FULL Electrical Rewire from Start to Finish

Sdílet
Vložit
  • čas přidán 7. 09. 2024

Komentáře • 178

  • @artisanelectrics
    @artisanelectrics  Před rokem +10

    Big shoutout to Doncaster Cables for supporting this episode. Make sure you check them out in the links below!👇
    Website: bit.ly/3IDLHLo
    Instagram: bit.ly/3Dz7c04
    LinkedIn: bit.ly/3D8S0Wa
    Facebook: bit.ly/3SHZsgy
    TikTok: bit.ly/3FmbAki
    Want to know more about EV-Ultra? bit.ly/3o02JLR

  • @theowebsterelectricalservices

    I must say I do agree with johns comment about commercial sparks looking down their noses at domestic sparks. I’ve worked a lot in both sectors and I must say domestic offers up a whole different set of challenges that you will never come across in commercial or industrial work. Great work guys 👌🏻👌🏻 also he said about putting the carpet grippers in window sill 👌🏻 top tips from me aswell, if it’s a furnished room take a photo before you start so everything goes back how you found it and number all your floor boards so you know where they go back to 👌🏻 great work team artisan

    • @Ahmedsunz
      @Ahmedsunz Před 6 měsíci +1

      Would you recommend domestic or commercial and where to strat commercial journey from if so ?

    • @theowebsterelectricalservices
      @theowebsterelectricalservices Před 6 měsíci +1

      @@Ahmedsunz i would recommend both ! As they both will provide you with different skills and knowledge. If your going self employed don’t expect to just get a lot of commercial work it takes time to build up that client base along with a good reputation

  • @discomonkey3492
    @discomonkey3492 Před rokem +12

    Loved being a sparky in the 80s..sadly the army turned me into a mechanic, then hydraulic fitter.. really miss being a spark- happy days! trained to the 15th edition lol. Respect to the modern day electricians !

  • @CShand
    @CShand Před rokem +4

    Great video as always. It would have been great to see in more detail how you deal with the existing cables and how you secure them in the chases

  • @NBundyElectrical
    @NBundyElectrical Před rokem +65

    im impressed it didn't take 3 weeks again 😅

    • @artisanelectrics
      @artisanelectrics  Před rokem +31

      Do I know you?

    • @waynelofts7864
      @waynelofts7864 Před rokem +3

      How come you only use 2 blades in the hilti Chaser and not 3?

    • @stupot_64
      @stupot_64 Před rokem

      @Gabriel jackson Mrs Jessica Liam killed my dog and made a stew with him. Do not deal with her.

    • @anthonycampbell9807
      @anthonycampbell9807 Před rokem +5

      You need a disc on your wall chaser like Nicks, that’s a game changer.

    • @marksimpson3035
      @marksimpson3035 Před rokem +1

      Not 3 weeks , took them a month 😯

  • @peteh4666
    @peteh4666 Před 5 měsíci

    Love your work lads - greetings from Ireland. Worked in industrial maintenance myself. My good hint as regards floorboards - set the circular saw depth using a piece of sample floorboard to just below the bottom of the tongue itself - not the bottom of the board. That way, there is still a margin of error of approx 4 - 5 mm and you still get to cut off the tongue without going all the way to the bottom of the board itself and possibly nicking other pipes or services. Worked for me every time. Would love to have served an apprenticeship with ye if I was starting out over again.

  • @ItzD3fW1sH
    @ItzD3fW1sH Před rokem +4

    CU looked amazing Luke. Nice one

  • @declang565
    @declang565 Před rokem +2

    I always mark across the floor boards with my black sharpie saves time when your trying to find them to put back down

  • @tc6907
    @tc6907 Před rokem +10

    Great video! Nice to see some rewire work.. didn’t know you guys like to get dirty tho 😂
    You definitely need to invest in a Metabo triple blade chaser

  • @Ragnar8504
    @Ragnar8504 Před rokem

    I once managed to short out two phases on a 35 amp supply, the bus bar of one phase poked through the insulation of another phase conductor. These days DIN rail boards have fully insulated 3-phase bus bars but that was an 80s board that I was just jiggling around. When I was done I screwed in the main fuses at the meter, measured voltage at the board, all fine. No IR testing because it was my own place and late in the evening and everything, you know how you get negligent sometimes. Turned on the RCD in the outbuilding and measured again, everything dead. The short had blown two main fuses (D02 Neozed bottle fuses) without any bang or even a fizzle. Luckily I had spare fuses so crisis averted. I'm still surprised the whole event was so quiet! Usually even an L-N short on a final circuit results in quite a bang.

