AC Coil Is A Block Of Ice! How To Fix And Test

Sdílet
Vložit
  • čas přidán 25. 02. 2023
  • Carrier ac keeps freezing up, customer has to run the ac in the winter because of high heat load. I find high static pressure and other problems.
    - Purchase your tools at www.trutechtools.com/?AffId=42 and use the offer code SURVIVAL to save 8% on your total purchase (exclusions may apply) -
    - TOOLS I USE -
    FULL LIST ON THIS PAGE - kit.co/hvacrsurvival
    💥 Amazon Store: www.amazon.com/ref=as_li_ss_t...
    SHORT LIST IS BELOW
    RIDGID 31305 Model E-110 9.5" Offset Hex Jaw Pipe Wrench - amzn.to/3Bar08y
    Klein Tools Ratcheting Box Wrench 1/4 x 5/16 amzn.to/3GOpBrG
    KNIPEX Tools - 10" Pliers Wrench amzn.to/3U7RRJf
    KNIPEX Tools - 10" Cobra Water Pump Pliers amzn.to/3Wje8Wn
    Knipex Tools - Mini Pliers in Belt Pouch amzn.to/3WguyyH
    KNIPEX Tools - 4" Cobra XS Water Pump Pliers amzn.to/3UaQiKA
    Bahco -6" Wide Mouth Adjustable Wrench amzn.to/3sHIsMV
    Bahco - 8" Big-Mouth Adjustable Wrench with Rubber Handle - amzn.to/3SPhDB7
    Knipex - 9.5-Inch Ultra-High Leverage Lineman's Pliers amzn.to/3DTLJ2h
    Klein Tools Diagonal Cutting Pliers with Angled Head - amzn.to/3zuBVJb
    Klein Tools Stripper, Crimper Tool - amzn.to/3gQQ6Su
    Klein Tools Wire Cutter and Wire Stripper - amzn.to/3Fs627W
    Klein Tools Kurve Wire Cutters, Heavy Duty Wire Stripping Tool - amzn.to/3FseIuW
    Klein Tools Heavy Duty Automatic Wire Stripper - amzn.to/3SQdZab
    Klein Tools Crimping and Cutting Tool - amzn.to/3TPIgXU
    Klein Tools Screwdriver Adjustable 4 to 8-Inch amzn.to/3Nl6KWz
    IDEAL INDUSTRIES Digital Circuit Breaker Finder - amzn.to/3DoBFwm
    Fluke 376FC AC/DC Clamp Meter with iFlex - amzn.to/3UaNyx2
    Fluke 62 Max Industrial Infrared Thermometer - amzn.to/3SNdwWg
    Fluke 902 FC HVAC True-RMS Clamp Meter - amzn.to/3Ws7OfB
    Fluke 87V MAX - amzn.to/3U6Rlv9
    Fluke Networks Pro3000 Tone Generator - amzn.to/3WedklG
    Fluke - FLUKE-52 Dual Input Digital Thermometer amzn.to/3zwFdf1
    Ideal Safe-T-Grip Fuse Puller - amzn.to/3zsw2w4
    Klein Tools Canvas Zipper Bag - amzn.to/3WgnJxq
    Uni-Paint PX-20 Oil-Based Paint Marker - amzn.to/3sE3R9T
    5 Gallon Bucket Topper and Organizer - amzn.to/3sGi2Ll
    Stabila Magnetic Pocket Level PRO with Holster - amzn.to/3FtYLo0
    Clip & Carry Kydex Multitool Sheath for LEATHERMAN SURGE - amzn.to/3TPJfHA
    Kydex Multitool Sheath for LEATHERMAN WAVE & WAVE + PLUS - amzn.to/3sJlhlg
    Cooper Atkins Thermistor Thermometer - amzn.to/3DLeHkC
    GEARWRENCH Internal/External Ratcheting Puller 7 Ton 2 or 3 Jaw - amzn.to/3FxTU5l
    - CONTACT INFO -
    hvacrsurvival@gmail.com
    - FOLLOW ME -
    Instagram - / hvacrsurvival
    Facebook - / hvacrsurvival
    Warning Notice Disclaimer - Video content listed on the channel HVAC*R Survival is for entertainment purposes only and not meant to be a substitute for not contacting a competent HVAC/R PROFESSIONAL. Do not attempt anything said or seen on my videos, The tasks that are shown are dangerous and deadly without proper training.
    This page contains affiliate links, which means that if you click on the link and make a purchase, I’ll receive a small commission. HVAC/R Survival is a participant in the Trutechtools, Amazon Services Associates Program.
    #hvacrsurvival #hvaclife #hvacservice #hvacr #refrigeration #troubleshooting
  • Zábava

