How To Install a 30 amp Dryer Circuit With Breaker and Outlet

Sdílet
Vložit
  • čas přidán 27. 08. 2024

Komentáře • 122

  • @davidparker2173
    @davidparker2173 Před rokem +25

    You make me feel like an apprentice on the job with a friendly pro who is not dedicated to ruining my day. You also detail fairly well. I would rather hear things again and again than for some guy to assume I already know this, and this, and that. I just hit the like, and subscribe. Thanks

  • @botsman35
    @botsman35 Před 9 dny

    Absolutely love your ability to turn any project into exiting show!

  • @RBG-tr9ce
    @RBG-tr9ce Před 5 měsíci +2

    I'm doing this exact job tomorrow AFTER I fish the wire down the walls. I had done this 50 years ago so this was a good refresher. "See one, do one , teach one".

  • @davesillik
    @davesillik Před 7 měsíci +1

    Thank you. Haven't ever done 220 but it all worked out beautifully and safe.

    • @Askmediy
      @Askmediy  Před 7 měsíci

      Awesome glad to hear it

  • @CasualRican
    @CasualRican Před rokem +3

    Thanks again for this video, I installed my dryer outlet by following your instructions. 👍

    • @Askmediy
      @Askmediy  Před rokem +1

      Hope it works lol. Good deal

  • @jacknelson4212
    @jacknelson4212 Před rokem +2

    Great video. Only one I could find that hooked up the 4 wires and breaker in the breaker box. Also good explanation for the reason from going from 3 to 4 wire recepticle.

    • @jesserentas7425
      @jesserentas7425 Před rokem

      Bro you ain't kidding I'm looking at these other videos thinking where in the world do the other 2 wires go christ!😂

  • @FrankBocker
    @FrankBocker Před rokem +1

    I really like all the little side details and prerequisite information peppered in this tutorial. There's a lot of higher-budget stuff around that's not nearly as informative.

    • @Askmediy
      @Askmediy  Před rokem +1

      Thanks Frank. It’s what I try to show

  • @insanechevy91
    @insanechevy91 Před rokem +2

    Guy reminds me of a old guy I worked with last summer wired aleast 4 boxes with him more then I can remember service calls for light fixtures and ceiling fans and outlet replacements lol cool guy 😂

  • @davidgasperlin6807
    @davidgasperlin6807 Před rokem +3

    Great video im putting in a new line to my dryer so this really helps

  • @MarineMT-0312
    @MarineMT-0312 Před 3 měsíci

    Brother from the northeast best friggen video hands down no elaborate BS straight to the point, you are the man!!!

    • @Askmediy
      @Askmediy  Před 3 měsíci

      Thanks buddy, yeah who has time for BS

  • @VicToR_Rider
    @VicToR_Rider Před 2 měsíci

    Lol u nailed it with hearing a pop and the wife yelling fire😅 I messed up changing dryer plug. Mixed the black and white.

  • @malindabrowning9240
    @malindabrowning9240 Před rokem +1

    I think you’re hilarious. I recently wired up my breaker and the outlet for a dryer, and I definitely was a little nervous about turning on the breaker. You made me laugh so hard when you were teasing us about it.

    • @Askmediy
      @Askmediy  Před rokem

      LOL But very true LOL.

    • @blizte3
      @blizte3 Před 11 měsíci

      @@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @happycamper137
    @happycamper137 Před rokem

    Thank you for this video, I agree with all the comments. It really helped me, every electrician I talk to say they'll do it and don't. I learned what the wires are for and the positions. Which now gives me knowledge and confidence. Again, thank you.

  • @germangomez7097
    @germangomez7097 Před rokem +5

    Perfect explanation. Just what I was looking for. Thank you

    • @Askmediy
      @Askmediy  Před rokem +1

      Awesome, glad I could help you out.

    • @blizte3
      @blizte3 Před 11 měsíci

      @@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @juanftuchezsandoval2031

    Thanks for the video you explain it perfectly exactly the way I want to hear thanks again

    • @Askmediy
      @Askmediy  Před 14 dny

      Awesome, glad you liked it.