  • @jgharston
    @jgharston Před rokem

    Oooo, I love factory tours. When I was doing my EE back in the '90s, we had a tour of Drax and Hartlepool Nuclear. :)

  • @benjaminh860
    @benjaminh860 Před 2 měsíci

    Can you also do a video on how you rewire wet rooms - bathrooms and kitchen? thanks

  • @andrewd762
    @andrewd762 Před rokem +3

    Don't worry, everyone makes mistakes that result in a big bang at sometime, it's a steep learning curve and you won't do it twice.
    Looking on the bright side, when you accidentally connect 3 phase into a board that's linked out for single phase supply the several thousand amps fault current means the fault is cleared nice and quickly by the supply side fuses.

  • @callumsimpson7483
    @callumsimpson7483 Před rokem +3

    Really good tip I robbed off someone the other week if you put a screw in the little hole on a wood saw you can use the magnet on the laser level and slide it up and down. It’s actually a game changer 😂

  • @SteveNail
    @SteveNail Před rokem +9

    Put some insulation tape on the back of those coach light pins, It'll stop them pushing back whilst you fix it.

    • @adamsmithelec
      @adamsmithelec Před rokem +1

      I do this now after once losing a pin down a drain in garden I was working!

    • @markpotter8280
      @markpotter8280 Před rokem

      @@adamsmithelec my experience on coach lights is make sure the pins are flush with the brick and not in the mortar line, that being said if your lucky enough to mounting them on a flat brick wall

  • @johnavery15
    @johnavery15 Před rokem +4

    You need to buy a Faithful Nail Puller. Makes easy work of floorboard nails. I drill a 6mm hole either side of a nail so I don’t have to hammer the nail puller in too much.

    • @Simon350S
      @Simon350S Před rokem +1

      Never seen one of those…. Added to my new tools list 😍

  • @simonpamplin5714
    @simonpamplin5714 Před rokem +1

    Wish my board looked as neat at that - nice job !

  • @discomonkey3492
    @discomonkey3492 Před rokem +5

    Back in the 80s we used a lump hammer and boaster chisel to lift floor boards :)

    • @lotuselise4432
      @lotuselise4432 Před rokem +2

      I used to also have a floorboard saw with the curved/rounded end if they needed to be cut.

    • @andmacmac6899
      @andmacmac6899 Před rokem

      L i l noo iki mloll m ll o l l l l o olkl lolo loiok. N@@lotuselise4432 of our lo lip look l lip nnnn

  • @mattwhitley9315
    @mattwhitley9315 Před rokem +13

    Seems to be johns way or no way… patterns emerging over a few weeks

    • @hb4782
      @hb4782 Před rokem

      What a bitchy comment 😂Not really he seems pretty chill. Nothing wrong with taking a bit of charge. Prob what he’s instructed and paid to do.

  • @philipsmith0752
    @philipsmith0752 Před rokem +1

    good Video John Lee and Luke team work the Artisan way

  • @sgrb11
    @sgrb11 Před rokem +4

    I would like to see more footage on how you feed/fish cable behind walls and ceilings etc please!

  • @KieranStanley
    @KieranStanley Před rokem +3

    We always use doncaster cables, best cable by a mile nobody comes close.

    • @artisanelectrics
      @artisanelectrics  Před rokem +1

      It’s amazing 🤩

    • @TheChipmunk2008
      @TheChipmunk2008 Před rokem +1

      With us for power, it's either Doncaster or Prysmian... for Cat6 and stuff it's Doncaster

  • @Spark101.
    @Spark101. Před rokem +8

    450 and 1200 are for new builds to adhere to building regs that cater for disabled living. When conducting a rewire, the client can have the heights they want as long as its practical. Personally……350 to the bottom of sockets and 1300 to the bottom of switches is the sweet spot for most of my clients.

    • @gadgetman36
      @gadgetman36 Před rokem +1

      350 is too low for sockets. People shouldn't need to get on their hands and knees. 450 is the normal height for sockets. For disabled living sockets need to be much higher, I'd say 900.

