Split AC Installation Guide|| Ac को लगाने का तरीका। LG 1.5 TON 5 STAR DUAL INVERTER AC

Sdílet
Vložit
  • čas přidán 26. 08. 2024
  • #Lg1.5ton5starac
    #Ac
    #acinstallation
    #1.5tonAc
    #lg
    #Acunboxing
    #Tanusuperstar
    Buy Lg 1.5 ton Ac
    amzn.to/43YpnqK
    ac installation charges,
    ac installation house,
    ac installation tools list,
    ac installation hindi,
    ac installation without hole,
    ac installation at home,
    ac installation accident,
    ac installation apartment,
    ac installation accessories,
    ac installation all tools,
    ac installation and uninstallation,
    ac installation and uninstallation charges,
    ac installation by flipkart,
    ac installation business
    ac bracket installation,
    ac breaker installation,
    ac installation step by step,
    ac installation cost,
    ac installation charges split,
    ac installation copper pipe,
    ac installation cost in india,
    ac installation drill
    ac duct installation,
    ac disconnect installation,
    ac duct installation home
    split ac electrical installation,
    automatic ac installation in ertiga,
    ac installation full process,
    ac installation full video,
    ac installation fails,
    ac installation fee,
    ac installation free,
    ac installation financing,
    ac full installation,
    ac furnace installation,
    ac installation guide
    ac gas installation,
    ac grill installation,
    ac guard installation,
    lg ac installation,
    lg ac installation charges,
    lg ac installation 2022,
    lg ac installation hindi,
    ac installation high rise building,
    ac installation hole,
    ac installation hindi 2021,
    ac installation height,
    ac installation hindi step by step,
    ac installation hawaii,
    ac installation in car,
    ac installation in alto std,
    ac installation in maruti 800,
    ac installation in tamil,
    ac installation in flat,
    ac installation in gypsy,
    ac installation interview,
    ac installation job,
    ac installation japan,
    ac installation kaise kiya jata hai,
    ac installation kaise karen,
    ac installation kit,
    ac installation kochi,
    ac installation kukatpally,
    ac installation kit price,
    ac installation kit jiji,
    ac installation lg,
    ac installation left side,
    ac installation labor cost,
    ac installation los angeles,
    split ac installation long distance,
    ac installation in living room,
    alto vx ac installation lahore,
    ac installation marathi,
    ac installation meaning in tamil,
    ac installation madurai,
    ac installation mira road,
    ac installation miyapur,
    ac installation manikonda,
    ac installation material,
    mac installation,
    mac installation for uti pan,
    mac installation error,
    mac installation on windows pc,
    mac installation stuck,
    mac installation failed,
    spice money mac installation,
    flutter mac installation,
    ac installation nallagandla,
    ac new installation,
    ac installation tools name,
    new ac installation tamil,
    new ac installation vacuum,
    new ac installation hindi,
    new ac installation charges,
    new ac installation telugu,
    ac installation on plywood,
    ac installation on beam,
    ac installation outdoor,
    ac installation on wall,
    ac installation outdoor unit,
    ac outlet installation,
    ac installation in omni,
    ac installation in old house,
    o general ac installation,
    o general window ac installation,
    o general cassette ac installation,
    ac installation process,
    ac installation price,
    ac installation pipe,
    ac installation photo,
    ac installation procedure,
    ac installation pictures,
    ac installation pipe price,
    ac installation portland,
    ac p trap installation,
    ac installation requirements,
    ac installation ranchi,
    ac installation report format,
    ac installation reviews,
    ac installation risk assessment,
    ac installation rebate,
    ac register installation,
    ac installation split,
    ac installation status,
    ac installation samsung,
    ac installation short video,
    ac installation sinhala,
    ac installation sri lanka,
    ac installation scope of work,
    ac installation tips,
    ac installation training,
    ac installation technician,
    ac installation tamil video,
    ac installation tutorial,
    ac installation underground,
    ac installation uk,
    ac installation urbanclap,
    ac unit installation,
    ac unit installation central air,
    ac installation in urdu,
    ac split unit installation,
    midea u-shaped ac installation,
    ac installation video,
    ac installation vacuum,
    ac installation voltas,
    ac installation vijayawada,
    ac vent installation,
    ac valhalla installation stopped,
    ductable ac installation video,
    midea ac installation video,
    v guard ac stabilizer installation,
    ac installation wiring,
    ac installation window,
    ac installation wire connection,
    ac installation work,
    ac installation with stabilizer,
    ac installation wakad pune,
    ac installation whirlpool,
    new ac installation,
    voltas new ac installation code,
    lg new ac installation,
    ac installation youtube,
    1 ton ac installation,
    lg 1 ton ac installation,
    voltas 1 ton ac installation,
    daikin 1 ton ac installation,
    ac installation 2022,
    lg ac installation 2021,
    lg window ac installation 2021,
    hitachi ac installation charges 2021,
    2 ton ac installation,
    2 ton split ac installation,
    3 phase ac installation,
    3 face ac installation,
    3 ton ac installation,
    4 ton ac unit installation,
    5 ton ac installation,
    5 ton ac unit installation,
    samsung 5 star ac installation,
    eeco 7 seater ac installation,
    ac installation in

