EV Charger ? | EV Installation

Sdílet
Vložit
  • čas přidán 7. 09. 2024
  • In todays video we are carrying out another evec ev charger installation on a property.
    If you would like some more info on chargers or a quote for one to be fitted get in contact via socials
    Tradify you can use my link below to sign up or use code ADAM - it gives 40% off for 4 months
    Tradify LINK - bit.ly/3uJcCnD
    UNILITE - unilite.co.uk CODE - ADAM
    SOCIALS - linktr.ee/adam...
    Thanks for watching :)
    #electrician #viral #trending #apprentice #tools #unboxing #ev

Komentáře • 19

  • @DS1-1a
    @DS1-1a Před 5 měsíci +5

    You’ve just buried hi tuff EV ultra cable directly in the ground, this cable is not suitable for direct burial. Especially in an area where the stones/gravel which could be dug up easily, the cable could become damaged with a spade and won’t trip the OCPD before electric shock occurs.
    In my opinion, the only reason I can see an electrician using tuff sheath/hi tuff, is to make it easier for themselves. Doesn’t take much longer to install SWA glands etc and also the best protection is there, you can’t go wrong.

  • @Rich-Eclipse
    @Rich-Eclipse Před 5 měsíci +1

    2:07 Belden cable is the 2core stuff. Same as you we install the cat 6 version. 2 reasons depending on the charger, you can either use it as a ct & data for hard wired internet or multiple cts on say a zappi install. Meep up the good work buddy 👌🏼

  • @metrotechguru5863
    @metrotechguru5863 Před 5 měsíci +2

    Very nice install. Those clips are brilliant.

  • @Simondofficial
    @Simondofficial Před 5 měsíci +4

    Maybe next time if there is background noise you could still make some clips and do voice over at home explaining what's going on? Just a suggestion

  • @brightsparkmid
    @brightsparkmid Před 5 měsíci +2

    I know you wouldn’t use my clips lol. 😂 cracking install mate 👍

  • @tonywatson1412
    @tonywatson1412 Před 4 měsíci +1

    On the point of burying that cable...to be fair ...anyone can see where and why it went into the ground at that point , and appeared again ...the box.

  • @richrowley8355
    @richrowley8355 Před 5 měsíci +1

    Nice job Adam

  • @Fishbait075
    @Fishbait075 Před 5 měsíci +3

    So, the thumbnail suggests a potential discussion on which charger is best. But that never happens... 🤔

  • @acelectricalsecurity
    @acelectricalsecurity Před 5 měsíci +1

    It looks like the boiler blow off is by the charge point, might have been better to move it a bit further away from the blow off.

  • @stephenfoster5737
    @stephenfoster5737 Před 5 měsíci +1

    Never used them cleets before. No need for wall plug ? Just hit them in or still need a wallplug

  • @chrishorrocks4882
    @chrishorrocks4882 Před 5 měsíci +1

    Use a piece of wood as a buffer between hammer and clip...

  • @Chris-hy6jy
    @Chris-hy6jy Před 5 měsíci +2

    Could you have dug out the gravel and hidden the cable under there?

  • @kerndeath
    @kerndeath Před 5 měsíci +1

    What power bank is that and how many battery’s can you charge from it

  • @ollieb7394
    @ollieb7394 Před 5 měsíci +1

    That cable isn’t suitable for direct burial mate.

  • @aaronmunden3069
    @aaronmunden3069 Před 5 měsíci +1

    Should you if you’ve not done the course?

  • @rustybucket6935
    @rustybucket6935 Před 5 měsíci +2

    Connecting to an MCB on RCD board not compliant m.czcams.com/video/un3KZ8rWy-s/video.html

    • @acelectricalsecurity
      @acelectricalsecurity Před 5 měsíci

      On that Effix link, he said it was acceptable to use the RCD in a split load board, providing it's not a type AC, so with that in mind there's no problem.