Don't ignore your water heater...

Sdílet
Vložit
  • čas přidán 28. 05. 2024
  • Your hot water heater might be ready to fail and it could cost you $1,000’s in home repairs. Look for these warning signs and do maintenance to avoid a disaster.
    Sponsored by WD40 Brand - Get Specialist Penetrant and more at Wal-Mart
    🎥 What to Watch Next:
    DIY Floating Shelves with a Secret - • DIY Floating Shelves w...
    Floating Shelves with LED Task Lighting - • Why don't people do th...
    Smart Charging Station with LED Notifiers - • Smart DIY Charging Sta...
    I Built a Cell Phone Jail - • My son just asked..."W...
    This Table Runs on Batteries - • Making a Table with a ...
    ➤Plans from this build:
    Modular Garage Cabinets bundle (Save 30%) - fixthisbuildthat.com/garageca...
    Sturdy 2x4 Workbench - fixthisbuildthat.com/sturdy2x...
    ➤Join the FTBT Builders Club!!! bit.ly/2abkaSV
    More content, early access, FREE plans, video credits
    ➤Tools/Supplies Used (affiliate):
    WD-40 Specialist Penetrant - amzn.to/464uHul
    ISOtunes Bluetooth Hearing Protection - bit.ly/2Ru4Es8 (10% off code: FTBT)
    Water pressure gauge - amzn.to/43JfMnF
    Soldering torch - amzn.to/43Ww5x8
    Teflon tape - amzn.to/3N9Xchv
    Pipe dope - amzn.to/448Xfkz
    Respirator - bit.ly/3m6500
    Safety mask - amzn.to/448Xfkz
    ➤Support the FTBT Channel:
    Buy FTBT Woodworking Plans: fixthisbuildthat.com/plans
    Buy FTBT Merch: bit.ly/2YgiHnd
    Links to My Tools & Gear: bit.ly/FTBT-tools
    Subscribe: bit.ly/FTBT-youtube
    ➤Thank you to these partners for supporting our channel. Go check them out!
    Kreg Tool: amzn.to/2FXZIGp
    ISOtunes: bit.ly/2Ru4Es8 (10% off code: FTBT)
    TimberlandPRO: bit.ly/2Zm1r1n
    Woodcraft: bit.ly/2qP7JIs
    ➤FOLLOW FTBT on Social Media:
    Instagram - / fixthisbuildthat
    Facebook - www. fixthisbuildthat
    Twitter - / fixthisbuildtht
    Pinterest - / fixthisbuildtht
    Music Licensed through Epidemic Sound - Get a FREE month: bit.ly/3qCwWiW
    0:00 Water heater 101
    3:03 Don't miss these signs
    4:04 Under pressure
    5:52 Don't forget to flush
    7:01 Good rod, bad valve
    8:42 Tearing it all apart
    10:10 This is a bad idea?
    11:38 Sweating it out
    13:13 That was in my water tank...
    14:32 Tank demolition
  • Jak na to + styl

Komentáře • 600

  • @MRANDERSON70
    @MRANDERSON70 Před 11 měsíci +173

    I don’t know if anybody’s mentioned it to you yet or not, but the Bradford white water heaters do have anode rods. With the gas models, they are under the hot water nipple. What was left of the rod is the skinny stick you picked up from the bottom after opening the tank

    • @valazuniga
      @valazuniga Před 8 měsíci +7

      I was going to mention the same thing about the anode rod, or what was left of it. 😅

    • @gardenpondfishgreenhouse573
      @gardenpondfishgreenhouse573 Před 8 měsíci +17

      @@valazuniga I was going to mention that too, anybody else thinking of mentioning that? Please chime in here, It's real important that we hear from everybody and show everybody that if the original poster had not beat us, we would of said the same thing.

    • @jim.h
      @jim.h Před 6 měsíci +3

      Same here.

    • @mondavou9408
      @mondavou9408 Před 5 měsíci +3

      Yep. I wonder how long the water heater would have kept going if he kept up with the maintenance and replaced the rod like he should have?

    • @alert_xss
      @alert_xss Před 5 měsíci +2

      @@gardenpondfishgreenhouse573I was going to mention the same thing but then I saw your post so I decided not to.

  • @Bigfoot14000
    @Bigfoot14000 Před 11 měsíci +56

    That 'barnicle' you found in the tank is probably the remains of the steel rod inside the zinc or magnesium sacrificial anode.

    • @teefill
      @teefill Před 11 měsíci +5

      Definitely. Even though they didn't seem to give access to it at the top, it was there.

    • @SinSpawn9000
      @SinSpawn9000 Před 10 měsíci

      @@teefill I was waiting for him to say that the black spot on the top turned out to be the anode after all but when he pulled the lid i didnt see a hole....

    • @WeBeGood06
      @WeBeGood06 Před 10 měsíci +3

      The size of the anode is the size of the warranty that came with the hot water heater. Replace the anode regularly will replace your warranty as the tank will not rust out.

  • @brianlancaster3709
    @brianlancaster3709 Před 11 měsíci +277

    Hi there! I'm a long time employee of Bradford White. Judging by the model and year of production, there's a good chance I handled a part of that heaters production. It was cool to see the inside of one that's been in the field that long. Anyways, love the content and keep up the great work!

    • @some0ne8
      @some0ne8 Před 11 měsíci +21

      I'm glad he got this install in as practice, you know, for when he replaces that POS Rheem with another BW in 6 months to a year.
      Thanks for making an awesome product, glad you folks still take pride in your work. Bradford White is the gold standard.

    • @raybrown1779
      @raybrown1779 Před 11 měsíci +19

      @@some0ne8 Here in Australia, Rheem is the goto HWS of choice, normal to get 20yrs plus life out of them and a lot are still going 30+ yrs.
      Our plumbing is a lot less convoluted to yours, cold inblet bottom, hot outlet top. Tthe PRV also acts as the primary expansion relief valve so you know its always working properly

    • @MRrwmac
      @MRrwmac Před 11 měsíci +7

      Brian, why was there no anode rod in his? Have HW heater manufacturers found a different way around the problem?

    • @brianlancaster3709
      @brianlancaster3709 Před 11 měsíci +6

      @some0ne8 I appreciate you saying that about our products! I watch this channel because I enjoy the DIY world, unfortunately BW heaters can't be accessed by mos DIY people.

    • @jameskitzmann6268
      @jameskitzmann6268 Před 11 měsíci +14

      @@MRrwmac The metal stick he was hold was part of the rod. They last about 6 years and then will have the rod completly exposed and it rusts away.

  • @normanwitzler9665
    @normanwitzler9665 Před 8 měsíci +33

    Adding a powered anode rod when you install your new water heater is a very good investment. The one I have is called "Corro Protec". The reason your tank rusts and leaks is that the anode rod was never replaced. Also, dielectric nipples need to be installed. You can get over 30 years of use out of a water heater with minimal care.

