  • In this video I visit a customer who had no heat. I found a low voltage fuse blown, plus multiple other problems. #hvac #hvactechnician #fieldpiece #hvacguy #hvaclife #hvactech #acrepair #hvacinstall #milwaukeetools #rheem
    Merch Store : hvac-guy-2.creator-spring.com
    HVAC LIFE FB Group: / 521086622906115
    Here are links to the tools I use, And it costs you nothing extra to buy from this list:
    Inficon D-Tek Stratus: amzn.to/3RvnXOl
    Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
    Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
    Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
    Fildpiece SVG3 Vacuum Gauge: amzn.to/3udursu
    Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
    Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
    Fieldpiece Blutooth Scale: amzn.to/3Gzveab
    Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
    Fieldpiece MR45 Recovery Machine: amzn.to/3cUFX5h
    Fieldpiece 8CFM VP87 Vacuum Pump: amzn.to/3qC2wA2
    Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
    Milwaukee M12 Impact Driver: amzn.to/37xXkqk
    Makita XDT16: amzn.to/3riXuaJ
    Makita 18V Light: amzn.to/3Fw4GW4
    Makita Wet/Dry Vacuum : amzn.to/3tw4dAL
    Makita 18V Battery Mounts in Van : amzn.to/3GxpVID
    Makita Jobsite Radio: amzn.to/3HuVp2u
    DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
    Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
    Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
    Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
    Klein Knee Pad: amzn.to/3cy6FB0
    Klein 7in1 Flip Socket: amzn.to/3bpabwG
    Klein Journeyman Pliers: amzn.to/3tvB60w
    Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
    Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
    Milwaukee Tool Box: amzn.to/322iyK9
    Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
    Milwaukee Hook Blade Knife: amzn.to/33F3m5T
    Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
    Western Nitrogen Regulator: amzn.to/3rmdKrx
    Klein Canvas Bucket: amzn.to/3FyzKVf
    Flag Velcro Patch Kit: amzn.to/3K8Eswx
    Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
    Milwaukee Magnetic Light: amzn.to/3FulCfF
    Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
    SS2 Float Switch: amzn.to/3K7LJMW
    3-Amp Breaker: amzn.to/3nxaSXJ
    Appion Valve Core Removal Tool: amzn.to/33CFArw
    Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
    Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
    Similar Small Tubing Bender: amzn.to/3fJsziJ
    Fluke Twist Guard Test Leads: amzn.to/3216R6j
    Fluke 975 Air Meter: amzn.to/3GwD9oM
    Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
    Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
    SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
    Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
    Quick Check Acid Test: amzn.to/3GA2XAy
    Aims Power Inverter: amzn.to/3qOSc87
    Wiha Torqe Screwdriver : amzn.to/3u1swH6
    Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
    American Flag Gator : amzn.to/3rKBl5u
    Compressor Tote: amzn.to/3H8xHst
    Inspection Mirror: amzn.to/3r9PERV
    Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
    1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Komentáře • 63

  • @mosesmom
    @mosesmom Před rokem +16

    An honest , smart HVAC tech is worth their weight in gold. A shout out to Kenny M. our HVAC hero, we love ya Kenny!

    • @aaronclark1599
      @aaronclark1599 Před rokem +2

      Curtis?

    • @johncspine2787
      @johncspine2787 Před rokem

      @@aaronclark1599 I think they’re referring to their very own good guy..

    • @sammyvalenzuela6263
      @sammyvalenzuela6263 Před rokem

      Way to go Kenny don't know you but , that's the what I love is being the hero when know one else could 😀

  • @rupe53
    @rupe53 Před rokem +4

    I had an intermittent issue years ago and it turned out the 2 4volts was low at the contactor, but only in the afternoon when the 245 volt dropped to 230 and change. Turns out they had run telephone wire to the t-stat and the #22 wire to the second floor was too small and causing the contactor to chatter... or drop out. It was 2 pair wire, so I doubled up the wires and the voltage came up enough to get rid of the issue. If I hadn't heard the relay chattering, I might still be there. This tells me there's a reason T-stat wire is generally #18.

  • @russellhltn1396
    @russellhltn1396 Před rokem +2

    Have you thought about using a 24V bulb instead of the circuit breaker? If you can find the right value, the bulb will be dark, the resistance is low, and most everything will have normal voltage. But if there's a lot of current, the bulb heat up, resistance will increase, and reduce the current. The maximum current is determined by the wattage of the bulb. It makes for a self-resetting "breaker" with a nice visual when the short is occurring. You can also use your clamp ammeter to see where the current is going on a "live" system.

