प्लांट में अमोनिया गैस कैसे चार्ज करें, how to charge liquid ammonia in the refrigeration plant

Sdílet
Vložit
  • čas přidán 5. 09. 2024
  • dosto is video me cold storage refrigeration plant me liquid ammonia kaise charge kiya jata hai iske baare me bataya gaya hai so dosto is video end tak jaroor dekhe, thanks.
    Hi,
    I am purushotam, Welcome to our youtube channel About cold storage in Hindi.
    My website link : techycool.blog...
    #aboutcoldstorageinhindi #hindi

Komentáře • 97

  • @MuhammadShafiq-dp1ov
    @MuhammadShafiq-dp1ov Před 3 měsíci

    Thanks sir

  • @AmanSingh-vh9nk
    @AmanSingh-vh9nk Před 4 lety

    Thanks sir Jo apne ya video banai

  • @zaibuddin8696
    @zaibuddin8696 Před 5 lety

    Shukriya sir ji bhot din se wait karra tha Mai yahi video ka shukriya 👍

  • @saimaabdullah8707
    @saimaabdullah8707 Před 2 lety

    Very good sir

  • @SURAJKSA
    @SURAJKSA Před 4 lety

    Awesome narration .....and also nice voice

  • @SujeetKumar-ow8iv
    @SujeetKumar-ow8iv Před 4 lety +1

    Liquid controller ke bare mein bhi video bnao

  • @mukulhossain2398
    @mukulhossain2398 Před 3 lety

    Super video

  • @RoyVlog-ko3mx
    @RoyVlog-ko3mx Před 5 měsíci

    ধন্যবাদ

  • @mohdmusaib7515
    @mohdmusaib7515 Před 4 lety +1

    PHE condenssor video baneya

  • @duetkingm211
    @duetkingm211 Před 7 měsíci

    पूरा सिस्टम में ऐमोनिया कितना कीलो चार्ज करना पड़ेगा? उसका केलकयुलेशन फोरमयूला पर ऐक वीडियो बनाईए।सर जी।

  • @aniquekhan9891
    @aniquekhan9891 Před 4 lety

    Nice video

  • @budhasinghchouhanb.bchouha9454

    Very good

  • @ravindrasaroji9824
    @ravindrasaroji9824 Před 3 lety

    Good👌👌👌👌👌👌👌👌

  • @ShaniKr95
    @ShaniKr95 Před rokem

    Sir 1 cylinder khali hone per kitana pressure increase hoga kg/ cm² me 130 TR ke liye

  • @ShravanKumarKuchera
    @ShravanKumarKuchera Před 5 lety +1

    Reciver ki gas kabhi waps cylinder me bharne ka kaam pad jaye to kaise bhara ja sakta hai

    • @AboutcoldstorageinHindi
      @AboutcoldstorageinHindi  Před 5 lety +1

      Agar receiver se cylinder me bharne ki jaroorat kabhi padegi to iska bhi video jaroor banaunga, thanks.

  • @Tarunkumar-ri4iv
    @Tarunkumar-ri4iv Před 5 lety

    Nice

  • @pakistan4100
    @pakistan4100 Před 5 lety

    hi
    make any video on general feasibility report except land.

  • @vijaynegi9550
    @vijaynegi9550 Před 5 lety

    Sir oil charging ka v video bnaye please

  • @sandipkumarbari3825
    @sandipkumarbari3825 Před 2 lety

    Sir brine plant me kcx31 compressor hai usko amonia charge karte hai to inter cooler s.v wal laga hai woh chalu rhta hai lakin lcvd s, v chillar on nhi rhta hai

  • @hiteshmodi2079
    @hiteshmodi2079 Před 5 měsíci

    Gas cilynder vala ka naam kya he

  • @Satish_Mishra_03
    @Satish_Mishra_03 Před 2 lety

    I can refill gas in receiver while machine should be running process .

  • @chandansagar8616
    @chandansagar8616 Před 2 lety

    Sir ammonia cylinder me kitne kg gas aati hai please batye

  • @pjgokul1421
    @pjgokul1421 Před 3 lety

    Ammonia refrigeration suction and discharge pressure

  • @222knd
    @222knd Před 5 lety

    How much pressure will be therein side of new ( before charging)ammonia cylinder

  • @asiksk8283
    @asiksk8283 Před 3 lety

    Muje ammonia ka
    1) stading pressure
    2) discharge pressure
    3) suction pressure
    Janna hai

  • @Rakeshyadav-9801
    @Rakeshyadav-9801 Před 5 měsíci

    Compressor on rahega

  • @Bhaibhai-ow3ol
    @Bhaibhai-ow3ol Před 3 lety

    Ice plant pe bhi isaahi charge kar sakte ho kya

  • @mrsubrajgaming5420
    @mrsubrajgaming5420 Před 3 lety

    Sir kc 2compressor chilling water water tank coil kitina inch Hona chahihai or kitina ton ka water tank Hona chahiyea water temperature hamara 4'C constant Hona chahiyea

