American Standard Manual Flushometer | Installation | Repair and Replace

Sdílet
Vložit
  • čas přidán 6. 09. 2024

Komentáře • 14

  • @AmreSupply
    @AmreSupply  Před 2 lety +1

    *Note* Teflon tape, or pipe joint compound is not to be used on any connection that uses an o-ring or gasket. It is however needed on the brass control stop adapter. This was not shown in the video but will still help provide a leak proof connection.
    More information on teflon tape: czcams.com/video/9DhL0vet4gk/video.html
    Guide on pipe joint compound: czcams.com/video/a0jFPj4W8bY/video.html

  • @dylantoytebe8244
    @dylantoytebe8244 Před 2 lety

    Very clear tutorial

  • @loek2
    @loek2 Před rokem

    Was that turning right to lower water pressure for the flush and turning left to increase pressure?

    • @AmreSupply
      @AmreSupply  Před rokem +1

      Yes that is correct. The control stop is a screw. Turning the screw to the right, tightens the screw and closes the control stop.

  • @teddycummings9599
    @teddycummings9599 Před rokem

    Ok what if when you turn the water back on it continues to keep filling without stopping what causes that

    • @AmreSupply
      @AmreSupply  Před rokem

      Thanks for watching. It could be an issue with the piston: czcams.com/video/piuC89__cWg/video.html

  • @s1r3n1971
    @s1r3n1971 Před 4 lety

    Is it possible to attach a bidet or Muslim shower to this set up?

    • @AmreSupply
      @AmreSupply  Před 4 lety +1

      Thank you for watching. Overall there is nowhere to attach the bidet to a flushometer without doing a bit of work. You would have to install a tee to the pipe leading into the flushometer and connect the bidet to it with a shutoff valve. It would be more practical to connect the bidet to the sink's cold water supply.

  • @odineiacostanza5689
    @odineiacostanza5689 Před 4 lety

    Can the supply be half inch copper

    • @AmreSupply
      @AmreSupply  Před 4 lety

      Thank you for watching. The standard minimum diameter for an inlet for urinals is 3/4" and for water closets its 1". Without the right inlet the valve might not work properly.

  • @deek3048
    @deek3048 Před 5 lety

    What is the size of the copper pipe coming out of the wall?