ANG MGA DAPAT MALAMAN NG MGA ELECTRICIAN. TUNGKOL SA LINE to NEUTRAL at LINE to GROUND AT SWER

Sdílet
Vložit
  • čas přidán 25. 09. 2020
  • From an ENGINEER TECHNICAL BRAINSTORMING VIEWPOINT
  • Věda a technologie

Komentáře • 55

  • @romeryalung1215
    @romeryalung1215 Před 2 lety

    Sana all engr

  • @orlandocabugoy8211
    @orlandocabugoy8211 Před 3 lety

    Eto ang hinahanap q legit channel . Very informative lalo na sa tulad q nagsearch at nag aaral sa electrical matters. Tnxs sir keep it up.

  • @crisnahial5119
    @crisnahial5119 Před 2 lety

    new subscriber here..

  • @edmark27
    @edmark27 Před 3 lety +2

    Salamat sir sa npakagandang info, makakatulong sa mga mag-aaral, baka matutulungan mo po ako Engr para sa Learning Materials/Resources para po sa training ng Senior High

  • @romeryalung1215
    @romeryalung1215 Před 3 lety +1

    Gandang araw po engr dami pong matutuhan sa CZcams channel nio thanks po

  • @markanthonygeraldo583
    @markanthonygeraldo583 Před 3 lety +1

    Happy birthday po sa wife nyo and happy anniversary sa inyo engineer. Salamat po sa pag share ng video. Additional po sa akin ito

  • @BarkoTv
    @BarkoTv Před 3 lety +1

    dito na ako sir.salamat sa pag share ng knowledge.sana maka pasyal ka din sa bha.y

  • @benedictoburbos8156
    @benedictoburbos8156 Před 3 lety +1

    Sir happy anniversary go go celtics or miami more video god bless u

  • @renechavez8275
    @renechavez8275 Před 3 lety +1

    Dagdag kaalaman sir salamat master

  • @paulseimonpuertillano9075

    thank you sir... stock knowledge naman...stay safe and God bless

  • @roelaquino3079
    @roelaquino3079 Před 3 lety +1

    New subscriber po sir! Slmt..

  • @boybravo689
    @boybravo689 Před 2 lety

    Sir ask ko lng pwede bang mag bond sa panel board ang neutral at grounding conductor tnx po

  • @caipelone2386
    @caipelone2386 Před 3 lety +1

    Sir pashout out din po kame! :D

  • @jonjon3687
    @jonjon3687 Před 3 lety +1

    Thank you po sir for your sharing of knowledge and experiences po on the matter. Sir tungkol dun s line to neutral bonded to ground n inaaply s mga probinsya at sa image n pniresent nyu, iclarify ko lang po kung hindi po b bonded ang neutral s GEC?

  • @AyingaN
    @AyingaN Před 3 lety +1

    More power to you sir 👍🏼👍🏼👍🏼

    • @engrjunogarte9844
      @engrjunogarte9844  Před 3 lety +1

      Thanks sir

    • @AyingaN
      @AyingaN Před 3 lety

      Sir sana makagawa ka rin about single phase transformer bankings.

    • @engrjunogarte9844
      @engrjunogarte9844  Před 3 lety +1

      @@AyingaN meron na ako nyan. Punta ka youtube channel ko. Hanapin mo ang 3 phase banking transformer calculation

    • @AyingaN
      @AyingaN Před 3 lety

      Ok sir salamat po

  • @alexisreyes601
    @alexisreyes601 Před 2 lety

    Idol pag line to neutral ba,kaylangan ko pa maglagay Ng ground connect.sa outlet

  • @robertobarredo2555
    @robertobarredo2555 Před 2 lety

    Sir tanung lng po kung ang mcb kopo ay 40amp at maglalagay poko ng 3pcs na 30amp para sa spo at 3 20apm sa co at 3 15amp para sa ilaw po at ang wire kopo ay #8 thhn po kaya poba un load po ty

  • @markanthonygeraldo583
    @markanthonygeraldo583 Před 3 lety +1

    Sir tanong lng po kung ang panel po walang naka lagay na grounding. Lalo na po sa mga lumang bahay. Pwede po ba na lagyan lng ng grounding ung malapos sa appliances. Example po ung oven or ref. ? Lagyan nlng ng grounding rod for safety purposes.
    Salamat po sa sagot

    • @engrjunogarte9844
      @engrjunogarte9844  Před 3 lety +1

      Walang epekto yan sa panel mo kung walang egc o ground ang circuit mo. Puedi kang makuryente

  • @dennislopez9517
    @dennislopez9517 Před 3 lety

    Salamat sir sa sharing knowledge. Piro bakit po kaya ganun ang implementation ng energy provider sa probinsya pag padating consumer kahit walang grounding ok lang diba dapat sa seminar palang bago makabitan ang consumer ay dapat may topic na sila sa grounding kung gano kahalaga ng grounding lalo na sa mga consumer. At dahil po nga sa sinasabi na line to grounding. Gusto ko lang po lumawak pa kaalaman ko..

    • @engrjunogarte9844
      @engrjunogarte9844  Před 3 lety +1

      Ang grounding sa mga enduser ay kanilang responsibility na maglagay ng ground wire sa service entrance nila. Ang DU ang mag provide ng termination or splicing ng ground wire sa service entrance.