Komentáře • 64

  • @jsfkdkjslfdslfkdj
    @jsfkdkjslfdslfkdj Před rokem +14

    Those switches last way longer if you add a relay for the fan and use the switch to break 24v to the coil

    • @topher8634
      @topher8634 Před rokem

      I agree. You won't be switching as large of a load.

    • @tomoliver8498
      @tomoliver8498 Před rokem +1

      You would think the little screw on switches would last longer when switching a relay but I have not had any better luck doing so. After 2 of them failed in a short period of time on the same system I installed a ranco like in this video. Been working fine ever since but I did leave the relay in the circuit.

    • @topher8634
      @topher8634 Před rokem +1

      @@tomoliver8498 I don't like the encapsulated switches either. I think the repeated cycling just causes them to fail whether you use a relay/contactor or not. I usually use the Ranco switch combined with a relay for small motors and a contactor for the larger motors. If the motors have sleeves instead of ball bearings then I try to sell the ICM head pressure control kit. Some customers don't want the extra cost even after you explain shortened motor life to them. 🤷‍♂️

    • @HVACRSurvival
      @HVACRSurvival  Před rokem

      I agree 💯👍👍

  • @liam3284
    @liam3284 Před rokem +3

    A heat recovery system would do great there, madness there is no economizer.

  • @JoseRodriguez-xh6qo
    @JoseRodriguez-xh6qo Před měsícem +2

    Bad ambient control causes ice freeze up traditional ambient control recommended.

  • @stevencossaboon3237
    @stevencossaboon3237 Před rokem +1

    Nice work Rick. Thank you for the knowledge.

  • @Eddy63
    @Eddy63 Před rokem +1

    Nice little vid Rick ... Thx for posting ...

  • @jerzyaheardz6939
    @jerzyaheardz6939 Před rokem +2

    Personally a fan of ICM 333 with the pressure transducer for low ambient fan control back when I was doing HVAC service, used to carry a few for situations like this

    • @HVACRSurvival
      @HVACRSurvival  Před rokem

      We use the Total Line version from Carrier 👍👍

  • @natepeterson7145
    @natepeterson7145 Před rokem +1

    Dewperheat for superheat bubcool for subcool per hvacr school, another way to remember glide

    • @HVACRSurvival
      @HVACRSurvival  Před rokem

      I like that 👍👍. Whatever makes it easiest for somebody to remember is good with me 🤜🤛

  • @WaffleStaffel
    @WaffleStaffel Před rokem +1

    I have a 28 year old Coleman in a manufactured home. It's on life support, and I'm doing manual defrosts, as we're in the PNW and defrost is only needed maybe 15 days out of the year, and I don't like to run the heat strip. A recent snow storm knocked loose the wires I was using to operate the fan and reversing valve from inside, and I was unable to stop the fan for one night, so the coil only half defrosted. Too late to make a long story short, but even with a half inch of ice obstructing all airflow, I guess the heat of the compressor was enough to satisfy, because it wasn't running continuously.
    This thing has taken a fair amount of abuse and kept running nicely. I won't be too heartbroken if it gives up the ghost, because I'll be able to install a mini split.

  • @koreylee611
    @koreylee611 Před rokem +1

    Awesome video thanks for posting.

