How to install HOME ALARM from A to Z (SP5500-Magellan) Paradox
Vložit
- čas přidán 6. 09. 2015
- Cómo instalar sistema de alarma casera de la A a la Z
how to install motion detector
how to install external bell
how to programing home alarm system
how to switch home alarm system
how to wiring home alarm system - Jak na to + styl
erm. spirit level anyone.... As stated this is a great " how to do a crap install " video. I'm suprised he didn't wire it with speaker cable!
What mistakes I made
golf Wagen ..... Your mistakes are.... 1. The wrong type of cable, you should never use solid core cable with alarm systems they can fracture and create intermittent faults..... 2. The panel wiring is messy and your low voltage cables are right next to the mains, this puts noise on the wiring...... 3...... I'm not sure of the purpose of the relay but its good that you placed a diode in parallel with the coil...... 4....... The PIR is at the wrong level. It should be at least 3M from the ground or at ceiling hight.......5....... The bell should be outside on the wall, it serves little purpose inside.....6...... When you installed the PIR you touched the sensor head with your finger, this can damage it and reduce its lifespan.....7 ........ There is no fused spur on the mains inlet, I can only speak from a UK perspective but this is a regulation here..... 8 ...... You didn't set the time and date on the system, this won't stop it working but is bad practice..... Finaly the install is rushed, none of the cables are tidy or loomed as someone else has noted. The entire install is just sloppy and no care has been put into it. Good alarm engineers are proud of the job they do and like to make sure the wiring is tidy and the install is neat. Take more care, use the correct cable and follow best practice. I have to say I agree with the comments and I would give you the sack if you left an install like this in a customers home. Sorry to be so blunt but decent engineers cringe when they see things like this. Can I ask what you have used the relay for?
He would be a good inquisitor. I will reply later.
@@TRS-Tech Now we wait for your video Stuartbe. Lets see how you put in practice the theroy. Thanks in advance.
To many mistakes firs mistake the panel its not lavel
Many Many Thanks For your Hard Working to Show us this....
Good job , there are so many tools 🛠 out there,proper tools makes proper job bro. Aiaiaia
thanks man i got a clue with this thinks from now i can work on tt with a know how...!!
very helpfull for basic instalation
Thank You for this example even though its not for all and not in english for programming but thanks
so
Hi, did you programm it using pc or did you from the keypad only thanks
I understand ur just showing us your skills networking do that
thks a lot i was looking for how to install all this detectors and bell , good job , i can tell after all the research i made , i tray to fix the lousy job one""expert "made
Many many thanks Bro.......
Hello. Thank you for this video. I have a digiplex evo 192. Can i assume it is the same procedure? Thanks
Installing the same, but slightly different programming
Very professional. We manufacture burglar alarm control panel and others. Maybe you can give us a suggestion.
Besides, our network alarm monitoring system solution integrates alarm and monitoring in one solution. Maybe it is useful for you.
some of us we are the first learner please try to speak when ur doing but its very nice...thanks
I do not know English, so I prefer silence
❤❤❤ your the man bro
Why using utp cable for installation? Can you get 6 wire cable for alarm?
The reason why this was installed in his secret place is because NO ONE should ever see this mess. 🤦♂️
very good thank you
thank for comment
It gave's me more idea on how to install this alarm system.. Sir Golf Wagen, do you also have diagram? thanks for this video.
i am not sir, mick jagger is sir, i am "normal human"
I don't have a wall with secret place written on it, so can i still fit a intruder alarm in my house?
This type of installation is not up to the standards in Australia,though; it will work.
Thanks
You're right, but this is a demonstration of how to make it go
hi there, any idea about atz setup, for TC and com port does it matter the wiring or can it be swapped ? As i understand it is just a circuit that needs to be completed in order to set off the alarm from motion.
NC contact can be, can be and with EOL resistor
ok thanks, do you know much about the programming ? I see i can program the atz by accessing section705., Do i input Power + installer code, then table button and then 705 ? Not sure from there how to enable and disable each option. thanks.
I have setup zones 1-5 with 1K ohm resistor and 6-8 with 2.2K Ohm as supplied. thanks
The Arachchies I think it is difficult to explain this through comments, be it to study
You will generate hotspots on the wiring without ferrules! They are obligatory in most places so USE THEM! (Especially on the power lines). Also the speaker and the keypad needs reinforced alarm cable because of the power consumption.
siren AS500 very little comsuption 100mA only
Keypads consume so little energy in the form of milliamperes that no perceptible heat is ever generated. Telco quad wire is the norm for installations in Canada. Some ULC systems demand that stranded wire be used but only in commercial ULC locations. Stranded wire has its merits but not in normal residential installations. Cat5 level and higher are not recommended because of the corruption of data transfer between various modules.