    • @fakehandle666
      @fakehandle666 Před 5 měsíci +4

      Every modern tank style heater comes with dielectric nipples pre-installed

  • @user-qu7pq5jq5q
    @user-qu7pq5jq5q Před 7 měsíci +27

    Having been a plumber for 40 years, I can say that I've never cut open a water heater or expansion tank. Cool to see. The expansion tank is steel and should not be connected directly to the copper. It's a good idea to add a valve for servicing the tank, which also serves as a dielectric to prevent electrolysis. Always a good idea to use teflon tape and pipe dope on threaded connections. Make sure to wrap the teflon in the same direction as the pipe turns when tightened.

    • @twolfe4295
      @twolfe4295 Před 5 měsíci

      x tank connected to copper is not an issue. adding a valve is not a good idea as someone could turn it off rendering it useless. definately use tape and dope both. jmo

  • @MrCbell57
    @MrCbell57 Před 11 měsíci +108

    As a maintenance man I’ve installed hundreds of these. Ive also seen hundreds working fine and sitting at over 20 years of age. Most People don’t go with the ten year average. They work em til they start leaking. A lot of issues start with how bad the water minerals are. Water is corrosive and a terrible match for raw metal. The two nEver get along.
    Expansion valves are more for water knocking in pipes from the water being turned on and off then heat Expansion. It does work for expansion but really no one has these valves unless they’ve had water Knock in pipes is present.
    Normally water tanks have issues not because of sediment. But due to poor quality of water from plant. And age. If anode rod is doing it’s job it keeps the tank clean. Anode Rods can last a good ten years. Not just 3 or 4 as you suggest. Depends on the water.
    It’s the corrosiveness of the water that damages water heaters. That and failed temperature and pressure relief Valves.
    As well as the fill tube being eaten away due to them being plastic. When that breaks down the cold water is no longer sent to the bottom of tank which allows already heated water to evacuate first. And once you lose your anode rod your tank is left unprotected.
    Great video and you’ve done your home work.
    People need to learn these things so they can understand how they work. The Chances of one of these actually blowing up is about .0001 percent. It’s why they have built in safety features.
    Pipe dope is great and what should be used but you just didn’t tighten these fittings enough. They need to be extremely tight. About 100 foot pounds.
    All in all you presented this video well. And hopefully it helps others understand that they themselves can replace these without paying a plumber company $1000 to $1500 for a new one.
    Good job!

    • @Fixthisbuildthat
      @Fixthisbuildthat  Před 11 měsíci +15

      Thanks! I also think most water heaters can go well past 12 years (like this one). Must be Big Water Heater driving the 8-12 year narrative 😂😂

    • @ellenka22
      @ellenka22 Před 11 měsíci +1

      I do most of the work on my home. I’d love to replace the water heater myself. Between this awesome video and your detailed comment, I feel more confident. Thank you!

    • @PeterHernandez-lg2eh
      @PeterHernandez-lg2eh Před 11 měsíci +4

      I recently replaced my gas water heater. Rusted out at the bottom and flooded the basement floor. Used pex to reconnect. Diyer with lots of CZcams video watching

    • @JerryDerGlatzkopf
      @JerryDerGlatzkopf Před 11 měsíci +9

      Hey fellow plumber. Im from germany and agree with you but not for two points:
      -The Anode should be checked yearly, most of them last about 5 years some up to 7 or 8 years but thats in germany maybe its different in the US
      -I dont think that untrained persons should work with gas pipes. thats extremely dangerous if not done right and youtube is not the best place for some things like this.
      in germany training lasts 3.5 years for this job and after that you learn even more in the real world without someone checking after you.

    • @drippingwax
      @drippingwax Před 11 měsíci +3

      Mom just celebrated 20 years in this house and each water heater has failed after about 5 years. I read about replacing the anode, but this doesn't seem more important than everything else on my list (before I was accepted into grad school), so I am hoping it can wait.
      I offered to replace the water heater the last time, but Mom hired a professional--who had me help him.
      We did not have a ramp.

  • @tomnorman5461
    @tomnorman5461 Před 11 měsíci +12

    7:00 Someone has probably already mentioned this (I haven't read all the comments) but the FIRST thing you should do is turn your gas control to "Pilot" or "off" BEFORE draining the tank.

  • @josephkrug8579
    @josephkrug8579 Před 11 měsíci +61

    I think the 'funky barnacle' was the remains of the hot water tank anode rod. That is in there to keep the tank from rusting, so with yours falling apart, that may be why the tank finally corroded.

    • @rickcimino5483
      @rickcimino5483 Před 11 měsíci +2

      oddly, he said in the video he didn't have one!

    • @josephkrug8579
      @josephkrug8579 Před 11 měsíci +5

      @@rickcimino5483 maybe due to it totally corroding

    • @topc5826
      @topc5826 Před 11 měsíci +9

      Bradford White Water heater doed have an anode rod it slides down into the tank below the the hot water outlet. They use a combination anode rod hot water outlet. you disconnect the hot water output and unscrew the combination hot water outlet tube and anode rod. Let's not forget about the dip tube for the cold water that can be replaced at the same time you're doing the anode rod replacement. If you notice you don't have a lot of hot water that's because the dip tube has deteriorated and the cold fill water is not reaching the bottom

    • @beakthegreat
      @beakthegreat Před 11 měsíci +3

      The rod is connected to the hot water nipple.

  • @russjohnson6396
    @russjohnson6396 Před 11 měsíci +57

    Another suggestion: when I replaced my water heater I installed an automatic shutoff valve at the cold water inlet. A sensor actuates the valve if it detects water on the floor (or in the drip pan, in my case).

    • @Fixthisbuildthat
      @Fixthisbuildthat  Před 11 měsíci +8

      excellent idea

    • @dougsnavely847
      @dougsnavely847 Před 8 měsíci +1

      What brand/model did you use? I’ve been looking at that very idea…. Thanks

    • @disjustice
      @disjustice Před 4 měsíci

      @@dougsnavely847I used a brand called flood stop on mine.

  • @michaelamos75
    @michaelamos75 Před 11 měsíci +13

    Always use tape and pipe dope. Every diyer should replace a hot water heater and toliet at least once. I kept my hot water heater going for 20 years with just a little TLC and replacing the thermal coupler a few times. When hooking up the gas line, always put some soapy water on the connector and look for any bubbles to appear. It's a good cheap way to assure there is not a gas leak.

    • @ibtarnine
      @ibtarnine Před 8 měsíci +3

      Yeah, these aren't difficult jobs, and you can basically make gas connections foolproof with a combination of gas-rated (usually yellow) plumbers tape followed by pipe dope. Many plumbers will use one or the other to save time, and maybe that's fine since they're professionals, but as a DIY'er, just do both to be safe!

    • @lcagee
      @lcagee Před 5 měsíci

      Oatley makes an all purpose leak detector. Ive read that soapy water may cause rust. Not sure if this is true.

