HOW HIGH AND LOW PRESSURE SAFETY SWITCHES OF A HVAC/ AC SYSTEM WORKS

Sdílet
Vložit
  • čas přidán 9. 09. 2020
  • How high and low pressure safety works and wired in a HVAC system .. how to install them • HVAC HACKS REPLACING B... #d2dnyac #hvac
    My Affiliate hvac tools links
    Get tools here👇
    amzn.to/3zcA2An - 2 pcs = 8 pcs box speed wrench
    amzn.to/40sma0T - hvac service wrench
    amzn.to/42K1CT7 - tool bag pack
    amzn.to/3ZoKW0G - allen wrench
    amzn.to/40INoju - coil brush
    amzn.to/3FWlrwG - utility knife
    amzn.to/3ZlsMwz - channel lock pliers
    amzn.to/3TTo0p1 - pipe wrench
    amzn.to/3FXjdx9 - adjustable wrench
    amzn.to/40Buuem - tape measure
    amzn.to/42J1dQN - wire jumpers for controls
    amzn.to/42IZcnP - 1/8 inch flat screw driver
    amzn.to/3KepgA7 - 11 in 1 nut and screw d
    amzn.to/3nqQn1P - pocket Thermometer
    amzn.to/3wqTXcQ - Muli meter/ ohm meter/ electric tester
    amzn.to/3mQ69AA - Guages
    amzn.to/3ocT2ci - Wire striper
    amzn.to/3lPu3hU - copper pipe cutter
    amzn.to/3FTchAW - testo 557s

Komentáře • 159

  • @chrisgomez724
    @chrisgomez724 Před 2 lety +11

    This videos is very informative, I do residential so troubleshooting high and low switches would be awesome!!
    Keep up the good work my man!!

  • @BallzToYou7
    @BallzToYou7 Před 3 lety +1

    Thank you so much. You dont understand how perfect and a godsend your channel is right now!!!!!

  • @williamtorres810
    @williamtorres810 Před 3 lety +1

    That was an awesome explanation..I had and RTU that was having pressure switch problem and thanks to this awesome video I was able to pinpoint the issue..Thanks man 👍👍

  • @hechos1v8
    @hechos1v8 Před 2 lety +2

    Very professional video. I love the way you explained step-by-step, you make it easy to understand better. Thanks Will B

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      Thank you for stopping by

  • @josearturobarajas4913

    I loved the video, it was difficult to find information about this security module and this video is very complete. Greetings engineer 👍🏿

  • @DWAYNE2ism
    @DWAYNE2ism Před 3 lety

    Great video really simplified .

  • @yoshisatoshi3206
    @yoshisatoshi3206 Před 2 měsíci +1

    You'll have a million subscribers in no time. Keep it up !

  • @alfredhines505
    @alfredhines505 Před 3 lety +16

    At 55psi the circuit will closed and at 30 psi the circuit will open to protect the compressor, due to the low pressure.

    • @tebbink
      @tebbink Před 3 měsíci

      Untuk saklar tekanan tinggi berapa range tekanannya?

  • @andresbarragan8595
    @andresbarragan8595 Před 2 měsíci +1

    GOOD MORNING FROM CHICAGO THANK YOU SO MUCH

    • @D2DNYAC
      @D2DNYAC  Před 2 měsíci

      What’s up Chicago , are you guys busy yet?

  • @OthmanAlikhan
    @OthmanAlikhan Před 2 lety

    Thanks for the video =)

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      Thank you for stopping by

  • @bago49
    @bago49 Před 3 lety +1

    Good vid bro👍 but waving that highly conductive watch next to those high voltage contactors 😅 had me on edge

  • @bigbite9804
    @bigbite9804 Před 2 lety +1

    Instead of Removing wire if you switch off condenser fan high pressure going increase then safety switch work perfectly..in same way if you can close high pressure line value then you get low pressure in that way u can check in real time your low pressure switch work perfectly.. this is how we do ..
    This is my opinion only ..u are doing great work..

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      Thanks for stopping by, please check my other video on this subject!

  • @Gabriel-vz7ml
    @Gabriel-vz7ml Před 11 měsíci

    Thank you!

    • @D2DNYAC
      @D2DNYAC  Před 11 měsíci

      Thanks for stopping by

  • @mithunsha422
    @mithunsha422 Před 3 lety

    Good job bro thx

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      Thanks for stopping by

  • @samyz1660
    @samyz1660 Před rokem

    Can you please do a video on a sequence of operation for bigger units, like 10, 20 tons please. I'm a new tech trying to learn . I have subscribed to your channel hoping to gain knowledge. Great channel by the way. Thx to CZcams algorithm who suggested your video.