    • @Spark101.
      @Spark101. Před rokem +2

      @@gadgetman36 You’re wrong

    • @fredkeogh9035
      @fredkeogh9035 Před rokem

      I was interested lifting the floorboards and yes the worry of hitting pipes etc, nothing changes on that score ‘

  • @nfkvbfvbsduhbccucuhc
    @nfkvbfvbsduhbccucuhc Před rokem +1

    Can use fire rated board to mount CU too, makes sense if your trying to maintain safety !

  • @crabmansteve6844
    @crabmansteve6844 Před rokem +2

    All this stone looks like a nightmare. Makes me happy that we more often than not timber frame here in the US.

  • @glasgowrewires
    @glasgowrewires Před rokem

    Cracking video. Very good details on each aspect mentioned.

  • @martinburgess2322
    @martinburgess2322 Před rokem +3

    Lads I hope your treating Luke to another few burgers,
    Fair play Luke that's a neat tidy board 👊nice job😃👍

  • @benjaminh860
    @benjaminh860 Před 2 měsíci

    Hi, thanks for this. My house needs a full rewire which I'm happy to get done. But i need to save up for about 6 months before I do any other works inc plastering. After a house rewire, is it still liveable ? I'd get rid of all the dust and mess the electricians have made, but I'm wondering for the next 6 months, would it still be dusty? I don't mind the holes in the walls etc

  • @jonesconrad1
    @jonesconrad1 Před rokem +10

    Why didn't you ask the customer what height they wanted them.

  • @hjkglpojh1863
    @hjkglpojh1863 Před rokem +1

    In Germany we place the switches at 105-110cm and the sockets at 30cm above the floor. Interesting to see that you use 120/45cm these heights were often used in Germany untill the 1960s.

    • @WestSideConnection5
      @WestSideConnection5 Před rokem

      In belgium 110 center for a switch and 25 center for an outlet. But this is not a written rule

  • @neo214
    @neo214 Před měsícem

    You guys have inches over there? I measured my outlets and they're 35cm from the ground and the light switch is 130cm

  • @RaxTubeYou
    @RaxTubeYou Před 6 měsíci

    It's definitely best practice, though is it mandatory? Please share the BS7671 regulation that requires fire grommets for consumer unit cable holes? Or maybe Manufacturers instructions?

  • @geddylee501
    @geddylee501 Před rokem

    Great floorboard work

  • @TeamSimpsonRacing
    @TeamSimpsonRacing Před rokem +14

    I'll always let the customer choose the height of the new sockets and switches. Not all customers like the new heights and I'd never make that decision without consulting them

    • @Simon350S
      @Simon350S Před rokem +3

      Absolutely, was going to comment the same 👍

    • @sebperrin9797
      @sebperrin9797 Před rokem

      I still think it should be installed to the new regs anyway?

    • @will151989
      @will151989 Před rokem

      Not in an existing property@@sebperrin9797

    • @wil172921
      @wil172921 Před 11 měsíci

      New regs have standard heights for a reason. Build to the latest spec no issues then.

    • @shumble69
      @shumble69 Před 8 měsíci +1

      These height regs are only for new builds not existing properties.

  • @BarneySaysHi
    @BarneySaysHi Před rokem

    A shower in the bedroom. I've known a hotel that had that feature, but that was ages ago.

  • @Reddotreticle
    @Reddotreticle Před 7 měsíci

    This channel just basically shows diy Dave a full on instructional video of how to re wire your house. And then they’re amazed at some of the shoddy work they come across. With in depth videos your publishing you may come a cropper for liability some day

  • @StreamFeeds
    @StreamFeeds Před rokem +4

    Isn’t one of the things that you shouldn’t do is put the CU under the stairs now because it is a potential fire escape?

    • @r3co0
      @r3co0 Před rokem

      No, that's for a plastic consumer unit. No fire risk for a metal cu.

  • @calvinhale9913
    @calvinhale9913 Před rokem +2

    We love Artisan but they really shouldn't do rewires. It's going to be another 4week rewire judging by John taking up those boards like he's on Time Team. (with 2 blokes watching lol) - ear defenders on whilst taking up lung destroying 60yr old underlay - missing middle wheel in Hilti which would've churned up the rubble and center piece of plaster - and finally haha, always always always get the customer to determine positions and heights, give them a sharpie and follow them round on day one obviously advising where needed. Imagine doing all that and handing the keys back for the customer to say 'why have you done those sockets / switches that height ?' Easy to pick faults in others work just hoping it helps on the next one... you guys do amazing work in other areas that is top tier - keep it up !

