This EV charger install is wild

Sdílet
Vložit
  • čas přidán 5. 09. 2024

Komentáře • 82

  • @Mike_5
    @Mike_5 Před 7 měsíci +7

    The current trend for EV Chargers installation has led to a massive increase in Cowboy and Cowgirl jobs leaving everyone at risk

  • @electrician247
    @electrician247 Před 7 měsíci +4

    Thats what thinking inside the box does to you lol. The box that keeps on giving. I wonder if the shared earth via the din rail connectors and poor filtering in the EVSE is playing a part in those neutral currents as well. Which would be even worse than induced voltages/currents tbh. If they are allowing currents into the earth path it would explain seeing them on both Neutrals. Good find and great video as always.

    • @residualelectrical
      @residualelectrical  Před 7 měsíci +1

      Hahah it sure is, great point mark, hopefully I get back there again to mess around!

  • @allanharris9074
    @allanharris9074 Před 7 měsíci +3

    Thanks for the video Mike, Would have thought it would have been easier to have used the three phase to a local DB. Then done the circuits from there. Without sounding horrible to the trades out there. Possibly done by domestic installers. Again NOT disrespting anyone at all.

    • @residualelectrical
      @residualelectrical  Před 7 měsíci +4

      I think they wasn’t fully competent for sure! And yes that’s exactly what I would do, 3 phase sub main 👍🏼

    • @leexgx
      @leexgx Před 7 měsíci

      ​@@residualelectricalcould have installed 3 or 6 charging stations if they used 3 phase (unsure how many is running each phase here already) so much a mess on that install when your earth's are a bit hot like that (was the voltage high as well only seen amps here)

  • @darrenhemming2427
    @darrenhemming2427 Před 7 měsíci +2

    Many thanks for the video Mike, Looking at the regs and can't seem to find the part where it says the following is not permitted-" ** my thoughts are
    SWA cable with two individual circuits inside - ** so long as the grouping factors are taken into account
    Amoured cable used for earthing ** so long as ZS values and thermal constraints are meet
    What would be the difference if the charges had been wired in a single metal trunking used as the CPC, and single insulated conduit cables.
    2 x Separate CPC installed along with the armoured cable **. Earth leakage will always find an alternative path
    if you removed the two conductors wouldn't the
    current just find another path.
    I agree the work could be completed to a better standard
    Please keep the videos coming, enjoy the content.

    • @residualelectrical
      @residualelectrical  Před 7 měsíci +1

      It’s certainly permitted, but selection and erection needs to be justified and they haven’t made a good argument for their method.
      Thanks for the support on the videos, I wish I had more time on this one to see what’s really going on, I guess if you removed the earths it would leak down the earth of the DB, either that or it’s coming from the chargers, needs a deeper look 👍🏼

    • @chas3997
      @chas3997 Před 5 měsíci

      @@residualelectrical I think the hazards created by this shoddy install doesnt need BS7671 to tell you it could kill someone! 🥶⚡

  • @sergiofernandez3725
    @sergiofernandez3725 Před 7 měsíci +2

    Great content Mike. Really enjoyed it. Hope you get the job for the Cat A fit out. Would be good to see that site progress with partial rip out and new fit out.

  • @RossTheSpark
    @RossTheSpark Před 7 měsíci +1

    Rough as guts mate, harder to have installed it that badly than doing it right ! They should be TT’d especially back in 2015. Wouldn’t want the PME Exported to them

  • @garymcleanuk
    @garymcleanuk Před 7 měsíci +5

    Would love to hear feedback from the customer and you get the job to rectify it

  • @stunimbus1543
    @stunimbus1543 Před 7 měsíci +1

    So 3.9 amps in the neutral, 3.4 amps in the 2 g/y cables running to the adaptable box, and 0.5 amps in the main earth.
    Adds up rather well.
    That could be some sort of inductive coupling, or something more involved. This needs proper investigation.

  • @chas3997
    @chas3997 Před 5 měsíci

    Interesting about earthing to the earth lug first presumably to protect the cable passing through the distribution board first before it gets terminated in the main earth bar?

  • @arcadia1701e
    @arcadia1701e Před 7 měsíci +2

    Surely the earths to the car chargers being the preferred leakage path for the entire board, points to a high resistance main earth or high resistance sub Db earth.? Bad Ze ? But that is still a pretty high amount of constant earth leakage.

  • @hk.l4886
    @hk.l4886 Před 7 měsíci +1

    Usually I'm quite sceptical of other electrician's who criticises other electrician's work.
    But holy fuck mate, you are absolutely right. Whoever did this install had no fucking clue about any of the safety standards.
    Probably never did an electrical apprenticeship or is licensed.

