How to calculate the load in slabs and beams? | Load transfer mechanism in building | Civil Tutor

Sdílet
Vložit
  • čas přidán 29. 06. 2024
  • Download our android app for job oriented courses
    clpsheldon.page.link/x3kb
    In this lecture, I have discussed briefly how to calculate the load in slabs and beams and the load transfer mechanism behind it.
    Compiled PDFs👇
    store.civiltutorofficial.com
    For any framed structure, the total load of a slab includes the Live Load, Floor finishing Load, and the self-weight of the slab. This load is transferred to the beams which provide support to the slab, and from the beams, the load is transferred to the supporting columns. Then from columns to the footings and finally to the soil on which the whole structure is constructed.
    The total load of a slab is the summation of the Dead load and the Live Load. The dead load includes the self-weight of the slab plus the floor finish and it is to be calculated as per IS 875 part 1.
    Must-have books for civil engineers 👇🏽
    The A to Z of Practical Building Construction and Its Management
    amzn.to/3HKmjm9
    Building Planning and Drawing
    amzn.to/3sPztdA
    Illustrated Design of Reinforced Concrete Buildings ( Design of G+3 Storeyed Buildings + Earthquake Analysis & Design)
    amzn.to/3tD9aGq
    Advanced Reinforced Concrete Design
    amzn.to/3IRZwGn
    Limit State Design of Steel Structures
    amzn.to/3pIk1O6
    Estimating and Costing in Civil Engineering (Theory and Practice)
    amzn.to/3IWcwLq
    The mic I use👇🏽
    amzn.to/35ejhcN
    #rccdesign #civiltutor #loadcalculation
    ►DISCLAIMER
    The information provided in this video is for educational purposes only. The viewer is solely responsible for verifying the information and the use of the information in this video is at the viewer's own risk. The content is not intended to be used for professional or commercial purposes. The application of the information presented in this video on a construction site should be carried out only by a licensed and qualified civil engineer.
    This video may contain copyrighted material the use of which has not been specifically authorized by the copyright owner. However, under Copyright Disclaimer under Section 107 of the Copyright Act 1976, allowance is made for fair use for purposes such as criticism, comment, news reporting, scholarship, and research. Fair use is a use permitted by copyright statute that might otherwise be infringing. Non-profit, educational or personal use tips the balance in favor of fair use.

Komentáře • 68

  • @markdilannyuykonge330

    I love the way you made your video and how straight forward it was I understand it so easily thanks

  • @gopalmalapati1446
    @gopalmalapati1446 Před 10 měsíci +2

    Gentle man, excellent explanation, hats off to you.

  • @CivilTutor
    @CivilTutor  Před 2 lety +1

    Check out my Compiled PDF
    👇👇👇
    store.civiltutorofficial.com

  • @CivilTutor
    @CivilTutor  Před 2 lety +9

    There is an error in the calculation.... You can find the rectified calculation here 👇
    drive.google.com/file/d/1X5OFsa0rTTTqMrlf4aTz4SmlJiYIJARi/view?usp=sharing
    Sorry for the error🙏

  • @phyohtetkoko929
    @phyohtetkoko929 Před 2 lety

    Thanks For Teaching Sir

  • @axatrathod
    @axatrathod Před 2 lety

    Awesome sir 👌🏼👌🏼

  • @clifforddevoe919
    @clifforddevoe919 Před 4 měsíci

    Thank you bro, just freaking thank you😢😢

  • @darshanshrestha545
    @darshanshrestha545 Před 2 lety +7

    Your teaching is like academic. I’m enjoying; thank you!!
    Can you also teach how to calculate load on columns?

    • @CivilTutor
      @CivilTutor  Před 2 lety +2

      Sure

    • @EngineeringTech_Civil
      @EngineeringTech_Civil Před 2 lety

      IS-1200 part-01 all clause of earth work measurement .
      IS-1200 part-01 के सभी क्लॉज इस वीडियो में ।।
      czcams.com/video/zSDyKHKa3xo/video.html

  • @BRane-mo9wx
    @BRane-mo9wx Před rokem

    Superb sir

  • @gowthamiv4841
    @gowthamiv4841 Před 2 lety

    Worth watching..

