Paano mag install ng SERVICE ENTRANCE,MULTI METER BASE, w/ Nema 3R Enclosure para sa MERALCO? Part 2
Vložit
- čas přidán 28. 10. 2021
- hey hey ,
So on this video I will show you how to install a multi unit electric meter base , in philippines .
The unit consist of 9 meter base , Nema 3R , Wire gutter box , Main circuit breaker box, I also used a 200 amperes main breaker, and a 9 pcs 60 amperes distribution breakers, wire sizes I used was a 60 mm2 for service Entrance and a 14 mm2 for the meter base with 8.0 mm2 grounding ,
In wire Gutter box I used a solderless connector with a size of 2/0 -3/0 and a rubber tape and plastic tape for insulation.
The height of the meter base is around 160 cm to 200 cm , and the standard requirement are 150 -210 cm
The height of the wire loop are around 3 meters from the ground,
I also used lock nuts and silicone sealant to seal nema ,and gutter box .
The brand of breaker I used are CHINT
If you have comments and suggestions please feel free to comment down below..
and dont forget to hit Like ,Subscribe and notification bell...
Paano mag install ng SERVICE ENTRANCE, METER BASE, w/ Nema 3R Enclosure para sa MERALCO? |Tagalog
Pano magkabit ng meter base SERVICE ENTRANCE residential tutorial
PAANO MAG INSTALL NG METER BASE | METER CENTER
Paano mag UPGRADE NG SERVICE ENTRANCE WIRE PARA SA METER BASE AT LAGYAN NG NEMA3R? | LINE TO NEUTRAL
LINE TO GROUND O LINE TO NEUTRAL CONNECTION METER CENTER GUTTER BOX GROUNDING SERVICE ENTRANCE EP 10
How To Install Service Entrance | Electric Meter Base Gutter Box
keywords:
Multimeter base
nema 3R
Service Entrance
Wire gutter box
Meter base
MULTI UNIT ELECTRIC METER BASE INSTALLATION (PART 1 )
On This video i will share to you , how i install a multi unit electric meter base (9 meter base with nema , wire gutter box ,and a main Circuit breaker.
I used a 60mm2 THHN wire for service entrance , and a 200 amp main circuit breaker ,enclosed with a weather proof panel box
The wire gutter box is 110 cm in length and 1ft in height, same size in nema 3R
The meter bases are all single phase and terminated as line to line ,
The distribution Circuit breaker are all miniature type Chint brand and are all mounted in a 1 Meter long DIN rail, 63 amperes in capacity.
In the wire gutter box , i didnt used any crimping tools , as alternative i used a R 3/0 - 2/0 Solderless Connector ,insulated with a rubber tape and an Electrical tape.
The Size of my feeder line are 2 pcs no. 14 mm2 pledge dodge . THHN and a no 8 mm2 THHN for grounding.
TAGS,
#multimeterbase
#pinoytechstudio
three phase meter base wiring diagram
milbank meter socket wiring diagram
single phase meter base wiring diagram
multi unit meterbase wiring diagram
service entrance material list
Electricity meter installation guide
how to install electrical service entrance
how to install multi meterbase
how to install multi unit meter base
how to install multiple meterbase
how to install meterbase with nema 3R and wire gutter
how to install meterbase with busbar gutter box
h
here are some of my other videos you might interesred too :
👉IBUILT my own xand Y machine
👇
• Ganito Pala kalulupit ...
👉The secret of automatic lighting System
👇
• DIY Photo switch Wirin...
👉Photoswitch with auxillary contactor
👇
• DIY Photo Switch Wirin...
👉Multi Electric Meterbase installation
👇
• Paano mag install ng S...
👉Automatic lighting system ( motion sensor )
👇
• DIY Motion Sensor Wiri...
👉STOP/START MOTORCONTROL
👇
• STOP / START MOTOR CON...
👉AUTOMATIC WATER SUPPLY AND DRAIN CONTROL SYSTEM,
👇
• Floatless Relay Diagra...