@@theintruder77 Time flies, and I am through a lot of wiring. For the stranded wires, I still use ferrules, even if it's 12V DC, I sleep well that way. And for the wires, we use alarm cables here, 6x0,22 or 8x0,22, and for the siren 2x0,5+6x0,22 for when there is a battery to charge, while the siren is operating. That's what I meant by the reinforced part. But yes, don't use cat5, it is also a mess when it comes to color coding the system. And looks extra bad in the documentation.
THIS IS A GOOD EXAMPLE OF HOW NOT TO INSTALL!
'm not arguing
+golf Wagen .
Totally agree
What mistakes I made
:D
How big is the main box, please?
wooaawww great instal
everyone does not think so, read comments
Great Information Video , thank you for your time !
thanks for coment
You always want to keep the drill motor moving as you break through the wall. This will ensure the best possible chance of hitting electrical or plumbing. Never use a level, most burglars have OCD and this will confuse them if they happen to locate the panel. I can't speak to the rest of the video, I had to stop watching before I got hurt.
My sentiments exactly. This installation is dangerous. I am amazed that the transformer is placed inside the panel and being 240vac that makes it even more fun.
Stop it, my sides are hurting ! Would love to see a tube and batten install. It is installs like this that jacked up false alarm rates and is the reason people ignore intruder alarms sounding.
Just like many industries you can install something and you can install something properly !
Nice
Why use relay for the external bell trigger?
+Akis Papados reacts to faint bell but on the central terminal there comes less, it should be rotated by a relay
Podobný pořad je i o jídle. Myslím že se to jmenuje peklo na talíři. Good luck with the pertinax. Tonek Trósil from Katoda Olomouc.
ale dobre som to domontoval, co hovoris na to
To jo, ale silnoporud nech radsi nekomu jinemu. :-)
zelenožltému odborníkovy
Can you show how to install more then one IC detector on one zone,please. (serial), and how to install TOL resistor?
OK
Jesus, please tell me this was someone's idea of a seriously bad joke. This guy hasn't got a bloody clue, thought I'd seen some bad installs out on site but the guy takes it to a whole new level. No point asking about a spirit level guys, he wouldn't know which way up the bubble went. Not only a crap job but he's using telecom cable for wiring.
To whoever made this video. I'm going to break in to your house. The alarm won't go off.
what voltage is your bell?
+Mirsad Alija all parts - bell too 12VDC, 12 to 14,5VDC
wheres your end of line resistors??,id love to see how you zone double??
I also have a video about zone doubling "very special" ATZ
If only he could also talk..... How great would that be???
Other than that , Great, very educating.
добрый день
How to operate 10 fire sensors, each sensor in a different zone from the other
you can make these things cut the grass if wanted anymore! just so long as the relay to the outlet is strong enough. Jim besides I'm from US other countries use 240
I do not understand
No explanation as to what he is doing?
He stripped the power cables when he stripped the black insulation
why
just spoted the cat 5 cable to. The scary thought is that someone may find this video and think its an instructional video. This video shows some good reasons as to why I think DIY alarm systems should not be sold to the public. !!!
Unprofessional work! No locking resistance (EOL), there is not screening (Shield). I drive the students away because of work like this! :P
+Márton Palkó eol I did not use to be operating easier and shield ... to explain - shield what is good please
+golf Wagen EOL prevents the plain sabotage of the system. Without it plainer the system, but a pupil can cut it out! The shield protects the system from the exterior electrostatic and electromagnetic disturbances. He will not leave in from a lightning! Read the manufacturer's setup guide.
+Márton Palkó I agree, but eol only enhances the protection against sabotage and when he blows the flash and faith in the shield will not help
I don't andrestan ....
Pa sta ti spoji ziv i zdrav bio...i oni sto znaju sad su izbezumljeni....
Two screws is totally unacceptable for installing the most touched item in any security system. The keypad control.
Could not agree more. I remember a housing estate that had the first fit done and a local company decided to fit the Scantronic 9800 (if anyone remembers that panel). We ended up checking all these systems that kept going into tamper.... We discovered that the keypads were all mounted using double sided sticky pads (facepalm) .... They had a dodgy enough back tamper as it was !
The installing company ended up having every single URL pulled after the police attended nearly 60 false triggers in under 2 months.
I have no objections or problems with someone filming an install.... My problem is that many people may treat this as a "how to" video. This is why the kit and industry have a bad name. Aside from equipment developing a fault a properly installed system should NEVER false alarm. To install a system properly requires the installer to know all the pitfalls like mounting a PIR above a radiator or selecting mouse fart sensitivity modes on detection devices.
This may sound petty, picky or over the top but people need to remember that a system that fails to operate can give insurance companies the perfect excuse not to pay out. Would you expect your car to work most of the time aside from the engine cutting out and the wheel coming of now and again ?