  • @dreampannu2198
    @dreampannu2198 Před 10 měsíci +1

    great 🤩 truely said, i love to listening this, but i didn't like this for 1day, in the my 4years of college life 😅😇 thank you for this😍

  • @vishakhakale8181
    @vishakhakale8181 Před rokem +6

    Can u please recheck the formula u use for calculating the load due to trapazoidal section on beam.. Load calculated are very large

  • @travelguide786
    @travelguide786 Před 2 lety +1

    Ok, reminder set

  • @engrxiddig
    @engrxiddig Před 2 lety

    Good 👍

  • @AlAl-cr7ig
    @AlAl-cr7ig Před rokem

    Thank you

  • @mgovindaraju8034
    @mgovindaraju8034 Před 2 lety

    Thanks for sharing

    • @EngineeringTech_Civil
      @EngineeringTech_Civil Před 2 lety

      IS-1200 part-01 all clause of earth work measurement .
      IS-1200 part-01 के सभी क्लॉज इस वीडियो में ।।👍👍
      czcams.com/video/zSDyKHKa3xo/video.html

  • @nasirafridi6013
    @nasirafridi6013 Před 2 lety

    Thank you 💗

    • @EngineeringTech_Civil
      @EngineeringTech_Civil Před 2 lety

      IS-1200 part-01 all clause of earth work measurement .
      IS-1200 part-01 के सभी क्लॉज इस वीडियो में ।।
      czcams.com/video/zSDyKHKa3xo/video.html

  • @abdulmonimmohamedali9146

    Actually l want to thank you very much .

  • @dashtyswara3277
    @dashtyswara3277 Před dnem

    Thanks

  • @suryasekharlagudu4794
    @suryasekharlagudu4794 Před 2 lety

    Thank you 🙏

  • @EngineeringTech_Civil
    @EngineeringTech_Civil Před 2 lety +1

    Nice video 👍👍👍

  • @mbabazirodney2064
    @mbabazirodney2064 Před 20 dny

    What does 1-1 mean. Thanks for teaching

  • @amit95gupta
    @amit95gupta Před rokem +1

    THANKS SIR, BUT ONE THING I AM MENTIONING THAT LOAD ON BEAM B6 AND B4 DUE TO BEAM B5 SHOULD BE POINT LOAD,BUT YOU HAVE CONSIDERED AS UDL 33KN/M.

  • @ibby3849
    @ibby3849 Před rokem

    hey how did you work out the area of the cross section it says 0.23 but not sure how you got this

  • @ihsanullah6479
    @ihsanullah6479 Před 2 lety +2

    Thanks.how to draw this in which software?

  • @meow0808
    @meow0808 Před rokem

    Thanks souch

  • @vedprakashthakur9175
    @vedprakashthakur9175 Před rokem

    could u pls tell me sir how to get the formula of. load on B1 due toslab S1

  • @abdulzahiraliyi8675
    @abdulzahiraliyi8675 Před rokem +2

    my question is, after we calculate loads on the beam can we use this load for column design or de we have to do another calculation using approximate area method for loads on the column ?

    • @OGTennyson
      @OGTennyson Před 11 měsíci +3

      Another calculation will be done

  • @engrxiddig
    @engrxiddig Před 2 lety

    Please sir make detailing using Autocad

  • @sangwoo218
    @sangwoo218 Před rokem

    How to calculate if i have water load on all area of slab ?

  • @balabyekubojohnchristom241

    What is the formula for getting number of bars from area of steel according bs8110 for Fy=410, Fcu= 20, Because BS8110 part 3 doesn't have table for suchcases.

  • @pranotostb
    @pranotostb Před 2 lety

    Good animasi

  • @sharmakeabdullahicisman4396

    Sir thank you
    i wanna how to calculate cantilever slab carreid load and transver to the beam

  • @shaahidebrahim9968
    @shaahidebrahim9968 Před 2 lety

    Thank you sir, tutorial on load transferred to column?

    • @CivilTutor
      @CivilTutor  Před 2 lety +2

      Will upload soon

    • @EngineeringTech_Civil
      @EngineeringTech_Civil Před 2 lety

      IS-1200 part-01 all clause of earth work measurement .
      IS-1200 part-01 के सभी क्लॉज इस वीडियो में ।।
      czcams.com/video/zSDyKHKa3xo/video.html

  • @ibby3849
    @ibby3849 Před rokem

    hey im a little unsure on something what if the design i have doesnt have beams every side for example my design it has beams only on 2 sides of the inividual structure

    • @ibby3849
      @ibby3849 Před rokem

      for example i have a b2 and a b1 but no beams on b6 and b7

  • @baberkhan-lt8br
    @baberkhan-lt8br Před rokem

    Load due to B5 on B6 will not be UDL as its one end is resting on B6 so it will apply point load on it there.. isn't it?

