Honeywell T4R & T3R. 3 Ways to Wiring Up the Receiver Box. Also Cover Other Wireless Thermostats

Sdílet
Vložit
  • čas přidán 31. 07. 2024
  • 3 Ways to wire up a receiver box on a wireless thermostat.
    Specifically about Honeywell T4R and the T3R. Although most wireless receiver boxes wire up the same way.
    If you would like one of the thermostats you can click link below which will take you to Amazon.
    “As an Amazon Associate I earn from qualifying purchases.”
    Honeywell T3 Hard Wired Programmable Thermostat.
    www.markballard-ltd.com/recomm... (Amazon).
    Honeywell T3R Wireless programmable Thermostat.
    www.markballard-ltd.com/recomm... (Amazon).
    Honeywell T4 Hard Wired Programmable Thermostat.
    www.markballard-ltd.com/recomm... (Amazon).
    Honeywell T4R Wireless programmable Thermostat.
    www.markballard-ltd.com/recomm... (Amazon).
    I will explain in detailed step by step instructions.
    If you want to support me further then please leave a Donation in my “TOOL BOX FUND” that is really appreciated.
    www.paypal.com/donate/?cmd=_s...
    Please don’t forget to subscribe for more help videos.
    My site
    www.markballard-ltd.com/
    Links to my other videos.
    VIDEO: How to replace a leaking Radiator Valve. With out draining the system.
    • Replace Radiator Valve...
    Honeywell T4R Wireless Programmable Room Thermostat
    Sep-up, programming, operation and lots more.
    • Honeywell T4 & T4R. Ho...
    T3R verses the T4R head to head comparison.
    • Honeywell T3-T3R Compa...
    Honeywell T3R Wireless Programmable Room Thermostat.
    Sep-up, programming, operation and lots more.
    • How to USE, Program & ...
    Video: How to Factory Reset the Honeywell T3 and the T3R.
    • How to Reset the Honey...
    Honeywell T3R Re-Binding / Re-Pairing.
    • Honeywell T3R. Re-Bind...
    Honeywell T4R Re-Binding / Re-Pairing.
    • Honeywell T4R. Re-Bind...
    Replacing an old Honeywell CM927 with Honeywell T3R.
    • Honeywell CM927 Screen...
    VIDEO: How to replace a leaking radiator valve. With out draining the system: Part 1.
    • Replace Radiator Valve...
    VIDEO: How and Why you should add "INHIBITOR" to your heating system. Including "System Cleaner" and other "Chemicals"..
    • How and Why You Should...
    VIDEO: How to Replace a Radiator with Out Draining the System.
    • How to Replace a Radia...
    VIDEO: How to flush Out a Radiator. The Best Way, Getting the Best Results
    • How to flush Out a Rad...
    VIDEO: How To Remove a Olive, 5 Different Ways To Remove a Old Olive Off a Pipe
    • How To Remove a Olive,...
    VIDEO: How to Balance your Heating System to make it more efficient. Which will REDUCE YOUR GAS BILL.
    • How to Balance Your He...
    VIDEO: How to replace a Central Heating Pump. All you need to know. With out draining the system.
    • How to Replace Your Ce...
    VIDEO: How to clean the Magna Clean Professional 1
    • How to Clean the Adey ...
    VIDEO: How to Fix a Radiator NOT Getting Hot! Thermostatic Valve Stuck.
    • How to Fix Cold Radiat...
    VIDEO: How to Get a Radiator working and Hot Again, Everything I would do.
    • Everything You Can Do ...
    VIDEO: How to Install the Hive Thermostat Mini, Explained in Detail Wiring, Pairing, Factory Reset.
    • How to Install the Hiv...
    Chapters
    0:00 Intro
    1:59 Honeywell T4R Wiring. T3R & T4R differences.
    3:55 Honeywell T4R Wiring. Connections.
    7:17 Honeywell T4R Wiring. Wiring Live Neutral & Earth.
    8:58 Honeywell T4R Wiring. How not to wire up.
    9:10 Honeywell T4R Wiring. Clapping the Wires.
    10:45 Honeywell T4R Wiring. Switch Live Connection.
    12:07 Honeywell T4R Wiring. Low Volt Wiring Up.
    12:32 Honeywell T4R Wiring. 2 Three Core Flex Wires.
    14:02 Honeywell T4R Wiring. Wiring Up with Link Wire.
    17:10 Honeywell T4R Wiring. 1 Three Core Flex Only.
    18:07 Honeywell T4R Wiring. Wiring Up with 5 Core Flex.
    22:14 Honeywell T4R Wiring. Summing Up.
  • Krátké a kreslené filmy