Komentáře • 748

  • @kk86869
    @kk86869 Před rokem +8

    Thank you bhai mere 1200 rs bacha liye Aapne instillation charge

  • @khajawasiuddin9885
    @khajawasiuddin9885 Před rokem +38

    Jab Outdoor ooper lagana ho toh .
    Indoor ka pipe baahar se seedhe ooper na len.1 fit left ya Right ko mod de.thoda neeche ki taraf rakhe or Outdoor ko connect karen.Baarish ka paani pipe ke zariye andar nahi aayega.
    Or baahar se white cement lagaakar hole bhi band karden..
    Gas reliese karne se pahle achi tarha valcume karen.(Approx 15..to..20 minut )

    • @zahidtechmech1013
      @zahidtechmech1013 Před rokem

      Vacuum kitne pressure par karte hai?

    • @rajtera3103
      @rajtera3103 Před rokem +1

      Bhai LG ke ac achhe hote hai kya cooling thik krte hai kya and durable hai ya nhi

    • @chesta197
      @chesta197 Před rokem

      ​@@rajtera3103 Daikin ac best window lo ya fir spilt

    • @mazharkhan8189
      @mazharkhan8189 Před rokem +1

      Right bahar direct connector nhi nikalna chahiye kyun waale bande ka mood kharab ho jaaye agar lequage hoga to cooling coil ka kaam hua to😂😂😂😂

  • @Dil43STL
    @Dil43STL Před rokem +5

    Bahut hi Accha samjha te hai koi bhi samajh jayega Very Happy

  • @MohsinShaikh-yo7bw
    @MohsinShaikh-yo7bw Před rokem +2

    Ji Aap ne kaam to kiya lekin proper tarike se neahi kiya conection bahar nikal diye or teping bhi proper karni thi or men Vaccum ❤

  • @bonishkhan6931
    @bonishkhan6931 Před rokem +2

    Me to Panasonic ac installation karta hu but pyaar se samjhya logo thanks 🥰

    • @Stoicbaba
      @Stoicbaba Před 5 měsíci

      Plz ye batao agar direct peeche hole na karna ho toh kya ghumaake duur lejaake hole possible hai

    • @rukshanakhatoon8314
      @rukshanakhatoon8314 Před 22 dny

      TECNECIAN se bat kare kripya karke you tube univercity se kam badhaye kare​@@Stoicbaba

  • @SunilKumar-rk8st
    @SunilKumar-rk8st Před 2 lety +155

    Brother I m a technician 10 mint me ac install.... impossible

  • @Nx_blaster_gaming
    @Nx_blaster_gaming Před 2 měsíci

    Achha hua bhai tera video ekha to ab ac thik se laga dunga varna itne din mene sahi ac lagaye hi nahi

  • @vjsoni3344
    @vjsoni3344 Před 2 lety +12

    Earth wire is very important
    And vaqqum जरूरी h

  • @newgilltruckbodypatran
    @newgilltruckbodypatran Před 2 lety +22

    Bhai agar leakage hogi v to 50 ke pressure pe samne nai ayegi,kam se kam 200 ke pressure pe samne ayegi,koi faida nai 50 pe check karne ka

