- In this video I will explain
1. Importance of Boundary Wall
2. Thickness of BFS
3. Thickness of PCC
4. Depth of Footing
5. Thickness of Wall
6. Size of Tie Beam and Column
7. Height of Wall
8. Distance between 2 Column
9. Reinforcement details of Tie beam and Column
10. Coping Thickness
Dream House Construction Steps Series
• DREAM HOUSE CONSTRUCTI...
⓿My Playlist Link
✔HOW TO STUDY DRAWING
• How To Study Drawing
✔CIVIL INTERVIEW
• Interview
✔CHECKLIST OF CIVIL WORKS
• Checklist of Civil Works
✔BBS (BAR BENDING SCHEDULE)
• BBS (Bar Bending Sched...
✔QUANTITY ESTIMATE
• Quantity Estimate
✔CONCRETE VOLUME CALCULATION
• Concrete Volume
✔IS CODE LECTURE
• IS CODE LECTURE
✔DREAM HOUSE CONSTRUCTION SERIES
• DREAM HOUSE CONSTRUCTI...
✔HOUSE CONSTRUCTION
• House Construction
✔HOUSE PLAN
• House Plan
✔CIVIL EXPERIMENTS
• Experiment
✔SURVEYING
• Surveying
✔CIVIL ENGINEERING TALK
• Civil Engineering Talk
****************************************************************
Official Website in English: www.learningtechnologyofficia...
Official Website in Hindi: www.civilofficial.com
****************************************************************
⓿Download my App FromPlaystore
✔ Civil IS Code App
play.google.com/store/apps/de...
✔ L&T Official App
play.google.com/store/apps/de...
✔ App For Interview Papers
play.google.com/store/apps/de...
****************************************************************
⓿About Channel
✔L & T - Learning Technology: This channel contains Technical Lectures on "Civil Engineering" from Personal Field Experience by Civil Engineer Mukesh Sah.
✔Email Id for Business Enquiry - civilengineeringofficial@gmail.com
✔Twitter: / themukeshsah
✔Facebook Page: / l-t-1681713582078656
✔Pinterest: / learningtechnologyoffi...
✔Instagram: / learningtechnologyoffi...
✔ Linkedin: / civilengineermukeshsah
#CivilEngineerMukeshSah #CivilEngineeringVideos #LearningTechnology #BoundaryWallConstruction
#DreamHouseConstructionSteps #L&T-LearningTechnology
Tie Beam ko yaha main Plinth Beam Bolna Bhul gaya hu. Iske lie maaf kijiyega. Baki ka Video ko Like aur Share kar ke apna pyar mujhpe jarur dikhaye. Thanks
Make video on shear wall. Reinforcement details of wall in high rise building spanning 60mts above
Sir compund wall ka column eccentric rakhna padega na?? Nahi to footing dusre ke plot mein ghus jayega na??
Sir ,,niche footing ka nahi batya ,jali ka kaise kitna
@@rohankharbanda5918 well point
Coloum ka jo base me jaali bNega wo ketna mm ka rod rahega
Informative video
बहुत अच्छे जी 🙏🙏 जानकारी के लिए बहुत धन्यवाद देता हूं।
Most important "HIGHLIGHT" or USP of this entire video..is the explanation behind 'why putting 2nos. 12mm dia in upper & 2 nos.10mm dia still in lower tie beam... EXCELLENT 👍👍👍 Rest 4 nos. 10mm dia can easily manage in upper plinth beam...thanks🙏
Great ! basic fundamental explanation for layman who intend to build boundary wall structures for their own homes 🙏
Apne bahut good explanation ki ,achi tarah se Samj me aa gaya,🙏
Nice one bro❣️
Excellently described . Thanks .
Thank You Very Much... You are One of My Best Teachers... Love You so Much... If Possible... I'll Meet You One Day
Very Good
Bahut Badhiya jankari diya aapne sir.
thanks a lot sir
Mukesh Dada apnar lecture Khub Valo laga
My favorite civil Er channel😍😍😍😍
Mukesh Bhai.. bahut zabardast
Very nice.
Concise . Thank you
I think u r the best in INDIA nice teaching technic & more helpful for freshers
Bahot badiya sir 🔥🔥🔥
Good video
Informative
Bahut Acha excellent
very important Lecture! Thanks
great video keep it up. god bless you.
BHAGUT ACHAA BHAI
Very nice way of explaination
Detailed info.thanks
Very well explained sir
Very nice explaination Thanks .Wish you all the best
Great video sir
Very well explained
Ur videos are informative
V.v. good presentation Sir.
Thanks
GREAT BRO.
Tq sir it's very useful
Very Nice Sir...
Excellent...
In short an Excellent 😘😘😘😘 ummah
Nice information and explanation keep it up sir
वहुत अच्छा
Thank you for your video
Well explained👍
Excellent sir
Very Interesting
Thanks for explaining in easy way.👍
Most welcome 😊
Thank you sir jii
Nice information sir.
