HVAC TROUBLESHOOTING

Sdílet
Vložit
  • čas přidán 16. 08. 2024
  • hvac troubleshooting, hvac troubleshooting guide, hvac training on this commercial hvac / air conditioning unit no ac service call step by step and in depth with resolution.
    see how to troubleshooting an air-conditioning system in the commercial world of hvac
    #d2dnyac #hvactroubleshooting #hvactraining #commercialhvac

Komentáře • 80

  • @user-mm1cl7ez2h
    @user-mm1cl7ez2h Před 2 měsíci +1

    Thanks for your great instructions clear and concise

    • @D2DNYAC
      @D2DNYAC  Před 2 měsíci

      Thank you for stopping by

  • @jarvisagulto9222
    @jarvisagulto9222 Před rokem +6

    Really like you walking through schematic. Really hard to learn sometimes. Keep them videos coming. Much appreciated.

  • @yoshisatoshi3206
    @yoshisatoshi3206 Před 3 měsíci +1

    Appreciate the lessons big mon.
    - New Subscriber

  • @5.poundz
    @5.poundz Před 2 měsíci

    Thanks for the great video.

  • @buggedmechanics
    @buggedmechanics Před rokem +2

    Best troubleshooting videos 👍

  • @jrh86
    @jrh86 Před 7 měsíci

    Great video on these units thanks

  • @elcrazy8017
    @elcrazy8017 Před 10 měsíci

    Keep the videos coming

    • @D2DNYAC
      @D2DNYAC  Před 10 měsíci +1

      Thanks for watching

  • @jimdefilippis9630
    @jimdefilippis9630 Před 3 lety +2

    Thanks for the video; lots of good information

  • @marcoselgaucho1106
    @marcoselgaucho1106 Před rokem

    Awesome, glad i came across your channel and gave you a shot!

    • @D2DNYAC
      @D2DNYAC  Před rokem

      Thank you for stopping by

  • @ABCJKE
    @ABCJKE Před 3 lety +3

    Thanks for taking the time to make the video for others.
    Be interested to know what you found out after letting it run a while and if you discovered if the winding insulation was deteriorating via the megger test at 500V. After it ran a while, the amperage imbalance or lack their of. You know, each legs amp added together, divided by 3, and then the % of deviation for each lag from the average. I mean thats just what came to my mind as I was viewing video.
    Enjoyed the low voltage portion the most.
    I've seen some motor overloads that have a N.O. contact that is wired to the contractor's auxiliary to "cut" the low voltage to the contactor coil, but I didn't see that on the video. So the motor contactor in your situation was still energized? Correct?
    Again, thanks and keep in the training mode.
    Jeff

    • @D2DNYAC
      @D2DNYAC  Před 3 lety +1

      Meg tested @ 500 & 1000 volts and the motor passed, the amperages was with tolerance, the overload doesn’t break the line voltages (please watch video again and look closer at OL) it only breaks low voltage (24v) from Q5 output

  • @jorgealtamirano6611
    @jorgealtamirano6611 Před 3 lety +2

    Very good info thank u for your time.👍🏼🙏🏼

    • @D2DNYAC
      @D2DNYAC  Před 3 lety +1

      Thank you for stopping by

  • @TylerArnold-wd1ip
    @TylerArnold-wd1ip Před rokem +1

    Good video. just an FYI they run those motor leads through that metal flex and it rubs the leads inside causing them to arc on the metal jacket when the unit vibrates while running. I had a unit tripping like this just recently thinking it was the overload just to come back with the overload tripped and a blown fuse

    • @D2DNYAC
      @D2DNYAC  Před rokem

      Thanks for watching my friend

  • @sparkytech8787
    @sparkytech8787 Před 2 lety +2

    Love your talk through, Brother you need a head cam so you could yous both hands.

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +2

      Thanks for stopping by

  • @MrBojax4u
    @MrBojax4u Před rokem

    Good job...if your in NYC, possible brown out or power dip in building. Liebert overloads are sensitive as hell

    • @D2DNYAC
      @D2DNYAC  Před rokem

      Thanks for watching ... NYC 💯

  • @user-mm1cl7ez2h
    @user-mm1cl7ez2h Před 2 měsíci

    Yes I’m referring these to my tech buddies

    • @D2DNYAC
      @D2DNYAC  Před 2 měsíci

      Thanks for watching

  • @teaglac3824
    @teaglac3824 Před 2 lety

    Awesome video! Much appreciated.

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +1

      Thank you for watching

  • @user-dk7uo2qb7f
    @user-dk7uo2qb7f Před rokem

    Давно отказался от использования тепловых реле. Очень низкая надёжность. За видео спасибо🖖

  • @soloch69
    @soloch69 Před 2 lety

    Great video keep them coming

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +1

      Thank you for stopping by

  • @HVACSystem
    @HVACSystem Před 2 lety

    Good work 👍✅ ok

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      Thanks for stopping by

  • @mattwoodbridge7924
    @mattwoodbridge7924 Před 2 lety

    Excellent videos

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +1

      Thanks for watching

  • @biblebloopers946
    @biblebloopers946 Před 3 lety

    Good troubleshooting bro

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      Thank you for stopping by

  • @fredrosas2575
    @fredrosas2575 Před 3 lety

    Great channel 👍👍

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      Thanks for stopping by

  • @chevaughn1993
    @chevaughn1993 Před 8 měsíci +1

    Are you familiar with Liebert units with the economizer pump package?