  • @Zanthum
    @Zanthum Před 11 měsíci +7

    The air pressure in the expansion tank will always be the same as your water pressure. To check it you have to depressurize your water lines. Turn off the water to your entire house, open a faucet, then take your reading. It works the same as and is nearly identical to a pressure tank on a well, just smaller, and that is the procedure for checking them. Well pressure tank air pressure should be set to 2 psi below the cut in pressure on your well pump so a 20/40 psi well pump cycle should have the pressure tank pressurized to 18psi with no water pressure in the lines. I assume the expansion tank should be set similarly.

  • @derekturner3272
    @derekturner3272 Před 8 měsíci +7

    I opened one that had been on well water for 15 years. It was 60+% full of solid white lime. Could not believe how much and just how THICK it was. Crazy things we neglect. One neat thing was the chunks that had apparently grown on the electric heating element. As the heat cycles, they expand and contract and all off, accumulating down at the bottom. It must have had 15" deep of white rocks on the bottom. Blekt!

    • @lcagee
      @lcagee Před 5 měsíci +2

      I bet mine looks like that inside. Well water. High lime. My WH is a BW and i just discovered it is 40 years old. When heating, you can hear cracking noise inside.

  • @shawnjackson4404
    @shawnjackson4404 Před 11 měsíci +3

    That thing you found in the tank was part of the anode rod. Being a plumber in south Texas we have a hard water issues and the anode rod will last about 1.5 years

  • @davidshaw9993
    @davidshaw9993 Před 11 měsíci +6

    Your "crazy barnacle" was an anode rod. Water heaters don't explode - they leak slowly. If you maintain them properly you can get 30+ years out of it.

    • @Fixthisbuildthat
      @Fixthisbuildthat  Před 11 měsíci

      Yeah, never seen that style rod before. Always seen the ones that screw in from the top

    • @topc5826
      @topc5826 Před 11 měsíci

      @@Fixthisbuildthat it does screw in from the top it's the hot water output side of the water heater.

  • @ElisaShaffer
    @ElisaShaffer Před 11 měsíci +9

    So no joke, our water heater failed this week (it’s in the main hallway of our home). We had to have a remediation crew come in, remove carpet, and we are currently living in a vortex of fans. Great video, wish it came out two weeks earlier. 😂

  • @joshuayoung2643
    @joshuayoung2643 Před 11 měsíci +4

    Down in Southwest LA, they put the water heaters in the attic. Could you imagine the disaster if it decides to go up there?! Great video!

  • @colinnicol9447
    @colinnicol9447 Před 11 měsíci +5

    Here in the UK we stopped installing these heaters about 20 years ago for a couple of reasons. Firstly gas is expensive here and their efficiency rating is about 50-60%. Due to the burner set up being linear.Secondly they are open flued having a draught diverter, they take the combustion air directly from the room they are installed. And if you inadvertently cause a negative situation you can reverse the flue gases back through the draught diverter into the room which can be Co (carbon monoxide). We only fit room sealed appliances now with an average of 90-96% efficiency. All our pressurised appliance must have a 3 tier level of control. Ie thermostat, high limit stat and pressure/heat release valve (PRV).

  • @bradmaas6875
    @bradmaas6875 Před 8 měsíci +9

    Expansion tank pressure should be checked after you turn off the water and open a spigot. If the system is pressurized, it will read the highest pressure, water or air. You pressurize the tank equal to the water pressure.

  • @brucelee3388
    @brucelee3388 Před 11 měsíci +2

    Old hot water heaters had a sheet metal pan that they sat on, the pan had a pipe that ran out of the building so if anything went wrong the water just ran outside. I have a gravity feed heater in the roof that has been working for over 50 years now, only thing that has needed attention is once the float valve stuck closed so eventually the tank ran dry rather than overflowing. If i had to get a mains pressure tank I'd keep the pan (maybe fiberglass the inside of the pan) and put a metal or plastic shroud around the tank to direct any leaks or water spray into the pan to flow outside.

  • @procrastinatingnerd
    @procrastinatingnerd Před 11 měsíci +7

    Lol, our water heater is from 1990 and still works great. My parents have replaced theirs 3 times since their house was built in 2002. If you have a older one, might be better to just keep it working until it leaks. (unless you have it in a place where it would cause a lot of damage, ours is in the basement right next to a drain)

    • @Fixthisbuildthat
      @Fixthisbuildthat  Před 11 měsíci +3

      Yes, absolutely. If it's not in a place where it'll cause damage then let it go til it leaks 👍

  • @craigsymington5401
    @craigsymington5401 Před 8 měsíci +2

    It was a water heater like this that got me into CZcams and restarted me welding and fabricating again about 6 years ago. This is also how I got into "Rocket Stoves" and Rocket mass heaters. And repurposing stuff, anything with scrap metal...
    My father-in-law's water heater failed (attic mount, no drip tray) after only 7 years (5 year warranty), the autopsy revealed a careful placed blow, 4 \lb hammer style, in the side of the glass coated cylinder (dent in foam, so definitely production line installed) and a dented outlet pipe connection (carrier/plumber error?), both points of failure. The replacement was installed by insurance plumbing contractor with a tray and external drain, which was new code in South Africa, as well as new valves. My insurance replacement was moved to outside the building we were renting by the insurance contractor.

  • @tragsifarin9505
    @tragsifarin9505 Před 11 měsíci +5

    I would suggest a dielectric union for the copper to steel connection. Will help stop corrosion and make it easier to connect/disconect.

    • @steveurbach3093
      @steveurbach3093 Před 11 měsíci +2

      If you use those, be sure to electrically 'Bond' the hot to cold (and even the Gas) with #10 - #8 copper wire,just in case someone 'grounded' to the wrong pipe elsewhere.

  • @ibtarnine
    @ibtarnine Před 8 měsíci +13

    A suggestion for people changing the anode rod, especially if you haven't changed it in awhile: Do not even attempt to go at it with a normal wrench. You absolutely need to use an impact wrench. You will almost definitely just strip the bolt with anything other than an impact wrench.

    • @snaplash
      @snaplash Před 8 měsíci +8

      Also, an impact driver won't tend to rotate the whole water heater like a long wrench will.

    • @russelldevane5434
      @russelldevane5434 Před 8 měsíci +6

      Penetrating oil, wait a day, use any wrench next question. 😂

    • @zoso1123
      @zoso1123 Před 6 měsíci

      If i have to uninstall the tank to replace then reinstall why wouldnt i just change the tank? Asking for a friend

    • @ibtarnine
      @ibtarnine Před 6 měsíci +4

      @@zoso1123 You don't have to uninstall the tank to replace the anode rod, you just have to turn the water off, set the pilot light into standby/vacation mode (if it's gas), and then drain the tank fully or partially. Once the tank is drained you can take the rod out, put the new one in, turn the water back on, and turn the water heater back up to your desired temperature. You're also going to want to put a bit of ptfe tape (plumber's tape) around the threading for the rod before you put it in.

