That’s actually a medium pressure system , high pressure is 5 lbs. they won’t supply that to residential except for special applications. You can run 2lbs thru a house and use several different ventless regulators on manifolds to catch the house appliances. I’ve done this many times on big houses with tankless water heaters, to save running 11/2” or 2” screw pipe
Thank you
That’s actually a medium pressure system , high pressure is 5 lbs. they won’t supply that to residential except for special applications. You can run 2lbs thru a house and use several different ventless regulators on manifolds to catch the house appliances. I’ve done this many times on big houses with tankless water heaters, to save running 11/2” or 2” screw pipe
if its a 2 # system the dial on the meter needs too be red too compensate for 2#