    • @opecons
      @opecons Před 3 lety

      Dapat ang electrician na nag install ng wiring , responsible niya na maglagay ng grounding. At ang OBO/EE sa lugar sana ang magcheck kun kumpleto ang ginawa ng electrician. Ang provider lang ang magkabit o magbigay ng supply. Tama ho ba engr?

  • @haridfabiala103
    @haridfabiala103 Před 2 lety

    mliit Ang picture d masyado Makita.

  • @kitkirkyen2002
    @kitkirkyen2002 Před 3 lety

    Engr Jun, dito sa amin sa mindanao line to grounded neutral ang system sa 1-phase. Case is in the first main disconnect after the service meter, 2 pole breaker ang gagamitin kaya pumasok si phase and neutral sa line side and doon sa load side lumabas ang dalawang wires which in turn the grounding and bonding occurs at that load side of the panel. Can u share your technical idea if this is ok engr jun? Tama lang po ba na ma daan si neutral conductor sa CB bago natin i bond sa equipment? Thank you so much.

    • @engrjunogarte9844
      @engrjunogarte9844  Před 3 lety

      Tama. Puedi mag 2P breaker sa main disconnect after the breaker. Compliant sa PEC yan for a L-N single Ph system. Mag hihiwalay lang ang Line at Neutral sa sub panel DB.

    • @russellteejaymolina6736
      @russellteejaymolina6736 Před 3 lety

      Same case po dito sa north luzon, phase to grounded neutral din setup ng mga local electric coop dito. pumasok ang phase at si grounded neutral sa 2 pole circuit breaker. ok lang ba na i jumper si grounded neutral sa panel grounding busbar, at si panel grounding busbar naman ay connected din sa gounding rod ng bahay.. Kong pwede po yong ganong setup, saan kaya naman ang best tapping point, sa source side mg main breaker kaya or sa load side ng main circuit breaker. This is to utilized the grounding safety feature ng mga outlet na three prong, kong sakaling magkaroon ng earth fault sa mga metalic body appliances para may return path pa rin si fault current papuntang source via appliance ground conductor- to- panel grounding busbar-to-jumper cable connection to grounded neutral and back to secondary side of the distribution transformer and finally triping the branch circuit breaker or yong main circuit breaker sa panel distribution box.. Salamat po.

  • @macmartinez5003
    @macmartinez5003 Před 3 lety

    Hello sir. May power pa rin po ba kahit walang neutral na kasama sa service wire? Ano pong disadvantage?

    • @engrjunogarte9844
      @engrjunogarte9844  Před 3 lety

      Line to neutral ay active ang 2 line na yan. Iyan ang mag su supply ng power sa load mo. Kung wala kang neutral wala kang supply.

  • @alexanderdavid2488
    @alexanderdavid2488 Před 3 lety +1

    Sir jun, safe po bang gamitin ang live and earth ground pr makagawa ng 110volts at magamit s 110volts n aircon. Pls back tnx

    • @engrjunogarte9844
      @engrjunogarte9844  Před 3 lety

      Hindi mo bro. Kc ang earth ay mataas ang resistance. Pag nagka roon ng short circuit hindi mag ti trip ang breaker

  • @alvinlenoa5598
    @alvinlenoa5598 Před 3 lety +1

    Sir anu po yang sa diagram po my jumper po ba ang terminal log ng ground to neutral po.baguhan lang po aq taga subaybay nio.tnx

  • @juanchoregondola1882
    @juanchoregondola1882 Před 3 lety

    Engineer, tanong ko lang po. Ano mainam na gawin kung yung ilaw ko nag fflicker every time na paandarin ko pressure washer ko? Relay po ba solution?

  • @markfrancisbaroquillo4865

    Sir paanu po ba maging isang master electrician

    • @TagalogElectricaltips
      @TagalogElectricaltips Před 3 lety

      kailangan mong mag exam sa professional Regulations commission. check mo website nila para sa mga requirements. salamat

  • @i.p.0179
    @i.p.0179 Před 3 lety +1

    Ang neutral po ay yung wire na dadaanan ng kuryente pabalik para magkaroon ng complete circuit. Ito ay current carrying conductor at normal condition. Ang ground naman ay safety path in case magkaroon ng live wire. It is not a current carrying conductor under normal condition. In case mahawakan ang live wire di ka makukuryente kasi sa ground dadaan yun current. Tama po ba?

    • @engrjunogarte9844
      @engrjunogarte9844  Před 3 lety

      Ang neutral ay pueding current carrying at hindi current carrying conductor. Try to check back may video ang reason behind. Thsnks sir

  • @jbm9307
    @jbm9307 Před 3 lety

    Engr. Jun, pareview at pacomment po ng video link sa ibaba, dun po sa part ng video about sa connections from meter base to panel board. Sabi po kasi dito, hindi bina-bong yung neutral to ground. Thank you po.
    czcams.com/video/O3LrPzhB5Bg/video.html

    • @paoloflorentin1237
      @paoloflorentin1237 Před 3 lety

      yes tama. need mo ibond ang neutral (grounded conductor) to equipment grounding conductor. plus need mo din ikonekta ito sa grounding electrode (rod) through grounding electrode conductor (GEC). ito ay regardless kung 1 phase 3 wires or 1 phase 2 wires.

  • @olijohveakjnk2258
    @olijohveakjnk2258 Před 3 lety +1

    haba ng intro