mile and figured out what was making it roll out.
    Nicely done!

  • @ldiazmdiaz
    @ldiazmdiaz Před 3 lety +11

    Do not forget to tell the customer to seal the roof shingle too. Good job on the analyzes.

  • @rickl5938
    @rickl5938 Před 2 lety +24

    Just an FYI. The switch you pointed to is not a rollout switch, it is a blocked vent switch since it is nowhere near the burners. Also, just another FYI, right above the status codes is an explanation of how to decipher the status flashes.The number of short flashes is the first digit and the number of long flashes is the second digit, so, it was displaying a 31 code.

    • @taylormack34
      @taylormack34 Před 2 lety +1

      FYI it was unsafe to run a furnace when the venting is disconnected while testing for a blocked vent. Just spilling the flue gas in the space.

    • @noemiX82
      @noemiX82 Před 8 měsíci +1

      I don’t think the codes goes for all furnaces. Mine it fast flash then slow to read my codes. I have a Payne furnace

    • @keithcress1335
      @keithcress1335 Před 4 měsíci

      Thanks for that Rick. I as scratching my head wondering why the roll-out was 'way over there', while there was obviously one at the top right of the burner inlets.

  • @Ryan-mk8yw
    @Ryan-mk8yw Před 3 lety +5

    What’s up Wes , glad to see you are still at it and Im happy to see your channel getting traction. Please don’t stop. You were always dedicated to the your craft. A friend from service champ days. You rock dude

  • @erik1514
    @erik1514 Před 3 lety +2

    That’s some great troubleshooting! I love hearing your thought process on these.

  • @jfrancis98
    @jfrancis98 Před 3 lety +1

    Well done. Thx for being thorough!

  • @davidfreeman2316
    @davidfreeman2316 Před 3 lety +5

    Nice tip on how to check for a clogged vent pipe by removing vent piping from unit.
    Thank you.

  • @chairde
    @chairde Před 3 lety

    Thank you for showing the roof vent and the furnace on your phone at the same time. It was very informative.

  • @keithcress1335
    @keithcress1335 Před 4 měsíci

    This was a sweet cause-an-effect demo. Thanks!

  • @dcrook232323
    @dcrook232323 Před 3 lety +1

    Great multipoint check vid. Very useful. 👍

  • @MrPrios1
    @MrPrios1 Před 2 lety +1

    Yep that was a great video, showing the problem made it 100 percent better.

  • @Samlol23_drrich
    @Samlol23_drrich Před 4 měsíci +1

    Really well done detective work and resolution. A+

  • @marym-m7127
    @marym-m7127 Před 2 lety +3

    Thank you!!! This is the best lead after a lot of reading and videos on what might be going on with our new furnace. Our buner actually rattle and blow out, eventually either catching or going into lockout

  • @KateOnYT2023
    @KateOnYT2023 Před 7 měsíci

    very cool video. been doing hvac 2 yrs now always learning something new. thanks!

  • @padilla7019
    @padilla7019 Před 3 lety +1

    Great troubleshooting to learn from

  • @We4winds
    @We4winds Před 2 lety +1

    What a helpful video! I fill the thrill with your hand on the gas valve, ready to shut off the whole thing. Good finding!

  • @anthonyhitchings1051
    @anthonyhitchings1051 Před rokem +1

    xlnt work, great use of Facetime

  • @beerbrewer7372
    @beerbrewer7372 Před 3 lety +1

    Great troubleshooting!

  • @davidmilessr.5198
    @davidmilessr.5198 Před 3 měsíci +1

    Brilliant, you are an absolute genius

  • @toddt6730
    @toddt6730 Před 3 lety +2

    Good catch on that one, no screws holding that cap just dropping straight down

  • @kennethbrantley11
    @kennethbrantley11 Před 3 lety

    Excellent diagnosis

  • @joseorta9928
    @joseorta9928 Před rokem +2

    good job...simple solution..all the way from Monterrey Mexico...

  • @mikevon7858
    @mikevon7858 Před 3 lety +1

    Great Job ,, good work , nice trouble shooting

  • @stevencarrillo3615
    @stevencarrillo3615 Před 2 lety +1

    Like how you wet through the hole problem and how you fixed it that was a great help

  • @donnierobertson3088
    @donnierobertson3088 Před 3 lety +1

    Great job and video like always

  • @craigmarshall40
    @craigmarshall40 Před 3 lety +1

    Great find 👍🏻😊

  • @stratocat9
    @stratocat9 Před 2 lety +2

    Great video! I learned more in this video than the last dozen videos about heat exchangers!