👉LEARN
STOP/START WITH TIMER
👇
• STOP / START with time...
👉I BUILD MY OWN 12VDC POWER SUPPLY IN JUST 5 MINS
👇
• Paano gumawa ng 12v po...
👉I INSTALLED A VARISBLE FREQUENCY DRIVE ON MY ELECTRIC CHARCOAL STOVE
👇
• KalanDe uling Using Va...
👉DIY FOLDABLE FOODCART
👇
• Diy wooden foldable fo...
👉DIY CHOPPER BIKE
👇
• How I built my chopper...
👉CECCATO AIR DRYER TROUBLESHOOTING
👇
• Paano magtroubleshoot ...
👉STEPPING MOTOR AS AC GENERATOR
👇
• Powerful Mini AC gener...
👉GIANT 1KW METAL HALLIDE LAMP TO LED CONVERSION
👇
• Napakalaking METAL HAL...
👉HOW TO INSTALL BIOMETRIC DOORLOCK
👇
• Finger Print doorlock ...
👉HOW TO REMOVE CABLE WIRE JACKET LIKE A PRO
👇
• Electrician ka ? Dapat...
👉DIY PNEUMATIC SPOTWELDING MACHINE OUT OF SCRAP MICROWAVE OVEN
👇
• Pneumatic spotwelding ...
👉HOW TO QUICKLY REPLACE BROKEN DOORKNOB AT HOME ( DO IT YOURSELF )
👇
• Quickly Replacing brok...
👉BLUETOOTH EARPHONE HACKS
👇
• Bluetooth earphone Hacks
👉DIY MP3 FUNCRION FOR PLATINUM REYNA KARAOKE
👇
• Platinum videoke machi...
👉HIGHTECH TOOLCART
👇
• Video - Jak na to + styl
Sarap talaga panuorin mga ganitong workmanship, sobrang linis pagkagawa. Thank you for sharing sir 🤟
Grabi Ang Linis na pagka install.100%.
Sir good work excellent electrical enstalast well done
Ayos Lodi maraming salamat sa pag share Ng iyong nalalaman
Nice one lods..ang linis...
Ayos bro...malinis
Galing mo idol.........
I'm salot about your job experience sir no comment good job well done sir thank
Ang husay master
1st time ko makakita nito kung Anong Meron sa loob di lang Pala bus bar pd din Pala Yan kulay yellow na nilalagyan Ng rubber tape itatape. Salamat sir sa pag post mo
Oo boss ... png low budget yan
Nice malinis ang pag kakagawa u idol
salamat sa pag appreciate idol
Good job master
Full support po ako idol
Maganda malinis ang trabaho sana all
Salamat po
Busbar n lng sana Yung main bonding joint, tsaka dapat green n Yung grounding conductor papasok ng Bahay/unit, ok na din nman maayos Ang harnessing ng wire
Nice ka electrical miniature breaker na gamit mo more power
Ang galing nyo boss
Salamat ,salamat
❤️❤️❤️
Bagong kaibigan bro enjoy watching
thankyou lods
Silicone on bottom instead of lockrings, or Myers hub. Nice
Could have used Polaris taps instead of split bolt. Pretty scary.
Hello @@whophead6837 Where can we buy Polaris Taps in the Philippines?
Thanks...
bosing anu ano po ba materyals na gagamitin sa paggawa ng maraming meter base at ano po ba sukat ng tubo salamat sa pagsagot ha more vlog pa kasi nanonod ang anak ko electrician din bago pa lang sya ❤️
boss. anong number gagamitin na solderless connector
para sa 60mm.sq kasama yung 8mm na wire??
master may limit ba na bilang kung ilan pwedeng metro pag samasamahin sa iisang gutter? tsaka may binibigay din ba si meralco na guide(yellow card) para sa ganyang multi meter base installation? salamat!
