  • @ahmetuludas9328
    @ahmetuludas9328 Před 9 měsíci

    İm gonna use 12 volt 90 lt fridge in caravan. Which gas should i use?

  • @lovemorejenami2196
    @lovemorejenami2196 Před rokem

    Nice work bro

  • @yusifsuleiman5502
    @yusifsuleiman5502 Před 7 měsíci +2

    Please I have a question 🙋‍♂️
    Why my cheese freezer only has halfway freezing.
    Thanks 🙏

    • @CSTChillingSolutionsTraining
      @CSTChillingSolutionsTraining  Před 6 měsíci

      The half of the evaporator or the half of the unit? It could be a lack of refrigerant gas or an obstruction in the capillary. In this case, the capillary should be very cold. Another possibility is a fan failure, causing a lack of air circulation. Here's what you can do: grab an amperometric clamp and measure the current consumption. Turn off the unit and let it stand for an hour. Then, turn it back on and measure the electric consumption after a few minutes. Compare it with the RLA (Rated Load Amps). If it lacks gas, the reading will be significantly below.

    • @tuvoca825
      @tuvoca825 Před 5 měsíci

      Change the settings
      Check the airflow
      Make sure the thermostat is good
      Charging the refrigerant is the last option if anything else you can think of. If you have to charge it... there is a leak. Flammable leaks are not good... explosion risk.

    • @sylvesteresezobor2755
      @sylvesteresezobor2755 Před 4 měsíci

      please I have similar problems. how did you solve the problem?

    • @yusifsuleiman5502
      @yusifsuleiman5502 Před 4 měsíci

      @@sylvesteresezobor2755 still working for the solution. One technician promised to fix it by weekend.

    • @yusifsuleiman5502
      @yusifsuleiman5502 Před 4 měsíci

      @@sylvesteresezobor2755 I have good news, my freezer has just been fixed now. I figured a leakage near the dryer filter and when trying to fix the leakage, we realized the new dryer filter we installed previously is faulty. I have to change new one and make sure the leakage is addressed.
      The freezer is now working for like 2hours and the cooling is coming up ⬆️

  • @kareemhameed4042
    @kareemhameed4042 Před rokem +1

    I was told R600a can only be charged in liquid. How true is that?

  • @a807511
    @a807511 Před 6 měsíci +2

    600 is dangerous as h*ll and should be banned.

    • @CSTChillingSolutionsTraining
      @CSTChillingSolutionsTraining  Před 6 měsíci +1

      Therefore, R600a is used in lower-capacity equipment; in this way, the flammability is compensated by using a small amount of R600a.

    • @hipihei
      @hipihei Před 4 měsíci +2

      I've worked with r600a fridges for 15 years but never had any problem with them. My fridges and freezers are r600a model and i have no issue having them. However..it's not ment to break rules and work ethics and practices with r600a..😮

    • @mikafoxx2717
      @mikafoxx2717 Před měsícem

      ​@@hipiheiIt is hermetically sealed.. how often does your old freon leak out of your fridge even after 40 years? Unless your house is already on fire, which then your natural gas lines and stuff won't help either.