- 500x300 RC Columns Reinforcement Detail (Rebar Arrangement)
Is video mein bataya Gaya hai k kis tarha se 500x300 size k column mein 8 bar proved Kiye jate hai, aur un k links ko Alag alag tarha se kis tarha banda jata hai....column k bar ko bandne k liye....links ya ties ki madat se bandha jata hai. links ya ties k bar ka minimum size 8mm hota hai....