    • @khdvideo
      @khdvideo Před 2 lety +2

      hame 110 ke pressure. pe chaik karte hai

    • @Mr.bd_HVAC
      @Mr.bd_HVAC Před 2 lety +2

      Mea compressor k jarye 250 psi par lick check karte hai

    • @gkairconditioner9858
      @gkairconditioner9858 Před rokem +2

      Hame450 psi pr check krte hai

    • @SSGRUPENTERPRISES
      @SSGRUPENTERPRISES Před rokem +2

      Bhai likiz 10 pr bhi dikti h phle usko bdiya se heet kr lo fir saaf krke chek kro kitni bhi choti likiz ho khud dikh jayegi aur zyda tr zyda srf ka use kro pani chikhna hona chahiye ok bro

    • @jakirhusain5610
      @jakirhusain5610 Před rokem

      Use ye to pta nhi pipe ka size kya h.wo bolra mota mote me ptla ptle me 🤣🤣🤣

  • @biswas7773
    @biswas7773 Před 2 lety +22

    No tapeloon, no vacuum, no earthing, leakage check at 50psi
    Who are you?

    • @rvaircon
      @rvaircon Před 2 lety +2

      50 KA PLEASURE dal Kar usko Vacuum bhi nahi Kiya,Kam se Kam flush Vacuum to Kar lete.
      New Installation Mai Pressure Dalnai ki sayad tumhe jarurat nahi padni chahiye, Jab tumahari paas Completely Sab kuch nya ho.
      In bhai sahab ko Working conditions mai dena tha kya keval, Jo ho gya.

    • @rohitchopra8911
      @rohitchopra8911 Před 2 lety

      Inho ne sasti traning le h 😂

    • @AkashKumar4u
      @AkashKumar4u Před 2 lety

      Jaahil installer and misleading CZcamsr. Yahi hota hai India me. Vaccuming & earthing is very important.

  • @asu54874
    @asu54874 Před 2 lety +2

    10 min. Me installation, tum hi kr skte ho bhai, well done👍.

  • @himanshubhandari3751
    @himanshubhandari3751 Před 2 lety +31

    We need to vaccum it first for better and long run cooling without gas problem. Then release the gas from outdoor unit ...

  • @taufiqkhan9250
    @taufiqkhan9250 Před 17 dny

    Very nice video bhai 👍😄👍😄👍👍😊😊❤❤❤

  • @devilmichael01
    @devilmichael01 Před rokem +2

    I am also AC technician
    Single phase ,three phase and package AC alrounder ❤

  • @ranajitmallick3154
    @ranajitmallick3154 Před 6 měsíci +1

    1. Pipe direct bahar nehi nikal na chahiye, pipe hamesha left se hoke jayega agar akdam jaga nehi hai to hi aisa karna chahiye, technician shortcut mar diya,
    2.pipe bahar nikalne ke bad thora sa niche u band hoke phir upar utna chiye,is se barish ka pani ander jane ka change 99% kam ho jate hai ,
    3. Vacuum is absolutely necessary, with vacuum apka ac ka cooling 5 to 10% kam ho jata hai,
    4.ap ko kisne bataya ki green wire ki kohi kam nehi,

  • @sinvlogs1
    @sinvlogs1 Před rokem +5

    green wire very important bhai.... vo earthing ke kam me ati hai.... Bijali ke jhatse bachati hai usko bhi lagado bhai

  • @lancydsouza1326
    @lancydsouza1326 Před rokem +1

    Jo supply cable mein se yellow/green (ground) wire tumne katke fenkdiya, bahut badiya baat hai. Jisne bhi lagaya tha, ek number ka gadha tha. Vacuum bolne ki cheez tumhare dictionary mein tho hai nahin. Bahut badiya seekhne ko mila tumse. Aage ki santan ko bahut acha sikha rahe ho.

  • @thehawk...bijannandi2640

    Great... installation....I like it...and also hope your next installation and mervelous technique....

  • @satyaprakashsahu1604
    @satyaprakashsahu1604 Před rokem +2

    Good video dear sir all the best thank you so much.

  • @ganeshrajput7756
    @ganeshrajput7756 Před rokem +1

    Good moring bhaiya

  • @palshantanu1993
    @palshantanu1993 Před rokem +6

    This is not an AC fitting method
    What was needed was to tighten the nut on the outside. It would have been better to do it on the inside. The inverter did not vacuum the AC and did not apply the wrapper tape to take it home.

