  • Every home is different and sometimes getting your radon down as far as possible takes a little extra elbow grease.
    00:00 Intro
    01:41 Initial Suction Point
    04:42 Initial Mitigation Results
    06:18 Identifying and Adding Suction Points
    08:31 Results of Adding Additional Suction Points
    Ecosense Radon Monitors: Use promo code ARM to receive a discount ecosense.io/ARM
    If you have a mitigation system, test your home for radon every 2 years.
    How to set up Air Chek test kit • Setting Up Air Chek Ra...
    How to set up Alpha Track test kit • Accustar Alpha Track L... .
    Get an Estimate (within an hour of the Twin Cities, MN metro area.) americanradonmitigation.com/f...
    or call 612-474-1004
    If you live outside our service area, check out our virtual consulting services at americanradonmitigation.com/c...
    For basic questions, leave a comment, and we'll try to answer when we have the chance.
    Thank you so much for watching!
    Frequently used products. If you purchase from the links below, we earn a commission.
    Ecosense Radon Monitors: Use promo code ARM to receive a discount ecosense.io/ARM
    Fantech Radon Fans. Promo code JESSE to get 5% off your first order. radonpds.com/product-category...
    TEC DG-8: store.energyconservatory.com/...
    TEC Fog Puffer: store.energyconservatory.com/...
    Radon Sealant - amzn.to/2Mu6yZv
    Milwaukee Super Hawg Drill - amzn.to/32m67sk
    Milwaukee 16’ Autolock Tape Measure - amzn.to/3ouZFXQ
    Bosch 5-Inch Core Bit - amzn.to/36ik4Xw

Komentáře • 58

  • @MattBrouse
    @MattBrouse Před rokem +5

    I like the candor that the usual work didn't quite suffice, but a few simple follow-ups got the job done. Great information!

    • @nonasmith2405
      @nonasmith2405 Před rokem

      This sealing of the basement maybe a partial fix temporarily but it's import to put your type of radon mitigation system in as well radon is dangerous

  • @user-tf2on7we9z
    @user-tf2on7we9z Před rokem +1

    Thanks Jessie for all your effort in keeping this channel going!
    I really enjoy all of your uploads! Super clear and to the point, also very interesting to watch!
    Best of luck to you Sir!

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před rokem

      Thank you for the encouragement, Ryan! It takes so much time and energy to shoot and edit these videos. I'm glad you enjoy watching.

  • @Ch00chCharlie
    @Ch00chCharlie Před rokem

    I am all about this!
    Today we found that the present system installed by others was pulling radon into the home through the slab supply ducts, through the furnace, and located with an Ecotracker pouring out of the return duct in the ceiling...

  • @Tenpennycustoms4958
    @Tenpennycustoms4958 Před rokem

    Great video as always. When do you stitch underneath or go overhead with another suction point?

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před rokem +1

      Thanks, Logan. It's almost always easier to add multiple suction points rather than employ the stitching method. We primarily only stitch when a finished basement prohibits multiple suction points. Check out this video for an example of that. czcams.com/video/TyCUneMCcLc/video.html

  • @superbenis09
    @superbenis09 Před rokem

    Your videos are super awesome to watch as a mitigator myself, licensed and certified out of Colorado. Where are you based? Also, is that 2 inch schedule 40 pvc you're using??\

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před rokem +1

      Thanks, Gage! We are in Minnesooota don't ya know. 😉
      What part of Colorado are you located in?
      It sure is 2-inch piping. It comes in handy as there are many places that a 3-inch pipe will not fit. Chad Robinson even talks of using smaller piping. As long as you understand your piping resistance, you can use small pipe in many low-flow applications. Check out Kansas Stare Universities OMAD course to learn more. Here’s a video about it. czcams.com/video/jyX5zmTg0QE/video.html

  • @geraldgigon5488
    @geraldgigon5488 Před rokem

    Great Channel, We are finishing the basement for a movie room and the radon level was around a 3.5 to 4.5 before sealing the cracks in the floor and the bottom of all the walls with radon sealer. I have a poured concrete walls that have spray foam from top to bottom for insulation. Now the radon level is above 8/9. what am I doing wrong, I thought sealing it would reduce the readings. I will be putting in a Radon fan system next. thanks

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před rokem

      Hey Gerald. I have heard the EPA has done studies and found that sealing alone is not an effective way to reduce radon significantly. I would say you are well on your way to having an incredibly effective and energy-efficient radon mitigation system. Feel free to contact us for advice via virtual consulting or to rent a mitigation tool kit. Good luck with the project! americanradonmitigation.com/shop/

  • @DM-qe1dr
    @DM-qe1dr Před 6 měsíci

    Great video sir! How often do you recommend testing for a home that already has a system in place? (We had a system installed 12 years ago, then never retested and now 12 years later tested and found 4.4 - not good!)

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 6 měsíci

      Thank you! The EPA recommends testing every two years if you have a radon mitigation system. A radon monitor is also a great product to consider.