Not everything is suitable for DIY installation !
Excellent instruction thank you so much!
Hello, when connect the keypad to the central it gives me error: this unit is ready to communicate with the central. Please contact the installer "
What can I do to bypass this? The wiring is correct
Write What's your keyboard and what you central panel (example panel DGPEVO 192 keyboard K641+)
Dont you own a spirit level ??
+Graham Mitchell not use am use my eye. 2 eye
He doesn't have a hammer either....
understant
Bude niekedy aj slovenská verzia ? :D
jedine ze byi som to iste nadaboval
TO by som bol za, pretože stretávam sa s mnohými ľuďmi čo si doma robia svoje zabezp. sys. a myslím že im to pomôže. Ale inak super video, čo sa týka ukážky inštalácie aj nastavenia. Prípadne ak by ste niekedy natočili aj ďalšie a boli by v Slovenčine :) Ale to je iba návrh.
Jak u toho paradoxu funguje sběrnice musí se tahat do serie nebo se může odbočovat jako u Jablotronu
kdyz paradox zacinal psal v navodu ze do hvezdice a tedy odbočovat dle libosti. ted už radeji tvrdí postupne tahat linky. ale v praxi sem to daval jak mne napadlo. u malyich vzalenosti je to určite jedno.
Hola amigos necesito ayuda para conectar un un discador gsm a una dsc pc1832. una ayudita por favor
Download the install instructions and keep trying
How to connect to a modem!
Do it with spectra 1759EX
+Mario Rosario see my last video czcams.com/video/iy0AvjdXN5E/video.html
I’m trying to get my head round this. I used to be an alarm engineer many years ago. I always used alarm cable-4,6 or 8 core. Never phone cable! The inside of your control panel looks like a birds nest. That needs tidying up. The mains cable and alarm cable are too close together. There’s a lot of things to talk about here. I always covered the heads of my screws inside my PIR’s with electrical tape. The foam backing on the bell box- am I missing something here? Is that how it’s done now a days? You touched the PIR sensor!- Jeez, I would have murdered an apprentice for doing that. That relay! What the hell was that? Maybe it’s just different standards in different counties, but wow! Was this some sort of demonstration video. Is this a DIY job. So many questions.
I'm using an alarm cable in the real world. but often the customer already has a 5e cable installed.
I'm going to get involved and there's no problem. I think the problem would be long distances.
"he inside of your control panel looks like a birds nest. That needs tidying up" - I agree with it is my weakness
relay I give because (because we do not want to program pgm)
I only put the insulating tape on the screws when the situation demands it
catch a sensor that is no pain
100% agree ! 👏
Whole point of adding video is so others can learn .. well of course to get all the hits. FFS commentary is needed..
Good. And what about the end of line, and atz. A professional technician can use the atz, i think...
Yes, but the sample must learn first steps
remind me not to call you!!!
j'ai une alarme a installé de marques pro lay ki prend une puis mes je ne m ensort pas au niveau de la programmation
+Maximezankia Zankia Je l'utilise Google traducteur et bien comprendre le français
i use 4 wirres for one motion detector coz i use resistors
+TheBrainwasher82 you did well
Of course you do because you need 2 for power and 2 for data.
cok fazla eklemısın kapatmaktan bakmaya zaman kalmıyo
Ben kamera kötü bir başlangıç yaptı
Does anyone know how to program a phone number on a Paradox 1641 Spectra keypad? please note that this keypad does not have * or # signs. Thanks
It is a system SP 1728 old and where you think you can not program the phone number as the user. It has to do Installer
Yes. Call a professional alarm installation company.
Nice job
thanks
tenho central paradoxdpg894 travada o que fazer
894 com a gente ou vender
Tell me your alarm system and I'll tell you if it's good or bad. Trust me you'll be surprised
Can translation what's you doing 😊
GIVE ME THE QUESTION - I'm super technician
DAJ MY OTAZKU - ja som super odbornik
golf Wagen Can you tell me how can I wire two or more sensors to a single zone on a Paradox system?
@@The3PLX for example use relay. sensor nc com send minus for this relay. relay place in alarm box. sensor on = relay off. relay off = zone open.
31:55
That looks level. lol
and that ladies and gentlemen is what not to do
This is the worst panel wiring I have ever seen 😁 the cables not properly loomed and no connectors used on joints
+Colmán Boylan laying in the control panel's my weakness, but it works well
Armed 30:45
As a Smart Home Contractor, this is a horrible, sloppy job. The wrong tools are being used, the panel isn't leveled, it's just very sloppy. I would fire any of my employees if they did a job like this.
i think the house need a better bricks..
Why don't you buy yourself a nice pair of wire strippers and a small hammer to tap in rawplugs instead of end of screwdriver?
wire strippers are we doing wrong, I often have a variety of cables. Hammer is a good thing, I agree, but I use often installation for short span screwdriver
Not level, nicked the line core when you stripped the incoming (4:14), cable types wrong. Good grief... what a shambles!