  • @John-dp3ln
    @John-dp3ln Před rokem +3

    Nice job! Followed at least one hack on that one.

  • @jamesdaakron4790
    @jamesdaakron4790 Před rokem +1

    I’m actually thinking about going into this at 51 years old.
    I took A/C and Refrigeration in High School before going into the USAF and being a F-16 Crew Chief 91-95. I built Boeing Landing gear until 9-11. Owned a construction business for 15 years and now I’m bored in Florida.

  • @jackl9922
    @jackl9922 Před rokem +5

    In my area, I have not been able to find a good person. Everyone wants to condemn stuff. After 2nd expensive change out 3yrs ago, started on CZcams and internet to learn for myself. Most things I can diagnose and fix myself now. I won’t mess with gas lines or coolant. Then call the high price company. It’s actually quite easy to open a condenser and clean the coils. I did it two weeks ago, and unit runs much less. I greatly appreciate learning how things work. Electrical no issue, I’m trained on that.

  • @sammyvalenzuela6263
    @sammyvalenzuela6263 Před rokem

    I have learned so much from this guy I feel like my game went up a notch , thank you for the knowledge. Will be a long time follower 🥶

  • @stephenbullock1443
    @stephenbullock1443 Před rokem +1

    That's my favorite thing to do.it's good challenge fixing it right

  • @GPSJayDog22
    @GPSJayDog22 Před rokem

    Good man. Reconnecting the lockouts when ya didn't have to.

  • @toolchuck
    @toolchuck Před rokem +2

    I enjoy watching you work through problems, almost as much as I enjoy my new "Women Call Me When They Get Hot" mug that I got today!
    Thank you and All the Best, Chuck

  • @1975original
    @1975original Před rokem +3

    I like that motorcycle in the background ;) Great video.

  • @jamesringler5977
    @jamesringler5977 Před rokem +4

    I’ve been working in temp. Control for over 40 yrs designing, installing, and wiring and 99% of the time the common of the low voltage transformer is grounded to prevent floating commons

  • @jackl9922
    @jackl9922 Před rokem +1

    Glad you go beyond simple fix and go.

  • @AMStationEngineer
    @AMStationEngineer Před rokem +2

    №1: Your level of troubleshooting discpline is high enough, that you really should consider expanding your horizons into electronics at the component level.
    №2: Many thanks for introducing me to 'Kaiweets' test gear, and tools. I purchased their 'Smart' Digital Multimeter, and self-adjusting wire stripper, and am quite pleased with both.

  • @jamesfitzsimmons381
    @jamesfitzsimmons381 Před rokem +2

    Good job. You make looking for 24 volt short/ ground look easy

  • @orionwarren4244
    @orionwarren4244 Před rokem +2

    That yard looks like the neighborhood 'toy' store!🤣

  • @MrMultitool
    @MrMultitool Před rokem +1

    Get you a short pro tool Lil poppers are ok but I really like my short pro. Good job.

  • @sknight0391
    @sknight0391 Před rokem +7

    Way to hang with it! 😎👍
    Might be about time for a new set of test leads. Those seem to be acting a little wonky.

    • @B_HVAC
      @B_HVAC Před rokem

      Ol’ Shannon, good to see you’re still around man.

    • @Bryan-Hensley
      @Bryan-Hensley Před rokem +1

      I got lit up with some worn meter leads.

  • @johnwalker890
    @johnwalker890 Před rokem +1

    Good job Curtis.

  • @Michael-on4ti
    @Michael-on4ti Před rokem +1

    Watching old Curtis and drinking canadian beer.

  • @Paulie1232
    @Paulie1232 Před rokem +4

    Wiring issues are such a pain in the ass, good job...

  • @clayevans3421
    @clayevans3421 Před rokem

    Soon as they start getting the hurricane damage repaired there will be a huge demand for ac installers

  • @rciancia
    @rciancia Před rokem +1

    I really enjoy your videos.. thank you ... I am learning alot by watching

  • @chuckstillwell9549
    @chuckstillwell9549 Před rokem +1

    Good catch

  • @baeruuttehei1393
    @baeruuttehei1393 Před rokem

    Seeing most of the installations you're working on I have to say to be happy to live overhere in Europe where rules are apparently much stricter on ACs and heaters. Truly and honestly: most of the equipment you're called to work on are terrible on wiring! Incomprehensible for an overseas person. Anyways, keep up the good work in holding your customers safe! Good luck! Ciao, says T🐻 from the NLs.