    • @zoso1123
      @zoso1123 Před 6 měsíci

      @@ibtarnine how do u fit a rod in the tank without tipping the tank in a basement with low ceilings?

  • @kimorvis3211
    @kimorvis3211 Před 11 měsíci +3

    My tank is an Inglis Cascade 40 that was installed in 1966. The only problem we has was when our village forced us off our wells and put in a municipal well water system. The pressure was much higher than the well system and the drain valve leaked. The village later added pressure tanks and the leak stopped. I do drain it every couple of years because of our hard water. Still waiting for this tank to fail.

  • @jpalarchio
    @jpalarchio Před 11 měsíci +8

    Have been through about three water heaters with the last one failing basically down to the exact month of the 12-year rating.
    Something worth mentioning as part of the replacement is adding an inexpensive leak pan and/or water leak detector for that next time around.

    • @pauljamilkowski3672
      @pauljamilkowski3672 Před 11 měsíci +3

      The leak detectors are hugely important especially if you have a finished area where the water heater can cause major damage. In some towns where I live it's required to have one if your basement is finished or even semi-finished

  • @dscrive
    @dscrive Před 11 měsíci +3

    I cut one up and made a little heating wood stove out of it. If anyone thinks about playing around with these, take respiratory precautions because the inside is lined with glass, I verified it when I tried to weld to it and couldn't get a good ground haha, once I got a good ground I was able to just blow through the glass layer.

  • @osgeld
    @osgeld Před 11 měsíci +2

    2:14 how I figured out ours was about to go, is that all the houses in our neighborhood were built around the same time, and I started to see heaters one by one on the curb over the course of a month or two ... ours was next. House was built in 92 some basic fuzzy math tells me that lasts about 9.8 years on average, and our old one was made in late 2008 and we replaced ours in July 2019. Here's a tip for everyone when you replace your WH, write the month and year on the outside with a marker so its not as much of a surprise

    • @erniemenard7727
      @erniemenard7727 Před 10 měsíci +2

      And don't do it with a Sharpie. I did, and now I can just barely discern the last digit of the year of installation, 2008.

  • @Trapper_Creek_2024
    @Trapper_Creek_2024 Před 11 měsíci +1

    We’ve NEVER had a water heater last more than 6 years because, even with a water softener, our water is full of minerals … and sometimes boulders … or so it seems.
    And yes, our water softener works just fine. It’s actually less than 2 years old, it was purchased through our local plumber (not a Big Box unit), it was professionally installed, we add excellent quality salt regularly, we scrub the brine tank monthly, and we have the unit professionally maintained annually. It’s definitely our water quality.
    I’ve never seen an expansion tank on a water heater before. I’ve seen them on water pumps in houses/barns/field irrigation systems/swimming pools/etc. on properties that have private wells where there is no public water source. That’s definitely not a thing where we live. Interesting.
    The water is black because the water itself ate the rubber bladder. Water does that to rubber after years and years of contact. And yeah, that was disgusting.
    If you had applied your muscles to the heaviest part of the tank, it wouldn’t have taken so much energy to slide it uphill. Just sayin’. Nice little ramp, though.

  • @ranger178
    @ranger178 Před 11 měsíci +2

    one thing you did not mention is you can get a metal tray to put under water heater with a plastic drainpipe attachment to run water someplace where it won't destroy floors and ceilings like a floor drain or outside or something.
    the tanks blowing up like on MythBusters is usually because somebody had water leak from their pressure relief valve because expansion tank failed or they opened it and dirt got in valve, so they unscrew pipe and put a plug in the relief valve. then pressure can get crazy high if they have a city water backflow check valve or pressure reducer which i why they needed an expansion tank. if you don't have check valve expanding water just goes back down cold water pipe

  • @dolph9913
    @dolph9913 Před 11 měsíci +1

    I bought my first house. The temperature pressure relief valve was clogged. Tried to drain the water heater to no avail. Took off the pressure relief valve knuckle. This was under tremendous pressure. Replaced it. Probably bought a few more years.

  • @missionmarkone7484
    @missionmarkone7484 Před 11 měsíci +3

    FYI in Australia, regulations stipulate you have a tray under and heated water vessel with a plumbed in drain.
    There is requirements put on the tray size too.
    Additionally hot water vessels here don’t have a the expansion tanks.
    And finally, some hot water vessels have non-return valves which I would assume is why you couldn’t turn on you hot tap to drain it quicker. If you turn on the cold, it would work.

    • @court2379
      @court2379 Před 5 měsíci +1

      New installs require mostly the same in the US. Though it does vary a bit by state or even county. Floor drain, drain pan, extension on the pressure relief to get it close to the ground (to prevent burns should it go off). In earthquake areas a strap holding it to the walls and flexible pipe connections. Most places require an expansion tank because there are check valves in the lines from the city. As the tank heats up, the thermal expansion has to go somewhere.

  • @Explosiivo
    @Explosiivo Před 11 měsíci +2

    The anode rod is on the hot outlet. Some people are saying it's on the cold inlet, even some saying the dip-tube is "coated." It's just a solid magnesium anode that is connected to the hot outlet nipple.

  • @rexmckinnon
    @rexmckinnon Před 11 měsíci +6

    Great video. One thing to note. It’s in your garage and certain fumes will shutoff you gas. I think the toxic fumes sensor is mandatory on new tanks. At least here in Canada it is. I was painting and my tank stopped working. There is a flashing light that gives an error code. Doing research the toxic fumes sensor was tripped and had to be replaced. About $100 later I was back up and running. I am pretty sure it was a $20 sensor but that’s what I had to pay. Anyway, check your new tank. If it has a sensor you could have issues with what you do in your garage.

  • @lambition
    @lambition Před 11 měsíci +1

    If you replace anode every few years and flush tank every year, the tank will pretty much last forever. Expansion tank failure is often because air pressure was not matched with water pressure. Bladder always stays at expanded state when air pressure is lower than water pressure causing premature failure.

  • @monteglover4133
    @monteglover4133 Před 11 měsíci +6

    Dielectric unions on the cold water inlet and the hot water outlet will help the water heater last longer. The brass valve above the water heater is also a back flow preventer.

  • @topc5826
    @topc5826 Před 11 měsíci +3

    Bradford White has its anode rod which is in the hot water line. It's a combination anode rod and hot water output. The barnacle you found was what was left of your anode rod. Had you changed it when you bought the house your water heater would probably be intact that day you came home to find water on the floor.

    • @DadWil
      @DadWil Před 9 měsíci

      Nice to know about the Anode rod... thanks for the info ... now time to call my plumber an get mine checked out

  • @greenyonder
    @greenyonder Před 11 měsíci +49

    This was both fascinating and helpful. Thank you for using your homeowner problem to educate the rest of us.