Thanks sir
Thanks.sir.
very informative video sir
Apke samjhane ka tarika accha hai sir , Apke jayse guru ke margdersahan se hi week student v apne aap ko good student ban sakta hai
Ap bhi sikho apne juniors ko v sikhau
Thanks sir....👍👍👍👍
Very good 👌🏻👌🏻👌🏻
Super sir
Thanks🙏 Sir
Super video sir
Super
Awesome.
Nice video Sir.
Thnku sir I agree with u sir g
Excellent
great sir
Very good presentation 👏 👌 👍 💐. Now tell me while erecting the barbed wire on the top, is the wall likely to get weaken or shorten the life span of the wall?
No
Very nice
Good informative video bro keep continue hard work 💪and all the best 👍
Sir your describing way is awesome...
Thanks
Good
Very nice plz boq of this boundary wall
thanks bro....
U welcome
Sir mn apka bht purana subscriber hoon or mjjy bht kushii ho rii ha k ap wapiss active ho gaye hain apny channal pr.... Sir aik request ha mairii k aap koii aik project lay kr uskii dwg perhna or uska total estimate nikaln pooori video series dalain proffesional project kii...... Tnxx & love from islamabad 🇵🇰
Bahut badhiya jankari hai sir. 5" wall me coulm ki distance kitna rkhe
Nice
Very knformative. Pl let me know plinth beam function design etc for compound wall
🙏 🇮🇳 👍 😍
Yes
💯👌👌👌
Sir kindly post detailed building estimation i.e quantity calculation abstract,rate analysis ..And give it's excel link..🙏
Thanks ..
Do we need to provide expansion joint if the length of wall is more than 100m? If yes, then at what interval?
Sir , If we fill murram inside compound wall for a height of 5 feet and total wall height 10 feet above ground video me bataya jaisa ban sakte kya?
hi we are currently building a house and our builder happens to implement a new technique in building the compound wall for our site, he is extending the ground level beam of the house from the inside to the outside and putting a continuous beam for the compound wall and connecting it with the building beam(its not like a beam on a beam, but just connecting in same level). please give your opinion about this type, thank you
Sir, water supply schemes k liye bhi koi vedio bna de.. jisme WTP, Intake structure and overhead tank construction ka whole process bata de.. plzzzzzz
A process long life hoga sir ji
Dear Mukesh ji, one question.. if I wanted to have a room at the boundary wall then what would be the changes or modifications. Pls answer
How to laying crank bar at slab according to IS CODE plz sir and also show site images
As you mentioned thickness of PCC and Rcc to be 75 mm, Also share What should be the dimension of Platform (Horizontal and Vertical Dimension ) of Same
Brother Mukesh. Pls prepare construction cost details for compound wall with pillars.
Nice info. 👏👏 . If 3"rcc wall 6'height with 6mm sariya at 1'×1' se banaye aur plenth beam coloum 13feet par de to kitna kharch hoga.
Verry good suggestion sir
Thanks
Very good sir
@@pravinbahipatel7127 I want pricast boundary wall construction.
Sir ,mere boundary wall main nise 1.5 foot hi diya hain... Future main koi dikkat aiyegi kiya sir??
Sirb thank you for plinth beam teaching . Accordingly you taught to use 12mm at top otherwise use all four rods 10mm apart frlom this rwo option , may we apply 12mm on all these four rods of plinth beam .
Industrial boundary height and residential height different, height maximum is 1.5 Meter in Residential area
Dear Mr Sah, what will be the approximate cost for construction of 100 feet long boundry wall of 10 inch thickness and 6 feet hight. All specifications as per your video. Please include labour cost also. Thank you.
Can we make same type of Boundary wall with 4 inch Brick wall thickness, Remain all we will keep same as you are suggesting?Asking regarding 🧱 Brick Thickness 4 Inch instead of 9 inch
Sir compund wall ka column eccentric rakhna padega na?? Nahi to footing dusre ke plot mein ghus jayega na??
Yes
as ur fan, ur videos are too good, sir. 🙏🙏
I've a small doubt that, if we do trepizoidal footing r rectangular r square footing for a boundary wall column, it will go into the beside site, sir..? for this what we can do sir..?
nice bro,,,but u said u would explian about foundation part,,,missed it bro
Sir,
Thank you for your excellent explanation.
You are really a fantastic Tuitor. But sir,
You did not mention the width of the base column ( substructure )
Sir surverying pr bhi vedic bna de..
sir, stirrup ka spacing junction aur mid column me kam hoga kya?
If you don't mind then will you please show me measurements of starting structure of building
Plot ke Front me column bin ka distance kitna rakhna hai.
3 meter to aapne andar ka btaya
What about size of columns and footings tie beam please give details