  • @zaibuddin8696
    @zaibuddin8696 Před 5 lety

    Sir ji oil pump k bare me bhi information chahiye uski bhi servicing kaise karte hai bataiye plz thank you sir

  • @sahilahmed5234
    @sahilahmed5234 Před 5 lety

    Sir ammonia ice factory lagane k liye kon kon se
    Licence ya certificate ki jarurat hoti hai

  • @Beatswithharnidh585
    @Beatswithharnidh585 Před rokem

    Konsa cold hai

  • @ShaniKr95
    @ShaniKr95 Před rokem

    Sir,1= expension valve full open karte h kay gas charging ke time .
    2 = kitana valve open karna h charging ka ye comp. Ka L.P press. Dekhkar bharte h kay
    Sir plz reply 🙏

    • @AboutcoldstorageinHindi
      @AboutcoldstorageinHindi  Před rokem +1

      Agar aapka plant LPR system hai to aap direct low pressure receiver me gas charge kar sakte uske liye jitna suction pressure chal raha hai utna hi pressure par charge kar sakte kai, uske liye suction low karne ki jarurat nahi hai agar aapka plant bina lpr ka hai to expansion valve ko pura khol sakte hai aur suction pressure ko down bhi kar sakte hai. Thanks.

    • @ShaniKr95
      @ShaniKr95 Před rokem

      👉Sir LPR 2.5 Kg/cm² per h to kay 2.5 per gas charge Kar sakte h
      👉Sir Kal mane gas charge Kane ka plan tha aur gaya tha to phale running me gas 2.8 kg/cm² tha . Pump down liya to receiver me gas approx 80 % aa gaya fir gas charge nahi Kiya wapas plant start Kiya. Aur 1 hrs. Tak observation rakha aur press. Increase Hokar 4.3 hi gaya wo stable h
      To Sir evaporator me evopration proper nahi ho raha h kay . Ya cond. Approach bad gaya h desclenig ki jarurat h
      Sir Reply plz

    • @AboutcoldstorageinHindi
      @AboutcoldstorageinHindi  Před rokem

      Bilkul 2.5 kg /cm2 par change Kar sakte hai , high-pressure jyada ho to condenser clean kar sakte hai, agar main receiver me gas thik hai aur lpr ka pump load me aa raha hai to sab kuchh thik hai. Evaporation evaporator ke pressure par depend karta hai, thanks.

    • @ShaniKr95
      @ShaniKr95 Před rokem

      @@AboutcoldstorageinHindi thanks 😊 sir ji

  • @Movies__HUB_901
    @Movies__HUB_901 Před 4 lety

    Hi sir

  • @naveenkumar-kf1gh
    @naveenkumar-kf1gh Před 2 lety

    Sir while gas charging the compressor should be on or off..??

  • @salahuddinshaikh8145
    @salahuddinshaikh8145 Před 5 lety

    Discharge pressure badhne k reason

  • @randhirpatil6346
    @randhirpatil6346 Před rokem

    Safety use karo

  • @AfjalKhan-nh8hb
    @AfjalKhan-nh8hb Před 5 lety

    Suction Kitna rhna Chahiye gas charge krte time bhai

  • @naeemahmed8873
    @naeemahmed8873 Před 3 lety

    Bhai gas bharne ke baad waaps kaise aati... plz tell me

  • @pardeepkayat1835
    @pardeepkayat1835 Před 5 lety

    One more videos nis

  • @BrijeshYadav-us9gv
    @BrijeshYadav-us9gv Před 3 lety

    Sir aap to hous pipe ka air nhe nekale

  • @amarnathgupta9555
    @amarnathgupta9555 Před 3 lety

    Bhi sefty mai kaam karo

  • @sahebmukherjee3865
    @sahebmukherjee3865 Před 3 lety

    Ammonia gas ko bapas cylinder me Kyse lu

  • @kiritratnabhaijungijungi8970

    Sar dishchaj peressur barta he to kiya kiya jay bata ho sar

    • @AboutcoldstorageinHindi
      @AboutcoldstorageinHindi  Před 5 lety

      Iske baare me already ek video hai is channel par use aap dekh sakte hai, aap is video ko dekhe "how to reduce discharge pressure of the refrigeration plant.

  • @sandeepirlawat6204
    @sandeepirlawat6204 Před 5 lety

    सस्पेंशन वालों की गिलान कैसे भरें

  • @imransohail5446
    @imransohail5446 Před 4 lety

    Sir Mene gas charge Kia laken cylinder k khatam hune k waqt barf ni Aya cylinder pe

  • @govindpatel8998
    @govindpatel8998 Před 4 lety

    Gas charge ko chamber me chhodane ke bad kya kare

    • @AboutcoldstorageinHindi
      @AboutcoldstorageinHindi  Před 4 lety

      Gas charge karne baad liquid line ka main valve ko khol de aur jis tara normal plant chalta hai us tarah plant ko chalaye, thanks.

