Crowbar Testing

Sdílet
Vložit
  • čas přidán 19. 10. 2012
  • Crowbars are part of almost every IOT transmitter, here is how they are tested.
  • Věda a technologie

Komentáře • 16

  • @TheOnLineEngineer
    @TheOnLineEngineer  Před 11 lety +5

    The term Crowbar applies to any protection circuit that shuts down a power supply very quickly, as if you placed a Crowbar across the terminals and shorted it out. The metaphor of a crowbar is used because it is made of thick metal that will not melt and can handle a great deal of current. Hope that helps, Russ

  • @godfreypoon5148
    @godfreypoon5148 Před 6 lety +5

    Oops.
    I used an actual crowbar.

  • @LouisWilen
    @LouisWilen Před 8 lety +1

    Thank you for the fascinating video. The excellent animations and graphs are very helpful additions to the photos of the equipment.

  • @mikereynolds8804
    @mikereynolds8804 Před 9 lety

    Thanks! We just had to change a Thyratron In our old converted-from-analog Sigma transmitter. This video is nicely done and explains crowbar testing very well!
    Mike

  • @ve3enx95
    @ve3enx95 Před 4 lety +1

    2:39 I'm surprised they don't put a fuse in series between the capacitor and the thyratron. Seems like that would reduce the demand on the thyratron, since it wouldn't have to drain the whole charge on the capacitor to trip the input circuit breaker. The fuse would blow before the capacitor was fully discharged.

  • @SlowRiderDucati
    @SlowRiderDucati Před 3 lety

    I wish I had these videos back in the early 1990s when I used to work on this equipment. It is a surprise I'm still alive. ⚡⚡⚡

  • @whorton4
    @whorton4 Před 6 lety +2

    But, as often happens the $35,000 IOT will sacrifice to save the crowbar circuit.

  • @JamesWattMusic
    @JamesWattMusic Před rokem

    how much does one of those crowbar testers go for? I found one in my family members storage.

  • @mikeissweet
    @mikeissweet Před 2 lety

    You forgot to include the most important part of the video- footage of the friggin test! 😫

  • @nakayle
    @nakayle Před 4 lety +1

    MOSFETs are putting an end to this.

    • @DJSubAir
      @DJSubAir Před 11 měsíci

      Unfortunately he will never see this message. My apologies

  • @MANTLEBERG
    @MANTLEBERG Před 6 lety +2

    When working on kit like this, the S.I.D.E. rule is implimented.....switch off, isolate, dump, earth, thats what we were taught.

  • @Desmaad
    @Desmaad Před 11 lety

    Why is it called the crowbar, anyway?

  • @mikeerasmus5455
    @mikeerasmus5455 Před 3 lety

    Excuse my ignorance, but what is an IOT?

    • @SerenityMae11
      @SerenityMae11 Před rokem

      Vacuum Tube. Similar to the Magnetron tube in our microwave ovens, except more $$$$$$$$

  • @jameskelly1680
    @jameskelly1680 Před rokem

    Yeesh! Some of these photos show an unacceptably dirty high voltage compartment. Dust is the enemy. This area must be hospital clean. In fact we replaced the input air filters with HEPA grade filters. If you ever see a compartment this dirty, turn the high voltage off, discharge everything with the grounding stick and verify safe, then go get a bunch of lint-free rags and a gallon of denatured alcohol, and get to work. Old t-shirts work well. Clean EVERYTHING including the red and white wires. This will result in less corona and far fewer high voltage trips and crowbar events. Even the skin oils from your fingers are bad. Use alcohol to wipe everything down that you have touched.