  • @rakeshdey9056
    @rakeshdey9056 Před rokem +3

    Green wire is for earthing it's important

  • @mdfarhanraza7279
    @mdfarhanraza7279 Před 10 měsíci

    Aur ha sir aap ko mahngi lagegi kaam lekin kaam good hoga aur aap happy honge aur me company se is liye kah rha hu ac lagwane ko kiu ke aap ki ac agr demege nikla ya fhir koyi bhi issu ho use hm return karwa sakte hai but aap ka ac agr bahr wala lagata hai to oo garanty nahi lega me parsonal bhi kaam karta hu kabhi karwa ke dekhna bro ok thankyou somch

  • @ManishKumar-mo1jw
    @ManishKumar-mo1jw Před 3 měsíci +5

    Please yaar ac ka istemal na Karen 😢😢😢 kyunki isase chlorofluorocarbon nikalta hai 🫥 jo ki paryavaran ke liye bahut hanikarak hota hai 😢😢 jisse tapman mein vriddhi hoti hai Aaj ham log chalte hue tapman 42 Celsius degree per pahunch chuka hai ho sakta hai San 2050 Tak 50 Celsius degree paarkar kar jaaye

    • @konsamamit7238
      @konsamamit7238 Před 2 měsíci

      2050 main 50 celcius nhi June 2024 main 52 celcius pochgya...

  • @shamsadkhan8902
    @shamsadkhan8902 Před rokem +2

    Bro aap teplon tape use nhi kiye

  • @MuhammadSaboor
    @MuhammadSaboor Před rokem +2

    صلی اللہ علیہ وآلہ وسلمI LOVE ALLAH AND RASOOL S.W THE PROPHET MUHAMMAD S.W THE LAST NABI OF ALLAH KIYA AJ APNE HAZRAT MUHAMMAD S.W PR DAROOD E PAK PARHA ?

    • @maheshpawar9281
      @maheshpawar9281 Před 3 měsíci

      बीच में ये क्या है बे

  • @RowdyAbhay
    @RowdyAbhay Před rokem +3

    Bhai vacuum to Kiya hi nahin aur walls mein teflon tape nahi lagaya 😂 . Kay ac fitting Karega tu 😂😂

  • @nasaruddinkazi7506
    @nasaruddinkazi7506 Před rokem +1

    अरे भाई उसने विडिओ देखकर 10मिनिटमे सिखने का बोला हैं. ना कि इंस्टॉलेशन करने का टाइम. 👍🏻

  • @SakirBabu-xn6vy
    @SakirBabu-xn6vy Před 5 měsíci +1

    Ac ka kam sikate samay kitna rupya dete hai guru ji

  • @learnme7312
    @learnme7312 Před 10 měsíci

    Congratulations 🎉🎉🎉

  • @Firefly7178
    @Firefly7178 Před 5 měsíci

    Hello sir.. Really need help from u. Lg technician came and service my split lg ac but afterward the water from drain pipe stopped coming and even my outdoor unit fan got jam. Is it possible the technician has spoiled my Ac. Kindly need ur advice on this.

  • @sohailsaifi8075
    @sohailsaifi8075 Před rokem +2

    Bhai underground piping bhi hogi tb bhi 10 mnt m fitting na hove

  • @MDAWKHAN
    @MDAWKHAN Před rokem +3

    Brother Split Type Air Condition Not Good installing

  • @turismoknowledgewithrealey2648

    Lol core cutting tool k jagah breker se square hole kiya isme unessesary big hole hota h leakege hone k sambhavna hoti h barsat ka pani papdi nikal jati h wall k

  • @mdaltafkhan8655
    @mdaltafkhan8655 Před 2 lety +9

    Pipe line whole wrong side brother

    • @Loveislam2001
      @Loveislam2001 Před rokem

      Yes

    • @Loveislam2001
      @Loveislam2001 Před rokem

      This is the difference between and a local technician and a good technician...local technician always do this fault

  • @manoharnagdev1616
    @manoharnagdev1616 Před rokem +1

    Only काम कि बात no bkwass...!!! 👍👍👍

  • @Asr129
    @Asr129 Před 11 měsíci

    Iska outdoor part stairs k neeche laga sakte h jo ki room se bahar hai, kyuki ghar ke chaaro side koi jagah nahi chhora gya hai, main gate bhi 3 ft open h only jo ki 90 ft packed gali hai with no proper sunlight

  • @harpreetsaini4933
    @harpreetsaini4933 Před rokem

    Bhai brazing is best than flair nut & teflon tape is necessary to avoid future refrigerant leakage.

