How to connect a Wired Outdoor Siren in an Ajax Alarm System

Sdílet
Vložit
  • čas přidán 28. 09. 2020
  • In today's episode i will show you how to add in an Ajax Alarm System a Wired Outdoor Siren.
    For this project i will use :
    1) a Wired Outdoor Siren
    2) Ajax Relay
    3) 12 Volts DC Power Supply
    Ajax Relay : ajax.systems/products/relay/
    Venitem Outdoor Siren : www.venitem.com/en/products/o...
    Other Ajax Step by Step Tutorials
    1) Ajax Smart Alarm - Step by Step Tutorial : • Ajax Smart Alarm - Ste...
    2) Ajax Motion Protect Curtain - Step by Step Tutorial : • Ajax Motion Protect Cu...
    3) Ajax Rex - Ajax Security System Radio Signal Range Extender : • Ajax Rex - Ajax Securi...
    4) Ajax Smart Alarm - Hub Plus - Testing Radio Signal using a Drone! : • Ajax Smart Alarm - Hub...
    Poseidwn Tech on Social Media:
    www.poseidwn.tech
    / poseidwn_tech
    / poseidwn.tech
    / poseidwn.tech
    / poseidwntech
  • Věda a technologie

Komentáře • 40

  • @sabinkolarov
    @sabinkolarov Před rokem +2

    Best solution will be with two relays in series. One using pulse and the other bistable mode. Pulse relay is activated on alarm and bistable on arm/disarm. One can deactivate a sounding external siren using bistable relay on/off switch.

  • @stratokrator
    @stratokrator Před 2 lety +1

    Venitem ;) Nice work there you should use a mini 12v dc ups for the siren and relay for not going offline or triggering the siren.

    • @PoseidwnTech
      @PoseidwnTech  Před 2 lety

      You're right! Thank you for your comment!

  • @MrTubertub
    @MrTubertub Před rokem

    Hello thanks for this video. Is it also possible to have the siren beep or make noise on set delay on DoorProtect? Would love to see more Ajax related content. Regards

  • @amirm1553
    @amirm1553 Před 2 lety

    How would the connection look like if you have two wires one 12v and one ground from the siren?

  • @delita93
    @delita93 Před rokem

    Hi, with jamming/interference/low signal , the siren will sound??

  • @houcineCCTV
    @houcineCCTV Před 3 lety +2

    Good idea but we have a problem
    if power supply has gone (110v or 220v) The device won't work.
    So I advise you to put the device inside the bell and take the power directly from battery

    • @PoseidwnTech
      @PoseidwnTech  Před 3 lety +1

      You are right about that but i believe that it is not a good idea to put Ajax Relay inside the Siren because you will have problem with it's signal and maybe with humidity since Relay is for indoor use. Maybe it will be better to plug the DC power supply of Relay into a small UPS.

  • @apkelesispre
    @apkelesispre Před 3 lety +2

    Καλησπέρα το μόνο θέμα ειναι ότι με αυτό το ρελε η σειρήνα χτυπάει απεριόριστα μέχρι να αφοπλιστει το σύστημα δεν έχει κάποια ρύθμιση για να σταματάει μετά από κάποιο χρονικό διάστημα. Σωστά?

  • @hotelamfilissos3121
    @hotelamfilissos3121 Před 5 měsíci

    Put the relay in the siren and powere it by the 12v battery. Less cables and "unlimited" backup power.

  • @nikos365a
    @nikos365a Před rokem

    Με το ρελαδακι μπορουμε να το ορισουμε βαζοντας στο pulse να χτυπαει για Χ χρονο. Τι γινεται ομως οταν θελουμε να σταματαει η σειρηνα και με αφοπλιση;

  • @sardinespiritpt4326
    @sardinespiritpt4326 Před 3 lety +1

    the triger should be normally close? so if any tamper it trigers the alarm?

    • @SurfThomasVD
      @SurfThomasVD Před 11 měsíci

      No tamper protection with this setup

  • @WD2266
    @WD2266 Před 2 lety

    Hi. The tamper with open siren and tear form the wall? Thanks...

    • @PoseidwnTech
      @PoseidwnTech  Před 2 lety

      You can connect siren tamper in a Door Protect sensor!

  • @stefanosiliadis8027
    @stefanosiliadis8027 Před 3 lety +1

    Με τη χρήση αυτού του ρελέ μπορούμε να συνδέσουμε και αισθητήρες άλλης εταιρίας ?

