Tech Tips: How to Address Our MXZ C Hyper Heat System (L)

Sdílet
Vložit
  • čas přidán 23. 01. 2018
  • [updated 1/24/2018: Legal disclaimer added]
    In this video, Jeff explains how to properly address our new MXZ Hyper-Heat (H2i) system.
  • Zábava

Komentáře • 23

  • @kylesoyka7849
    @kylesoyka7849 Před rokem +2

    I watch this video every. Time.

  • @LOOKFAST
    @LOOKFAST Před 3 lety +2

    Why did you set outdoor unit . To 51. I recently did two branch boxes set first 1 to 0,1 2nd box to 0,4 after using 3 zones in first.. what would out door hyper heat address be and why??

  • @jashua2089
    @jashua2089 Před 2 lety

    Thank you for the education!

  • @kingpierre4172
    @kingpierre4172 Před 5 lety

    what are the dip setting for puz-a18nka7

  • @krishnaajaayajayaprakas5475

    Thanks sir also i want be know the heavy industry also please

  • @felixfernandez442
    @felixfernandez442 Před 10 měsíci

    Great information

  • @merajk1389
    @merajk1389 Před 4 lety

    Sir pls tell me how to by pass odu vrf

  • @Ray-wr2wr
    @Ray-wr2wr Před 5 dny

    is this branch box upside down ???

  • @The-LongRoad-Home
    @The-LongRoad-Home Před 2 lety

    Thanks Brada🤙🏼

  • @gundamrx792
    @gundamrx792 Před 11 měsíci

    how do you do this with out a branch box and only a 2 pipe header?

  • @timileyinsheyi926
    @timileyinsheyi926 Před 3 lety

    Greetings, please explain how to check numbers of indoors on outdoor units

    • @johndeerrm
      @johndeerrm Před 2 lety

      The indoor units are essentially addressed by enabling them on the sw1 dip switch

  • @jorgeureno7309
    @jorgeureno7309 Před 4 měsíci

    I have and IT signal adapter. PAC-IT51AD-E. Do you have a video for this? And PFFY-P-NEMU-E indoor unit

  • @taylorthuannguyen
    @taylorthuannguyen Před 6 měsíci

    How about SW 1 dip switch 6? Sgould it be on or off?

  • @georgesizemore7535
    @georgesizemore7535 Před rokem +1

    I am confused. You indicate that in addressing the outdoor unit the first digit is set on SWU2 and the second digit on SWU1. The notes on the circuit board clearly indicate the exact opposite. The note nest to SWU1 says first digit and nest to SWU2 as second digit. There were similar instructions for the branch box but I did not see any notes on that circuit board. Please clarify this for me.

    • @obo7522
      @obo7522 Před rokem +1

      I am right there with you this video makes it more confusing.

    • @Ray-wr2wr
      @Ray-wr2wr Před 5 dny

      it also looks like branch box upside-down or its one of the correct position?

  • @abhinayaircoolservice1000

    Diagram pls sir

  • @edwinneilnovoa1047
    @edwinneilnovoa1047 Před 2 lety

    Hola amigo comprende español

  • @LexaPopov
    @LexaPopov Před 2 lety +2

    I’m sorry Jeff. Rotary dial explanation is very broad and confusing.

    • @Cursey0
      @Cursey0 Před 7 dny

      It’s easy- you’re basically setting the out door unit to address 51. And you’re setting the branch box to address 01. Each port you activate with them be assigned it’s own address. For example, port A is address 01, port B is address 02, port C is address 03 etc.
      It goes all the way up to 50 if you had that many units and that many branch box ports