  • @AngelerFils
    @AngelerFils Před rokem +2

    00:43 The counting made me burst out laughing 🤣🤣

  • @DelmaRaySmithJr
    @DelmaRaySmithJr Před rokem

    Funny way of sharing what you know, in a humorous manner, thx

  • @briankeithhamilton4216
    @briankeithhamilton4216 Před 9 měsíci

    Loved the Ending! Thank you🤗

  • @IamMattW.
    @IamMattW. Před 11 měsíci

    Perfect! Exactly what I’ve been looking for. Nobody explains the panel part. And you made this video very entertaining! Hopefully my wife doesn’t yell at me though 🤣

    • @Askmediy
      @Askmediy  Před 11 měsíci +1

      Good deal. Thank you so much

    • @blizte3
      @blizte3 Před 11 měsíci

      @@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @youngjimmystro8176
    @youngjimmystro8176 Před 4 měsíci +1

    Lmao I love the ending man thanks for this video. Very helpful. I think I mis connected my outlet thanks for this!

    • @Askmediy
      @Askmediy  Před 4 měsíci

      Thanks buddy, glad you liked it.

  • @robmorse5239
    @robmorse5239 Před rokem

    Thanks... I really like you teaching style

  • @ricodinero4926
    @ricodinero4926 Před 8 měsíci

    come on askmediy , you make it look easy.

    • @Askmediy
      @Askmediy  Před 8 měsíci

      Because it is. You can do it

  • @alsemi-back-up579
    @alsemi-back-up579 Před rokem

    Great Video & Explanation of Wiring The RightWay!
    Thanks ForThe Upload
    Keep up The Great Work That You Do
    From Canada.

  • @Slavic_Eagle
    @Slavic_Eagle Před rokem +1

    Glad your uploading again!!! 💪🇮🇹

  • @hamsbyyams
    @hamsbyyams Před 6 měsíci

    “Let’s just say this is being inspected. WhiCh iT’s sUppOSed tO Be 🤪.” Had me cracking up lol

  • @skippy493
    @skippy493 Před rokem +2

    Hey man when are you going to post some new videos I really like your videos

  • @paulholloway5458
    @paulholloway5458 Před rokem

    Brilliant Work, Thanks.Just needed a fresh reminder.

  • @mikebartoli4755
    @mikebartoli4755 Před rokem

    That was just like standing next to my uncle while he's teaching me something! Well done sir, thank you making this tutorial.

    • @Askmediy
      @Askmediy  Před rokem

      Very nice to hear. Thank you very much

    • @blizte3
      @blizte3 Před 11 měsíci

      Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @alangloria939
    @alangloria939 Před 6 měsíci

    I was convinced until the end 😅 adrenaline just shocked my body

  • @joshcapecod6098
    @joshcapecod6098 Před rokem

    Good video. Except the breaker is required to be GFCI...since 2020. And best to check the dryer cord hookup as well....kind of big things.

  • @juancruz4179
    @juancruz4179 Před 25 dny

    Thanks for this good video.

  • @jsville2023
    @jsville2023 Před rokem +1

    This guy is great. Subscribed.

  • @Douglaskyle9191
    @Douglaskyle9191 Před 9 měsíci +1

    If my wire to the black dryer outlet box is damaged by a dog I feel like I could cut it shorter and move the outlet higher instead of running all wire for my outlet. I have exposed silver wires that wrap around the core that are severed but dryer still works.

    • @Askmediy
      @Askmediy  Před 9 měsíci

      Seems like it would be better to just replace the dryer cord.

    • @Douglaskyle9191
      @Douglaskyle9191 Před 9 měsíci

      The outlet it plugs into is damage but not the actual cord to the dryer. A dog ripped open the sheet rock and began to tear open the wire leading to the outlet. I found this when getting my house ready to sell. The old owners left me this surprise and I have been living with it for 6 years lol Also the outlet is against the floor which I think I saw is not code anyways. 1987 home

    • @Askmediy
      @Askmediy  Před 9 měsíci

      @@Douglaskyle9191 There is no code on the height of the outlet. If the wire is coming above it, you should be able to just raise it up to good wire.

  • @SAWA-nx5co
    @SAWA-nx5co Před rokem

    I spent few hours to find this. Thanks. You explain all from A to Z)))

  • @user-ym3nk2ww4c
    @user-ym3nk2ww4c Před 10 měsíci

    Excellent explanation... should I use 10/3 romex to the panel from a 30 amp inlet plug for a generator (7500 running watts)? Or can I use 10/2 romex?

  • @mattkelley7890
    @mattkelley7890 Před 10 měsíci

    Never showed a close up inside the box. THE MOST IMPORTANT PART

  • @majinkakashi20
    @majinkakashi20 Před měsícem

    Awesome video, thanks man

  • @bryanlipscomb8918
    @bryanlipscomb8918 Před rokem +1

    You funny dude. Great tutorial

  • @melquemcleash6607
    @melquemcleash6607 Před 10 měsíci

    This guy is a good teacher!