    • @D2DNYAC
      @D2DNYAC  Před 7 měsíci +1

      Yes I believe I do

    • @chevaughn1993
      @chevaughn1993 Před 6 měsíci

      @@D2DNYAC I keep getting intermittent “Pump fail to start” alarms and cant figure out why. Any suggestions?

  • @yoleysi72
    @yoleysi72 Před 7 měsíci +1

    I have a Liebert Model: PX011UA1A8B679, the set point is 23 degrees Celsius and 12 dew point, the problem is that the temperature drops to 18 and the humidity does not drop below 70%, it has resistors, 24 volts do not reach the coil of the resistance contactor, the password I entered is 5010, Greetings.

    • @robomaniac8
      @robomaniac8 Před 7 měsíci +1

      Try password 2210, it gives you 3rd level access on all Liebert systems.

    • @yoleysi72
      @yoleysi72 Před 7 měsíci

      @@robomaniac8 Before the resistors there is a contactor and a card has a fixed red LED, could it be that the card has been damaged or could it be some parameter that the card has a red LED?

    • @D2DNYAC
      @D2DNYAC  Před 7 měsíci +2

      Does your liebert have dehumidifier option? If yes lower the humidity setpoint. Here it will run the cooling and the electric heaters simultaneously after room temperature setpoint has been obtained, to remove humidity. In the event your liebert don't have dehumidifier option or the electric heater don't work, this will cause room temperature to fall well below setpoint while in dehumidifier mode

    • @D2DNYAC
      @D2DNYAC  Před 7 měsíci +1

      So you can go into setup option and disable dehumidifier or raise humidity setpoint however not to high because now you activate humidifier mode necessary if it available

    • @D2DNYAC
      @D2DNYAC  Před 7 měsíci +2

      If heater not working or unit not equipped with electric heater

  • @RJMaker
    @RJMaker Před 3 lety

    Blower contactor visual and voltage drop test. I know you said you would just replace it with the OL, but that's just changing parts not diagnosing. :-) Yea... I giving a little bit of crap... Thanks for the video.

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      Indeed everything checked out and passed. Amperage ,voltages, resistance, even mega ohm the the motor no problem found

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      It was an intermittent malfunction between the overload and contactor

    • @jeremydixon3470
      @jeremydixon3470 Před rokem +1

      Might as well replace the contactor while your at it lol cheap part that can possibly save a call back

  • @billderby1527
    @billderby1527 Před rokem

    One would think that the overload at the time of your checking the motor windings would have been open. Suggest in future you make this check at the load side of the overload

    • @D2DNYAC
      @D2DNYAC  Před rokem

      These isn’t connected to motor windings circuits !

  • @yoleysi72
    @yoleysi72 Před 6 měsíci

    Good Afternoon, I have a Liebert model: PX011UA1A8B679, the set point is 23 degrees Celsius and 12 dew point, the problem is that the Card Model: 416441G burns, the red LED lights up, it is the one that activates the contactor coil. the Resistor, that card receives 24 v from the main card and has a 24 v output for the contactor coil, could you help me please, Regards.

  • @KH-kv2yq
    @KH-kv2yq Před 2 lety

    Great video! Can you show the use of the meg ohm meter?

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +1

      czcams.com/video/HflhVFC8USU/video.html

    • @D2DNYAC
      @D2DNYAC  Před 2 lety +1

      czcams.com/video/yZAgh1O0OVA/video.html

  • @hariranormal5584
    @hariranormal5584 Před 3 lety

    god the hvac room sounds calm

  • @trinito97
    @trinito97 Před 4 měsíci

    But what was the motor rating amps?

    • @D2DNYAC
      @D2DNYAC  Před 4 měsíci

      Thats a Good question

  • @user-dk7uo2qb7f
    @user-dk7uo2qb7f Před rokem

    Tyron is your name?

  • @D_Nice981
    @D_Nice981 Před 3 lety

    👍

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      Thank you for stopping by

  • @moonlightacmaintenance3232

    Whoever changed those filters recently left the panels open with no filters in it for to long more than likely and over amped it.

    • @D2DNYAC
      @D2DNYAC  Před 3 lety

      Possibly

    • @peteandreas8850
      @peteandreas8850 Před 2 lety

      I have seen a unit trip when filter replaced without turning the unit off and also seen the unit trip when testing smoke and fire alarm panels causing the blower to stop

  • @user-ol4sw6rm3h
    @user-ol4sw6rm3h Před 5 měsíci

    Real time badness!!

  • @b16al
    @b16al Před 3 lety

    Yo bai!!

  • @user-ol4sw6rm3h
    @user-ol4sw6rm3h Před 5 měsíci

    🇯🇲🇧🇸

    • @D2DNYAC
      @D2DNYAC  Před 5 měsíci

      Thanks for watching brother

  • @alikhalid76dxb
    @alikhalid76dxb Před 3 lety

    Dee 2 deee nnnn yyyyy
    I like it

  • @PBS-nm1uu
    @PBS-nm1uu Před 2 lety

    confusing, should start with sequence of operation.

    • @D2DNYAC
      @D2DNYAC  Před 2 lety

      Thank you for stopping by