    • @captain3xtreme
      @captain3xtreme Před 3 měsíci

      I feel the same way as someone who works in industrial machinery, I can't help but feel everything in the residential HVAC industry is just made as cheaply as humanly possible, everything is spade connectors, no terminal strips, no wire numbers, you're lucky if they install zip ties at the factory, they treat stainless steel like it's gold, wont even use it on areas that they know will corrode like heat shields on gas furnaces.

  • @lancelawrence3259
    @lancelawrence3259 Před rokem +1

    Nice work

  • @joehead1294
    @joehead1294 Před rokem +1

    How about that receptacle mounted below the disconnect! At least it's 'out of the weather'. 💯

  • @kylegreene1583
    @kylegreene1583 Před rokem +2

    I can imagine the owner going outside to wiggle the wires and the "trick" didn't work any more😂😂

  • @leoaz4667
    @leoaz4667 Před rokem +1

    Nice bike in the background not sure I would leave mine a grass

    • @pheuker45322
      @pheuker45322 Před rokem

      They had a little bit of everything there, but I doubt it all ran

  • @manonfire3642
    @manonfire3642 Před rokem

    Excellent electrical trouble-shooting.

  • @Bryan-Hensley
    @Bryan-Hensley Před rokem

    I'll give you a little hint if you are going to try to find shorts or low resistance with an ohm meter. Nothing on the low voltage side will be below 15 ohns and that's the reversing valve coil. Everything else will be higher than 15 ohms.. also use common for "ground" when checking this because some transformers are isolated from body ground

  • @billybrown1979
    @billybrown1979 Před rokem +1

    does the hvac move wires around to get another call for more money when they can fix it the first time. it will catch up with down the road. be bless and love.

  • @gtownhvac1640
    @gtownhvac1640 Před rokem +2

    What do you think of the new milwaukee m12 impact drill? I love mine very light. I recommend the boot protector

  • @chuckjohnson919
    @chuckjohnson919 Před rokem +1

    Talk them into a coil cleaning why you got that nasty thing open :)

  • @robertcouffer7908
    @robertcouffer7908 Před rokem +2

    Hacks !! There's Nothing Worse !!

  • @realSamAndrew
    @realSamAndrew Před rokem +2

    So what was causing the short?

  • @sammyvalenzuela6263
    @sammyvalenzuela6263 Před rokem

    Is fan going backwards my old eyes 👀😆

  • @bobbywenger5595
    @bobbywenger5595 Před rokem +1

    👍👍👍

  • @johncspine2787
    @johncspine2787 Před rokem

    Why did the fan start fast, then look like it slowed way down, and why is it looking like it’s backwards..isn’t it supposed to push air up and out in the direction heat normally flows, sucking cool air through the coil and then straight up?

  • @gtownhvac1640
    @gtownhvac1640 Před rokem +1

    Bro get the new USB Milwaukee light. I'm 100% sure what will you like

    • @HVACGUY
      @HVACGUY  Před rokem +1

      I’ve had the AA battery version, and I keep losing them. I’ve had three already

  • @mrgreen9086
    @mrgreen9086 Před rokem +1

    Could I use one of those poppers in place of a 5amp fuse?

    • @HVACGUY
      @HVACGUY  Před rokem +1

      Yes, they come in three and five amp varieties, and can be permanently mounted

  • @DelticEngine
    @DelticEngine Před rokem

    Can't help but feel sorry for that outdoor unit being mutilated like that and left in that condition.

  • @dinarevollo8468
    @dinarevollo8468 Před rokem

    Hold on, you just jumped 24V. to common. Ofcourse is going to to trip! Get a volt meter and isolite the load.

  • @jamesfitzsimmons381
    @jamesfitzsimmons381 Před rokem +1

    Where did you finally find the shirt at?

    • @HVACGUY
      @HVACGUY  Před rokem +1

      Tstat wire touching outdoor panel

  • @thepoopsoup
    @thepoopsoup Před rokem +1

    What a mess!

  • @ricardogierbolini2682

    I was expecting he would have cleaned up the condenser coil..was terrible

  • @DisEnchantedPersons
    @DisEnchantedPersons Před rokem

    I've seen the very insulation fall off of wiring before.

    • @johncspine2787
      @johncspine2787 Před rokem

      I just had an attic fire, I see more lights with 50’s wiring that have cracked insulation w bare copper exposed..I’m getting it all retired even though the insurance won’t pay..new panels, new service up to 200amps, whole shebang...I can’t see sealing all the ceilings back up (they gutted them to remove smoky insulation) with suspect cloth wrapped Paraflex just waiting to start another fire..