  • @andrewdobson3518
    @andrewdobson3518 Před rokem

    The apprentice missed out on a lot of education with this one. These are the perfect jobs to bring them on with

    • @artisanelectrics
      @artisanelectrics  Před rokem

      Reuben was there we just didn’t film those days 👍🏻

    • @andrewdobson3518
      @andrewdobson3518 Před rokem

      @@artisanelectrics ahh that’s good news, I know I got a lot of my experience from those rewire days. I wasn’t trolling. I just thought he’d not ended up going there

  • @therealdojj
    @therealdojj Před rokem +1

    i didn't see that fancy marking out gadget that lee used to swear by when marking out boxes...has it been superseded by new fangled tech then?

  • @gadgetman36
    @gadgetman36 Před rokem +3

    I can't believe you are still wall chasing with 2 blades and a chisel bit in an SDS. Talk about doing it the dusty, hard, slow way. It's about time Jordan bought you guys a Metabo 3 blade wall chaser and dust extraction kit (or blag one free from Metabo like Nick did).

    • @rogerbean393
      @rogerbean393 Před rokem

      Just stick a 3rd grinding wheel between the spacer and the other 2,wheels then Just use a brink hammer so much quicker .
      They will be for weeks !

  • @christagg7570
    @christagg7570 Před rokem +1

    Surely after paying for a few man weeks of spark effort, the customer would replace that old underlay and carpet!!

  • @lesmoor001
    @lesmoor001 Před 24 dny

    how much would you charge for that job ?

  • @el-lex6822
    @el-lex6822 Před rokem

    Edeting is NOICE 🎉

  • @lotuselise4432
    @lotuselise4432 Před rokem

    I only did house bashing for the extra cash, for friends or my own house, stuff shifting furniture around and lifting carpets up, I mainly did commercial/industrial installs, 20 years old making off PYRO ends on a balcony in the snow at the V+A museum, brrrrrrrrr.

  • @thorvaldsson1
    @thorvaldsson1 Před rokem +3

    Great video guys - as always.
    The electrical structure of domestic houses in Britain makes me frustrated. And that you need to chase for every electrical outlet and switch - when doing a rewire - or fixing a damaged cable etc.
    Anyone know if they are going to make rules & regs so when installing a "hidden" cable (in wall, loft etc) you should be able to repull the wire witout opening floorboards or chasing down walls?
    Spark from Stockholm, Sweden

    • @quinnbattaglia5189
      @quinnbattaglia5189 Před rokem

      It's bizarre watching these videos as an american, our way has its own quirks but at least we can fish cables through walls.

    •  Před rokem

      In Germany often times plastic pipes are put into the walls, the floor and the ceiling. There are sometimes hidden trunks called a "Kabelkamin" there you can can switch between floors. In our house there is one big trunkin the wall from the consumer unit up to the roof and the cables branch off into the walls and ceilings.
      So this feels like a heck lot of work.

    • @carlmarquardt994
      @carlmarquardt994 Před 7 měsíci

      They dont bother thinking ahead for future

  • @chrisardern4594
    @chrisardern4594 Před rokem

    Talk about to many cooks this is a perfect example having only one in charge.

  • @joseville89
    @joseville89 Před 2 měsíci

    "Opening this box is just making me want to get a pizza tonight..." 😂😂

  • @persona250
    @persona250 Před rokem +3

    Sockets downstairs 450 ? upstairs not 450 ?

  • @leeedwards9994
    @leeedwards9994 Před rokem

    really nice work .....

  • @tc6907
    @tc6907 Před rokem

    Switch with lots of cables here…. 5 😂😂

  • @Herendill
    @Herendill Před rokem

    What protection glasses are you using guys? Looks good and has side protection as well

  • @DanAuty
    @DanAuty Před rokem

    Great video lads

  • @Sparks1Plumbers0
    @Sparks1Plumbers0 Před rokem +2

    Luke... them fire grommets. You don't cut them Criss-Cross style! You push the cable/s through to help maintain their actual use as a seal.
    5 hours in your cupboard eh... and how many more on actual tartting it up. 😉

  • @petertallowin6406
    @petertallowin6406 Před rokem

    The DeWalt laser owns that Hilti box right now..... Doesn't accessibility come in to play with a rewire? New builds are one thing but a rewire you aren't really matching in to existing like you would for say a few additional outlets.