  • @chris198004
    @chris198004 Před rokem +1

    this could have been a 30 second video but very informative

    • @D2DNYAC
      @D2DNYAC  Před rokem

      Thanks for stopping by

  • @syedbasheer8210
    @syedbasheer8210 Před 3 lety

    Thanks..

  • @hvacknowledgechannel1621
    @hvacknowledgechannel1621 Před 3 lety +1

    Nic sharing knowledgeable we should never bypass anyone of them

  • @babaolowo35
    @babaolowo35 Před 2 lety

    Thanks 👍

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      Thank you for stopping by

  • @Tokenomics1
    @Tokenomics1 Před rokem +1

    thanks!

  • @krishnaajaayajayaprakas5475

    Thanks bro

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      Thanks for stopping by

  • @brunomelvin4233
    @brunomelvin4233 Před 2 lety

    Yes sir I need thorough expl

  • @jackbrennan754
    @jackbrennan754 Před 3 lety +2

    Good information my question is how do you replace a high or low pressure switch without losing your refrigerant charge came across this problem.

  • @kashifkerr9309
    @kashifkerr9309 Před 2 lety

    Can you please make a video on understanding pressures?

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      Sure thing stay tuned for that

  • @kerrynball2734
    @kerrynball2734 Před 10 měsíci

    All the control circuit is 240V in my AC unit. I'd certainly be taking more care with those connectors an that scenario as they're going to bite a compared to a 24V control circuit.

  • @ricardoanguloavila41
    @ricardoanguloavila41 Před 10 měsíci

    Hi there!
    I have a problem with my Package Unit, the Diagnostic Codes for Defrost control Leds is telling me "HIGH PRESSURE SWITCH LOCKOUT" ...

    • @D2DNYAC
      @D2DNYAC  Před 10 měsíci

      Are you a hvac technician?

  • @itsmeagain6168
    @itsmeagain6168 Před 3 lety

    Big up

  • @Yourengineeringstandpt
    @Yourengineeringstandpt Před 10 měsíci

    Can you tie the hi pressure switch if not one avaliable in a tight spot, sort of like emergency situations

  • @ekpenyongakpan149
    @ekpenyongakpan149 Před měsícem

    I want to know how a low and high pressure switch is been connected. Thanks

    • @D2DNYAC
      @D2DNYAC  Před měsícem

      I have a video uploaded already check it out

  • @SharifKhan-yz2er
    @SharifKhan-yz2er Před 2 lety

    Thank you so much

  • @xraybravo7180
    @xraybravo7180 Před rokem

    Do you know how trane 2 stage packagw unit compressor lockout works ? Apparently I had low pressure got power going in and out however high pressure switch and discharge line snap disk switch didn't have power during compressor lock out.

    • @D2DNYAC
      @D2DNYAC  Před rokem

      Get me the model number and I can tell you

  • @juannanez3969
    @juannanez3969 Před rokem

    I just checked for continuity in both my switches. One of them showing there is continuity and the other one showing 400 ohms of resistance. What does that mean? I’m also not getting 24V at the side legs of the contractor, but I am getting the 24V coming from the thermostat.

    • @D2DNYAC
      @D2DNYAC  Před rokem

      Replace the switch with the 400 ohs of resistance I would start there!

  • @wdennis8
    @wdennis8 Před 3 lety

    The pressure switches are running through the coil right? It’s a 24v - 240v switch right? Please explain how you hooked up the wiring for the switch. How does it interrupt the contractor?

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      I will do another video upload this week on that look out for it

  • @brunomelvin4233
    @brunomelvin4233 Před 2 lety

    Sir please make vedio on career package Ac using two compressors and the wiring diagram for the lock out relay wiring . Please explain how it's wired and how it works.

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +1

      Hello friend Do you want to know how the lockout relay works and wired?

    • @brunomelvin4233
      @brunomelvin4233 Před 2 lety

      @@D2DNYAC yes sir I need a vedio thoroughly explaining how the lock out circuit works employing two compressors and two lockout relay for two circuits. I am asking you from Bahrain Another vedio on Big career split Ac indoor unit staring with DOL starter wiring diagram. Please I hope you help sir.

  • @AnthonyWilliams-go2tl
    @AnthonyWilliams-go2tl Před 3 lety

    Hello I'm having problems with a stand up hvac. I didn't open the door on the back for the fans for the condenser to blow out and it shut the unit down. The reading are at 100psi on the blue side of my gauge.Is there any way to get the presure back down so the hbac can come back on.