  • @whoisradu
    @whoisradu Před rokem

    You make me feel like I can actually do this, even though I am extremely terrified, L O L

  • @marchaney
    @marchaney Před 5 měsíci

    Thank you!

  • @lionelbutnotrichie7703
    @lionelbutnotrichie7703 Před 4 měsíci

    Is there code for how far or close an outlet can be to the circuit box. I have to move my dryer to the opposite wall and the opposite wall contains the breaker box

    • @Askmediy
      @Askmediy  Před 4 měsíci

      No not at all. Distance, yes. But nothing you need to worry about.

  • @nickdiamond7595
    @nickdiamond7595 Před rokem +1

    0:45 He's giving us the neutral finger

  • @josefcalderonromero8452

    Beautiful 🤩 exactly what I was looking for . Question. I want to install about 5-8 240 baseboard heaters in my basement. You think 2 30 amp circuits would be enough?

    • @Askmediy
      @Askmediy  Před rokem

      Most baseboard heaters are 20 amp. Please follow the instructions for sure.

  • @fuqui035
    @fuqui035 Před 5 měsíci

    The plate cover had Togo first behind the plug

  • @user-je3jo1kn8x
    @user-je3jo1kn8x Před 8 měsíci

    Excellent video

  • @Ojeramup12
    @Ojeramup12 Před 5 měsíci

    Can the green ground wire be connected to the white ground port? On 10;00 the wire is not connected.

    • @surferdude642
      @surferdude642 Před měsícem

      No. Only to the green ground screw and never connect a ground wire to a neutral intended location. The neutral and ground are bonded at first disconnect means (usually the main panel) and nowhere else.

  • @Shadi2
    @Shadi2 Před rokem +1

    By any chance, is your brother a botanist?

  • @theadventuresofchris1409

    thank you for making this video

  • @LetsGo6009
    @LetsGo6009 Před 7 měsíci

    Thanks!

  • @sickntired2059
    @sickntired2059 Před 15 dny

    You're good.

  • @djreag8614
    @djreag8614 Před rokem

    HEY DOMINIC ,YOU DA MAN ,COME UP TO NOVA SCOTIA AND DO SOME ELECTRICAL ,,

  • @lionwolf5768
    @lionwolf5768 Před 10 měsíci

    Great video thank you!

  • @troyandeviegray9736
    @troyandeviegray9736 Před rokem

    It looks like the wiring on the hot water tank are 12 ga is 10ga okay for the run of about 10 ft and 10ga 3 wire outfit a dryer that’s even closer to the power panel, also I have a Meg welder the plug has a ground and a small and large knife blade the the outlet shows 120/240 at 50amp, how big should the wire be and what size breaker do I need

  • @oliverlu3259
    @oliverlu3259 Před rokem

    make it very clear to me. good job. thank you1

    • @Askmediy
      @Askmediy  Před rokem

      Awesome. thank you so much.

  • @whoisradu
    @whoisradu Před rokem

    Hey guys what if the new 30A breaker doesn’t fit in the old box? Do you just get two 30 breaker that are the same type as the old breakers and run the two hots to each? Thanks for any advice

  • @jasonmacdonald27
    @jasonmacdonald27 Před rokem

    GREAT VIDEO

  • @jenniferowen-ep2gp
    @jenniferowen-ep2gp Před rokem +1

    Tbis is a dumb question, but, you said 30 Amp breaker. And it's a double breaker... does that mean 15 and 15? Or 30 and 30

    • @Askmediy
      @Askmediy  Před rokem +1

      Not dumb at all. This means the total protected circuit is 30 amp

  • @geyser3445
    @geyser3445 Před rokem

    I have a 220 volt electric hot water heater in my basement and want to add a switch at the top of my basement steps to turn it on and off. Can you show us how to do that and what switch to use? Thanks.

    • @Askmediy
      @Askmediy  Před rokem

      Just like any other switch. But it's a two-pole switch. Meaning that each side of the switch is for each hot. With 240 volts it's essential to switch both hots.

  • @bobbydbuilder2873
    @bobbydbuilder2873 Před rokem

    I have old air compressor with a 10.20 nema. The only outlet I could find does not have a ground screw. Just 2 gold hot and silver neutral. I need some advice or a quick how to. Does it need to have a ground or just wire as is?

    • @Askmediy
      @Askmediy  Před rokem

      Are you sure it's 220 volt?