  • @shoedil812
    @shoedil812 Před 4 měsíci

    21:22 Those leads (10mm² brown blue) are totally not up to code in our country.
    Can't have those leads exposed. Needs to be inside a flex or insulated (xgb we call it) when outside a junction box or lead pannel.
    Actually a big nono! Imagine nicking those (in our country 230V/ 40A)....

  • @cantbelieveimhere2935

    I'd like to see a video on how you go about pricing a job like this, considering you have 4 lads on it including Reuben and alot of materials (all cable) supplied FOC for "sponsorship". Do you charge for the material, do you charge for the extra time to film etc?

  • @mattlawlor959
    @mattlawlor959 Před rokem

    Love the channel boys, do you ever wire for low voltage points like bt/data etc?

  • @lukagrloci78
    @lukagrloci78 Před rokem +1

    We just put a quote for rewire of a 4 bedroom, 2 bathroom house and a future extension for 8K euros in Dublin! Ppl were outrageous!? Plenty of extra sckts, switches, new 2x 10mm showers, new main, iso switches, new panel, etc... All solid walls!!! Good luck if thay can find a spark to do it under our price!

    • @hks-lion
      @hks-lion Před rokem +1

      Out of interest, roughly how many hours of work would that be?

    • @richardwalsh5882
      @richardwalsh5882 Před rokem +2

      Sounds far too cheap to me. I'd charge more than that in Donegal.

    • @lukagrloci78
      @lukagrloci78 Před rokem

      @@hks-lion about 6-8 days for two of us! Lets say around 50x2 working hours!

    • @hks-lion
      @hks-lion Před rokem

      @@lukagrloci78 fair I think €8K is a decent price

    • @lansdorf
      @lansdorf Před rokem +2

      People expect rewires to be priced at 30 year old prices. I've just finished a rewire and when I've brock it down I've done it for £22p hour and it was a first class job and perfectly plastered up . Never again, from now on I'm doubling that rate and if they dont like it then get someone else.

  • @jonathanbaggaleyelectrical9185

    Think it’s 3m from a shower cubicle and for the irrelevant 450mm new build height I was always told it was centre measure. Keep up the work guys.

    • @TeamSimpsonRacing
      @TeamSimpsonRacing Před rokem +2

      Recently changed to 2.5M in the regs. 450mm is the bottom of a socket outlet

  • @thewaspe177
    @thewaspe177 Před rokem

    Rewires are stressful enough cany imagine filming it all

    • @thereal1006
      @thereal1006 Před 11 měsíci

      stressful lol i love getting stuck into a nice rewire

  • @conorjordan9029
    @conorjordan9029 Před rokem

    Love your work lads always nice and neath but any chance you could give the customer a decent door light. That 1940s yolk ya have them is a joke. Even a can uo down light .

  • @jooproos6559
    @jooproos6559 Před rokem

    Now try to do all this in een concrete house..Like they are in the Netherlands.

  • @adjithwk257
    @adjithwk257 Před rokem

    Every found treasure under the already lifted boards?

  • @ianhughes6766
    @ianhughes6766 Před rokem

    What is the cordless screwdriver your using in this video ? please

  • @ianmiller3182
    @ianmiller3182 Před rokem

    There seems to be some conflicts with guidance to heights with some giving centre's. 150, 450 and 1200.

    • @danbobnix
      @danbobnix Před rokem

      Always refer to building regs part M. Gives the acceptable mounting height of accessories between 450mm - 1200mm. I'd always go 450 bottom, 1200 top based on this.

  • @Shanky_TH9540
    @Shanky_TH9540 Před 5 měsíci

    the young lad talking about installing a there phase fuse board while the link kit was still fitted and energising it is pretty fucking scary tbh. the fuck was he doing it unsupervised in the first place is the question??

  • @chriscooper2342
    @chriscooper2342 Před rokem

    What clips do you use to hold the conduit in the cases?

  • @markbriggs6786
    @markbriggs6786 Před rokem

    Would be interested to see how much that cost and how long it’s taking, 3 of you on site in such a small house , did it really need a full re wire .

    • @crabmansteve6844
      @crabmansteve6844 Před rokem +2

      "Buy once, cry once."
      Now the homeowner has complete piece of mind about the entirety of the electrical system in their home. It's fully modernized now.

    • @markbriggs6786
      @markbriggs6786 Před rokem

      @@crabmansteve6844 yes but was it necessary I see this all the time rewires up sold when the system is sound and safe and all it needs is a slight up grade , the regs are used as leverage ,I agree if it’s fully necessary and it’s un safe then re wire it .

