Modified Proctor Test (AASHTO T-180 and ASTM D1557) in Urdu/Hindi with English Subtitles
Vložit
- čas přidán 13. 10. 2021
- Hello Guys! In this video lecture/demonstration I am going to demonstrate the complete procedure of Modified Proctor Test (AASHTO T-180, ASTM D-1557). The main objective of this test is to determine the Maximum Dry Density and the Optimum Moisture Content of a soil sample. without knowing about MDD and OMC we are unable to calculate the compaction after conducting a Field Density Test.
Modified Proctor Test is basically used where high compaction is required.
After watching this video you will be able to perform the Modified Proctor Test.
---------------------------------------------------------------------------
Please subscribe our CZcams Channel and press the bell 🔔 icon to get more info about Civil Engineering Practicals.
-----------------------Channel Link---------------------------
/ @hasnaingoshar
---------------------------------------------------------------------------
💠*Standard Proctor Test *💠
• Standard Proctor Test ...
Video lecture Links:
📍----------------------Channel Link------------------------📍
/ hasnaingoshar
🔘⭕-------------------------💠-----------------------------⭕🔘
💠*Quality Controlling from Asphalt Batching Plant*💠
• Quality Controlling of...
💠*Los Angeles Abrasion Test of Coarse Aggregate*💠
• Los Angeles Abrasion T...
💠*Quality Controlling from Concrete Batching Plant*💠
• Quality Control from C...
💠* Calculation of FDT Test*💠
• Calculation of Field D...
💠*Calculation and Plotting of MDD and OMC Graph*💠
• Calculation and Plotti...
💠*Calculation of FM of Coarse Aggregate*💠
• Calculation of FM of C...
💠*Calculation of FM of Fine Aggregate*💠
• Calculation of Finenes...
💠*Modified Proctor Test**️⃣
• Modified Proctor Test ...
💠*Installation and Lubrication of Compressive Strength Test Machine*💠
• Installation of Compre...
💠*Calibration of CTM*💠
• Calibration of Compres...
💠*Sieve Analysis/Gradation of Coarse Aggregate and Fineness Modulus*💠
• Sieve Analysis/Gradati...
💠*Sieve Analysis/Gradation of Fine Aggregate and Fineness Modulus*💠
• Sieve Analysis/Gradati...
💠*Sand Cone calibration of FDT*💠
• Cone Calibration of FD...
💠*Determination of Unit Weight of Sand*💠
• Unit Weight of Sand in...
💠*FDT/Sand Replacement Method Test*💠
• FDT/Sand Replacement T...
💠*Sand Equivalent Test*💠
• Sand Equivalent Test (...
💠*Calibration of Speedy Moisture Tester*💠
• Calibration of Speedy ...
💠*Speedy/Rapid Moisture Test*💠
• Speedy Moisture Test (...
💠*Moisture Content by Oven Drying Method*💠
• Determination of Moist...
💠*Compresive Strength Test of Concrete Cube using CTM*💠
• Compressive Strength T...
💠*Consistency/initial and Final Setting Time Test*💠
• Consistency, Initial &...
💠 Complete Inspection of Raft Foundation Steel before starting Concrete*💠
• Complete Inspection of...
💠 Complete Layout of Building*💠
• Complete LayOut of Bui...
💠*How to Run a Concrete compressive strength Test Machine*💠
• Compression Strength T...
Surveying and Autolevel
💠* Fly Levelling Procedure*💠
• How to Shift a Bench M...
💠* Building Height by Autolevel*💠
• How to Measure the Hei...
💠* Levelling Staff reading in Feet*💠
• How to read the Levell...
💠* Levelling Staff reading in Meter*💠
• How to read the Readin...
💠* Reduced Levels in Feet*💠
• Determination of Reduc...
💠* Setting of Bubble of Auto Level*💠
• How to Set an Auto Lev...
Always Support
Mashallah bhai BHT khoob
Mashallah bhai❤
❤
Extremely Good
Masha allah
Thank you sir
Thanks 🙏
Husnain bhai concret mix design or job mix formulah b btao plz
What is the sampling of aggregate base course proctor material
bhai jan ap ke sum galat kiya hai wet density nikaltey howey ap ne answer galat nikala hai: 8236/2032.50= 4.0521 ata hai ..... yeee 2.008 kesey agayaaa......??????
Bhai jaan aap compected material ko wapas se original sample me mix ker dete hen, aur phìr 2% pani add ker dete hen, mera sawal he k kia compected material ko original sample me dubara se mix ker skty hen???
G bilkul, aisa hi krty hn
I think so 25 blows per layer
25 blows in standard proctor each layer
25 bar blow kerte hai
Dear, that is for standard proctor test, I have shown Modified proctor test in this video
@@HaSNaiNGoSHaR Apny bola Modified proctor or procedure sample leny ka standard use kia... just check and confirm again
Sir AP bohot achay tarekay say teache kertay hai sir plz AP bataya k Procter test may kitnay method hai or detail b dai day mehrobani hoge
Mdd 2.00 ha ur omc 13.3 ha
How?
You are doing well work.i am new frien d here.u must be com e at my sweet home
Thank you, where
❤