It's need to explain that silent
I would like to gift you a spirit level. Can you message me with your postal address so I can send you one?
I installed my first system when I was 13 years old, the programming back then was dip switches and a pot. Keep up the study on security, I wish you well.
Hey, when I was 13 I played hockey in the yard. Work has never been my dream. But seriously - when I filmed this video so I had a camera placed askew, so it seems that I've mounted askew. but not in practice, do not use a spirit level still is governed by the eye. (Monte furniture when there is already a spirit level I use - I have such the ancient, collector's item will make of it video) ...
dobrý den,
mohl bych na vás dostat kontakt? nejlépe telefonní kontakt... za ucelem pomoci :)
I guess hes not going to level it. What kind of system? no intro.
level tool missing
Golf, do you actually know what you're doing?? I've fired technicians for working like that... Oh and in SA, shitty install like that is actually illegal...
+Wessel Meiring I do not understand properly because I do Google translation, but it's a criticism I get it
mexican is ilegal i am slovak boy freedom my credo / slovakia bratislava sagan,šatan, bondra, chalúpka etc.
What the hell did he do wrong?? It was just a demonstration for god sake!
right
If one or two things were done wrong , I would be able to give an advice how to be done in a proper way. But here everything is done absolutely unprofessional.
so I wish you a lot of success in your professional life
hope it helped every one lol
Have a look at the inprover video on youtube, search for DadTech Ltd Inprover Detection System , this will totally validate any property alarm system, it will prove to outsiders,whether it is, or is not a false alarm!
I wanted to cry watching this where do i start 1 NEVER EVER use dater cable for alarm installs 2 all devices should be maxing amount of fittings possible 2 screws in the keypad come on that be falling off the wall in a week or 2 and the bell box well dont get me started and the mess in CIE (control panel) come on if your going to do a job do it right if not leave it to the ppl who can and will
Kya bata rahe ho ?
paradox
for ever
перфоратор фирмы BOSCH дырку сделает где хошь
Too many know-it-alls think they can install their own alarm properly. I know alarm company installers that still cannot get it right. Nearly all small alarm company installers are capable of wiring a home for 110vac but hardly any electricians could properly install a professional alarm system. Yet, electricians have to be licensed and alarm companies do not hire licensed alarm technicians because there is no such thing. Thus we get peel and stick systems being installed by the likes of ADT at horrendous monitoring fees and binding contracts by ill trained and installers that can barely speak English.
Wireless home automation/alarm systems are now available to the DIY consumer thru a great home defense and self-defense company called Security AllStar. Go to www.securityallstar.com where you will find package deals that provide a state of the art smart home hub called UltraSync professionally configured for self-installation. You can purchase it alone or with a firearm in a package deal if you choose for total protection. www.securityallstar.com/en/ultrasync-hub-standard-package www.securityallstar.com/en/package-deals
SP5500 is Spectra, not Magellan
adrian, sp5500 mg5050 sp6000 is very similarly programing /one guide/
arkadaş dilsiz galiba:)
Biz işe demek
The ar nothing know ectuly he what works
This installation is dangerous. The transformer cannot be placed inside the panel box. Not kosher with the electrical code in North America. A level would have been nice. Totally inappropriate 220vac connection and could be a fire hazzard. This video should not be allowed on Utube. This is what give alarm systems a bad rap in the industry. Do not follow this instruction. Please.
Cat5 wire should not be used with Paradox Panels. The data transfer can be corrupted between modules and cause many problems. Many things this guy does are not , definitely not acceptable. My company would never let this guy through the door.
Sloppy work indeed!
No offence but if you bending that motherboard with such force when you driving in the screws you will ruin every circuit and soldering on the piece...
+Mikka which component mind
Any component that soldered to a board at risk when you bend the board. Cheap manufacturers in China and some shady Europeans make shitty boards and bad quality soldering..so to bend a board is not something I recommend in general.
+Mikka My father also told me that, on tightening, and you're probably right
Mains cable going direct to panel transformer? Very bad installation, mains cable should go to an non switchable spur fuse, then from that to the panel transformer. I take it this guy is no alarm engineer.
U should explain what ur doing showing just don't help much
+kevin frazier My speaking English is bad, so just shows, but I tried to make a good
😂 paradox
😂
Ok , clearly you cut the cable when trying to strip it, wrong wire Gage , panel not level, oh I can keep going, get out of the industry please.
Not a properly made connection inside the panel and inside the detector...Bad demonstration but the worst is that this kind of stuff should not be shown on internet....For godshake this is a security system...End of story.
healthy food is more important than an alarm
buy some right tools for this kind of job and then make a proper video...