  • @Davybhoy25
    @Davybhoy25 Před 9 měsíci

    Boys…how much does an average rewire cost? There’s such a variation in quotes how are you supposed to know who to go with. I have a vacant small 3 bed terraced and was just quoted £7k plus vat even though all the carpets will be up and rooms empty. Hard to stay compliant when it’s unaffordable to the average person.

  • @andrewdobson3518
    @andrewdobson3518 Před rokem

    What’s these metal pencils with a green end I keep seeing everywhere and where do I get them from??

  • @SuPrAmAd101
    @SuPrAmAd101 Před rokem +8

    Im interested to know if youve done the rewire for a lower rate as doncaster cables supplied the cable?

    • @hb4782
      @hb4782 Před rokem

      Doubt it as it probably cost them more in filming/doing things as neatly/expensively as they were.

    • @SuPrAmAd101
      @SuPrAmAd101 Před rokem

      @@hb4782 yeah but they also get revenue from the video which i doubt gets passed onto customers, but you cant charge for materials if they were “supplied” especially as part of an advertisement

    • @hb4782
      @hb4782 Před rokem

      @@SuPrAmAd101 fair point

  • @fastestmilkman3840
    @fastestmilkman3840 Před rokem

    May i ask how much a rewiring like this will cost?

  • @nickspage4765
    @nickspage4765 Před 11 měsíci

    A neat job but extremely toxic on the lungs!
    I don’t think a torque driver was used on the board,
    This is key to avoid arcing or damaging cables .
    Usually theres a torque label in the board.

  • @thereal1006
    @thereal1006 Před 11 měsíci

    wonder how much you charged for this job ??

  • @johnc6343
    @johnc6343 Před rokem +3

    John, stop trying to hide your new gut. Embrace it brother. Lots of money went into growing it 🤣

  • @Ste2023
    @Ste2023 Před rokem

    Hi A.E ...what cu are using ...

  • @ryanstevens2457
    @ryanstevens2457 Před rokem +1

    Measuring from skirts 🤨 1:55

  • @stevenhastings1942
    @stevenhastings1942 Před rokem

    You can't put sockets where you like on rewires. Yes you don't have to put them 450mm to the bottom but you can't make them less accessible than they already were.

    • @Heathen.Deity.
      @Heathen.Deity. Před rokem +1

      Indeed. Don’t have to improve, but you can’t make it worse than before you started (relevant to Part M in this case).

  • @chrisardern4594
    @chrisardern4594 Před rokem

    Hey Nick Bundy how much do you think Jordan charged for this. Lol

  • @shaynemacdonald3051
    @shaynemacdonald3051 Před rokem +3

    Miss Corey just want him back 😪

    • @Simon350S
      @Simon350S Před rokem +1

      I’m sure you already are, but if not, go watch his new channel, it’s ace 👍

  • @dringonator6911
    @dringonator6911 Před 8 měsíci

    I don’t think I could do a rewire especially when you’re doing the wiring part and you got someone recording you. I just want to get in and get gone.

  • @shazzaoconner7776
    @shazzaoconner7776 Před rokem +2

    John digging people out for not cutting boards on the joist! Hypocrite 👍

  • @xatalinuxvictor9027
    @xatalinuxvictor9027 Před rokem

    The hight of sockets is 450 mm from the floor to the centre of the socket ....

  • @Shanky_TH9540
    @Shanky_TH9540 Před 5 měsíci

    that' chase down to the 3gang switch at the front door looked awful guys.. this video shows a lack of experience from this group. re wires are never easy but you guys could deffo benefit from having a old head in the group leading the way, even noticed you hadn't bent the top and bottom lugs back on the single boxes before plastering them in. also 5 hours to mount and second fix a easy fuse board like that is crazy

  • @yasinabi51
    @yasinabi51 Před 9 měsíci

    TH1AB

  • @shadeauto3373
    @shadeauto3373 Před rokem

    you guys need nick bundy lol

  • @binnieuk
    @binnieuk Před rokem

    If you were worried about hitting a water pipe could you not just use a metal detector

  • @NickP1707
    @NickP1707 Před rokem +2

    Todays hidden word is ‘agitate’ 😂

  • @paulrobertson4743
    @paulrobertson4743 Před rokem

    I've been doing rewires on average 5 a week for the past 20+ years. This was painful to watch

  • @marcgaskett
    @marcgaskett Před rokem +1

    I don’t understand why you UK sparks don’t just cut the ceiling plaster to run cables in a multi storey and just get it patched and painted afterwards at the clients expense. Surely better than all this lifting carpets and floorboards, far too much screwing around

    • @hks-lion
      @hks-lion Před rokem +1

      My guess is there’s not enough plasterers around, would take weeks or months to get them in.