  • @HighVoltageMadness
    @HighVoltageMadness Před rokem +2

    Wow flame rollout from blocked vent. I didn't think it would do that because the pressure switch would keep it from coming on.

  • @beotheguitarist
    @beotheguitarist Před 3 lety +6

    Just subscribed because I love this stuff. Like the HD quality and the attention to detail. Please keep the videos coming!

  • @hkhsm359
    @hkhsm359 Před 3 lety +2

    Good catching.
    Thanks for sharing.

  • @ricktruelove
    @ricktruelove Před 2 lety +1

    Good job! Way to hustle.

  • @nezamex4240
    @nezamex4240 Před rokem +1

    Great. Video. Thanks

  • @philipevans1897
    @philipevans1897 Před 2 lety +2

    Very instructive. I believe that's my problem because it's happened to other units in the complex that I manage. I'm too old to climb on roofs anymore so I need to get a young helper.

  • @sergiomontoya7929
    @sergiomontoya7929 Před 3 lety +3

    Great videos man keep them coming 👏 👌

  • @Evelin9812
    @Evelin9812 Před 2 lety +1

    Wow that’s nice thank you I have the same problem in my house now I can fix it 👍👍👍

  • @wayneschneyer8699
    @wayneschneyer8699 Před 3 lety +3

    I just subscribed because of the excellent video and correct diagnosis.
    Former product rep for Bryant. Well done sir!

  • @j81851
    @j81851 Před rokem +2

    Check draft, combustion with an analyzer and formulate an opinion. Excess backpressure (flue too small, too many elbows/offsets partial restriction very dirty or decomposing combustion chamber. The cap would be step one or beginning not the finis of the investigation. Exhaust gas temp would likely be high if draft and/or inlet air is not correct. Looked like a lot of flame there not staying where we want it - in the cumbustion chamber tubes.This is not a one diagnosis answer.
    Particularly on a unit that old I'd ring her out good. A 20 year old gas furnace with that kind of roll out still evident has problems just a new cap are not going to fix. Draft check, attic ventilation, inlet air adjustment, gas pressure, stack temp % CO in the stack. visual of the stack in attic as the top looked kinda ratty. *Also noticed it appeared they reduced the stack size coming out of the roof*! Wow see what I mean? The cap is a hint and evidence not the end of the diagnosis!!
    I respect your skills but 36 years of experience is wrapped up in this comment from me with the best of intentions to benefit you and all of us that want to do good work and keep our customers safe!

  • @CHIBA280CRV
    @CHIBA280CRV Před rokem +1

    Nice work dude 👍🏼👍🏼👍🏼👍🏼👍🏼

  • @songsofdeliverance8757
    @songsofdeliverance8757 Před 3 lety +3

    Thank you for this detailed video! We’re having furnace issues like this one, had a HVAC technician come look at it but didn’t fix it. We’ve paid him, but still have the same issues. Learning a ton on here to fix it ourselves..thank you!!!

    • @NighthawkHVAC
      @NighthawkHVAC  Před 3 lety +2

      Thanks for watching. Hope this helps. Just please be careful as this type of issue can be dangerous. I still recommend contacting a professional HVAC technician to check your unit. Thanks for watching.

  • @markbarber1920
    @markbarber1920 Před 3 lety +2

    You have very good diagnostic skills!

  • @Scott-hb8pu
    @Scott-hb8pu Před 3 lety +1

    Great job nighthawk!

  • @emen4438
    @emen4438 Před 2 lety +1

    Great video as a newish maintenance tech this was a very educational video! Subscribed

  • @lgonzalez1154
    @lgonzalez1154 Před 3 lety +1

    Great video budd thank you!

  • @1515alaro
    @1515alaro Před 3 lety +2

    Good catch!

  • @franciscoramos8808
    @franciscoramos8808 Před 2 lety +1

    Good job .

  • @abazism
    @abazism Před 2 lety +1

    Thank you very much for the video

  • @andrewthacker114
    @andrewthacker114 Před 3 lety +2

    Good clip learnt a lot in that clip.

  • @jcoppeta9474
    @jcoppeta9474 Před 2 lety +1

    Good find

  • @drasco61084
    @drasco61084 Před 2 lety +1

    Alright yet another thing to check on our system hahah thanks!

  • @yamazaheer6966
    @yamazaheer6966 Před 3 lety

    Thank you for sharing

  • @sukieme1
    @sukieme1 Před 2 lety +1

    Nice find

  • @bonzeusbonhamito5648
    @bonzeusbonhamito5648 Před 2 lety +1

    Thank you so much, even I could understand it! 👍🏽

  • @TandNServices
    @TandNServices Před 3 lety +1

    Great Find!!!

