40. Well control simulation , Simulator Control

Sdílet
Vložit
  • čas přidán 25. 08. 2024
  • in this video, the tool pusher and driller discussed the best way to get high marks in simulator . This video includes real simulator experiment about how to check for line up for stand pipe manifold, choke manifold, and active volume , then how to record slow pump rate for both pumps , then the instructions that must be given to driller and the drilling parameters to be used. Also, the tool pusher gives driller some instructions if he faced fast break, and the best way to make flow check .
    finally, when the kick occurs , the well is shut in in proper way and data was recorded like ( sicp, sidpp, pit gain) , then the kill sheet is calculated and finally, the kick is circulated with right procedures and the kill mud is pumped and flow check was done to well to guarantee the well is killed .
    #IWCF
    #IWCF_equipment
    #IWCF_simulator
    #drilling
    #workover
    #well_control
    #abdelaziz_gabr

Komentáře • 8

  • @brahimalgeria3208
    @brahimalgeria3208 Před 4 lety +1

    شكرا جزيلا أستاذي العزيز على كل هذه المجهودات .

  • @letslearntogether1198
    @letslearntogether1198 Před 4 lety

    Great Sir!
    It is really amazing video and I've learned good content from this video

  • @rebinsherwany1837
    @rebinsherwany1837 Před 2 lety

    Hello dear abdelaziz gabr ,i have watched all of your lectures of well control ,and I would like to express my sincere graduated for teaching me this course God protect you inshala. I would be delegated as well if you could share your well control PDF with me .

  • @khelifabeddief6980
    @khelifabeddief6980 Před 4 lety

    Thanks great job we need more sir

  • @nidharm3953
    @nidharm3953 Před 4 lety

    put some vdo about bottom hole assembly sir.

  • @waqasmehmood9047
    @waqasmehmood9047 Před 3 lety

    He is nawaz from pakistan

  • @Noxyy9999
    @Noxyy9999 Před 2 lety

    The hard shut in is wrong . He opened the remote choke which is suppose to be in closed position.
    He should open the HCR not the remote choke
    Step 1 .. space out the drilling string .
    Step 2 stop the pump
    Step 4 : close BOP
    Step 5,: open HCR
    Step 6 record data.
    Note the remote choke is already in closed position in hard shut in.