  • @nonasmith2405
    @nonasmith2405 Před rokem

    We were getting a radon reading super high in our house and we were doing our own sort of mitigation till we could figure out about sealing our basement and Chyna died here we're getting an over 200 reading for the radon we we had to have our basement sealed outside filled cracks and the weeping tiles replaced on three side of the basement on the outside now our radon levels are under 10 Bq/m3

  • @user-il1zg9ty5z
    @user-il1zg9ty5z Před 10 měsíci

    I've watched your videos and greatly appreciate all your input. However, I do have a question unrelated to this video related to an excavation process I use for subslab depressurization.

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 10 měsíci

      Thank you. What’s your question?

    • @user-il1zg9ty5z
      @user-il1zg9ty5z Před 10 měsíci

      @@AmericanRadonMitigation the region I work in New Mexico has very thick caliche and I use a pressure washer to loosen and remove material. However, it seems like my acclimation time increases in some cases. I was wondering if this medical of removing material has been used out your way and it's effectiveness

    • @user-il1zg9ty5z
      @user-il1zg9ty5z Před 10 měsíci

      I'd like to add that this install is an outside install where a 5" core is done through the stem wall below the slab. The material under the structure is clay so I chase plumbing to try to keep to one system. I have found what I think to be a safe way to remove material like hard clay using a pressure washer and shop vac. I believe this process increases the acclimation time. Thoughts?

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 10 měsíci

      @@user-il1zg9ty5z what do you mean by acclimation time?

    • @user-il1zg9ty5z
      @user-il1zg9ty5z Před 10 měsíci

      @AmericanRadonMitigationAnoka a downward trend in radon over time as the pit of suction dries out. I'm trying to find a way to provide an 'ultimate mitigation' in which the client can test every 2 years with successful results.

  • @wegeo
    @wegeo Před 9 měsíci

    Hi Jessie, When having multiple suction points it is better to put the gate valve at the suction point or near the T that is closer to the fan? It would seem adding near the T might lower the suction pressure along the other suction point pipe run, but I am not sure which is better. Thanks for any insight you might have.

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 9 měsíci +1

      I don't think it matters where you add the valve. However, I would add it below the U-tube manometer and alarm. Otherwise, the manometer may look even on both sides, and the alarm may not have enough static pressure to work.

    • @wegeo
      @wegeo Před 9 měsíci

      Thanks for your input I appreciate it@@AmericanRadonMitigation

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 9 měsíci

      You bet!

  • @rhodeislandfirearmsownersl9916

    Hi Jessie, I've been watching all your videos so I have an idea of what to ask my installer. Question for you. We have a basement bathroom with a sewage discharge basin and was wondering if that could be a point of entry for Radon. It should be airtight but I was thinking the PCV waste pipe coming into the tank from the toilet might not be sealed? I have high levels in my basement.

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 7 měsíci

      You can always pop the cover off and check it out. Sometimes, they have a rubber grommet around the sub-slab piping as it comes into the basin, and sometimes, it's a rough upending that can be sealed to make it more airtight.

    • @rhodeislandfirearmsownersl9916
      @rhodeislandfirearmsownersl9916 Před 7 měsíci

      @@AmericanRadonMitigation Sounds like a cr$#py job! I'll give it a shot tomorrow.

  • @donluchitti
    @donluchitti Před 3 měsíci

    Been binging your content. Brooklyn Center MN resident here and a basement dweller. Just found out I’ve been breathing radon for the last 22 years at 3 pci/L . Basement bedroom too. We’re gonna call you up . Do you have any resources or anecdotal opinions based on your experience about someone’s overall risk with my amount of exposure?

    • @marcusbiller867
      @marcusbiller867 Před 3 měsíci

      3 is considered within spec in a lot of countries...I wouldn't worry that much.

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 3 měsíci

      You can check out this information on the MN MDH site: www.health.state.mn.us/communities/environment/air/radon/index.html

  • @IconStature
    @IconStature Před rokem

    We just noticed my radon system wasn’t running and after investigating it I realized that the GFCI outlet that it’s always been plugged into now trips every time I plug the radon system into it. Could this be a fan issue or something in the electrical wiring of the radon system causing this issue? The outlet seems to do fine with anything else plugged in. I even tried the radon system on another GFCI outlet and it tripped it as well. Any help would be greatly appreciated thank you

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před rokem +1

      I'm no electrician, but it sounds like it might be time for a new radon fan, especially if the fan was working before the tripping issue.

  • @IthacaDon
    @IthacaDon Před 5 měsíci

    Any experience with ERV systems and radon mitigation?

  • @menacexp
    @menacexp Před 9 měsíci

    How would you put in a mitigation system in a finished home?

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 9 měsíci

      Check out our other videos to see how we mitigate finished homes. czcams.com/play/PLuNbsvWsW0-BAlE7A5ufGroZRZUS3_T2d.html&si=16Uq9uRYsaRET2y-

  • @chucksauder1564
    @chucksauder1564 Před rokem

    You mention in other videos that you don't use rain caps, but don't mention this version. RadonAway Fan Pipe Cap with Screen for 4" PVC. This is what I had on my old house Radon system. How do these do?

