How to create Petroleum Assay for the mixture of Light, Medium and Heavy Crude Oil in HYSYS

Sdílet
Vložit
  • čas přidán 11. 09. 2024

Komentáře • 18

  • @thisisbismay5681
    @thisisbismay5681 Před 2 lety

    Ma sha Allah good effort

  • @naturegeography5884
    @naturegeography5884 Před rokem

    Great work 👏

  • @princeejim
    @princeejim Před 4 měsíci

    Thank you for this informative video. What happens to the saline water which should be ejected from the desalter? From your flowsheet, it seems that the saline water is sent with the wet warm crude to the heater and onwards to the distillation column.

  • @AroojFatima-zz2yr
    @AroojFatima-zz2yr Před 2 lety

    Nice well done 👍🏻

  • @honnguyen3251
    @honnguyen3251 Před 2 lety

    Thanks a lot for many your helpful guided videos

  • @sw-qn1ky
    @sw-qn1ky Před rokem

    Thank you for kind lecture.

  • @m_khan_999
    @m_khan_999 Před rokem

    While installing oil its showing one or more oil cannot be installed due to missing names. Can you plz solve this issue

  • @atyhay
    @atyhay Před 2 lety

    Бас алға!

  • @avilovsky8369
    @avilovsky8369 Před 2 lety +1

    I used aspen v8.8 and did everything step by step according to the video, yet for some reason message board keeps saying that sulfur-1,2,3 were not defined for mix oil and that there was an error calculating hypothetical component NBP[0]1021. Could you hint me what might be the problem?

  • @ftouhaahmed5470
    @ftouhaahmed5470 Před 2 lety +2

    Please msr just a question
    What is the use of Mix in this process?

    • @eduXinsight
      @eduXinsight  Před 2 lety +1

      Every refinery is designed to process crude oil at certain properties , which sometimes achieved by blending of more than one different crude oil.

  • @ftouhaahmed5470
    @ftouhaahmed5470 Před 2 lety

    Thanks bro

  • @vig_Indomitable
    @vig_Indomitable Před 2 lety

    Hi Mr, Can you please enlighten me about the purpose of mixing water initially?
    If we need to desalt don't we need to add 3 phase seperator?
    Also please tell me how to estimate number of trays required for crude distillation.

  • @avilovsky8369
    @avilovsky8369 Před 2 lety

    When calculating assay, in message board it says "All assay values equal to or greater than 90,00 result in calculated TBP temperatures exceeding maximum of 1100°C [2012°F]. Resulting critical and physical properties could be erroneuos. Please check your assay data. Assay is still calculated. Should this message just be ignored sir?

  • @naturegeography5884
    @naturegeography5884 Před rokem

    Where do you come from the data about the furnace?

  • @nanayyaw622
    @nanayyaw622 Před 2 lety

    What's the difference between Petroleum Assay and Oil Manager?

  • @cypher8689
    @cypher8689 Před 2 lety

    hi mr.
    can i have your datasheet? Imean your excel file you used in this video.

  • @hassaanahmedkhan5854
    @hassaanahmedkhan5854 Před 2 lety

    Can i get excel file?