Dead Radon Fan? Check This Before Calling Your Mitigation Company

Sdílet
Vložit
  • čas přidán 2. 08. 2024
  • Has your radon fan stopped working? If so, be sure to check your GFCI outlet first.
    We went out to this Prior Lake, MN home because the homeowner noticed that the U-tube manometer was reading zero. She assumed their radon fan needed to be replaced.
    When I went into the attic to see what fan they had, I noticed that the GFCI outlet had tripped. All I needed to do was push the reset button on the outlet. You probably have an outlet just like this in your bathroom.
    Check out our playlist on troubleshooting radon mitigation systems. • Troubleshooting Radon ...
    Links:
    We earn a commission if you purchase using the links.
    RadonAway Radon Fans
    RP140 - amzn.to/3s0avdn
    RP145 - amzn.to/45iItIv
    RP260 - amzn.to/3QqXq78
    RP265 - amzn.to/3OP8v0w
    RP380 - amzn.to/3OppAgd
    XP151 - amzn.to/444AwW6
    XP201 - amzn.to/3Yv6aLe
    XR261 - amzn.to/3OOkPhx
    GX3 - amzn.to/3Yr2c6u
    GX4 - amzn.to/43WsOgQ
    GX5A -amzn.to/451PBJp
    GP301 - amzn.to/3QrUreE
    GP501 - amzn.to/3KynNUJ
    SF180 - amzn.to/47o02IY
    Fantech Radon Fans
    Rn1 - amzn.to/3DL0weJ
    Rn2 - amzn.to/3Ot86iT
    Rn2EC - amzn.to/45niJum
    Rn3 - amzn.to/3KA2NwT
    Rn4EC - amzn.to/446RTpo
    AMG Festa Radon Fans
    Spirit - amzn.to/43YOl8B
    Maverick - amzn.to/44abEww
    Hawk - amzn.to/3s70c7p
    Legend - amzn.to/3OwgVZp
    Prowler - amzn.to/3DMOSzI
    Eagle - amzn.to/44ZwT5m
    Eagle Extreme - amzn.to/3Kvthja
    Radon Fan Cord - amzn.to/3DOzanT
    Rubber Couplers - amzn.to/441AO07
    Radon Test Kit - amzn.to/440t3rd
    Radon Monitor - amzn.to/3Qxjmxx
    Check out the @radonaway3614 fan selection guide: www.radonaway.com/pdfs/radon-...
    PDS Radon Supply sells RadonAway and Fantech radon fans; Use promo code JESSE for 5% off your first order. radonpds.com/product-category...
    Frequently used products:
    Ecosense Radon Monitors: Use promo code ARM to receive a discount ecosense.io/ARM
    TEC DG-8: store.energyconservatory.com/... TEC Fog Puffer: store.energyconservatory.com/...
    Radon Sealant - amzn.to/2Mu6yZv
    Milwaukee Super Hawg Drill - amzn.to/32m67sk
    Milwaukee 16’ Autolock Tape Measure - amzn.to/3ouZFXQ
    Bosch 5-Inch Core Bit - amzn.to/36ik4Xw
    • How Do You Wire a Fant...
    • How to Wire Festa AMG ...
    • Loud Radon Fan? How to...
    • How to Replace a Radon...
    Get an Estimate (within an hour of the Twin Cities, MN metro area.) americanradonmitigation.com/f... or call 612-474-1004
    If you live outside our service area, check out our virtual consulting services at americanradonmitigation.com/c...
    For basic questions, leave a comment, and we'll try to answer when we have the chance.
    Thank you so much for watching!
    Roadtrip by Scandinavianz / scandinavianz
    Creative Commons - Attribution 3.0 Unported - CC BY 3.0
    Free Download / Stream: bit.ly/l-roadtrip
    Music promoted by Audio Library • Roadtrip - Scandinavia...

Komentáře • 36

  • @AmericanRadonMitigation
    @AmericanRadonMitigation  Před 10 měsíci

    Replacement radon fans are linked below.

    RadonAway Radon Fans
    RP140 - amzn.to/3s0avdn
    RP145 - amzn.to/45iItIv
    RP260 - amzn.to/3QqXq78
    RP265 - amzn.to/3OP8v0w
    RP380 - amzn.to/3OppAgd
    XP151 - amzn.to/444AwW6
    XP201 - amzn.to/3Yv6aLe
    XR261 - amzn.to/3OOkPhx
    GX3 - amzn.to/3Yr2c6u
    GX4 - amzn.to/43WsOgQ
    GX5A -amzn.to/451PBJp
    GP301 - amzn.to/3QrUreE
    GP501 - amzn.to/3KynNUJ
    SF180 - amzn.to/47o02IY
    Fantech Radon Fans
    Rn1 - amzn.to/3DL0weJ
    Rn2 - amzn.to/3Ot86iT
    Rn2EC - amzn.to/45niJum
    Rn3 - amzn.to/3KA2NwT
    Rn4EC - amzn.to/446RTpo
    AMG Festa Radon Fans
    Spirit - amzn.to/43YOl8B
    Maverick - amzn.to/44abEww
    Hawk - amzn.to/3s70c7p
    Legend - amzn.to/3OwgVZp
    Prowler - amzn.to/3DMOSzI
    Eagle - amzn.to/44ZwT5m
    Eagle Extreme - amzn.to/3Kvthja
    Radon Fan Cord - amzn.to/3DOzan
    As an Amazon Associate, we earn from qualifying purchases.