  • @cyri96
    @cyri96 Před 5 měsíci +1

    American Videos about are always quite interesting to me as a Professional heating Planner from Switzerland, especially how short the life expectancy for some appliances are.
    Like, we commonly expect the hot water tanks here to last at least around 20 years if not more (sometimes up to 40) though it is also extremely rare to have them directly heated, as most are instead hooked up to the main heating system with a central heat source for both heating and hot water.

    • @snickpickle
      @snickpickle Před 5 měsíci

      I've only experienced this type of system once here in the USA (and in Northern Minnesota, at that), and that was at a lakeshore house we rented in the offseason. Since the crawl space underneath the house was not insulated, nor were the hot water pipes for heating, it was VERY expensive to heat that place during temperatures in the -20 to -30 range (both in Fahrenheit and Celsius)! But we always had hot water! I applaud having a system like that, for the sake of using the heat twice. But unfortunately so many places in the USA use forced-air heat instead of hot water heat.

  • @markkempton4579
    @markkempton4579 Před 11 měsíci +1

    This is easily the best water tank video I've ever seen. Unfortunately, I've learned everything you did the same way, but I appreciate the great job breaking things down.
    I've never seen an expansion tank connected directly to a water heater until I started watching plumbing videos. Must be how it's done when the tank is in the garage. Our basement tank has the expansion tank overhead in the joists in line after the water heater and before the first branch off to the faucets.

    • @russjohnson6396
      @russjohnson6396 Před 11 měsíci

      I think the expansion tank is required by code, particularly if there is a check valve anywhere following the water meter.

    • @markkempton4579
      @markkempton4579 Před 11 měsíci

      @@russjohnson6396 so is mine, but it's not right on the tank

  • @davidkitchen7219
    @davidkitchen7219 Před 11 měsíci +10

    @Fixthisbuildthat - Thank you for this. After watching, I wondered, "how old is my tank?" It was 17 years old, so I called my guy and had a new one put in this morning. When he was taking it out, we found that it was starting to leak out the bottom...probably days (if not hours) from a gusher. Tank is on second floor, so you saved my home from some potential major damage! Thanks!

  • @Sebastopolmark
    @Sebastopolmark Před 11 měsíci +1

    Brad you're killing me. My house was build in 2K5 and it has a Bradford White water heater. I have been talking about replacing it. Maybe I should? ?? ??? Thanks for the kick AND the pressure tank info too! !! !!!

  • @rgsparber1
    @rgsparber1 Před 10 měsíci +1

    I put my water heater in a 3” deep pan and put a leak detector in there. It gave me plenty of early warning when a seam started to leak. The detector sounds like a smoke detector when it goes off (in the middle of the night…).

  • @grn9209
    @grn9209 Před 10 měsíci +3

    Awesome video! We just replaced ours after 12 years since our home was new. One key sign we ignored was how the hot water was not lasting when used ( shower and dishwasher running simultaneously). Love the channel , keep the videos coming!

    • @garyallman3039
      @garyallman3039 Před 9 měsíci +3

      Some times the plastic dip tube can break off. The tube takes the incoming cold water and routes it to the bottom of the tank, so the incoming water forces the (heated) water out the top. If the tube breaks, the incoming cold water will mix with the hot, before all of the hot is used. The plastic tube can be replaced, but after 12 years it was a better idea to just get a new one.

  • @powerbuilder0510
    @powerbuilder0510 Před 4 měsíci +1

    That rod you found in the tank is the remains of the sacrificial anode, thats what left when they're later or never changed 😮 🎉

  • @davidboston7943
    @davidboston7943 Před 11 měsíci +1

    Good PSA! I only learned about water heater maintenance a couple months ago when I had to replace the elements in mine. I originally came from the Pacific Northwest, where we have pretty neutral water, and my parents never did any upkeep on theirs. Now I live in the Midwest, and the water situation is a complete 180.

  • @kellyb7321
    @kellyb7321 Před 11 měsíci +1

    Thanks for this video. I've never done any maintenance on my hot water heater because, well I never knew it needed done. Looks like that will be tomorrow's project.

  • @EeyoreDavey
    @EeyoreDavey Před 11 měsíci +3

    I believe newer tanks that are made from Stainless steel do not use anode rods, might actually be hard to buy a decent WH now that does. I also didn't know about the "annual" maintenance until last year when my 5 year old tank started leaking. I have such awful water where I live that at most people get 6-7 years from our WH's and now I'm cleaning mine every 3 months, and it's crazy the junk that comes out just after 3 months.

    • @snickpickle
      @snickpickle Před 5 měsíci

      We just had a new well dug a year ago (the old one ran dry), and there is roughly 100' difference in how deep the new well was dug. I was quite dismayed at how much CRUD there is in that new well! I blow down the tank once a year now for sure! I've even heard that one should actually leave the water pressure on, so that it will force more junk out. The last time I drained the tank, that's exactly what I did.

  • @alexistaylor969
    @alexistaylor969 Před 4 měsíci +1

    A water heater will last indefinitely if you do yearly maintenance and cleaning.
    Parents' water heater is from before I was born and still looks brand new inside.
    Every year dad will drain out the massive amounts of calcium and then was out the bottom with a hose and shopvac.
    The heating elements are cleaned or changed as needed as well as the sacrificial node.

  • @5ElementsWoodworking
    @5ElementsWoodworking Před 11 měsíci +4

    Nice soldering job! I learned to solder with my Dad when we switched from a coal hot air furnace to a base board hot water furnace. Must have soldered 250 joints that week. I ditto whoever said get a pan, and you can get a water sensor too for cheap. If you have IoT setup at home, they have ones that integrate. If not, they'll just beep super loud. Again, nice job!

  • @miketayse
    @miketayse Před 8 měsíci

    I'm a homeowner with a 12 year, at the end of it's service life, Bradford-White water heater. I called them up with the model number and serial number, figuring if they could sell me the same model, it would speed up installation. They told me they don't sell to homeowners and were of no help at all in trying to locate a replacement. They didn't care at all, in my opinion, when I told them I was a homeowner. I looked about on the internet and found Bradford-White sometimes sells rebraded GE, so if you need a Bradford-White, maybe go that route.

  • @supermatthew222
    @supermatthew222 Před 11 měsíci +1

    Replace that plastic drain valve with a brass one. The plastic ones have a high failure rate I only learned about after it flooded my basement.

  • @trentkiewicz21
    @trentkiewicz21 Před 4 měsíci

    First time in my life I see wd40 ad.
    I've never thought they need an ad, that's not even a product, it's its own category of products

  • @50sKid
    @50sKid Před 5 měsíci +1

    Kind of bizarre how the previous plumber installed the old one by tightening those threaded adapters on first and then soldering them onto the copper lines. I would not have put it back the same way, especially with all those crazy joints. I would have sweated some male ends on to the pipes and then used flexible braided steel lines to connect to the water heater -- exactly like the kind you held up briefly during the video -- although I think you were referring to a shark bite version. They make a version with regular threaded ends on both sides. This makes changing water heaters in the future MUCH easier. I know your new heater was taller but you could have redone the way the pressure reducer was sticking out from the wall like that, maybe pop in a right angle and then go up and reposition it higher so that your ends were in the right place. Also, you could have shortened the metal platform.

