Dead Radon Fan? Check This Before Calling Your Mitigation Company
Vložit
- čas přidán 2. 08. 2024
- Has your radon fan stopped working? If so, be sure to check your GFCI outlet first.
We went out to this Prior Lake, MN home because the homeowner noticed that the U-tube manometer was reading zero. She assumed their radon fan needed to be replaced.
When I went into the attic to see what fan they had, I noticed that the GFCI outlet had tripped. All I needed to do was push the reset button on the outlet. You probably have an outlet just like this in your bathroom.
Check out our playlist on troubleshooting radon mitigation systems. • Troubleshooting Radon ...
Links:
We earn a commission if you purchase using the links.
RadonAway Radon Fans
RP140 - amzn.to/3s0avdn
RP145 - amzn.to/45iItIv
RP260 - amzn.to/3QqXq78
RP265 - amzn.to/3OP8v0w
RP380 - amzn.to/3OppAgd
XP151 - amzn.to/444AwW6
XP201 - amzn.to/3Yv6aLe
XR261 - amzn.to/3OOkPhx
GX3 - amzn.to/3Yr2c6u
GX4 - amzn.to/43WsOgQ
GX5A -amzn.to/451PBJp
GP301 - amzn.to/3QrUreE
GP501 - amzn.to/3KynNUJ
SF180 - amzn.to/47o02IY
Fantech Radon Fans
Rn1 - amzn.to/3DL0weJ
Rn2 - amzn.to/3Ot86iT
Rn2EC - amzn.to/45niJum
Rn3 - amzn.to/3KA2NwT
Rn4EC - amzn.to/446RTpo
AMG Festa Radon Fans
Spirit - amzn.to/43YOl8B
Maverick - amzn.to/44abEww
Hawk - amzn.to/3s70c7p
Legend - amzn.to/3OwgVZp
Prowler - amzn.to/3DMOSzI
Eagle - amzn.to/44ZwT5m
Eagle Extreme - amzn.to/3Kvthja
Radon Fan Cord - amzn.to/3DOzanT
Rubber Couplers - amzn.to/441AO07
Radon Test Kit - amzn.to/440t3rd
Radon Monitor - amzn.to/3Qxjmxx
Check out the @radonaway3614 fan selection guide: www.radonaway.com/pdfs/radon-...
PDS Radon Supply sells RadonAway and Fantech radon fans; Use promo code JESSE for 5% off your first order. radonpds.com/product-category...
Frequently used products:
Ecosense Radon Monitors: Use promo code ARM to receive a discount ecosense.io/ARM
TEC DG-8: store.energyconservatory.com/... TEC Fog Puffer: store.energyconservatory.com/...
Radon Sealant - amzn.to/2Mu6yZv
Milwaukee Super Hawg Drill - amzn.to/32m67sk
Milwaukee 16’ Autolock Tape Measure - amzn.to/3ouZFXQ
Bosch 5-Inch Core Bit - amzn.to/36ik4Xw
• How Do You Wire a Fant...
• How to Wire Festa AMG ...
• Loud Radon Fan? How to...
• How to Replace a Radon...
Get an Estimate (within an hour of the Twin Cities, MN metro area.) americanradonmitigation.com/f... or call 612-474-1004
If you live outside our service area, check out our virtual consulting services at americanradonmitigation.com/c...
For basic questions, leave a comment, and we'll try to answer when we have the chance.
Thank you so much for watching!
Roadtrip by Scandinavianz / scandinavianz
Creative Commons - Attribution 3.0 Unported - CC BY 3.0
Free Download / Stream: bit.ly/l-roadtrip
Music promoted by Audio Library • Roadtrip - Scandinavia...
Replacement radon fans are linked below.
RadonAway Radon Fans
RP140 - amzn.to/3s0avdn
RP145 - amzn.to/45iItIv
RP260 - amzn.to/3QqXq78
RP265 - amzn.to/3OP8v0w
RP380 - amzn.to/3OppAgd
XP151 - amzn.to/444AwW6
XP201 - amzn.to/3Yv6aLe
XR261 - amzn.to/3OOkPhx
GX3 - amzn.to/3Yr2c6u
GX4 - amzn.to/43WsOgQ
GX5A -amzn.to/451PBJp
GP301 - amzn.to/3QrUreE
GP501 - amzn.to/3KynNUJ
SF180 - amzn.to/47o02IY
Fantech Radon Fans
Rn1 - amzn.to/3DL0weJ
Rn2 - amzn.to/3Ot86iT
Rn2EC - amzn.to/45niJum
Rn3 - amzn.to/3KA2NwT
Rn4EC - amzn.to/446RTpo
AMG Festa Radon Fans
Spirit - amzn.to/43YOl8B
Maverick - amzn.to/44abEww
Hawk - amzn.to/3s70c7p
Legend - amzn.to/3OwgVZp
Prowler - amzn.to/3DMOSzI
Eagle - amzn.to/44ZwT5m
Eagle Extreme - amzn.to/3Kvthja
Radon Fan Cord - amzn.to/3DOzan
As an Amazon Associate, we earn from qualifying purchases.
