Building In Ghana | Fault Finding | RCD Tripping Off During Heavy Rain

Sdílet
Vložit
  • čas přidán 8. 05. 2023
  • in this video, I have a client who called me to complain about a fault he has in his home and the fault is whenever there's a heavy downpour then there's a power cut at his downstairs whiles there's stable power at the upstairs. physical checks done, from main supply cables to the energy meter, to onload Changeover Switch and finally to the consumer unit or distribution board. there are many electrical outlets outside that might be responsible for the fault, so we will go back when next it rains and we will sort it out. #electric #solutions #ghana
  • Věda a technologie

Komentáře • 11

  • @ghcelebs-tv
    @ghcelebs-tv Před rokem +3

    I think he used the flexible wire for the phase indicators.

    • @multiskilledelectrician1
      @multiskilledelectrician1  Před rokem

      You absolutely right. I figured it out when I tracing the various cables. Thank you so much.

  • @ghcelebs-tv
    @ghcelebs-tv Před rokem +3

    I think there is 1 neutral or live wire getting contact with the exposed metallic part of either the DB or the Change-Over. The dressing in the DB and the change over is very poor.

    • @multiskilledelectrician1
      @multiskilledelectrician1  Před rokem +1

      That will cause an electrical issue called short circuit and short circuit wouldn't be able to trip an RCD but MCB. Thank you so much for the observation and input. I really appreciate you.

    • @benjamin1234777
      @benjamin1234777 Před 7 měsíci

      yeah the wiring is very bad,some Ghanaian artisan menn

  • @ibrahimmohammed-hn4gm
    @ibrahimmohammed-hn4gm Před 8 měsíci +1

    Check very well , maybe water enter some sockets or switches

  • @user-fy6qb2zc7v
    @user-fy6qb2zc7v Před 6 měsíci

    Yes whiles it normally happens when raining it can happen water enters somewhere in the electrical garget

  • @yussifabdulrafiw6936
    @yussifabdulrafiw6936 Před 3 dny +1

    Sometimes the RCD also tripped when there is water in the outside light

  • @user-fy6qb2zc7v
    @user-fy6qb2zc7v Před 6 měsíci

    Please help me where would you connect the neutral in the changeover switch whiles you single phase meter?