    • @lotuselise4432
      @lotuselise4432 Před rokem +3

      The still would have to cut the joists and if its an older house with a wood lathe ceiling then you don't won't to start cutting runs in them.

  • @jc-fy1wl
    @jc-fy1wl Před rokem

    A shower in the bedroom. Are you rewiring a brothel?

  • @lansdorf
    @lansdorf Před rokem

    Dont like Doncaster cable its always twisted towards the end of the coils.

  • @zoltrix7779
    @zoltrix7779 Před rokem +1

    Such high quality standards in the UK yet the earth "CPC" still isn't insulated for the complete legnth.

    • @williammartinculleton5875
      @williammartinculleton5875 Před rokem

      We in The Irish Republic only use all insulated conductors throughout their length too, and NO ring final circuits ☘️

    • @zoltrix7779
      @zoltrix7779 Před rokem

      @@williammartinculleton5875 Same as Australia, we also have a 2.5mm2 earth in 2.5mm2 cable, however, C curve breakers are the norm.

    • @JorgeAMG187
      @JorgeAMG187 Před rokem

      @@zoltrix7779 C curve seems kinda High for a normal household. B should be the standard really

    • @AndrewStrydomBRP
      @AndrewStrydomBRP Před rokem +2

      That's actually a good thing, it means it is more likely to hit the neutral or live and trip the circuit instead of staying live when/if the cable is damaged.

    • @zoltrix7779
      @zoltrix7779 Před rokem

      @@JorgeAMG187 Well, thats the way it is. You can't even buy a B-curve breaker for the most part in Australia. It's pretty irrelevant if you fault loop is within spec for a C-curve.

  • @motivationhero7
    @motivationhero7 Před rokem

    Runinig bare cables even if its flat twin & earth, it's not upto code with our standard. Insulated either conduit or trunking depending on the type of installation.

    • @THECALLOF241
      @THECALLOF241 Před rokem +4

      No requirement for it in the uk

    • @xxhardnutsxx
      @xxhardnutsxx Před rokem +1

      we can if its on an rcd, or if can touch would use trunking ect for addition mechanical protection

    • @persona250
      @persona250 Před rokem +4

      @@xxhardnutsxx all lights and socket outlets in a domestic property require RCD protection regardless of installation method .

    • @TheChipmunk2008
      @TheChipmunk2008 Před rokem +3

      Clipped Direct is an acceptable method of installation (reference method C). Almost never used in occupied structures now due to appearance, except in roof spaces etc. But VERY common in sheds/etc.

    • @xxhardnutsxx
      @xxhardnutsxx Před rokem

      @@persona250 yh my bad lol, meant when or because it on rcd and would use trunking for apperance, time for bed Im waffeling

  • @user-gh2rk4st4o
    @user-gh2rk4st4o Před 10 měsíci

    Rip off merchants 😂

  • @maxking3
    @maxking3 Před rokem

    This rewiring would be so much easier with KNX & DALI, but I guess nobody wants to pay the premium for digital electrics.

  • @QuentinStephens
    @QuentinStephens Před rokem

    What a pity your customer didn't have you run ethernet at the same time.

    • @hb4782
      @hb4782 Před rokem

      Have you not heard of wifi?

    • @QuentinStephens
      @QuentinStephens Před rokem

      @@hb4782 Yes. Wifi sucks compared with wired ethernet. Wifi has real bandwidth problems when multiple people are using it. Wifi has real problems with certain types of walls. Signal attenuation is a thing with wifi but not with wired - as long as you are within spec. Wifi has real problems with security. Random passers-by cannot hack a wired ethernet link. And get back to me when wifi can do 10 Gbps and 25 Gbps.

  • @rogerbean393
    @rogerbean393 Před rokem

    Painful to watch ! All that dust and no masks , glad it’s your lungs !

  • @tc6907
    @tc6907 Před rokem

    Switch with lots of cables here…. 5 😂😂