Komentáře • 22

  • @faridratni6799
    @faridratni6799 Před 3 lety +11

    It's very nice video but I wish if you did show us how do you connect it to the boiler

  • @smithersjones3018
    @smithersjones3018 Před 2 lety

    A useful video. Thanks for putting it up.

  • @macmac6072
    @macmac6072 Před rokem +3

    Very well presented, but you have not showed the corresponding connections at the boiler

  • @Zirumaio
    @Zirumaio Před 8 měsíci

    I'm going to buy T4R and your description of remote actuator is precious to check is ok for my case. I appreciate it very much 👍

  • @akguest5551
    @akguest5551 Před 2 lety

    Awesome video

  • @simonboyes2550
    @simonboyes2550 Před rokem +2

    👍👍 Am thinking of trying this myself. The heating engineer who recommended the T4R has gone awol on me. The current thermostat is a Salus, which is dreadful....I've seen it referred to as a 'war crime'

  • @alfypierri8022
    @alfypierri8022 Před 3 lety +3

    Great video. Just missing the side of the boiler wiring up.

  • @billjohns9488
    @billjohns9488 Před 3 lety +2

    Could you do a video on wiring up a T4 programmable thermostat.

  • @annedobree1444
    @annedobree1444 Před 5 měsíci

    Hello - if you have a link wire set up, is there any minimum weight/size for the link wire? thank you

  • @alansiggers6257
    @alansiggers6257 Před 2 lety +1

    Is the wiring the same for a Combi boiler please.

  • @Chris-vc1dh
    @Chris-vc1dh Před 2 měsíci

    I have live and neutral as power supply then live and neutral as boiler supply and 2 wires as switch

  • @justsomeothername
    @justsomeothername Před 10 měsíci

    Very nice video but I would like to connect the thermostat via the Opentherm protocol. From what I read in the specs that should be possible with the T4R, so I don't understand why you are saying that the OT connectors are for a different thermostat. Can you explain it to me?

  • @gjmheating8857
    @gjmheating8857 Před rokem

    hi Mark can you use t3r rf on old DT900 receiver

  • @Avm1984
    @Avm1984 Před 6 měsíci

    Can I fit the receiver further than 300mm my existing thermostat is 2m away

  • @makinote
    @makinote Před 2 lety

    I have a T4R but the receiver is failing to work. Is a T3R receiver compatible with the T4R transmitter? thx :)

  • @4amenah
    @4amenah Před rokem

    Hi, can you do a video on the Salus r

  • @KevinHewitt-hm3dz
    @KevinHewitt-hm3dz Před rokem

    Could you show how to wire up a T3 replacement thermostat from a dial unit?

  • @petinyiri
    @petinyiri Před rokem

    hi there, I have a ST9400C programming unit, and I am trying to replace my old hcw80 wireless thermostat and receiver, with a newer DT90e in the old receiver have a 5 wiring which are (Blue wired in N, then the brown wired in the L (2nd) then I have a black wire which wired in to A, then a grey wired into B and then the earth wired into the E, , do I follow the same with the new receiver dt90e ? if so where do I connect the earth as on the new dt90e there is no E (mark) only C, in the new receiver dt90e I have a NLL then ABC , any advice? thanks

  • @Chris-vc1dh
    @Chris-vc1dh Před 2 měsíci

    so there is 240v supply but no 240v going to boiler/?

  • @shanksgaming2827
    @shanksgaming2827 Před rokem

    Didn't you forget to bring Earth, neutral + Line to the receiver from the spur?

  • @imtitsupdickielala12
    @imtitsupdickielala12 Před 9 měsíci

    Hi, great video. Could be a daft Question but i have the 4r would that connect to a hive thermostat?. Thanks