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      Not enough information here for me to advise you!

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      What manufacturer? What’s the issue or exact problem?

  • @user-tg6sg6ho4h
    @user-tg6sg6ho4h Před 2 lety

    Question: When does the high-pressure sensor disconnect the gas 22

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      350 to 410 psig depending on the switch

  • @odeliocepeda6054
    @odeliocepeda6054 Před 2 lety +1

    In the case of , you come across a bad low pressure switch and don’t have any low pressure switches on hand ,but the unit needs to go up. How do you jump out the switch ? until you go and get a switch

  • @yanheriherlambang8019
    @yanheriherlambang8019 Před 3 lety

    How to change oil scroll compresor in tandem sytem.? Thanks a lot.

    • @D2DNYAC
      @D2DNYAC  Před 3 lety +1

      The easiest way would be to use the oil ports or connecting oil equalizer lines to drain the oils and then refill it through the oil or suction service ports.

    • @yanheriherlambang8019
      @yanheriherlambang8019 Před 3 lety

      @@D2DNYAC Do you have the video..? I wanna see it.Thank you so much.

  • @theodoe5425
    @theodoe5425 Před 3 lety

    I wanna know more about the time delay.

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      Okay I will do a video on it or incorporate it into another video. Stay tuned for that

  • @patrickmekus1476
    @patrickmekus1476 Před 2 lety

    Pls i want to know how each of the switches were connected to the system

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      the switches are connected in series most of the time!

  • @roopramsoeknandan7601

    I have the same system in my building. So one of my compressor has water inside I had a technician came over telling me that we need to replace a compressor when they come with the new . They told me the heat exchanger has internal leak in there. I just want to know if that’s true

  • @zeke6150
    @zeke6150 Před rokem

    Hello sir! Can you make a video searching for leaks in the system? Like the problem is that the unit is not cooling although it's operating?
    Thank you very much!

    • @D2DNYAC
      @D2DNYAC  Před rokem

      Okay

    • @joechambers09
      @joechambers09 Před 5 měsíci

      ​@@D2DNYACi have a lennox xp13 system and my green light is blinking showing high pressure fault...my compressor is not coming on and the switch had automatic reset but dint think its resetting...what can i do to reset it

  • @patrickl3625
    @patrickl3625 Před 2 lety

    Please Please Please D2D NY … Can you Explain ( What is Restriction T.X.V valve) to Troubleshooting

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      The TXV creates a controlled pressure difference between the high and low side of your refrigeration system as refrigerant flows through it, when the TXV is restricted that pressure drop becomes uncontrollable thus starving your low side/evaporator of refrigerant Symptoms is low back pressures, most times high head pressure, high suction line temperatures/ super heat, high supply air temperature, poor cooling. Solution replace the valve

    • @patrickl3625
      @patrickl3625 Před 2 lety

      Can you please shown the video how to troubleshooting The TXV valve restriction

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      Okay stay tuned

  • @justinhinds4388
    @justinhinds4388 Před rokem

    I want to know what capacitor and transformer does?

    • @D2DNYAC
      @D2DNYAC  Před rokem

      Transformer lower the incoming line voltage to control voltage 460/208/120 volts to 24 volts, capacitor is used on single pashas motors/ compressors to increase starting and running power

  • @MangoEnchilada-
    @MangoEnchilada- Před rokem

    Will the condenser fan still run if the pressure swith trips?

    • @D2DNYAC
      @D2DNYAC  Před 11 měsíci

      In some cases yes especially carrier RTU units

    • @MangoEnchilada-
      @MangoEnchilada- Před 11 měsíci

      I have a lennox 13acx-036-230 13. The entire unit runs and turns on, but it blows hot. Im thinking low refrigerant?

  • @terranhealer
    @terranhealer Před 9 měsíci

    I have a code 35 error which means a low pressure switch or sensor error. My system doesn’t have a leak though. Is there a way to bypass this faulty switch or sensor?

  • @dbc105
    @dbc105 Před 4 měsíci

    What switches are you using andd where are you getting them?

    • @D2DNYAC
      @D2DNYAC  Před 4 měsíci

      The switch pressure cut in and cut out rating depends on the refrigerant

    • @D2DNYAC
      @D2DNYAC  Před 4 měsíci

      Refrigeration or hvac supply house or shops or on the internet

  • @tafsheeralam9833
    @tafsheeralam9833 Před 3 lety

    Sir i have some issue i instaled compresor nd i try to charge freon but compresor are trip by low pressor switch plss tell me some way to charge freon

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      What you should do is place the Freon tank in a bucket of hot water or use a heat gun/ blower to warm up the tank this will allow charging while compressor is off best practice.