  • @LimbaZero
    @LimbaZero Před 4 měsíci

    Haven't seen those. What we had in my childhood home was about 4-6 m3 rectangular hot-water tank. We had boiler in separated fireproof room. It can use oil, wood or peat.
    If I remember right water tank had 3 loops. one for boiler, one for central heat, and last one was for hot tap water. Water tank also had heating elements.

  • @dustmaker1000
    @dustmaker1000 Před 11 měsíci +1

    Excellent - I’m one of those guys that do all handyman things around the house and I even replaced my current water heater. I’ve been hearing for over40years to annually drain the tank to remove sediment…..and I’ve never done it. My current tank is now 10 years old and on my radar for replacement. This video is timely and reminding me that I need to elevate this project. Because of your video, I may cut mine open to see what is inside

    • @erniemenard7727
      @erniemenard7727 Před 10 měsíci

      I've always done my own also. The current gas water heater is a GE bought from HD and installed in Sept. 2008.

  • @missinesita5032
    @missinesita5032 Před 11 měsíci

    I've had to change the water heater in two of my homes by now and I've always wanted to see the insides. Thanks Brad!

  • @kleinisfijn
    @kleinisfijn Před 11 měsíci +3

    That little stick is what's left of the anode rod that you should have replaced 5 years ago. 😀

  • @TekedixXx
    @TekedixXx Před 11 měsíci +1

    About 5 months ago our hot water heater blew all 3 gaskets on the top and was spraying water in my utility room. We discovered it when the hot water was only warm (We have a solar hot water heater inline that heats our ground water to 60+ before it hits the traditional tank) and I went down in the basement to investigate only to see water spraying onto the ceiling. Thankfully it was right next to the sump pump and that part of the room has a isolated ridge stopping any water from escaping, but we still needed a new unit and the accompanying code-required add-ons. The plumber couldn't believe water was coming out of every hole in the top of the tank. The inlet and outlet were both leaking. Unit was installed 2010.

    • @Fixthisbuildthat
      @Fixthisbuildthat  Před 11 měsíci +1

      This is exactly what we're hoping to avoid. Looks like you made it just past the 12 year mark

    • @garyallman3039
      @garyallman3039 Před 9 měsíci

      Did you have an expansion tank installed?

  • @duncancremin1708
    @duncancremin1708 Před 8 měsíci

    Irish here, operating to European standards, so never seen anything like that before.
    Nearest thing we have would be the immersion heater, but those are electric, usually have a replaceable element that goes in from the top, and are always made of a non ferrous metal, like copper or stainless steel.
    With the price of gas or kerosene, I can’t imagine being able to afford to run a burner just for hot water storage. Over here, if we’re using a burner like that for hot water, the hot water storage is heated as a side effect of running a central heating system to heat the whole house. Or, in some systems, there is no hot water storage at all, and the burner instantly heats only the water that’s required right now.
    Thanks for showing this. It clarified a few things and now I get where some of the misunderstandings come from, when people from the US try to deal with regular plumbing over here.

  • @Danman1972
    @Danman1972 Před 11 měsíci +2

    That sucks big time. Been there and done that. A few times. Long story short... keep you turn off key handy and know where your water valve is. If you go on a weeks vacation shut the flow off to the house. I have one that will leave the sprinkler on, but shut the house down. I've had a pop off valve fail, the previous owner used regular PVC for the drain on it. That failed shortly because the glue is not rated for scalding hot water. I was home. Was able to shut the hot water heat fill off quickly. Had a plumber repair it. Despite the down sides, I really do want to go with tankless.

    • @Fixthisbuildthat
      @Fixthisbuildthat  Před 11 měsíci +1

      Oh yeah, I shut our water off every time we leave overnight. I've had too many close calls and friends who had flooded houses when they were gone

  • @farmgrowncountrystrong
    @farmgrowncountrystrong Před 11 měsíci +1

    Perfect timing for this video 👍🏻 We've been having problems with ours and no one else had such an in-depth video.

  • @mr.bianchirider8126
    @mr.bianchirider8126 Před 4 měsíci

    My water heater lasted for 32 years before I replaced it. It was still working with no leaks or rust, but needed to be moved to install a new furnace (which was also 32 years old). I figured if the water heater was moved around and put back, it would start leaking. I’m on a well pump. The water is high in sulfur so the anode was removed when it was installed to reduce the rotten egg smell. The water goes through a softener. Four people lived in the house for the majority of the time. I guess I got my money’s worth. AO Smith gas heater.

  • @cmbarnes13
    @cmbarnes13 Před 11 měsíci +9

    Hey Brad, long-time subscriber and fan of your work. Thanks for putting this up there. The "mistakes were made" shirt I guess was appropriate for this project, although to be fair I think even with all the maintenance all you can do is slightly prolong the inevitable. BTW there is actually a good chance that you do (did) have an anode rod that doubles as the cold side dip tube. My Bradford White has that configuration and I did buy a replacement. Trouble is, my WH is in the basement with a relatively low ceiling so it's a major PITA to change this out.
    Anyway, that "what is this" moment when you tore into the WH makes me bet that is the remains of your former anode rod.

    • @MrRightNow
      @MrRightNow Před 11 měsíci +5

      They make anode rods that are foldable, specifically for the low ceiling situations

  • @travisyarbrough4033
    @travisyarbrough4033 Před 11 měsíci

    Rotten rubber water ....... Cheap water heater also. Our Rheem 50 gallon is nuts !!!! Turned down to first setting and 127 tap temps even outside. Furthest is the shower and it is at 120ish also. Great upgrade for us. Don't think twice folks. That Rheem heater is amazing compared to a run of the mill 50 gallon we had. Three times better. Heater had rotted outside and rod was swiss cheese and half it's original length. Set some reminders on phone calander ( Google ) for maintenance reminders in the future. The reminders show up on my computer and email to make sure I don't miss them in the future.

  • @sbpboyd
    @sbpboyd Před 9 měsíci +4

    You should have tested your water pressure at the heater because of your prv at the heater. Hopefully it was the same because you tested at the hose bib and that is typically before the PRV or the the first water fixture before entering the house.

  • @catcrazy8
    @catcrazy8 Před 11 měsíci +16

    I went tankless years ago and I love it! I never ran out of hot water while raising my six kids. Had the dishwasher running while doing laundry and kids taking showers all at the same time. Bonus - it hangs on the outside of my house and frees up space in the garage, and I don't have to worry about damage to my home.

    • @mrcrash5555
      @mrcrash5555 Před 11 měsíci

      Do you have problems with the unit freezing in the winter. Never understood putting them outside.

    • @caroljeannephillips8794
      @caroljeannephillips8794 Před 11 měsíci

      Are you saving $ in the long run? What size are you using and what size is your house? We need to change out our water heater and we're seriously considering going to a tankless system.