    • @ironwolf6849
      @ironwolf6849 Před 7 měsíci

      He definitely has experience. He just needs guidance.

    • @residualelectrical
      @residualelectrical  Před 7 měsíci +1

      Yeah I’m not usually one to criticise beyond banter unless it’s dangerous, it’s not great to be honest, I only had 15 minutes to mess around on this circuit but the more time I spent the worse it got!

  • @Oufg103f
    @Oufg103f Před 7 měsíci

    It's amazing that they haven't had any problems with the EV board considering how old it is👍

  • @chas3997
    @chas3997 Před 5 měsíci

    Maybe should have separated the two phases on the run and TT it to earth, to grounded metal work, around 4 to 10 ohms and put an upfront type S 100ma RCD.
    Agree with you though about the installation earth fault current seems a bit high! Think this might be to do with aging equipment or old lighting ect.

    • @chas3997
      @chas3997 Před 5 měsíci

      Obviously with type A RCD protection as a minimum

  • @chas3997
    @chas3997 Před 5 měsíci

    EV install issues :
    Surveys poorly completed
    Being asked to complete EIC , Ohme paperwork ect, and configuring install all for one job!
    Being expected to knock 3 installs out a day!!!( too much)
    Customer has no idea about level of work required.
    Installer feels pressured in their roll to complete the task( very dangerous for fire risk and shock risk if all steps above aren’t completed properly!

    • @chas3997
      @chas3997 Před 5 měsíci

      Additional problem is I prefer to use a DNO box if there’s space but some DNOs don’t like this. But I also feel various ip68 outside fuse boxes carry risks if the get damaged which doesn’t happen to a DNO protected box

  • @TheKjwkjw
    @TheKjwkjw Před 7 měsíci

    Recognise that underground car park and office interior, pretty sure I would have used that charger back when we was based there.... Hatfield right :)

  • @joshuaprest1590
    @joshuaprest1590 Před 7 měsíci +2

    Mad that home made board surely it would cost mor money and time to make that then use like a rotary isolator or something on the lines of that. Unless it was a I've got this on the van job hehe. Good video enjoyed it very much

    • @residualelectrical
      @residualelectrical  Před 7 měsíci +1

      Definitely mate, they should of just supplied a three phase DB in an outdoor encoslure, must of been done for buttons or they aren’t competent

  • @imark7777777
    @imark7777777 Před 7 měsíci

    Considering that is a dual cable I wouldn't be surprised if they got the neutral swapped from the respective phase hot conductor as well. So blue 1 with brown 2 and blue 2 with brown 1. That is pretty sketchy could be worse not much.

  • @noahlind6786
    @noahlind6786 Před 7 měsíci

    I love watching your videos, as an American it gets a little confusing with the way your installs look especially because im not used to looking at iec breakers contractors and such but other that its great content

    • @noahlind6786
      @noahlind6786 Před 7 měsíci

      And y’all’s wire phasing is way different then how we do it over here

    • @leexgx
      @leexgx Před 7 měsíci

      No split phase here single phase, generally residential is 60A (old) 80A or 100 amps is plenty when using 240v or 3 phase (100A per phase and each phase can be a single 240v circuit, balancing is required)

  • @thomasjw_7408
    @thomasjw_7408 Před 7 měsíci

    Would you do an updated tool bag tour if you’ve changed anything what still works etc?

  • @samuelanderson1338
    @samuelanderson1338 Před 4 měsíci

    That’s a Del Roy type job

  • @Bubatronic303
    @Bubatronic303 Před 7 měsíci

    The horrors that lurk, how could anyone come away from that install thinking "I'm happy with that" ? 🤔

  • @philpearson1714
    @philpearson1714 Před 7 měsíci +1

    EV charging in an underground car park could have a really bad outcome with a pi$$ poor installation. Luton airport on steroids.

  • @sberry25
    @sberry25 Před 7 měsíci

    Interesting that the neutral and cpc currents were so similar. 🧐

    • @residualelectrical
      @residualelectrical  Před 7 měsíci

      Indeed, needed more time to look into it but it’s definitely leakage

  • @JRCElectrical
    @JRCElectrical Před 7 měsíci +1

    Some stuff amazes me, it surely would have been a lot easier to just do it all properly 😂😂😂

  • @tomorichard
    @tomorichard Před 7 měsíci

    Crazy enough nothing in BS7671 has issue with this!

    • @abdulseaforth6930
      @abdulseaforth6930 Před 7 měsíci +1

      That’s because the big book is for guidance only, utilised by those who now what they’re doing!

  • @starburst2203
    @starburst2203 Před 7 měsíci

    love how they put mcbs in and they do absolutely nothing

  • @Ronny86_
    @Ronny86_ Před 7 měsíci

    Top video as always Mike.. very informative
    Out of interest what app were you using to document the issues?

