Single phase Motor Proper Wiring Connection MPCB |

Sdílet
Vložit
  • čas přidán 15. 10. 2022
  • Single phase Motor Proper Wiring Connection Diagram with MPCB | #electric #motor #shorts
  • Věda a technologie

Komentáře • 53

  • @pasinduhasaranga3988
    @pasinduhasaranga3988 Před 11 měsíci +10

    What is the different between MPCB and a contactor? becouse Both are used to protect the motor...

    • @hemantverma5625
      @hemantverma5625 Před 11 měsíci +3

      Contector ak electromegnet switch hai jisse hum kisi circiut ko on off karte hai jabki mpcb over load protection device hai jiska hum triping current ko adjust kar sakte hai

  • @sktechworks
    @sktechworks Před rokem +13

    இதன் பெயர் MPCB.Motor Protection Circuit Breaker.இது சரியாக வேலை செய்ய மூன்று முனைகளிலும் இணைப்பு கொடுக்க வேண்டும்.

  • @ratulelectricalbd114
    @ratulelectricalbd114 Před 4 měsíci +1

    ❤❤❤

  • @ciceromarquesalves1702
    @ciceromarquesalves1702 Před 11 měsíci +1

    Ola gostei muito . E possível ver fazendo essa ligação nesse motor sendo trifásico 😊

  • @ngaink
    @ngaink Před 27 dny

    Pemerataan beban / beban terbagi

  • @ratnioraon6631
    @ratnioraon6631 Před rokem

    Wow ♥️♥️♥️

  • @oumagodfrey7888
    @oumagodfrey7888 Před 11 dny

    Woow

  • @user-vd2wl1tu3d
    @user-vd2wl1tu3d Před 11 měsíci

    스위치 3상에 2상만 들어옴 모터도 2상 들어옴.스워치 모터 연결
    11 22,11 33,22 33 해도 되죠
    모터 2상 220 v 이죠
    스위치 입출 21왜 연결.1번 영상 연결 하면 안돱까

  • @ashokgupta7139
    @ashokgupta7139 Před 3 měsíci

    Good

  • @electricsimplebd.
    @electricsimplebd. Před rokem +1

    👍

  • @dogwalker666
    @dogwalker666 Před rokem +3

    Correct this is the recommended connection for the Telemecanique GV2 motor protection device 👍🏻

  • @tetirian2190
    @tetirian2190 Před 8 měsíci

    Mantap

  • @KuyoliNambuFrancis-gy7vk
    @KuyoliNambuFrancis-gy7vk Před 11 měsíci

    Wow

  • @highspeedgaz
    @highspeedgaz Před rokem +2

    3 phase standard overload , wired for single phase motor .

    • @kuyabaisvlog3723
      @kuyabaisvlog3723 Před rokem

      Wats makes defference between 1st one?

    • @dogwalker666
      @dogwalker666 Před rokem

      Nope it's a GV2 motor protection device you need all three heaters or you will get false tripping.

  • @Skare_
    @Skare_ Před rokem +2

    Это что за чудо вы накрутили с подключением.. это автомат! Не диф ни УЗО.не подключайте так двигатель!

  • @ryanperocillo7803
    @ryanperocillo7803 Před rokem +3

    can u please explain me why? thanks

    • @jp-wd9qy
      @jp-wd9qy Před 11 měsíci +3

      It is beacause it’s a 3 pole contractor overload, if only using 2 poles it could trip at lower ranges. It’s to do with the root 3 calculation.

  • @AchampongKwadwo-qf1to
    @AchampongKwadwo-qf1to Před 2 měsíci

    Good work done, please what is mpcb

  • @muratgurcan3826
    @muratgurcan3826 Před rokem

    Genelde nötr kontaklı sistemlerde tercihimiz değildir kontaktaki değişken dirençler nötğrde dirençler büyük hasara neden olur bunun için bir fazı 3 güç kontağından dolaştırın

  • @r.srinivasan3455
    @r.srinivasan3455 Před měsícem

    Wrong Connection Phase supply only taken For Series Connection, Neutral separate link 1phase I/p, 3-2,4-5, 6 phase o/p

  • @user-di3ni4zz2b
    @user-di3ni4zz2b Před 26 dny

    루프결선법

  • @satyamsatyamamchim2428
    @satyamsatyamamchim2428 Před měsícem

    Wt type it model name please

  • @almahrus3834
    @almahrus3834 Před 10 měsíci

    Cara kerjanya

  • @satyamsatyamamchim2428
    @satyamsatyamamchim2428 Před měsícem

    Why it

  • @Ssd-fh5eu
    @Ssd-fh5eu Před rokem +1

    Liking qyo

  • @user-mu8nd7tf7u
    @user-mu8nd7tf7u Před měsícem

    Why this we use msg

  • @user-iv6nt2vm3i
    @user-iv6nt2vm3i Před 5 měsíci

    টিভি কত ভল

  • @user-tw2ir5zt3d
    @user-tw2ir5zt3d Před rokem +4

    Это типо на двух фазах работает или что?

  • @sergrusRUS
    @sergrusRUS Před 3 měsíci

    Смысл ставить это кольцо мне не понятен , не чего же не поменялось кроме того что теперь фаза и ноль стали рядом с друг другом .

  • @kevinhuang666
    @kevinhuang666 Před rokem

    ???

  • @yusufgursoy5874
    @yusufgursoy5874 Před 4 měsíci

    Yanlış bağlantı

  • @user-yw8un2jw5i
    @user-yw8un2jw5i Před rokem

    what???this mis?

  • @muhammadnoor8681
    @muhammadnoor8681 Před rokem +2

    Why ?? Its same thing

    • @dogwalker666
      @dogwalker666 Před rokem +1

      Need all 3 heaters energised or it can trip on phase loss.

    • @muhammadnoor8681
      @muhammadnoor8681 Před rokem +1

      @@dogwalker666 its doesn’t make sense. If resistance increases its take long time to trip . And it’s a single phase motor not a three phase motor..

    • @dogwalker666
      @dogwalker666 Před rokem +3

      @@muhammadnoor8681 the device is a three phase motor protection relay it monitors for phase imbalance, overheating in the motor and of course motor over load, If using on a single phase supply you need to loop back one of the phase wires, These are manufactured by telemecanique Group Schneider, I used to be a drives system engineer for them.

    • @muhammadnoor8681
      @muhammadnoor8681 Před rokem

      @@dogwalker666 simple way is use over load really…

  • @sonycat108
    @sonycat108 Před rokem

    Why?

  • @omeccengenharia
    @omeccengenharia Před rokem

    fizemos esse vídeo na prática

  • @user-gg7zv4lr4r
    @user-gg7zv4lr4r Před 11 dny

    ❤❤❤

  • @electricsimplebd.
    @electricsimplebd. Před rokem +1

    Good