Kukirin G2 Pro & G2 Max parameter setting introduction

Sdílet
Vložit
  • čas přidán 22. 12. 2023
  • Kukirin G2 Pro & G2 Max electric scooter parameter setting introduction about P01-P08-PA-PC.
    P01: km/mile selection setting, default km (0 is km, 1 is miles)
    P02: Voltage level setting: 36V/48V/52/60V/72V
    P03: wheel diameter: unit, inch; can be set to 080-160 (080 means 8 inches, 100 means 10 inches, and so on), increase by 5 each time;
    P04: Number of magnetic poles for speed measurement: range: 1-100, default 30
    P05: Cruise selection: 0 means no cruise, 1 means cruise. When the cruise is not turned on, the cruise icon is off; after the cruise is turned on, the cruise icon flashes; after the 8S enters the cruise, the cruise icon flashes; the default is not to cruise
    P06: Zero start, non-zero start setting, 0: zero start; 1: non-zero start, display the start mode when starting up (zero start will not display the icon, non-zero start will display NON)
    P07: Speed ​​limit setting: range 0-100 percent speed limit, default is no speed limit
    P08: Sleep time setting: 0, no sleep; other numbers are sleep time, range: 1-60; unit minutes, default 5 minutes
    PA: Starting strength setting: 1-5, 1 minimum, 5 maximum
    PB: brake force setting: 1-5, 1--20%, 2-35%, 3-50%, 4-70%, 5-100%
    PC: ODO clearing setting (0 means no clearing, 1 means clearing, after adjusting to 1, it will automatically exit clearing, and then PC will automatically return to 0 again)
    #electricscooter #kukirin #escooter #kukiring2max #kukiring2pro #enjoylife #foryou #foryourpage #offroad #riding #outdoors #fastscooters #scooter #parameter #aftersales #kugookirin #europe #release #tutorial #fyp

Komentáře • 1

  • @pierredeveloppement8844

    Perhaps you could specify PC: ODO clearing parameter? Is it reset settings?
    P08, is this the display time?