How to calibrate diameters, rebuild graph and check AD value for diameter position. Waratah 622B

Sdílet
Vložit
  • čas přidán 29. 08. 2023
  • Make sure that the max open is 30.8 and the max close is 3.8 or 3.7 before calibration of logs.
    Take three points of measurements on the log. In an X pattern and straight up and down. Average the 3.
    The displayed number is the number on your computer. The measured is the number from the taking three points.
    Ensure you open and close feed rollers and zero saw before moving onto your next piece.
    DO NOT CALIBRATE BUTT FLARE!!
  • Hry

Komentáře • 4

  • @hunterrossi4584
    @hunterrossi4584 Před 20 dny

    You helped me tons man! Me and my mechanic thank you lol. Not too many videos on the older program

  • @jamesbakken6052
    @jamesbakken6052 Před 9 měsíci +1

    Buddy you are a lifesaver, just started on a processor and this is exactly what I was looking for. Thanks for the vid

    • @ReaperofTrees
      @ReaperofTrees  Před 9 měsíci

      Any time!! Been trying to get a few more computer tips up but there never seems to be enough time lmao

  • @rogerm1205
    @rogerm1205 Před 10 měsíci +1

    Promo sm 👍