You are an honest contractor....almost an oxymoron these days. From watching this video i am going up in my attic and checking my GFI to see if that is why my radon mit fan is "broken" .Im probably not that lucky but worth a try. Thanks for your help!!!!
Thank you for the kind words, Jerry!
Thank you! This was the issue with mine! I was so close to calling the company to come and check the fan, but this video helped solve the problem!
Glad it helped!
Very helpful video
Glad to hear that!
Thank you so much for your videos. 😀 My fan got louder and louder over 2 weeks and now it just stopped. At first I didn’t even know what it was. I am concerned about radon in the house and not sure how fast levels get high in the house! I have no idea who to contact and have heard some people are not certified and charge too much. Can you guide me on who to contact? I wish you lived here!!! 😢 I am in North Carolina. Thanks!!
You're welcome! You can find a certified contractor here: nrpp.info/pro-search/
We also have a DIY radon fan replacement video that has replacement fans linked in the description if you'd like to do it yourself. czcams.com/video/qEADrgDg4kk/video.htmlsi=AR9_yB6237-UlRJK
I noticed a HRV/ERV on the furnace. Is that something you also do.
No, we leave those to the HVAC guys.
Do you know the brand of that sump pit cover with window?
I do not. However, I would not recommend getting one. They are pretty flimsy and do not create an airtight seal.
I do see the Jackel brand periodically. amzn.to/40FytHu
How does a fireplace lit in the basement affect radon gas Will it draw out the gas
I would imagine that it could increase the stack effect, thus increasing your radon levels. It would be a good experiment to try if you had an EcoQube or similar way to measure radon levels.
How does a fireplace lit in the basement affect radon gas Does it draw it out
I imagine it would increase the stack effect, thereby increasing the radon levels in your home. It would be a good experiment for you to run if you have a radon monitor like the EcoQube.
Where do I begin? Had system installed 14 years ago & it still runs but have done nothing to it. I checked radon level a few years back & it was in acceptable range.
Ginni, you should test your radon level every two years. We like the EcoQube as a way to track your long-term radon levels and receive up-to-date data. You can check the EcoQube out by visiting americanradonmitigation.com/product/ecoqube/
My GFI tripped, reset, unplugged the radon system and it immediately trips. tried plugging it into another GFI outlet with extension cord and it immediately trips. Have it plugged into a non GFI and it is running now...could it be a fan issue or what is causing the trips
Good question. I'd ask an electrician. I'd be interested to hear what caused it when you find out.
Were you able to figure the issue?
Had the same issue though intermittently, and radon folks switched it to another breaker. Unfortunately, then the fan just ran intermittently. Radon folks are still trying to figure it out though i'm wondering if there was water damage initially and it needs to be replaced. If you figured out your issue, would love to know.
would heated floors in the basement cause a stack effect? our heated floor rooms have far higher radon levels than the others
That's a good question! Does your entire basement have heated floors?
@@AmericanRadonMitigation just half of it and those rooms are about 2.5x higher.
may I also ask if a professionally speed controller should be able to over volt a radon fan? Ive recently moved in and turned it up on the dial because levels are rising and the fan got hot and has just died!
@03056932 Interesting. Try turning the heat off in those rooms to see if it makes a difference. Or, if you have more than one radon monitor, turn the heat off in one room and compare the results.
I've never used a speed controller, just EC fans with a potentiometer, which allows you to adjust the fan's speed.
You can find these at radonpds.com/product-category/radon-fans/radon-fans-high-volume/
Use promo code Jesse if you'd like to save a bit.
@@AmericanRadonMitigation I will and I will check those fans out. thankyou ever so much for replying
@@03056932 you betcha!
yeah, insolate all those pipes as cold air will cause condensation and then mold...
Insulate all the PVC pipes in the attic, walls, and floor trusses?
@@AmericanRadonMitigation Only if there is cold air flowing thru.
My brother opened the fan and found a dead mouse
I told my nephew that, and he said gross!