  • @viveksingh4572
    @viveksingh4572 Před 2 lety +11

    Does plug top and drain pipe come free of cost while installation or we have to pay extra?

    • @tarunpal6573
      @tarunpal6573 Před 2 lety +2

      60 rs pet foot

    • @Sigma.com07
      @Sigma.com07 Před 2 lety

      @@tarunpal6573 90 rupay mitter

    • @sushantgupta9336
      @sushantgupta9336 Před 2 lety +2

      Drain pipe comes free along with this Indoor unit. 10 feet copper wire both ( think 10 feet & Thick 10 feet) also comes free of cost with remote, all screws

    • @rafirefrigeration4189
      @rafirefrigeration4189 Před rokem +1

      3pin top
      Drain extra xtra charge

  • @gajendrasinghchoudhary4460

    10 by 5 ki gallary hai 11.50 feet height hai usme ek outdoor and ek cooler laga hua hai..cooler ki cooling affect hogi

  • @vickyhdstudio9824
    @vickyhdstudio9824 Před 2 lety +1

    Hello sir aapne jo indoor unit se ges ki pipe nikali hai vo indoor unit ke Left side our Right side kisi bhi side se nikal sakte hai
    And aapne jo ac Lgayeaa hai vo LG
    Ka kon sa modal hai
    Thanks ji 🙏

  • @akashdeep4190
    @akashdeep4190 Před 2 lety +2

    Hi brother good installation but aapane vacuum to Kiya hi nahin

    • @sohailkotwal3042
      @sohailkotwal3042 Před rokem

      New machin ko vacum karna zaruri nh h falash karke bhi ho jaynga

  • @jugalkr.pandey
    @jugalkr.pandey Před 2 lety +1

    System ko ground karay naki Earth wali wire ko cut karay

  • @hem5647
    @hem5647 Před 27 dny

    bhai tum uttrakhand se ho kya?

  • @RizwanKhan-tg3xq
    @RizwanKhan-tg3xq Před 8 měsíci

    Nice information👍

  • @MdIrfan-ez3wb
    @MdIrfan-ez3wb Před rokem

    So beautiful video

  • @HVACTechnician-rp3kh
    @HVACTechnician-rp3kh Před 3 měsíci

    Split AC measurements Video banao Bhai measurements sikhna hai

  • @heerkamalsingh9
    @heerkamalsingh9 Před 5 měsíci

    Bro im mechanic we install ac in 1 hour 👏

  • @bawababbar4857
    @bawababbar4857 Před 7 měsíci

    superb bro

  • @RPxmafia
    @RPxmafia Před 2 měsíci

    Bhai tane direct connection kya h h jo.last h mai indor ka worring ka connection rehta h wo kaha pr kya h

  • @targetdefencebyajayarmy6245

    Gus kholne ke baad bhi aap likej check kar lijiy bhaiya ❤️

  • @Surajbisht_
    @Surajbisht_ Před rokem

    Kya kya samaan lgta h ac install k liye ...jaise stand , pipe aur ..?

  • @comedy11651
    @comedy11651 Před 3 měsíci

    Thank u sar thankyou thankyou thankyou

  • @godfather1235
    @godfather1235 Před 2 lety +2

    Bhai bali 2 hour lag jaye but gallti kuch nhi hone chaiye choti se gallti pura mood off and kafi chiz gallat ho jayegi

  • @altafgaming10k
    @altafgaming10k Před rokem +1

    Aapka plant kaha h

  • @SSGRUPENTERPRISES
    @SSGRUPENTERPRISES Před rokem

    Bhai sb kuch thikh tha pr Do glti bhaut bdi ki h jisse lg raha h aap ek dukaan wale h jisne instolletion ki h na ki DSC wale LG ke ok

  • @vivekshisave8312
    @vivekshisave8312 Před měsícem

    बगर व्याक्युम के बगर ही एसी इन्स्टॉलेशन करते हो क्या

  • @islamunstoppable2204
    @islamunstoppable2204 Před rokem

    Indoor ka stand fit krne ke liye jo hole kiye jate hain wo kitne no. Ki bit se kiye jate hain ?