  • @kellesaereanque2131
    @kellesaereanque2131 Před rokem

    Is it possible to replace the high pressure switch into one that can be adjustable

  • @ras2820
    @ras2820 Před 3 lety +1

    So high pressure switch is pressure is fine the switch remains closed once pressure gets to high switch opens??

    • @D2DNYAC
      @D2DNYAC  Před 3 lety +1

      👍 yes

    • @joechambers09
      @joechambers09 Před 5 měsíci

      ​@@D2DNYACis there a way to measure if the high pressure switch is open on a automatic switch

  • @sheeesh3355
    @sheeesh3355 Před 2 lety

    What should i do if there is no manual reset on pressure switch

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      Nothing this means the switch will automatically reset once the pressures come down

    • @joechambers09
      @joechambers09 Před 5 měsíci

      ​@D2DNYAC how do you get the pressure to come down

  • @La2venida
    @La2venida Před 3 lety

    Question: could I bypass the pressure switch, charge the system, and just leave it jump?

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      Sure, however that’s dangerous to anyone who operates this system and to the system it self, so please don’t

    • @La2venida
      @La2venida Před 3 lety

      @@D2DNYAC why would it be dangerous to one that operates...are there system s that don't have pressure switchs

    • @HelloThere-jr6gd
      @HelloThere-jr6gd Před 2 lety

      Because if your system does pull a high head pressure or a very low suction pressure the system wont shut off and it will ruin your compressor. Only bypass it if its temporary and you are coming back to fix it later. Dont leave it bypassed.

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +1

      It’s not dangerous to one that operates however if you bypass the high pressure switch you can definitely ruin your compressor bypassing the low pressure switch isn’t too bad however you can still ruin your compressor if the system freezes up and slug liquid refrigerant back to compressor. If you must only do it during troubleshooting or in an emergency if the switch or switches is faulty and system pressures are okay. And return and remedy ASAP.

  • @user-ge9on2zz4g
    @user-ge9on2zz4g Před rokem

    How do you know if the pressure sensor is broken or working?

    • @D2DNYAC
      @D2DNYAC  Před rokem

      They are typically normally closed switches, when system pressure is good, and opened if faulty or if system has a problem

    • @user-ge9on2zz4g
      @user-ge9on2zz4g Před rokem

      @@D2DNYAC Under normal circumstances, is there electricity at one corner or both corners?

  • @mohammadfahimnaimi4222

    Brother I need help, my ax unite has a bad high pressure switch how can I replace it and where I can buy it I really need a little help

    • @D2DNYAC
      @D2DNYAC  Před rokem

      Where are you located ?

    • @mohammadfahimnaimi4222
      @mohammadfahimnaimi4222 Před rokem

      @@D2DNYAC Arizona

    • @D2DNYAC
      @D2DNYAC  Před rokem

      Hvac supply store, don't know what's in Arizona!

    • @D2DNYAC
      @D2DNYAC  Před rokem

      You will need to know what refrigerant system uses and you can purchase a swivel tee as well and follow my method

  • @ras2820
    @ras2820 Před 3 lety

    Is the high pressure switch the same as the high pressure control

    • @D2DNYAC
      @D2DNYAC  Před 3 lety +1

      No!

    • @ras2820
      @ras2820 Před 3 lety +1

      @@D2DNYAC ok so if you don't mind me asking what is the high pressure control thank you?

    • @D2DNYAC
      @D2DNYAC  Před 3 lety +1

      😂 a device that controls the head pressure.
      There is various types I have a video on type of head pressure control device! I will link it below👇🏻👇🏻👇🏻video

    • @D2DNYAC
      @D2DNYAC  Před 3 lety +1

      HEAD PRESSURE CONTROL VALVE / HPCV/ HEAD MASTER HOW TO INSTALL & WHAT IS IT?

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      In my video title above is one type of head pressure control device. Examples of others are Variable frequency drives, fan cycling switches, motorized dampers, motorized valves

  • @Toylakwatsero
    @Toylakwatsero Před 2 lety

    What is the purpose of contactor sir?