    • @pilotdog68
      @pilotdog68 Před 10 měsíci +1

      ​@@mrcrash5555they probably live somewhere like Florida

    • @monteglover4133
      @monteglover4133 Před 9 měsíci

      @@caroljeannephillips8794 we had a tankless in our previous home really like it showers and laundry at the same time.
      How ever some periodical maintenance should be performed for maximum efficiency

    • @tizme6105
      @tizme6105 Před 8 měsíci +1

      We have just gone to a High pressure tankless system too. I took the old LP hotwater cylinder out and checked the date stamp on it - 1953 30 Imp Gal copper tank. It was actually the old 1" galv pipe (at the BSP threads) that gave out, not the tank. Amazing difference in hot water supply.

  • @Gantorin
    @Gantorin Před 11 měsíci +2

    I am moving into my new house soon, so this was VERY valuable information. Thank you!

  • @emmetmyers
    @emmetmyers Před 8 měsíci +1

    Never leave a leaking fitting on top of your water heater. Leaks on top of your water heater destroys more water heaters than rust from the inside

  • @MrKen-wy5dk
    @MrKen-wy5dk Před 11 měsíci +1

    I've been using a whole house water softner for over 20 years here in Houston. Water heater still going strong and no deposits around my faucets, ever.

  • @Acheron2010
    @Acheron2010 Před 7 měsíci

    We're in the process of purchasing a home in Alberta, Canada. The home has a ten-year old water heater. In obtaining homeowners insurance, I was surpised to learn the insurance company will add $300 a month to your premium if your water heater is >10 years old.

  • @BeugsTheLegend
    @BeugsTheLegend Před 11 měsíci +1

    The amount of scale buildup is determined by how hard your water is. If you lived in Texas instead of Tennessee, you probably would have had a foot deep of scale down there.

  • @mattstalford9769
    @mattstalford9769 Před 11 měsíci

    I always wondered what the expansion tank was for (didn't know about checking the air pressure on top). Had my water heater replaced about 4 years ago and it gets yearly maintenance now. Great informative (and destructive) video!

    • @steveurbach3093
      @steveurbach3093 Před 11 měsíci +3

      Expansion tanks are NEEDED if there is a backflow or regulator on your house that prevents water from going back out.
      Simple trick: Tap the tank at the end with the schraeder. It should not be a dull Thunk. I would also avoid putting the tank directly above as it absorbs some heat (the bladder does not like heat)

  • @retass1979
    @retass1979 Před 11 měsíci

    That small metal rod inside is what was left over from the anode rod…it is a sacrificial rod made a magnesium alloy…it prevents the tank from rusting and should be changed every 3-5 years. They are sold at home depot…but most people don’t do this critical maintenance.

  • @ARepublicIfYouCanKeepIt
    @ARepublicIfYouCanKeepIt Před 11 měsíci

    The #1 thing every homeowner can do to save themselves money, both on damages from a leak and in replacement cost, is to inspect the sacrificial anode annually. Do not go more than three years without having the anode inspected.
    As Brad mentions, the anode is sacrificial, meaning that it's designed to corrode before the tank. Replace the anode when it's 50% consumed.
    The #2 thing every homeowner can do to extend the life of their water heater is to flush it annually. Importantly, this doesn't mean simply draining the tank. Water must be forced into the tank at the drain level in order to dislodge sediment. A pressure washer wand attached to a standard garden hose works well for this task.
    #3, operation of the TPR valve should be tested annually. Additionally, rather than opening upper level hot water faucets, simply openly the TPR breaks any vacuum that occur when draining the tank.
    #4, checking both the pressure regulator and accumulator tank pressure should be a part of an annual water heater inspection.
    Lastly, use a combination of compressed air and a shop vac, clear any debris accumulated around the combustion chamber; most often from insects, spiders and the like.
    Do these things and your water heater will easily exceed the typical 8 to 12 year life span.

  • @pileofstuff
    @pileofstuff Před 11 měsíci +1

    Note that , depending on your local jurisdiction, it may be illegal to work on natural gas pipes **without proper licensing or certification**.
    It may also void your house insurance, or put you in violation of your gas supplier's contract.
    Be sure to know what your local laws are, and what your insurance contract specifies.

  • @randizzle7659
    @randizzle7659 Před 8 měsíci

    Been a couple years since I've seen your content. Glad to see you still at it and doing well. CHEERS !

  • @redcorset
    @redcorset Před 4 měsíci

    Before you purchase a water heater. Take a strong flashlight and shine it in either of the water ports hot or cold. As you are doing that look into the other water port and by moving the flashlight beam around. Make sure that the tank liner coating is intact, no cracks. Rough handling can cause cracks in this liner. Cracks will be where the tank will eventually rust out. 10 minutes of inspection will save you from an early demise.

  • @richardflanigan9475
    @richardflanigan9475 Před 11 měsíci +1

    That ‘barnacle’ I believe was part of the anode. If you replace the anode every 5+ years and purge the sentiment from the tank yearly you can extend the life of the tank.

  • @johnwehunt4305
    @johnwehunt4305 Před 7 měsíci

    I installed a Rheem Marathon metal free water heater and after the previous revision replacement for the long warranty to the current revision all has been good.

  • @drfrankensteinscreations8513
    @drfrankensteinscreations8513 Před 11 měsíci +10

    Something to think about (and this was added to the local code here not long ago) is to use flexible lines between the copper and the wh just in case it gets bumped or shifted by accident.

    • @ranger178
      @ranger178 Před 11 měsíci +1

      some places actually want you to strap water heater in place, so it does not move or fall over in an earthquake it is not a bad idea even if you have no earthquakes.

    • @TheDroppedAnchor
      @TheDroppedAnchor Před 11 měsíci

      Or roll the cooper tube into a single, 360° circle. The idea is this circle acts as a shock absorber for well, shocks.

    • @denisrhodes54
      @denisrhodes54 Před 10 měsíci

      @@TheDroppedAnchorthat would create a thermal trap

    • @monteglover4133
      @monteglover4133 Před 9 měsíci +2

      In Chicago metro those flexible lines are prohibited by code

  • @Indiskret1
    @Indiskret1 Před 8 měsíci

    My heater is Swedish made and from 1974. Still works perfectly. Will not change what works and (of course) is situated in a room with a drain. (edit due to autocorrect!)

  • @criticalevent
    @criticalevent Před 5 měsíci

    Pretty amazing that it doesn't leak at the flue first.

  • @johnmcrae5043
    @johnmcrae5043 Před 9 měsíci

    My NC house is 31 years old and still has its original 2 A.O. Smith 40-gal electric water heaters. I've been paying Duke Energy an insurance repair premium for 15 years, so I'm sure I've paid more than they're worth by now. I inspect them every couple months, hoping I'll find a leak and get them replaced.