  • @dharmendrakiit
    @dharmendrakiit Před rokem

    Cylinder completely khada karne se thodi bahut gas aur aa jaati hai…. Aisa aapne kyun hi kiya sir

  • @aniquekhan9891
    @aniquekhan9891 Před 4 lety

    Sir section pressure kitna hoga

  • @govindpatel8998
    @govindpatel8998 Před 4 lety

    Oil charge kis tarah kiya jata hai

    • @AboutcoldstorageinHindi
      @AboutcoldstorageinHindi  Před 4 lety

      Oil charge karne ke baare me is channel par video hai, usko aap dekh sakte hai, thanks.

  • @raghunathsingh5295
    @raghunathsingh5295 Před 5 lety

    L p r me ammonia gesture charj

  • @sandeepirlawat6204
    @sandeepirlawat6204 Před 5 lety

    रिसीवर का लिक्विड बाल कैसे बदलें

    • @AboutcoldstorageinHindi
      @AboutcoldstorageinHindi  Před 5 lety

      लिक्विड वाल्व chang करने के बारे में और एक्सपैंशन वाल्व का ग्लैंड भरने के बारे में भी बताऊंगा, कृपया इंतेज़ार करे।

  • @imransohail5446
    @imransohail5446 Před 4 lety

    Our 240 kg charge Kia laken pata ni laga k gas kahan gai

    • @AboutcoldstorageinHindi
      @AboutcoldstorageinHindi  Před 4 lety +1

      Plant me gas kam hoga isliye pata nahi chal raha, aur receiver ke gauge glass me dikhai nahi de raha hoga, gauge glass ko check kare , thanks for watching.

    • @imransohail5446
      @imransohail5446 Před 4 lety

      @@AboutcoldstorageinHindi Bhai app apna whatzapp number se sakte h ?

  • @9673853532
    @9673853532 Před 5 lety

    सर kc2 कॉम्प्रेसर एक घंटा चलनेके बाद पहला पिस्टन अपने आप अनलोड हो जाता हैं । अॉईल प्रेशर तीन kg/cm² और सक्शन प्रेशर 1.5 kg/cm² रहता है ।दुसरा पिस्टन लोड पे रहता है। कॉम्प्रेसर बंद करने के बाद वापस लोड पे आता नहीं हैं ।क्या दिक्कत हो सकता है कृपया मार्गदर्शन करू। धन्यवाद।

    • @AboutcoldstorageinHindi
      @AboutcoldstorageinHindi  Před 5 lety +1

      सबसे पहले आप चेक करें कि आयल प्रेशर चलते चलते कम हो रहा है क्या, उसके बाद vld को रिपेयर कराएं और ccsv वाल्व को भी चेक करें, धन्यवाद।

    • @9673853532
      @9673853532 Před 5 lety

      @@AboutcoldstorageinHindi Sir, प्रोब्लम सॉल हो गयी। ऑईल पम्प के प्लेट को स्क्रॅच पडा था।प्लेट को ०.५ mm का प्लेन कट मारा।
      सर प्लीज आपका पर्सनल नंबर मिल सकता हैं क्या? धन्यवाद ।

    • @Sparshagarwal-bx4ob
      @Sparshagarwal-bx4ob Před 5 měsíci

      @@AboutcoldstorageinHindiyour contact number please

  • @manojn5259
    @manojn5259 Před 4 lety

    Main valve kholo

  • @AjayKumar-de8zr
    @AjayKumar-de8zr Před 2 lety

    अजय 📞

  • @akashbhattacharya7458
    @akashbhattacharya7458 Před 4 lety +1

    Ammonia per kg kitna price hoga 🕉

  • @SKomg-ni6ps
    @SKomg-ni6ps Před 5 lety

    चाज करते समय बोटेल खदा नहीं कर सकते

    • @ShravanKumarKuchera
      @ShravanKumarKuchera Před 5 lety

      अगर सिलिंडर खङा कर देंगें तो सिलिंडर पूरा खाली नही होगा।

    • @salahuddinshaikh8145
      @salahuddinshaikh8145 Před 5 lety

      What is reason of discharge increase

  • @kishorbhaiprajapati1340

    Please m.n

  • @KSArmy1ktarget
    @KSArmy1ktarget Před 2 lety

    गलत तरीके से गैस चार्ज की है

    • @nikkuuuu_12
      @nikkuuuu_12 Před 5 měsíci

      Sabka alag tarika hota hai bro Ab pure india bahut company hai To sab ke sab ek Jaise work thodi krte hai

  • @sardarahmed.k411
    @sardarahmed.k411 Před 4 lety

    Purushottam Sar ji receiver ammonia Kitna gas Rahana chahie cooling tower gas Kitna Rahana chahie please batayega sar ji 7702178680 my mobile number

  • @musaibrahim6118
    @musaibrahim6118 Před 8 měsíci

    aapka fan how boss. me ak noya operator Ho.kc4 ka liner fitting dekhiae na please please aapka WhatsApp number plz❤❤❤