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +1

      @ abet lakwatsero It is an electronic switch which is controlled by your thermostat , the thermostat passed low or controlled voltage usually 24V to the contactor coil then the switching section of contactor then pass high voltage to the load compressors and fan motors to put it simply, it can get more complex

    • @Toylakwatsero
      @Toylakwatsero Před 2 lety

      @@D2DNYAC Thank you for information sir God Bless

  • @tserevenad
    @tserevenad Před 2 lety

    My compressor won't run, won't make a noise. wondering about pressure switches. But, condenser fan does run, thus contactor working. If my logic is right, per your video, my pressure switches must be ok. worth noting I have a defrost board could that matter. thanks.

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +1

      @Tserevenad if you have a residential split system and the fan on top of the outdoor unit spins, and compressor doesn’t run it seems like your compressor is bad!

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +1

      In this case for 1PH units a hard start kit my help!

    • @tserevenad
      @tserevenad Před 2 lety

      @@D2DNYAC yes I have a stains you describe. I used my ohmmeter to check coil winding. Shorts to ground and a stuck overload switch. Everything perfect. Can compressor be bad if electrical tests are good. Doesn’t blow fuses either. Also cap and contractor measure/working properly. I am thinking something going on with defrost board and sensor but not clear on why it would make compressor not run. Thanks for your thoughts.

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +1

      Then if this is the case typically the fan and compressor shares the same contactor the compressor 1PH compressor is seized, try using a hard start kit /capacitor sometimes this will get compressor going, you can also send me a picture of your ac unit and wiring diagram on (what’s app) so I can better assist!

    • @tserevenad
      @tserevenad Před 2 lety

      @@D2DNYAC appreciate your help. I just reread my last text and it is nonsense so I need to give you correct info. I need to setup WhatsApp on my phone and reach out to you again this afternoon. Thanks.

  • @danielobethlopezdelgado5059
    @danielobethlopezdelgado5059 Před 11 měsíci

    Acapulco

  • @janjantagud9918
    @janjantagud9918 Před 3 lety +1

    How to by pass high pressure switch?

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      Don’t recommend this unless you are troubleshooting!

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      Don’t recommend unless troubleshooting , however you can bypass by cutting both wires connected to the switch, then strip and connect both wire going back into the controls together

    • @janjantagud9918
      @janjantagud9918 Před 3 lety

      But the pressure switch has three wires... 😭

    • @theodoe5425
      @theodoe5425 Před 3 lety

      I wanna know more about the time delay

  • @aripapari9226
    @aripapari9226 Před rokem

    Can I call you for service? I’m in queens NY

  • @lyotoarellano
    @lyotoarellano Před 2 lety

    Do you respond to questions?

  • @dwmcever
    @dwmcever Před 3 lety

    Worked in refineries and chemical plants most of my life, you're not allowed to wear watches or rings of any kind or Jewelry period . Doesn't matter your rank or craft. Those Blue Gloves and grabbing HOT WIRES are going to get this guy killed. Yes I am an expert, Senior V.P. Engineering (retired). Couldn't get past the safety issues here to watch the video for content. Had he been one of my employees he would have been suspended until he attended required safety classes.

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      Hey 👋 thanks for stopping by! 🤔l understand and knows all the risks involved with the job however things are different inside of a plant that’s a controlled environment out here in HVAC you are going to have to troubleshoot live circuits and I have yet to see anyone got suited up to do so., I am a pro and knows and understand what I am doing and I can assure you after 17 yrs in the industry I will not be killed by the HVAC trade craft🤫😂

  • @donttalktome9528
    @donttalktome9528 Před 3 měsíci

    Jamaican.

  • @PBS-nm1uu
    @PBS-nm1uu Před rokem +1

    bad camera angle

    • @D2DNYAC
      @D2DNYAC  Před rokem

      What didn't you not see ?

  • @SateeshMaurya-xv4dm
    @SateeshMaurya-xv4dm Před 9 měsíci

    Sir please language in Hindi use

    • @D2DNYAC
      @D2DNYAC  Před 8 měsíci

      Thanks for watching

  • @jessuezhernandez1991
    @jessuezhernandez1991 Před rokem

    My A/C works but the won't switch over to blow out heat? What could be the issue? We had someone come change out our pressure switch and The heater went out... any tips or advice you can give me ? I'd appreciate it

    • @D2DNYAC
      @D2DNYAC  Před rokem +1

      In the case of a heat pump it’s either the thermostat configuration/wiring or a bad reversing valve in the case of other heating systems type pressure switch on AC would have no impact on heating

  • @danielobethlopezdelgado5059
    @danielobethlopezdelgado5059 Před 11 měsíci

    Acapulco