  • @be4fourty
    @be4fourty Před rokem

    Thanks for the video

  • @stevenramsar456
    @stevenramsar456 Před rokem

    Very helpful thanks😂😊

  • @christianahava
    @christianahava Před 11 měsíci

    Top notch info

  • @tomassoyweyvon4902
    @tomassoyweyvon4902 Před rokem

    Hey, Piasan...you mentioned Old vs New dryers with electronics, the question now is, the home dryers are wired with two wire 10, i had a new washer dryer installed with electronics, should i convert the two wire to three 10 ???? access is no problem

    • @Askmediy
      @Askmediy  Před rokem

      Funny you say “piasan” I’m in Italy right now lol. Yes, you should if you can. Because you’ll need the two hots and the neutral. Ground of course

    • @tomassoyweyvon4902
      @tomassoyweyvon4902 Před rokem

      @@Askmediy Hey, grazie per la reposta..I will do that...Godere!!!

    • @tomassoyweyvon4902
      @tomassoyweyvon4902 Před rokem

      in addition i found out 1996 was the cutoff for three prong vs 4 per N.E.C., again Thanks

  • @hwl6969
    @hwl6969 Před rokem

    Does it matter if you use a blue plastic box or a metal one?

    • @DominickAmorosso
      @DominickAmorosso Před rokem

      No, not at all but if you use a metal box, you will have to ground it

  • @djreag8614
    @djreag8614 Před rokem

    Hey Dom, can I put neutral and ground wire on the same side in the panel box?

    • @DominickAmorosso
      @DominickAmorosso Před rokem +1

      Sure, as long as it’s not a sub-panel

    • @djreag8614
      @djreag8614 Před rokem

      @@DominickAmorosso THANKS DOM, TOO EXPENSIVE TO HIRE ELECT. SENIOR YA KNOW ,,, NOW ONE MORE QUESTION THE COPPER GROUND THATS BARE ,CAN I JUST ATTACH IT TO THE SCREW AT THE BACK OF THE BOX THEN CONNECT IT TO THE GROUND PLUG OPENNING ?.. PLUS THERE ARE STILL LIVE WIRES EVEN THOUGH THE PANEL IS SHUT OFF RIGHT?

  • @ReyesCTR0025
    @ReyesCTR0025 Před rokem

    Nice video!!!

  • @blizte3
    @blizte3 Před 11 měsíci

    Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

    • @DominickAmorosso
      @DominickAmorosso Před 11 měsíci

      That’s a big question, what did you test?

    • @blizte3
      @blizte3 Před 11 měsíci

      power on but dryer will not heat up@@DominickAmorosso

    • @blizte3
      @blizte3 Před 11 měsíci

      also it has power spin tumbler without heat
      of any kind, on any heat setting, no sparks nor signs electric discharging beyond normal@@DominickAmorosso

  • @marineguy4eva
    @marineguy4eva Před rokem +1

    That neutral wire doesn't give a.....!

  • @Hayden-sp1ol
    @Hayden-sp1ol Před 9 měsíci

    Extra grond wire via pig tail...? ?? I lost

    • @Askmediy
      @Askmediy  Před 9 měsíci

      Ground outlet to metal box via the ground wire coming in

  • @woodstream6137
    @woodstream6137 Před 3 měsíci

    Probably calling an electrician. I need to run a ground to old 3 prong dryer outlet, thankfully its like a foot away from the breaker. My 30yr old speed queen finally finally died and I'm loathing having to buy a new budget machine.

  • @seanrobbins1916
    @seanrobbins1916 Před rokem

    I would apprentice with you

  • @kavya1638
    @kavya1638 Před 3 měsíci

    gonna leak something here... your dryer doesn't need to be using 30 amps, in fact, just a few pico amps. the reason it draws so much is because it was designed this way (on purpose), ie, the electric company needs to make money somehow. all your electronics, really, are designed to operate in the high amp range. 15amp vacuum cleaner, blender motor, etc.. turns out, a little project that draws energy out of the air feeds a heating element in the "pico amp range" and gets just as hot as your dryer's heating element. thanks to a few advancements in this field, the electric company is guaranteed to go out of business. give it a few years..

  • @susancasavant5227
    @susancasavant5227 Před 8 měsíci

    what a goober

  • @TonyyFlow
    @TonyyFlow Před rokem +1

    FIRST!

  • @davidcase4600
    @davidcase4600 Před 3 měsíci +1

    Unsat, unsafe. If you use a metal box, ground it

  • @valery9958
    @valery9958 Před rokem

    ρяσмσѕм