60amp po ang main kada isang meter base 39pcs po ang meter base
Sir, ung 3 unit na meter pwede b wire gutter box sa line side lng ? Para 1 RSC o IMC lng. sa load side pvc na. Thanks
bro, anong size ng nema 3r wire gutter box for 9 meter base, ty
Brod. Ano ba tawag Dyan sa box na mahaba yung nilulusutan ng meter base yang dalawang metal box kinabitan mo ng connector Ikaw ba gumawa fabricate nyan o nabibili na ng gawa yan
Boss ask ko lng Po kaya Po bang hilain Ang #2 size na wire sa dalawang liko? 2 elbow Po ? Incase d kaya mag pull box ako
Undersized ang Entrance Wire sa 200A👍👍👍 dapat 2/0 awg, 60mm² na Wire.
Ano po size para sa 22mm2?
Idol. Ask ko lang po. Anong size ng solder less connector ang gamit mo?
Boss ok lang pala na hinde naka separate ang per CB mo sa baba???
Boss Meron po ba kayong Wiring Diagram po neto?
Anong size ng sorderless connector gamit nyo sir?
Sir yong meter base po nakalapat po ba sa wall???
bos ilan power factor mo sa main?
boss anong pong dimension ng wire gutter nyo? mag install din po kase ako ng ganyan karaming meter base.
Bakit my breaker s gutter pwede ba yun..ayun sa PEC ba.?mster..dipa pwede C-Clamp cu. Then use Crimper ..5 star ..yun lang mahirap hanapin ung plastic bushing..
Sir anung height pala ng meter base mo bus bar gutter pati yung breaker gutter mo salamat
Magkanu singilan pag kabit nyan idol?
mgkano po singil nyo jan sa pagkabit ng 8meter base sir?
Sir ano no.ng wire mo sir sa line side mo sir.salamat po sa reply
Sir ano ang size ng white na wire mo at yong yellow wire at anong klasing breaker ang gamit mo at ano ang amperahi Ng breaker? At pwedi Po ba wala ng transformers
.?
Boss ano size ng gutter
Boss. ang tanong ko ay paano malaman kung anong size ang dapat bilhin na busbar. kasi pumunta ako sa maynila para bumili nyan, kaso ang tanong sakin ay anong size ng busbar? eh hindi ko alam kung paano kunin ang sukat. kasi ililipat ko ang 4 metro ko at gusto ko ng ganyan sa video mo
Anog size ng wire gutter mo lods
Anong size po ng service entrance??
sir bkit po 200A ginamet nyo??
Ano dimension ng gutter
Sir pwede po mag tanong
Line to line po ba yan with grounding? Q
Baka po pwedi maka hingi ng diagram nyo pang mga ganyan multiple meter base
Magkano po ang presyo ng ganyang wire gutter?
Paano po ba gumawa nung auxiliary gutter huhu, need namin para sa electrical
pinapagawa po yun sa Fabricatio shop
boss ok lng ba kung bass bar at logs ang gagamitin.
Mas ok yun boss,, mas madali magretighten
see ask kulang po kung line to neutreal po ung power supply po nyan ?
Line to line po yan ..
Sir meron bang pre made na wire gutter at breaker gutter?
Meron nmn siguro sir..
Boss yan bang design na ganyan acceptable sa PEC
Sinunod ko lang yung sa plano lods ...😁
Master size ng wire sa load, at Yung amper ng mcb, salamat
Tatanong ko lang po sana sa 39 na meter base ilang amper po ang main and size ng wirr salamat po
Depende po sa load sched mo master
dapt din po b yung main cb sa loob ng bahay ay 200A din po?
Hindi po .. yung 200 po ay para sa.total load ng mga unit .. tapos sa bawat bahay ay 60 depende sa comp of.load
Lods anong tawag jn sa parang klep Ng ware
Solderless connector po
Sir ask ko lng line to neutral ba ito or line to line.
Line to line po
Ilan ampere yan mcb breaker mo boss
pasensya na boss . late ang reply... 60 amp po both
Thank you for your informative contents. May alam po ba kayong easy source ng tingi tingi lang na tube for meter base? Or any DIY hack as alternative? Mahal po kasi ang buong tube tapos sa isang meter base ko lang gagamitin. Or dapat po Meralco naglalagay nun?