    • @PoseidwnTech
      @PoseidwnTech  Před 2 lety

      Για να συνδέσεις αισθητήρες θα χρειαστείς τον Ajax MultiTransmitter

  • @admin-security
    @admin-security Před 2 lety

    But if you open door protect when alarme is desarmed that will trigger the alarme too, no?
    Fox exemple if i put the ILS in the door and my alarme is off, by opening the door the siren goes on

    • @PoseidwnTech
      @PoseidwnTech  Před 2 lety +1

      For the alarm to be triggered you have first to arm. So if the system is armed and you open the door then the Siren will be activated.

    • @admin-security
      @admin-security Před 2 lety

      @@PoseidwnTech If the system is off and you open the door, will that triger the siren?

    • @PoseidwnTech
      @PoseidwnTech  Před 2 lety +1

      No it will not! The scenario is only "By Alarm".

    • @admin-security
      @admin-security Před 2 lety

      @@PoseidwnTech Thanks man, i will try it

  • @apanorgias
    @apanorgias Před 3 lety +1

    Καλησπέρα πάρα πολύ ωραία τα βίντεο σας σας ευχαριστούμε πολύ μας είναι πάρα πολύ χρήσιμα.
    Μία ερώτηση παρακαλώ μου πρόσφατα σύνδεσα και εγώ την παλιά μου ενσύρματη σειρήνα με το relay ajax. Έχω όμως μία απορία όταν κάποια στιγμή μπορεί να γίνει κάποια διακοπή ρεύματος χτυπάει συνέχεια η σειρήνα..
    Μήπως γνωρίζεις γιατί γίνεται αυτό και πως μπορώ να το σταματήσω να μη γίνεται;

    • @PoseidwnTech
      @PoseidwnTech  Před 3 lety +1

      Καλημέρα! Όταν η Σειρήνα ανιχνεύει απώλεια τάσης, τότε είναι λογικό να χτυπάει για λόγους ασφαλείας. Σε έναν συμβατικό συναγερμό στη διακοπή ρεύματος η σειρήνα δε χτυπάει γιατί είναι συνδεδεμένη στη κεντρική μονάδα του συναγερμού η οποία έχει εναλλακτική τροφοδοσία από μια μπαταρία. Οπότε στην περίπτωση του Ajax Relay θα πρέπει να συνδέσετε το τροφοδοτικό της Σειρήνας και του Relay σε ένα μικρό UPS, ή να προμηθευτείτε ένα τροφοδοτικό 12Volts με μπαταρία.

    • @apanorgias
      @apanorgias Před 3 lety

      @@PoseidwnTech Σας ευχαριστώ πάρα πολύ να είστε καλά

    • @PoseidwnTech
      @PoseidwnTech  Před 3 lety

      Και εσείς το ίδιο!

  • @vegasys2k
    @vegasys2k Před rokem

    Very nice! But tell me something:when alarm starts when is nobody home,who"s gona stop the siren????? Try the scenario with pulse,not bistable

    • @PoseidwnTech
      @PoseidwnTech  Před rokem

      Ajax Alarm has cloud access through Ajax App, so you can disarm the alarm and mute the siren through the Ajax App!

  • @MDsistemi
    @MDsistemi Před měsícem

    Non ci posso credere... con questo collegamento la sirena suonerà al mancare della rete alla quale è collegato l'alimentatore. Inoltre, con 12V stabilizzati la batteria della sirena non riuscirà mai a caricarsi correttamente. Ma non è tutto, il tamper apertura e rimozione della sirena esterna non lo vogliamo collegare? Lasciate fare a chi ne capisce...

  • @GUNITITSecurity
    @GUNITITSecurity Před 3 lety +1

    Strange I tried it with Pyronix bell did not work

    • @PoseidwnTech
      @PoseidwnTech  Před 3 lety

      I am not familiar with this Siren. Can you please send a link for the manual of the Siren to take a look?

    • @GUNITITSecurity
      @GUNITITSecurity Před 3 lety +1

      @@PoseidwnTech i think i have done it i did same as you but used the enginner hold and disable the tamper

    • @uruwashii5231
      @uruwashii5231 Před 2 lety

      @@GUNITITSecurity hello, would you be able to share the wiring for the Pyronix Bell setup please? I’ve just got two and wondering best way to wire in.

  • @Gnafo
    @Gnafo Před 3 lety +1

    connected my siren to the relay there is a low voltage error in the app, can you help me?

    • @PoseidwnTech
      @PoseidwnTech  Před 3 lety

      What Power Supply did you use? Relay requires 7 to 24 Volts DC. Normally an Alarm Siren requires 12 Volts DC but you have to check your Sirens specs about the maximum load current in order to select the correct Power Supply. I believe in most of the cases a 12Volts DC - 5 Amp should be enough.

  • @user-sm2lx9tw2h
    @user-sm2lx9tw2h Před 10 měsíci

    I thought the outside siren is the circle one..