  • @ranjansinha5119
    @ranjansinha5119 Před rokem

    Great video

  • @khokanmaji1989
    @khokanmaji1989 Před 2 lety +24

    indoor vacuum naahi kiya. very bad installation process

  • @Punpreet
    @Punpreet Před rokem +1

    Most important vecum

  • @subhayuhalder470
    @subhayuhalder470 Před rokem +1

    Vaccum nhi kya

  • @prabhatyadavofficial8606
    @prabhatyadavofficial8606 Před 2 lety +1

    Sir taflon tef bhi laga Dena chahiye tha

  • @muthuselvan6479
    @muthuselvan6479 Před rokem

    Earth is very important

  • @ajmal1856
    @ajmal1856 Před rokem

    sir ac kaam laghbhag kitne time Mai sikha jata hai aur jaise ab sardi hai toh kya yeh kaam sardi Mai bhi rahega jaise hot and cool ac bhi aati hai na aur sikhne par kitne paise milte hai kya yeh kaam 12 ke bara rehta hai plz tell

  • @jamit684
    @jamit684 Před rokem

    I purchased a new llyod inverter ac the outdoor unit stop for few minutes after working then starts agains (Is it normal)

  • @SatyaprasadRoy-gl1dw
    @SatyaprasadRoy-gl1dw Před 2 měsíci

    Thanks sir

  • @Urbanboi2600
    @Urbanboi2600 Před 4 měsíci

    Our technician Didn't vacuum my ac direct on ke diya Pr shi chl rha h any problem??

  • @ameenhashmi2451
    @ameenhashmi2451 Před rokem

    Bhai tum video kiske liye bnaye ho ac technician kr liye ya fir aam janta ke liye agar ac technician ke liye bnaye ho to sab chiz ka name le kar btao

  • @adityavermavlogs4593
    @adityavermavlogs4593 Před rokem

    Osm bahi

  • @anzalkhan0012
    @anzalkhan0012 Před rokem

    Bhout achha video bro❤

  • @rishi____1909
    @rishi____1909 Před 2 měsíci

    bhai installation pipe already rehta hai na box me

  • @AsifKhan-bw2yk
    @AsifKhan-bw2yk Před 2 lety +1

    Kya bhai sahab aap 10 minute ac fit ker sakte ho 10 minute main toh dril holl nahi kar sakte ho

  • @user-zo3qs1ge7l
    @user-zo3qs1ge7l Před rokem

    dear sir aapane Jo yah video upload kiya bahut badhiya hai lekin iska install Karne Ka Tarika pura galat Pahli Baat inhone AC ka jo pipe hai vah back Tu back Kar Diya Yahan per back Tu back karne ka koi jarurat Nahin Hai aur yah inverter machine hai LG ka yah unhone Bina vacuum kiye gas Chhod Diye ya thoda gas Panch bhi kar dete Tu Bhi chalta दो-तीन Sal chalne ka bad machine Mein gas to Phool rahega lekin cooling ka problem aaega

    • @Tanusuperstar
      @Tanusuperstar  Před rokem

      Sahi kha sir aapne ye problem 3 mahine me hi hogyi muje

  • @sushilkori89
    @sushilkori89 Před rokem

    Super 👍👍👍👍👍👍

  • @ashishalok6502
    @ashishalok6502 Před 2 měsíci

    Thnx 😊

  • @My.cocktail.mylove
    @My.cocktail.mylove Před 7 měsíci +1

    500wala technician hai bhai tu to tere kaam ko dekhte huye

  • @balwindersinghbitti9817

    Bhai hole jitna bda marji karwalo . Hole karne me hum bahot mahir hai

  • @Faiztourvlogs
    @Faiztourvlogs Před 2 lety

    Lege rho kamyami milegi

  • @kamalhusainkamalhusain2825

    Very good

  • @AnkitAnkitkumar-ho5oi

    Thanks 🙏💕🙏💕🙏💕🙏💕🙏💕 bhai

  • @AnilDaiya-cb3tt
    @AnilDaiya-cb3tt Před 2 lety +2

    Sir Gas ka pipi mat lagao na 🤣

  • @MDRIJWAN703
    @MDRIJWAN703 Před 3 měsíci

    Pipe nhi tube bolo dost, mistakes no 2, gas open kr ke uske bad volume open krna chahiye.