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před rokem

      Hey Chuck, check out what the standards say about rain caps. Also, check the next page for more on rain caps and icing. standards.aarst.org/SGM-SF-2017-1220/26/index.html
      Clearances and icing are the two primary considerations before adding a rain cap.
      We have never used one.

    • @chucksauder1564
      @chucksauder1564 Před rokem

      @@AmericanRadonMitigation Thank you. Was just curious as I am installing a system in my "new to me" home. Your videos are a wealth of knowledge. Keep up the great work.

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před rokem

      @@chucksauder1564 thank you, Chuck!

  • @alexbudd8770
    @alexbudd8770 Před rokem

    How would you go about pricing a job like this? Seems to be so many unknowns

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 11 měsíci

      Our estimates have a starting base price. Think of this as a price for the best case scenario where we just need one suction point and the system has no fancy bells and whistles. Next, we add optional line items like additional suction points, sealing, alarms, etc. We like to plan for the worst and hope for the best. We then make data-driven decisions based on our pressure field extension numbers and radon levels to make recommendations to the homeowner.
      Using Jobber to create estimates allows us to mark line items as required, optional, or recommended.
      Check out Jobber here: share.getjobber.com/mzkvPGD

    • @alexbudd8770
      @alexbudd8770 Před 11 měsíci

      @@AmericanRadonMitigation thanks so much for the reply! Love how much detail you put in each video, keep it up!

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 11 měsíci

      You bet, Alex! Thank you for commenting!

  • @johnwhite2576
    @johnwhite2576 Před 9 měsíci

    Why are you using 3 vs 4 inch pipe ??

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 9 měsíci

      We calculate the CFM needed to achieve the desired pressure field extension to determine pipe size.

  • @AnthonyCelata
    @AnthonyCelata Před 8 měsíci

    You must get a lot of exposure doing all these jobs.

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 8 měsíci

      Sometimes, I try to vent the home when I'm not doing PFE measurements. The radon is typically lower on the second or third day of an installation since we usually have part of the system running by the end of the first day.

    • @AnthonyCelata
      @AnthonyCelata Před 8 měsíci

      @@AmericanRadonMitigation Man you should try and get on The Build Show! You're just the kind of expert installer they look to promote! Your work is impeccable! Keep making videos!

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 8 měsíci

      Thanks, Anthony! How would one go about that?@@AnthonyCelata

    • @AnthonyCelata
      @AnthonyCelata Před 8 měsíci

      @@AmericanRadonMitigation I'm not sure if you're familiar with Matt Risinger but he has a big CZcams following and I would say he's among the top dogs in the CZcams construction genre of content. I've never tried to get noticed by a large channel like his before, but I am as of this year a Congressional candidate here in Massachusetts and lately I find myself trying to get everyone's attention! So I would suggest becoming active in his community as well as looking through his site for contact information. He only has (from what I've been able to find) two videos covering radon. Being in the trades my whole life as an electrician I certainly know how to spot a guy who takes his work seriously and that my friend is you. I think with some persistence you might be able to get a foot in the door. I'm sure the attention it could bring to our company would be worth the bother. As a side note, I feel like your skills would transition very well to sealing a building envelope of leaks, yeah know, getting rid of the draft, keeping the cold out or the heat in, bringing in ventilated air on your terms. Watch a few Build Show episodes and I think you'll get the picture. Its what Matt constantly preaches and I happen to be in agreement with him on the topic. When you have a house that's leaky and gets an average Air Change per Hour (ACH) rating of 1.5! Meaning 1.5 times an hour the volume of air in the house is changed, you're just throwing money out the window. Maybe you can spin that in your favor some how. If you ever end up getting a contact with the guy let us know, best of luck to you!

  • @dwaynejohnson6277
    @dwaynejohnson6277 Před 7 měsíci

    The front step must not have been vented. If there was a vent on each side providing good cross-flow I imagine you would not have had this problem

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 7 měsíci

      Is it common to have vented front steps in your area?

    • @dwaynejohnson6277
      @dwaynejohnson6277 Před 7 měsíci

      Wow. That was a quick response. Most front steps here in Ontario Canada have full-height foundation walls and a doorway into them from the basement so they can be used as a fruit cellar or wine cellar. And yes, must be cross-vented by code. The learning in this case would be that if there is hollow unvented space under porch, warn the owner that it msy need to be treated also, and measure the levels there before the system is designed.. live and learn. Thanks for the videos. Learning lots.

    • @AmericanRadonMitigation
      @AmericanRadonMitigation  Před 7 měsíci

      That's interesting. Unfortunately, there's no easy way to measure the radon under the front step here in Minnesota since it's inaccessible. You'd have to drill a hole to measure the radon with a radon sniffer.