  • @whocares0316
    @whocares0316 Před rokem +1

    You are an honest contractor....almost an oxymoron these days. From watching this video i am going up in my attic and checking my GFI to see if that is why my radon mit fan is "broken" .Im probably not that lucky but worth a try. Thanks for your help!!!!

  • @ZenCloud9
    @ZenCloud9 Před 11 měsíci

    Thank you! This was the issue with mine! I was so close to calling the company to come and check the fan, but this video helped solve the problem!

  • @mobihaque7037
    @mobihaque7037 Před 3 měsíci

    Very helpful video

  • @morninggloryfarmstead
    @morninggloryfarmstead Před 11 měsíci

    Thank you so much for your videos. 😀 My fan got louder and louder over 2 weeks and now it just stopped. At first I didn’t even know what it was. I am concerned about radon in the house and not sure how fast levels get high in the house! I have no idea who to contact and have heard some people are not certified and charge too much. Can you guide me on who to contact? I wish you lived here!!! 😢 I am in North Carolina. Thanks!!

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 11 měsíci

      You're welcome! You can find a certified contractor here: nrpp.info/pro-search/
      We also have a DIY radon fan replacement video that has replacement fans linked in the description if you'd like to do it yourself. czcams.com/video/qEADrgDg4kk/video.htmlsi=AR9_yB6237-UlRJK

  • @ianpalmer1482
    @ianpalmer1482 Před 3 lety

    I noticed a HRV/ERV on the furnace. Is that something you also do.

  • @lakebummer
    @lakebummer Před rokem

    Do you know the brand of that sump pit cover with window?

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před rokem

      I do not. However, I would not recommend getting one. They are pretty flimsy and do not create an airtight seal.
      I do see the Jackel brand periodically. amzn.to/40FytHu

  • @duanelundell4257
    @duanelundell4257 Před 2 lety

    How does a fireplace lit in the basement affect radon gas Will it draw out the gas

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 2 lety

      I would imagine that it could increase the stack effect, thus increasing your radon levels. It would be a good experiment to try if you had an EcoQube or similar way to measure radon levels.

  • @duanelundell4257
    @duanelundell4257 Před 2 lety

    How does a fireplace lit in the basement affect radon gas Does it draw it out

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 2 lety

      I imagine it would increase the stack effect, thereby increasing the radon levels in your home. It would be a good experiment for you to run if you have a radon monitor like the EcoQube.

  • @ginni333
    @ginni333 Před 2 lety

    Where do I begin? Had system installed 14 years ago & it still runs but have done nothing to it. I checked radon level a few years back & it was in acceptable range.

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 2 lety

      Ginni, you should test your radon level every two years. We like the EcoQube as a way to track your long-term radon levels and receive up-to-date data. You can check the EcoQube out by visiting americanradonmitigation.com/product/ecoqube/

  • @jimothyjams443
    @jimothyjams443 Před 2 lety

    My GFI tripped, reset, unplugged the radon system and it immediately trips. tried plugging it into another GFI outlet with extension cord and it immediately trips. Have it plugged into a non GFI and it is running now...could it be a fan issue or what is causing the trips

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 2 lety

      Good question. I'd ask an electrician. I'd be interested to hear what caused it when you find out.

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 2 lety

      Were you able to figure the issue?

    • @croutonMangle
      @croutonMangle Před 2 lety

      Had the same issue though intermittently, and radon folks switched it to another breaker. Unfortunately, then the fan just ran intermittently. Radon folks are still trying to figure it out though i'm wondering if there was water damage initially and it needs to be replaced. If you figured out your issue, would love to know.

  • @03056932
    @03056932 Před 11 měsíci

    would heated floors in the basement cause a stack effect? our heated floor rooms have far higher radon levels than the others

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 11 měsíci

      That's a good question! Does your entire basement have heated floors?

    • @03056932
      @03056932 Před 11 měsíci

      @@AmericanRadonMitigation just half of it and those rooms are about 2.5x higher.
      may I also ask if a professionally speed controller should be able to over volt a radon fan? Ive recently moved in and turned it up on the dial because levels are rising and the fan got hot and has just died!

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 11 měsíci

      @03056932 Interesting. Try turning the heat off in those rooms to see if it makes a difference. Or, if you have more than one radon monitor, turn the heat off in one room and compare the results.
      I've never used a speed controller, just EC fans with a potentiometer, which allows you to adjust the fan's speed.
      You can find these at radonpds.com/product-category/radon-fans/radon-fans-high-volume/
      Use promo code Jesse if you'd like to save a bit.

    • @03056932
      @03056932 Před 11 měsíci

      @@AmericanRadonMitigation I will and I will check those fans out. thankyou ever so much for replying

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 11 měsíci

      @@03056932 you betcha!

  • @andecap1325
    @andecap1325 Před 2 lety +1

    yeah, insolate all those pipes as cold air will cause condensation and then mold...

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 2 lety

      Insulate all the PVC pipes in the attic, walls, and floor trusses?

    • @andecap1325
      @andecap1325 Před 2 lety

      @@AmericanRadonMitigation Only if there is cold air flowing thru.

  • @koalabear8480
    @koalabear8480 Před 2 lety

    My brother opened the fan and found a dead mouse