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC Před rokem +4

    I like those ICM fan speed controllers...i tend to not use that thermistor that it comes with, and i usually install the optional transducer. Hopefully its a ball bearing motor and not sleeve bearings. Great video as always Rick
    The vinyl tubing is a great trick to keep from rub outs

    • @HVACRSurvival
      @HVACRSurvival  Před rokem +1

      We use the Total-Line version, usually these motors are cheap sleeve beings.

  • @HughesManHVAC
    @HughesManHVAC Před rokem +1

    Great vid Rick!

  • @harrydickson4575
    @harrydickson4575 Před rokem +1

    Nice job 👍👍👍

  • @Bobherry
    @Bobherry Před rokem +2

    Nice video.

  • @marvinsellers4457
    @marvinsellers4457 Před rokem

    Better safe than sorry my man it’s the little things sometimes that saves you Heart ache

  • @sterlingarcher46
    @sterlingarcher46 Před rokem +1

    Over here they have kind of a plastic " serpentin " which is almost like a piece of vinyl tubing but cut in a way that you can wrap it around a capillary tube very easily , and it protects it just as good .
    It kinda wraps around the cap tube like a cobra snake wraps around its prey , just to illustrate the idea .
    I don't know what the make is or if there even is a part number for it though ...

    • @HVACRSurvival
      @HVACRSurvival  Před rokem

      I'm pretty sure I know what you're talking about. You see it more with electrical wires

  • @scrambler350
    @scrambler350 Před rokem +1

    Those capsule switches are just a callback waiting to happen - best to just change them out with an old mechanical switch like you did.

    • @HVACRSurvival
      @HVACRSurvival  Před rokem +1

      Thanks Mike🤜🤛👍👍

    • @scrambler350
      @scrambler350 Před rokem +1

      @@HVACRSurvival Used to change the ones out on the units at our local 911 Dispatch annually - now I have them all changed out to the oldschool refer controllers.
      The capsule ones are definitely quicker to install, but you'll just be back switching them out - especially down here where they're off and on 90% of the time....very few days of sustained cold weather.

  • @thestallion504
    @thestallion504 Před rokem +2

    Can you do your MB3 bag setup please? =)

  • @JoseRodriguez-xh6qo
    @JoseRodriguez-xh6qo Před měsícem +2

    69 degree temp will cause freeze up.

  • @JuanTodoli
    @JuanTodoli Před rokem +1

    That Telesin collar seems pretty decent to hold the camera judging for your videos so far. Thinking in buying one 🤔

    • @HVACRSurvival
      @HVACRSurvival  Před rokem

      It also helps having the latest go pro 11

    • @JuanTodoli
      @JuanTodoli Před rokem

      @@HVACRSurvival I have the 8 black and the stabilization booster is powerful.

  • @MrAdamd83
    @MrAdamd83 Před rokem +1

    The vrf systems is what that place needs

    • @HVACRSurvival
      @HVACRSurvival  Před rokem +3

      We have city multi systems at a few places but it's $$$$$, what they need is commercial equipment but these places cut costs everywhere.

    • @topher8634
      @topher8634 Před rokem +1

      @@HVACRSurvival yeah they need a mixed air box and economizer at the least. It's ridiculous to be running mechanical cooling when it's cold outside.

  • @zekenzy6486
    @zekenzy6486 Před rokem +1

    Great Video. Thank you for sharing. Is that low pressure switch you replace ? what is do for AC of that unit ? I saw it on refrigeration unit ? How set up differencial and pressure ? I'm new to hvacr

    • @HVACRSurvival
      @HVACRSurvival  Před rokem

      The switch I removed was a switch designed to close on a rise in pressure and open on a drop on pressure. They refer to it as a fan cycle switch, but it can be used for different applications. The purpose is to build pressure on the high side so that the metering device can maintain a normal suction saturated temperature above freezing. Set can be done different ways but essentially you want to keep your suction saturated temperature above freezing.

