How to Operate & set Parameter (Chipconveyor Inverter type)

Sdílet
Vložit
  • čas přidán 22. 11. 2022
  • 1. Manual Operation by Inverter
    (Machine Ready , Door close, does not matter mode)
    2. How to set parameter
    (navigate button, Up & down)
    3. Manual operation by button
    (Machine Ready , Door close, does not matter mode, middle position on inverter)
    4. Auto operation by M-code
    (M24/ M25 = Chip conveyor start / stop , M52/M53 = door close / open )
    ******* Standard Parameters *******
    P-01 H 70.0 Maximum Frequency / Speed Limit
    P-02 H 40.0 Minimum Frequency / Speed Limit
    P-03 2.5 Acceleration Ramp Time
    P-04 0.00 Deceleration Ramp Time
    P-05 0 Stop Mode Select
    P-06 0 Energy Optimiser
    P-07 220 Motor Rated Voltage
    P-08 A 0.8 Motor Rated Current
    P-09 H 60 Motor Rated Frequency
    P-10 0 Motor Rated Speed
    P-11 3.0 Torque Boost
    P-12 0 Primary Command Source
    P-13 0 Industrial / Fan-Pump Control Mode
    P-14 100 (201) Extended Menu Access Code
    ******* Extended Parameters *******
    P-15 7 Digital Inputs Function Select
    P-16 In-Pot Analog Input 1 Format
    P-17 8 Effective Switching Frequency
    P-18 1 User Relay Output Function Select
    P-19 100.0 Relay Threshold Level
    P-20 H 5.0 Preset / Jog Frequency / Speed 1
    P-21 H 25.0 Preset / Jog Frequency / Speed 2
    P-22 H 40.0 Preset / Jog Frequency / Speed 3
    P-23 H 60.0 Preset / Jog Frequency / Speed 4
    P-24 0.00 2nd Ramp Time (Fast Stop)
    P-25 8 Analog Output Function Select
    P-26 H 0.0 Skip Frequency Hysteresis Band
    P-27 H 0.0 Skip Frequency Centre Point
    P-28 0 V/F Characteristic Adjustment Voltage
    P-29 H 0.0 V/F Characteristic Adjustment Frequency
    P-30 EdgE-r Terminal Mode Restart Function
    n.c Fire Mode Input Logic
    OFF Fire Mode Input Latch
    P-31 1 Keypad / Modbus Mode Restart Function
    P-32 0.0 DC Injection Duration
    1 DC Injection Braking Mode
    P-33 0 Spin Start Enable
    P-34 0 Brake Chopper Enable
    P-35 100.0 Analog Input 1 Scaling
    P-36 Adr 1 Drive Address
    115.2 Modbus / CANbus baudrate
    t 3000 Communications Trip Delay
    P-37 101 Extended Menu Access Code Definition
    P-38 0 Parameter Access Lock
    P-39 0.0 Analog Input 1 Offset
    P-40 0.000 Display Speed Scaling Factor
    1 Display Scaling Source
    P-41 1.0 User PI Proportional Gain
    P-42 1.0 User PI Integral Time Constant
    P-43 0 User PI Operating Mode
    P-44 0 User PI Reference Select
    P-45 0.0 User PI Digital Reference (Setpoint)
    P-46 0 User PI Feedback Select
    P-47 U 0-10 Analog Input 2 Format
    P-48 0 'Standby' Activation Delay Time
    P-49 5.0 PI Wake Up Error Level
    P-50 0.0 User Relay Output Hysteresis
    ******* Advanced Parameters *******
    P-51 0 Motor Control Mode
    P-52 1 Motor Parameter Auto-tune (1로 설정 Autoset후 0으로 자동 변경)
    P-53 50.0 Vector Mode Speed Controller Gain
    P-54 150 Maximum Current Limit
    P-55 Autoset Motor Stator Resistance
    P-56 380 Motor Stator d-axis Inductance (Lsd)
    P-57 38 Motor Stator q-axis Inductance (Lsq)
    P-58 H 0.0 DC Injection Speed
    P-59 20.0 DC Injection Current
    P-60 r 1 Thermal Overload Retention
    o 0 Thermal Overload Management
    P-61 0 Ethernet Service Option
    P-62 0 Ethernet Service Timeout
    P-63 0 Modbus Mode Selection
    P-64 2 IP66 DI1 Source
    P-65 0 IP66 DI2 Source