Unloading Valves (Full Lecture)

Sdílet
Vložit
  • čas přidán 12. 09. 2024

Komentáře • 12

  • @helicopterpeace7434
    @helicopterpeace7434 Před 3 lety +3

    Hello Jim, thank you for your video lectures. They have very valuable. Anastasia

  • @augustyn1967
    @augustyn1967 Před 7 lety +3

    Very good video. helped me touch up on a few issues. I was looking for a cost affective way to use a gas operated positive displacement pump with closed center valves.

  • @michaelcostello6991
    @michaelcostello6991 Před 5 lety +2

    Unloading valve is also called accumulator charging valve. I searched this first on your channel but could not find this video. Perhaps give it both names so one can find it. Thanks for great video. mike

  • @commenter5469
    @commenter5469 Před rokem +1

    Hey!!! There’s damn good restaurant at Petro truck stop. Called Iron Skillet! 😁

  • @johnevan7737
    @johnevan7737 Před 4 lety +1

    Hi Jim,again thanks for these lecture.These Differential Unloading Relief Valve is the same as Unloading Relief Valve?Also the difference in pressure is constant bet the pump side and accumulator side?Some hyd manufaturer dont carry these item.Ive encounter an Unloading Relief Valve w/ the check valve incorporated wit in.Really learns a lot from your lectures.More power!!

  • @heavyjay
    @heavyjay Před 3 lety +1

    Wouldn't it be more efficient to just have pump A turn off at 500 psi?

  • @arslanahmad1195
    @arslanahmad1195 Před 7 lety +1

    I read in a pump data sheet that starting pressure should not be more than 20 bar for that pump. Is this restraint induced by the pump mechanical design or the prime mover motor's electrical characteristics?
    Will this restraint prohibit the use of the third unloading method?

    • @bigbadtech
      @bigbadtech  Před 7 lety +2

      I'd hesitate to give you a definitive answer without looking at the specific data sheet but because this limitation is mentioned on the pump data sheet (rather than the prime mover's starting torque) this limitation would probably be because of the pump's mechanical characteristics. Provided the maximum starting pressure is above the low pressure limit for the pressure switch it would charge the accumulator.

    • @commenter5469
      @commenter5469 Před 9 měsíci

      You probably looking at the LS controlled piston pump. For those LS margin or “stand by” is about 20 bar.
      The lecture is not talking about some specific pump type.

  • @commenter5469
    @commenter5469 Před 9 měsíci +1

    Turning pump on and off - will kill the motor very quickly. And will be even more annoying than listening to system load and unload.
    Just get a darn Pressure Compensated pump, and get rid of the whole shebang all together.

  • @danalex2991
    @danalex2991 Před 7 lety

    In both scenarios, the pilot operated UV and the differential area UV there are pressure cycles that the accumulator goes through .
    The only difference i can see that is in the differential area UV you can control the pressure range and if possible minimize it but in the pilot operated UV you do not have that level of control . Is there any other advantage ?

    • @bigbadtech
      @bigbadtech  Před 7 lety +2

      Honestly that's it. With the differential unloading relief valve you basically operate off the accumulator between the high and low value while the pump is unloaded. Only when pressure drops below the low value does the pump recharge the accumulator.