  • @Kangenpower7
    @Kangenpower7 Před rokem +1

    The style of fan cycling switch that you removed looks like it is rated at about 1 amp, or pilot duty, and should have a 24 volt coil that is energized by that fan cycling switch to actually power the fan, thus it can last many years. I would rather have the control you installed, good for about 15 - 20 amps at 240 volts, so will also last for years.
    A word of caution, I had to replace a compressor on a small heat pump that had a fan cycling switch (looking at the furnace, you do not have a heat pump) and it was because the fan cycling switch kept the outdoor fan off in the heating mode. I installed a relay that was energized when in the heat mode, thus keeping the outdoor fan energized all the time in the heating mode (unless in defrost).

    • @HVACRSurvival
      @HVACRSurvival  Před rokem +1

      Thanks, yep, I've had to add a bypass relay to heat pumps with fan cycle controls in the past for the reason you mentioned👍👍

    • @topher8634
      @topher8634 Před rokem +1

      @@HVACRSurvival I've had to do this too. Some forget that the condenser becomes the evap in heat mode. The ICM head pressure controls feature a heat mode override but I like those Ranco switches too. The sleeve bearing motors don't like short cycles though.

    • @jasonjohnsonHVAC
      @jasonjohnsonHVAC Před rokem +2

      ​@Topher yup...sleeve bearings need to spin at full speed to wick up the oil onto the shaft...then can slow down. The off/on with sleeve bearings will equal a short life span.

    • @HVACRSurvival
      @HVACRSurvival  Před rokem +1

      @@jasonjohnsonHVAC they can pay me to replace it, since they were the idiots that wanted this kind of system 🤣

  • @MrAdamd83
    @MrAdamd83 Před rokem +1

    Where can I buy them brass tees like you used?

    • @jasonjohnsonHVAC
      @jasonjohnsonHVAC Před rokem +3

      Any supply house. Called swivel tee's. Usually comes in a 3 pack ( JB branded )

  • @throttlebottle5906
    @throttlebottle5906 Před rokem +1

    mmm, tasty pink cotton candy. I played in 36" deep white cotton candy last week, below that was 3/8" plywood, cellulose blow in and pink cotton candy sheets(bats) and of course I had to run wire middle of joist level in the mix of batts and cellulose. snow shovel, circular saw(plywood) and a lot of cussing.
    I've yet to quit itching and scratching from it 🤬🤬🤬

  • @jls1259
    @jls1259 Před rokem +1

    are you close to east palestine where the train derailment is

    • @HVACRSurvival
      @HVACRSurvival  Před rokem

      Luckily no I'm in the north west corner, that was in the south east corner

  • @topher8634
    @topher8634 Před rokem +1

    They using a fan cycle switch for R22?

  • @steveblake8766
    @steveblake8766 Před rokem +1

    194 thumbs up

  • @MrAdamd83
    @MrAdamd83 Před rokem +1

    Do they have returns in each room

    • @HVACRSurvival
      @HVACRSurvival  Před rokem +1

      This only does the hallway.

    • @MrAdamd83
      @MrAdamd83 Před rokem

      @@HVACRSurvival oh ok

    • @MrAdamd83
      @MrAdamd83 Před rokem

      @@HVACRSurvival good job on that particular call I’ll get me some fan pressure controls put on my van asap

  • @wonderhomie2011
    @wonderhomie2011 Před rokem +1

    👍👍✅

  • @specialK_hvac
    @specialK_hvac Před rokem

    I'm curious what the parent company of this facility is, it looks quite familiar to me.

    • @specialK_hvac
      @specialK_hvac Před rokem

      I saw in another comment you're maybe in the toledo area? I'm definitely thinking this is a Tril property

    • @HVACRSurvival
      @HVACRSurvival  Před rokem

      Not in Toledo, not sure who Tril is, but my videos are here to share and help others in the field, not start problems for my customers.

  • @throttlebottle5906
    @throttlebottle5906 Před rokem +1

    "Patient rooms" aka "Victim rooms"

  • @eastcoast186
    @eastcoast186 Před rokem +1

    👍👍👍🇺🇸👀