  • @THEONEPERCENTCLUB101
    @THEONEPERCENTCLUB101 Před rokem

    In minutes 8.06 , the load on B3 due to slab S2 = WLx/2 right but why isnt it 2.5 cause the length in beam B3 has a length of 2.5 m. should i substitute ( WLx/2.5 ) or is there anything else. thanks a lot for all this knowledge i am just a bit confused. thank you and have a great day.

    • @theandroidguy6032
      @theandroidguy6032 Před rokem +1

      It is one way slab and if the load is example 10kN/m2 The it has to distribute only on two equal beams hence divide by 2

  • @aravindhsuriyak.s6989
    @aravindhsuriyak.s6989 Před 2 lety +4

    Sir,Calculation can u make it as pdf and send it sir.. It's or all using for further calculations

    • @EngineeringTech_Civil
      @EngineeringTech_Civil Před 2 lety

      IS-1200 part-01 all clause of earth work measurement .
      IS-1200 part-01 के सभी क्लॉज इस वीडियो में ।।👍👍👍
      czcams.com/video/zSDyKHKa3xo/video.html

    • @mamteshmishra5609
      @mamteshmishra5609 Před 9 měsíci

      ​@@EngineeringTech_Civil4:32

  • @brahmaji0098
    @brahmaji0098 Před 2 lety

    Sir if we design 1st slab ..
    For the project of like g+5, g+6etc
    How can we take loads of remaining slabs which is the load transfer to 1 St slab
    Moreover is this for only for ground floor or g+1 ? Pl explain it sir
    Thank you

    • @CivilTutor
      @CivilTutor  Před 2 lety

      The example I have shown here is for a single storey frame to give you the basic idea of how load is transferred in a frame.... I will cover up for multiple stories in a separate video.

  • @joshuasolamo8697
    @joshuasolamo8697 Před rokem

    Hey guys how do you calculate square slab

  • @SumanDas-ey8ro
    @SumanDas-ey8ro Před 2 lety +2

    What is 1-1 ? How did you get the value, i.e., (1-1/2.1 = 0.523)???
    Please help 🥺

    • @CivilTutor
      @CivilTutor  Před 2 lety +4

      1 - (1/2.1) = 1 - 0.4761 = 0.523

  • @rajusimmanuel3285
    @rajusimmanuel3285 Před 8 měsíci

    Kindly the explanation shall be little slow

  • @dhanbiryadav3124
    @dhanbiryadav3124 Před 10 měsíci

    कोइ भि घरका सारा लोड, कलम के नम्बर मुताविक भाग लगाकर के निकाल सकते है और नहि?अगर नहि तो कैसे निकाले? please explain me.

  • @sekarramaswamy5111
    @sekarramaswamy5111 Před 2 lety

    Thanks for your design analysis… but the presentation to be modified with conclusions….

  • @pp238
    @pp238 Před 2 lety

    The last page calculation of the rectified calculation is again wrong. Again span of B4 (2.37+1.0) does not match with 3.6M of B1

    • @CivilTutor
      @CivilTutor  Před 2 lety +3

      Span of B4 = 2.37 + 1 + width of B5 (I.e, 0.23m) = 3.6 m

    • @pp238
      @pp238 Před 2 lety

      OK

  • @DarvaishBandah
    @DarvaishBandah Před 2 lety +3

    where did the size of beam and column come from? and do the beams and columns with this size resist the loads u calculated?
    sir make complete video of loads calculations from roof slab to foundation.

    • @sathyabalasundaram1801
      @sathyabalasundaram1801 Před 2 lety

      Refer below link
      czcams.com/video/NV5k1RjrPiM/video.html

    • @ygges3407
      @ygges3407 Před 2 lety +1

      it says "given specifications". So you can find the size of column and beams on the structural plan. But if you are the one designing it you will assume the sizes and solve for the whole design if it will (pass or fail) to carry your loads.