  • @ManpreetSingh-tr8se
    @ManpreetSingh-tr8se Před 2 lety +2

    Vacuum nai kiye that is compulsory

  • @mayur5471
    @mayur5471 Před rokem +1

    LG ka AC department mai hi sambhal ta hu..... video dekh ke maja aaya😅

    • @rajtera3103
      @rajtera3103 Před rokem

      Sir kuch log keh rhe hai ki LG ke ac cooling kam krte hai kya yeh baat sach hai aap toh department smbaalte ho aapko pta hoga iss baare me

    • @rajtera3103
      @rajtera3103 Před rokem

      LG ke Ac lene chahiye ya nhi mujhe LG bahut achha lgta hai but logo ki baate sun kr dar lgta hai lene me cooling achhi nhi hui toh kya?kroonga

    • @mayur5471
      @mayur5471 Před rokem

      Dekho aisa hai ki apni company hi sbko achhi lagti hai......pr mai ye kahena chahunga LG se bhi achhi cooling wali company hai market me.....

    • @mayur5471
      @mayur5471 Před rokem

      Go for other company.....👍🙏

    • @rajtera3103
      @rajtera3103 Před rokem

      @@mayur5471 other company bahut hai best,ho woh btao

  • @AnilDaiya-cb3tt
    @AnilDaiya-cb3tt Před 2 lety +1

    Technician kha se bulate ho ese 🤣🤣🤣

  • @Masleuddin312
    @Masleuddin312 Před 7 měsíci

    Supar bhai

    • @NavinKumar-vl2xk
      @NavinKumar-vl2xk Před 2 měsíci

      क्या सुपर है बिना वैक्यूम किये इंस्टाल किया गया ,बहुत कमी है इसमें

  • @Vijay-nx7ww
    @Vijay-nx7ww Před rokem

    Brother why have not done vaccum indoor pipe before letting gas? It's wrong.

  • @sauravmmasti
    @sauravmmasti Před 6 měsíci

    Thnx bro

  • @sachinsinduke6615
    @sachinsinduke6615 Před 4 měsíci

    Tq🎉 bro

  • @Yash_0769
    @Yash_0769 Před 16 dny

    RIP to those who try to install their brand new AC themselves 😂...bhai itna kharcha kiya hai thoda oor kr lo km se km warranty to cover hogi and wo log sahi se lga denge.

  • @ahteshamparvez4939
    @ahteshamparvez4939 Před 2 lety +1

    Bhai Mere Ek Baat Btao Tum Aapko Ac Ke Bare Me Sab Samjhta Hai Kya Mota Pipe Patla Pipe Bhai Mere Ye Technician Ki Language Nahi Hai Mere Bhai Aur Pipe Ko Aisa Nahi Bole 1/4 Ka Pipe And 1/2 Ka Pipe Bolte Hai Aur 50 Pressures Aapne Chod Diye Ho To 10/15 Mint Rakhna Padhta Hai Lekage Ke Liye Check Kerne Tak Lekage Milega Mere Bhai

  • @sahilkhan_ssn
    @sahilkhan_ssn Před rokem +1

    Indoor ki Pipes
    ko vaccum to kro bhai

  • @gurname7509
    @gurname7509 Před rokem

    Nyc bro

  • @parvezqureshi7331
    @parvezqureshi7331 Před rokem

    Bhai 10 min ni tu 2 hrs le lekin instalation proper kar left me hole karne me kya problem tha barish ka paani seedha pipe se room ke ander jayega

  • @tarashrestha9679
    @tarashrestha9679 Před rokem

    Good ❤

  • @jandgvlog858
    @jandgvlog858 Před 2 lety +1

    वैक्यूम तो किया ही नहीं जो की इन्वर्टर ac मे बहुत ही आवश्यक है बाकि वीडियो ठीक है

  • @wahidali3871
    @wahidali3871 Před rokem

    Nice dusra video laiye

  • @nishantkushwaha3356
    @nishantkushwaha3356 Před rokem

    Green wire kaam Hota h bha.. Earthing Larne me liye..

  • @SarathiSarathi-cm3gi
    @SarathiSarathi-cm3gi Před rokem

    My ac my all room wow full chilll