Meron po sa hardware ... Nun may thread na din ,,may 1Ft may 4 inches. Actually binili ko lng din sa hardware ang ginamit ko diyan... 1ft and 4 inch
@@PinoyTechStudio maraming salamat.
Pa reply sanna boss
Sir, submeter po ba yang ginawa nyo? May pinaka main pa po ba yan na meter?
Hindi po .. nakaaply po yan sa meralco individual
Boss line to ground connection yan boss line to ground po.anung sized po ng wire ginamit mo boss
Line to ground po ,No.6 po yung feeder line saka yung sa metro n individual
boss ano pala sukat ng wire gutter mo.
Limot ko n pre .. alam ko 1 feet lapad , tapos 42 inches haba ..
Ilang amps po gamit na breaker?
60 po, main 200
Magaling,pero comment wl po allowance
thanks po sa info
Boss advance electrical installation course Yan ?
Basic electrical course hindi kasama Yan.
di ko din alam .. sir hehe yan yung mga wala n sa school, base na lang sa design ng engr.. or sa gumawa ng electrical plan
Boss ano pong tawag sa box na gamit mo??
wire gutter po
hi sir ano po yung specs ng electrical tape gamit nyo at saan ninyo in apply?
Armak.na.rubber tape at electrical.tape.lods
buti pa jan size 8 ung wire na ginamit from breaker to load side sa taas , samin size 10 na wire lng .. useless na dn kng gumamit kami ng size 8 from load side or service entrance ng meralco papuntang bahay . kng size 10 lng ung nilagay nila .. kumpol pa naman ang wire sa loob ng pvc kaya di dn kami makapg uograde ..
mukhang sasakit ulo nio jan lods in the future
san po nakakabili ng ground rod
Sir .. Paki correct pp ako kung tama pero sa tingin ko ko meron kang violations as PEC code..
Hehe meron po...😂
Para saan yung 200A..ano main breaker
Tas my NEMA 3R pa.
Hnd malinis Yong pagkadali mo bos kta Yong PVC sa ilalim Ng breaker gutter mo,
Bat walang protection sa lineside individual? Tanong lang master, yung protection mo nasa baba sa distrbution. Diba may mga breakers nrin yan sa loob ng apartment or bahay? Dikaya baliktad master? Nkakalito minsan
Actually tama k nmn ,, dapat may protection din individual sa line side .. kaya lang .. yan kasi ang nasa electrical plan...
Ah ok master salamat, base sa plano.😅
😁✌️
Boss pabulong naman kong magkano na ngayon pagkanit nyan metebase kasama na gutter pati brraker at nema?ty naka subscribe naako
Half lng po ng cost of materials ang singil ko..
@@PinoyTechStudio like isang meterbase 500?
Lahat na po yun hanggang gutterbox mga breaker..bsta yang buong set...lahat ng ginamit jan.. At madali lng din nmn po yan iinstall
@@PinoyTechStudio oo boss haha curious lang boss student palang ako pero nag practice nako mag install kso dikopa alam singil ng isang buo installation nyan.
Ah ok po .. ganun nmn po plagi ang singilan .. 50% ng cost of materials .. yung iba nman .. binabase sa kung ilang araw gagawin .. or per device
Update boss ng proj? Approved naman ni meralco?
naaprove lods ... wal nmn naging problema
12:45 @@PinoyTechStudio Boss matibay ba ang MCB ilalagay sa outdoor compare sa typical na Circuit? Breaker?
3phase po connection niyo?
Single phase po yan line to line
Boss taga saan ka? Pwede magpagawa sayo? ano po contact number mo? Salamat
Nasa rizal area po ako ngayon ... sorry late reply
Magkano presyuhan ng ganyan?
1500/ meter base lang singil ko boss + 15%
@@PinoyTechStudio magkano po yung ganyang wire gutter?
Magkano po total gastos sa ganyan? Salamat po
boss taga saan ka and pwede ba makuha contact number mo. thank u
Batangas ako ngayon boss