  • @sluf1963
    @sluf1963 Před 3 lety +3

    Thank you so much , I am having a similar issue , narrowing down my furnace noises . I don't have a bad rollout , but ignition bangs after a switch activates canceling fuel .Fan stays on , then igniter glows , fuel clicks 3 , or 4 times , the a loud thump , and burners ignite with a good blue flame , very small Orange streaks every few seconds flowing with blue flame , not rolling out . Looking into blocked flute , and others next .

  • @eidos4190
    @eidos4190 Před 3 lety +1

    Nice editing. Nice video.

  • @natboucher1774
    @natboucher1774 Před 3 lety +1

    U did a great job u r not horrible

  • @robertcherry4971
    @robertcherry4971 Před 9 měsíci +2

    I like your style brother… There is only a handful of us ,that are great,at what we do. I would say it is because when one loves what they do,they become pretty darn good at it.Thanks for sharing your experiences brother.

    • @NighthawkHVAC
      @NighthawkHVAC  Před 9 měsíci

      Thanks for the kind words!

    • @edwardmylnychuk5774
      @edwardmylnychuk5774 Před 5 měsíci +2

      as a meat cutter the store i was in had counter problems and young guys would come in and play around but the problem still was there, finally an older guy come in and we got talking and i showed him that the air was not circulating like it should so he figured out the problem and it never occured again, the store got new people to come in after all that crap.

  • @michaelclayton4703
    @michaelclayton4703 Před 2 lety +2

    Thank you, I've had to reset my high limit switch twice today, just entering furnace season, I know what to check for to be safe and a professional technician was already scheduled to come onsite for an inspection. I'll be sure to pass along my findings and let him take it from there. I can probably do it, but not betting my family's life on it! Great video, thank you!

  • @barnyardbrio7597
    @barnyardbrio7597 Před 6 měsíci +1

    brilliant! thank you

  • @joshdessources5794
    @joshdessources5794 Před 2 lety +1

    Really nice vid!

  • @chesstime356
    @chesstime356 Před rokem +1

    Nice video thanks dude

  • @sick-n-tired-patriot3922
    @sick-n-tired-patriot3922 Před 5 měsíci +1

    Great info

  • @Randylazz
    @Randylazz Před 3 lety +1

    Good stuff right there...........😎✌️

  • @phillipjoy8191
    @phillipjoy8191 Před 3 lety +1

    Good job 😜

  • @roykinder4134
    @roykinder4134 Před rokem +1

    Good job diagnosing the problem, a simple fix for someone who is a pro.

  • @Joshyodenn
    @Joshyodenn Před 3 lety +1

    Great video

  • @janeth8579
    @janeth8579 Před 7 měsíci

    Hi there, thanks 4 expert diagnosis. I just had the rollout switch replaced but the hvac tech told the tenants possibly not to turn on the heat due to flame rollout. Tomorrow Im having a licensed tech that Ive worked with before check out the system and if more repairs r needed. Your video gave me a few places we can ck albeit we may need a new system wh is wh this tech recommended but if that is so, why wld he install a new switch. The unit is 3-4 yrs old. I got the info 2nd hand from the rental agent as I don't live there. Jan

  • @Nba19980
    @Nba19980 Před 2 lety +1

    Good stuff

  • @clarencehill7048
    @clarencehill7048 Před rokem +1

    Good Job

  • @joelmelendez5916
    @joelmelendez5916 Před 2 lety +1

    Good explenation

  • @pelon542
    @pelon542 Před 3 lety +1

    good finding,im surprised the pressure switch was made the whole time but i guess it was border line of not,nice job

    • @NighthawkHVAC
      @NighthawkHVAC  Před 3 lety

      I know. You would think the pressure switch wouldn’t close. It was setting off the draft switch though. Good thing it’s there.

  • @hozerhvac4406
    @hozerhvac4406 Před 3 lety +2

    Good work

  • @jmc1771
    @jmc1771 Před 3 lety +1

    Well done

  • @robertlyman9789
    @robertlyman9789 Před rokem +1

    The one I had the other day was clogged air filter overheating the auto safety in heat exchanger

  • @fadinoail
    @fadinoail Před 3 lety +1

    Good job

  • @mikehammer6909
    @mikehammer6909 Před rokem +1

    One time I found kids toys in a 90 plus gas furnace pvc fresh air intake and when I had the door off it would run fine and as I was tried to put the door on it practically grabbed it out my hands and shut and it would shut off

  • @alexislopez9017
    @alexislopez9017 Před 3 lety +4

    I’d still check the heat exchanger for any damage caused by this.

