Building In Ghana, Three Phase Onload Change Over Switch Connection Explanation.

Sdílet
Vložit
  • čas přidán 29. 09. 2022
  • Onload Change Over Switch enable the smooth Switch of power from various sources. enjoy your electricity along side with generator, solar, ups and other power sources.
  • Věda a technologie

Komentáře • 55

  • @smookydepriest
    @smookydepriest Před 3 měsíci +1

    It's a good thing to share. It will help alot of upcoming

  • @catherinenwankwotv7079
    @catherinenwankwotv7079 Před rokem +3

    Nice , sharing

  • @electricsolutionsghana908

    Great job.

  • @ChristodiaObeng-ow3mt
    @ChristodiaObeng-ow3mt Před rokem +1

    Thanks for your advice

  • @mathewdong1426
    @mathewdong1426 Před rokem +1

    Good work u have putting there

  • @PrinceKutene
    @PrinceKutene Před rokem +1

    Handsome steps explanation.
    Thank you Director. I love the job

  • @Gigo
    @Gigo Před rokem +1

    Great Job Bro🔥 I see you 🖤🇬🇭✊🏾

  • @user-uo7uh3nj1w
    @user-uo7uh3nj1w Před 7 měsíci +1

    thanks ❤❤❤

  • @abibsalifou2505
    @abibsalifou2505 Před 23 dny

    So good evening Tuesday I want this one please can you show me how I feel fixed the power ratings how I see your video

  • @richardkofiessien3280
    @richardkofiessien3280 Před 7 měsíci +1

    Clear explanation but please can you explain to me how to connect the 3phase generator to the changeover

    • @multiskilledelectrician1
      @multiskilledelectrician1  Před 17 dny

      the onload changeover is three phase so you connect the wires from phase one ,phase two, phase three and neautral at the botton connection points.

  • @emmanueldarko4097
    @emmanueldarko4097 Před rokem +1

    Great job, but he for range the cable well in the main switch 🙏🙏

  • @abdulaibendu7257
    @abdulaibendu7257 Před rokem +1

    Great job,am also an electrician and I want you to do more video about installing changeover switch

  • @agbodjaloudenis
    @agbodjaloudenis Před 11 měsíci +1

    courage master

  • @AbdulkarimKamara-ow4cf
    @AbdulkarimKamara-ow4cf Před 11 měsíci

    How to run a strapper method in electrical

  • @user-px4xy7ty7h
    @user-px4xy7ty7h Před rokem +1

    I’ll like to join for more electrical skills

  • @anokyeemmanuel3371
    @anokyeemmanuel3371 Před rokem +1

    Please according to how your connection is the ECG is at the TOP and the generator at the DOWN
    But when the changeover is closed the indication on it please I think is missed please I'm a little bit confused please

    • @multiskilledelectrician1
      @multiskilledelectrician1  Před rokem

      You're not alone, so many electricians are confused about it too. But it's so simple. Yes according to my connection ECG is at the top and Generator at the bottom. The power source, either ECG or Generator could be at the top or bottom and the load (to consumer unit) is distinguished.

  • @kunuyanwilfred9328
    @kunuyanwilfred9328 Před 3 měsíci +1

    when the phases are looped will the changeover switch still work

    • @multiskilledelectrician1
      @multiskilledelectrician1  Před 3 měsíci

      Yes it will, you loop the phases when the standby power source is single phase, if it's three phase there will be no need to loop the phases.

  • @jojoaryee
    @jojoaryee Před rokem +1

    Please How much is the charge if you replace an old one, with a three phase ?

  • @iconicbrowser
    @iconicbrowser Před rokem +1

    Good work master but I need help of 110 and 220 wiring... Thanks

    • @multiskilledelectrician1
      @multiskilledelectrician1  Před 11 měsíci

      Okay. For the 230v and 110V wiring. The wiring is done normally, don't mix up anything of the 230v or the 110V (being it a neutral or earth) and finally you will need to install a 220V 110V step up and down Transformer to step down the 230v to 110V.

    • @TheBayasi
      @TheBayasi Před 8 měsíci +1

      @@multiskilledelectrician1 I, have an issue here you know transformer only converts voltage but not frequency so how do you convert frequency from 50hz to 60hz my house was wired both 220/110v and all the lights in the house were110v meaning 60hz frequency perhaps they are not going to function how they because the voltage frequency in Ghana is 50hz while US is 60hz . Do you have any ideas to convert 50hz to 60hz?

    • @multiskilledelectrician1
      @multiskilledelectrician1  Před 8 měsíci

      @@TheBayasi that's true. I noticed this some months ago, the step down Transformer we purchased for a project converts the voltage without converting the frequency, however all the 120V 60Hz appliances function fine.

    • @multiskilledelectrician1
      @multiskilledelectrician1  Před 8 měsíci

      @@TheBayasi also according to further findings, the missing required frequency here might only affect the appliances on long term basis.

    • @TheBayasi
      @TheBayasi Před 8 měsíci +1

      @@multiskilledelectrician1ok. did you buy the transformer in Ghana? I did a little bit research and about all the majority of the people are saying I need to buy PSU frequency converter from 230v 50hz to 110v 60hz and is not that cheap at all. I don’t know if it’s available in Ghana! if not then I have to get it from china.

  • @amewudastephen3085
    @amewudastephen3085 Před 3 měsíci +2

    Is the connection the same as bristol 3 phase change over

  • @natureessuman7817
    @natureessuman7817 Před 8 měsíci +1

    Please I need work I’m electrician from Ghana

  • @hagan_andrews2
    @hagan_andrews2 Před rokem +1

    Can we work together

  • @niiwelbeck8170
    @niiwelbeck8170 Před rokem +2

    Cable dressing is poor