  • @terabyte7979
    @terabyte7979 Před 4 měsíci

    The reason why it wasn't draining faster after you turned on a faucet is because the pipes are most likely not level or graded to drain back to the water heater, there is definitely trapped water in your pipes blocking the air.

  • @FreakGene
    @FreakGene Před 11 měsíci

    Our hot water heater is currently about 25 years old. In an unfinished basement so just waiting for it to leak to replace it. Or whenever we finally decide to redo the plumbing (house has old iron pipes and a questionable planning to them, the hot water connects back to the cold water at the end by the master bathroom so it takes forever for hot water). Still try and flush it out every so often, but unsure how well of a flush is as the shut of valve to the tank doesn't work. Also the original owners installed it so everything (temp, pressure release, flush) is against the cement walls in a corner so thats always fun...

  • @IXISSV
    @IXISSV Před 11 měsíci +1

    Here in the UK, our hot water tanks are made of copper. Tho these are going out of fashion with the popularity of combi boilers (they produce heat & hot water) that give hot water on demand.
    Interesting video tho 👍🍻

  • @jeffforbes3772
    @jeffforbes3772 Před 11 měsíci

    Cool stuff and great info. Thank you sir!

  • @dave23024
    @dave23024 Před 4 měsíci

    Our attic water heater piping sprung a leak, and I only noticed it when a hallway light downstairs was full of water. It was pretty funny.

  • @TheUnknownDutchman
    @TheUnknownDutchman Před 11 měsíci

    Five years ago mine exploded while I wasn’t home for the weekend. Got a call from the neighbors below me. They had water streaming from their ceiling. Combined with water coming through my exterior wall they suspected it might be my house with the leak.
    By the time I got there there was an inch of water throughout my home.
    That’s a day I did not enjoy.

  • @jonathanshumpert9549
    @jonathanshumpert9549 Před 11 měsíci

    I just replaced my water heater a few months ago. It has been in the house since before I met my wife about 19 years ago. It had so much gunk/sediment in the bottom that the drain valve would not drain. Thankfully it was mounted close to the floor so I didn't have too much difficulty moving it despite it having 50 gallons of water.

  • @denit0
    @denit0 Před 11 měsíci

    This same thing happened to me a couple weeks ago, except it was inside the house. Luckily my room is right next to it, so I heard it in enough time for it not to cause too much damage. Just some wet carpets and a few wood boards for the floor that need to be replaced

  • @hersir557
    @hersir557 Před 11 měsíci +3

    I love the fact there are no water heaters in iceland, it just comes hot from the ground into pipes that connect to every house.

  • @imark7777777
    @imark7777777 Před 8 měsíci +1

    Don't know what your set up is but opening a hot water faucet should break the airlock and allow more water to come out but you might've already been at maximum flow due to holes rust etc. With Ours in the basement I can either open the utility sink or the upstairs sink and it does make a difference.

    • @snickpickle
      @snickpickle Před 5 měsíci

      Once the water had started draining when we replaced our heater, I just opened up the emergency valve, which helped. But I regret not opening up a faucet or two, because it turned out to be more efficient.

  • @FloweryThoughts
    @FloweryThoughts Před 7 měsíci

    I had to pay a local plumber to get mine replaced after 21 years only because I couldn't buy one (insert big box name here) within 300 miles of the house to do it myself. It seems like either all the plumbers bought them up, or the stores wanted me to let them contract it out. Oh yeah, about $1,400 total. I didn't have time to F around with a disabled person living here, just get it done today.

  • @darkflux
    @darkflux Před 9 měsíci

    i am a million times sure that my tank is worse than yours. there was a major leak in my basement some years ago, and i wasn't made aware of it for a week or so, and my tank has lots of rusty drip lines all down the outside.
    my 50 gal. tank was marked 2006, but let me tell ya, the glass pane in front of the gas flame at the bottom fell off, and the basement has flooded up enough to cover the bottom inch of the tank at LEAST twice in its life. that it even still runs now is a testament to quality (and the quantity of rust solidifying over it to keep it all together).
    i am just waiting for that Xmas bonus to roll in before i get me a heat pump water heater, and start saving on my gas bills accordingly. stay strong little water heater...

  • @Polarzbek
    @Polarzbek Před 11 měsíci +1

    This is extremely timely as we just replaced our water heater yesterday. Learned a lot from this, thanks Brad!!

  • @flatlander523
    @flatlander523 Před 11 měsíci +1

    You may have just disscovered why you should install a flex hose from the heater to the house. Really a bummer to have a leak on a fitting you cannot tighten. Cut down your pedistal some, get rid of as many sweated connections by installing flex hose and you should be good for another 10 years. I did the same thing you are doing with a tank that leaked and stopped for a year and started again. Owning a house is fix this fix that.😅

  • @stuartgray5877
    @stuartgray5877 Před 4 měsíci +1

    They design the anode rod so that the Heater WILL fail almost exactly ONE YEAR after the warranty expires.

  • @MANSHED
    @MANSHED Před 11 měsíci +8

    I switched to a tankless water heater 7 years ago and never regretted it. Great video Brad. 😊

    • @Fixthisbuildthat
      @Fixthisbuildthat  Před 11 měsíci +1

      Yeah, Michael, I considered tankless. But I couldn't give up the dedicated circuit in the shop

    • @tcg1_qc
      @tcg1_qc Před 11 měsíci +1

      @@noquedaniuno how is gas more secure than electricity

    • @noquedaniuno
      @noquedaniuno Před 11 měsíci

      @@tcg1_qc It is for this case in specific, since he already have a gas installation. Since it only stays on, for as long as a hot water line its open. Besides it only opens the gas if there is a flame, otherwise it will shut down the valve if for any reason it wont ignite or anyways

    • @MANSHED
      @MANSHED Před 11 měsíci

      @@Fixthisbuildthat yea, I get that. I got a commercial grade tankless heater so it needed 2 dedicated circuits but now 3 people can take showers at the same time in 3 different bathrooms and the dishwasher going and nobody runs out of hot water. 😂

    • @tcg1_qc
      @tcg1_qc Před 11 měsíci

      @@noquedaniuno I still don't see how it's more secure. Yeah, he already has gas, and there are safety features, but electricity is still safer.

  • @throttlebottle5906
    @throttlebottle5906 Před 11 měsíci +1

    that's where an unfinished basement, drain pan and floor drain with sloped concrete is nice.
    of course that's all useless when you have an 80 gallon well tank and bump the well pump, causing the rusted "1" drive-line" to break off, now that was a water leak. soaked me and was splashing off the wall to nearly a 15' radius including the joists and underside of floor above, best part the disconnect switch directly in the line of fire, couldn't get to it and had to go turn off at the panel across basement(large horse shoe shape to get around the junk). the floor drain had no chance of keeping up, but by pure luck the large section of floor removed took much f the water.

    • @Fixthisbuildthat
      @Fixthisbuildthat  Před 11 měsíci +1

      that sounds like a viral video if I've ever heard one, lol