    • @residualelectrical
      @residualelectrical  Před 7 měsíci +2

      Thanks mate!
      It’s called sit audit pro, it’s about £15 but it’s really good and the PDF’s it automatically produces are wicked, not sponsored 👍🏼

    • @Ronny86_
      @Ronny86_ Před 7 měsíci

      @residualcurrent cheers mate I’ll have a look. Does look a really good app

  • @yrification
    @yrification Před 7 měsíci

    charge master says it all really

  • @RichardArblaster
    @RichardArblaster Před 7 měsíci

    Seems like the Lone Ranger passed through 😆😆😆

  • @johnsomerset1510
    @johnsomerset1510 Před 7 měsíci

    Very interesting, thanks.

  • @davideyres955
    @davideyres955 Před 7 měsíci +1

    Did they fit a place to part their horses when they fitted the EV chargers😂

  • @scotty2hottyltd
    @scotty2hottyltd Před 7 měsíci

    Ouch!!

  • @persona250
    @persona250 Před 7 měsíci +3

    Hi Mike . That is a rough one . Could have tested the voltage between the disconnected cpcs and earth bar .
    Could be induced voltage with all the cables sharing the trunking with the energised fuseboard adjacent.
    Could be an earth rod down there somewhere.
    Concrete will conduct especially when wet and rebar in it .
    Resistances are in parallel with each other and will share the voltage/current in proportion to the resistance of the path .

    • @residualelectrical
      @residualelectrical  Před 7 měsíci

      Great points mate, wish I had more time too see the direction of current flow etc, maybe I’ll be able to dig deeper! 👍🏼

    • @chas3997
      @chas3997 Před 5 měsíci

      @@residualelectrical the fault running down that redirected TNCS earth fault has to have a better path than the existing Earth so I would look for any bonding to structural steel work or if they’ve used a supplementary earth rod somewhere. All very hazardous ⚠ ( you also need to be sure your neutral csa is suitable and where it’s feed from )

  • @ironwolf6849
    @ironwolf6849 Před 7 měsíci +1

    Personally, it does not look like a bad install.I mean its not super duper neat but to be honest it looks allot better than allot of work you'll find here. Plus it does look like he put in quite allot of care in what he did and there is allot of detail that people would not even care about here. Like the box might not be 100% IP rated but hes got his grommets in and stuff. I would instead have taken it in from the bottom tho. But you did give me a few things to think about . And I personally think with a bit of guidance whoever did that job will do well.

    • @moop_fogo
      @moop_fogo Před 7 měsíci

      I had similar thoughts. I would not call this cowboy on the scale of things. the install is quite neat for an improvised setup, although it's all irrelevant when it is also dangerous. it's easy to become complacent when you've convinced yourself you know what you're doing.
      He should check out some of the crazy old installs you'll find here in the us..

  • @shawnshawn911
    @shawnshawn911 Před 7 měsíci

    Interesting issue.
    What the app you use to record your assessment and errors?

  • @rscelectrical7091
    @rscelectrical7091 Před 7 měsíci

    I don't do EV but even I can see that's a quality install Mike 😱😂

  • @stephenllewekyn706
    @stephenllewekyn706 Před 7 měsíci

    Very good video.

  • @wolvolad25
    @wolvolad25 Před 7 měsíci

    4 amps is lethal? Wow

    • @gege12372
      @gege12372 Před 7 měsíci +1

      Currents between 100-200mA have been proven to be lethal in the right conditions. That's the reason RCD protection is normally rated at 30mA

    • @chas3997
      @chas3997 Před 5 měsíci

      Anything above 30milli amp can be lethal 300 milli amps is 10x that!

  • @andrewbevan4662
    @andrewbevan4662 Před 7 měsíci

    What "were" they thinking ...

  • @scrannefrank6006
    @scrannefrank6006 Před 7 měsíci

    Does anyone know anywhere stocking Boddingtons at a reasonable price only place I can find are charging £80 for 5 drivers

    • @charliechan22
      @charliechan22 Před 7 měsíci +1

      Halfords Advanced EV 1000V Insulated 6 Piece Screwdriver Set. £43 apparently boddingtons but branded Halfords

    • @scrannefrank6006
      @scrannefrank6006 Před 7 měsíci

      Yeah I’ve seen only gripe is they’re ph and not pz and don’t have the 4.5 slotted but it might just had to do with

    • @charliechan22
      @charliechan22 Před 7 měsíci

      @@scrannefrank6006 only plus point for the Halfords is it's the advanced lifetime guarantee

  • @paulmullane9662
    @paulmullane9662 Před 7 měsíci

    😮

  • @urisluss929
    @urisluss929 Před 6 měsíci

    Promo SM ☝️