  • @richardmurry9866
    @richardmurry9866 Před 3 lety +1

    I had this with an oil boiler. The chimney caps slid down and blocked the top of the Chimney. The equipment ran fine for the first two minutes and then started popping in banging.

  • @neshanahbarnett9579
    @neshanahbarnett9579 Před 2 lety +1

    thank you

  • @rodgraff1782
    @rodgraff1782 Před rokem +1

    Put your hand over the small square area where the draft rollout switch is that you reset. If it isn’t negative pressure there, you have a blocked flue, and the draft safeguard switch is just doing its job.

  • @smarterthanyou9090
    @smarterthanyou9090 Před 2 lety +2

    Keep that cap; just put a pipe clamp on the chimney, or better yet just take a piece of 3 inch PVC and slip it over the chimney. That will support the cap, protect the chimney from further rust damage, and look more visually attractive -- for a cost of about 12 bucks for an 8FT length of PVC.

  • @jeremiahhively3025
    @jeremiahhively3025 Před 3 lety +1

    Love the music

  • @SunilPatel-rj1zk
    @SunilPatel-rj1zk Před 2 lety +1

    Hi
    The video is very good & informative . My Lenox furnace (2008) model, started shutting off aftet 15/20 minutes, i called 2 different HVAC certified technician and they both told me heat exchanger is gone and need to replace the whole furnace as its heating up the switch and it’s turning off.

    • @NighthawkHVAC
      @NighthawkHVAC  Před 2 lety

      If you have a cracked heat exchanger you need to either replace the heat exchanger or the furnace.

  • @ittech7967
    @ittech7967 Před 3 měsíci +1

    Thanks for posting this. We have gas wall heater it and seems to have some flame roll back. The flu vent is clear, How would i check for cracks? Thanks again

  • @hmm3597
    @hmm3597 Před 2 lety +1

    We had a roll back from birds nesting in pipe.

  • @benjamintimmins1656
    @benjamintimmins1656 Před 3 lety

    Nice find! Did you end up just putting some screws in the side of the cap or what?

  • @eduardorodriguez-ei4mw
    @eduardorodriguez-ei4mw Před 3 lety +1

    GOOD THROUBLESHOOTING

  • @mathman0101
    @mathman0101 Před 2 lety +1

    Nice catch did you also check the orifices?

  • @johngraves2968
    @johngraves2968 Před 2 lety +2

    Before you put on a new cap, what would the new cap fasten to. the venting is so chewed up, that top section of venting must also be replaced. don't just put a band-aid on it. Good diagnoses.

    • @NighthawkHVAC
      @NighthawkHVAC  Před 2 lety

      I reattached the existing cap properly to get them heat for the night. Returned the next day and replaced the flue pipe and cap. Thanks for watching.

  • @gas_man1565
    @gas_man1565 Před 4 měsíci +1

    this is just positive critism to give u a good idea. i would have tested the pressure for your inducer. other then that u did good. having a partial blockage could have damaged ur inducer and should report it on the work order to cover ur butt. when it fails.

    • @NighthawkHVAC
      @NighthawkHVAC  Před 4 měsíci

      Thanks for your constructive criticism. I appreciate it.

  • @jiismo
    @jiismo Před 3 lety

    it is a code 31. the sticker, right above your finger says the short flashes are the first number.

  • @petesilvestri
    @petesilvestri Před 6 měsíci +1

    The flashing on that riff looks problematic as well…😮

  • @rickychavez1473
    @rickychavez1473 Před 3 lety

    Nice👍👍👍👍

  • @rodgraff1782
    @rodgraff1782 Před rokem +1

    Wrong flue cap for B vent. The proper cap, along with a proper flue pipe end, that’s not butchered, would have prevented this problem. Roofers are famous for setting things on top the flue caps.

  • @001tracker001
    @001tracker001 Před rokem

    Bird or bee nest in the flue. "Inducer draft"

  • @rickl5938
    @rickl5938 Před 2 lety +2

    Thanks for the video. Great job finding the cause! But, shouldn't the pressure switch have not closed to prevent this? Is it stuck closed (control board should have detected this)? Is the correct pressure switch installed? Did you check the negative pressure on the switch with manometer?

    • @allanbrito13
      @allanbrito13 Před 2 lety

      The vent was clogged but not enough to affect the pressure switch

  • @geehernandez8446
    @geehernandez8446 Před 3 lety

    Looks like I'll be on the roof having similar issues not as intense though