Inverex Nitrox me masla|Poray Ghar Ki Light Band| Wife ko Mera Idea Pasand nhe aaya
Vložit
- čas přidán 8. 09. 2024
- 6 kW Solar System with Inverex Nitrox Inverter and Canadian N-Type Solar Panels
Inverex Nitrox 6 Kilowatt Inverter: A top-tier inverter that ensures high efficiency and reliable energy conversion. The Inverex Nitrox is designed for optimal performance and durability, providing consistent energy management for your home.
Featuring 12 advanced N-Type solar panels from Canadian Solar. These panels are renowned for their superior efficiency and robust performance, even in low-light conditions. They are built to last, offering excellent energy output year-round.
Our system supports net metering, allowing you to send excess energy back to the grid and earn credits on your electricity bill. This feature maximizes your savings and promotes energy efficiency.
inverex nitrox 6kw,nitrox 6kw hybrid solar inverter,6kw hybrid solar system,nitrox 6kw hybrid inverter,6kw hybrid solar inverter,inverex nitrox 6kw hybrid inverter,nitrox 6kw,nitrox 6kw hybrid inverter price in pakistan,hybrid inverter,solar inverter,inverex nitrox 12kw hybrid,nitrox 6kw hybrid inverter opening,inverex nitrox 6kw hybrid solar inverter,nitrox 6kw hybrid inverter battery settings,hybrid solar inverter,nitrox 8kw hybrid inverternet metering,what is net metering,net metering explained,how does net metering work,net metering for solar power,net metering in hindi,how net metering works,benefits of net metering,metering,net metering 2.0,solar net metering,net metering solar,why use net metering,net metering system,net metering worth it,do i need net metering
net metering,net metering bill pakistan,net metering in pakistan,net metering explained,net metering complete details with zero bill,net metering vs gross metering,solar net metering explained,net metering for solar power in pakistan,what is solar net metering and how does it work?,how does net metering work with solar,5kw diy solar setup update with net metering,net meter bill
@MaazSafderWorld
@WildlensbyAbrar
@sabaKajahaan
@ZulqarnainSikandar25
@MariaClaraeJP
@filmigaane
@LifeOfLimbachiyaas
@lifeofhina5 @MintooFamily @kiranfamilyofficial27 @shalukirar3315 @Man @Drzakirchannel
@PakVillageFamily
@Pakistanifamilyvlog @lokdhunpunjabi
@punjabifamilyvlog1151
@cokestudio @PakistanSuperLeagueOfficial @HumeraAliVlogs
@AliVeerJee
@nasrullahveer6840
@VideoWaliSarkar1
@salmannomanofficial
@Sistrology
@RahimPardesi
@shirazi786
@merimuskan4191
@muskansharma6454
@MuskanKalra01
@MuskanTaqi
@muskanTinkuyadav
@LearningwithShilpa
@shilpakhatwani
@KHANDESHIMOVIES
@infobellshindirhymes
#news #village #cricket #vi#video #videos #party #enjoy #celebration #family #shoaib #sitara #salma #naina #family #new #video #vlogs#rabia #vlog #family #rabia #pakistan #cake #yt #fyp #village #pakvillagefamily #vikrum #india #tech #vlogs #trend #trending #viral #new #latest #psl #kpl #ipl #bpl #uk #kashmir #kpk #news #cricket #video #videos #party #enjoy #celebration #family #shoaib #sitara #salma #naina #zaid #rahim #maaz #aroob #mintoo #maria #family #new #vlogs #yt #family #new #vlogs #yt #family #family #village #vlog #family #rabia #pakistan #cake #yt #fyp #live #vlogger #family #rabia #pakistan #cake #yt #fyp#rabialife #sabaibrahim #sistrology #vikrum #india #tech #vlogs #trend #trending #viral #youtube #search #new #latest #psl #kpl #ipl #bpl #uk #kashmir #kpk #news #village #cricket #video #videos #party #enjoy #celebration #new #naina #vlog #family #rabia #pakistan #sistrology #vikrum #india #tech #vlogs #trend #trending #viral #youtube #search #new #latest #psl #kpl #ipl #bpl #uk #kashmir #kpk #news #cricket #video #videos #party #enjoy #celebration #family #shoaib #sitara #salma #naina #family #new #sabaibrahim #sistrology #vikrum #india #tech #vlogs #trend #trending #viral #new #latest #psl #kpl #ipl #bpl #uk #kashmir #kpk #news #cricket #video #videos #party #enjoy #cel
#family #new #trip #vlogs #yt #video #pakistani #rabia #desi #sistrology #party #enjoy #celebration #shoaib #family #new #video #vlogs #pakistan #cake #village #pakvillagefamily #rabialife #sabaibrahim #vikrum #india #tech #vlogs #trend #trending #viral #latest #psl #kpl #ipl #bpl #uk #kashmir #news #cricket #video #videos #party #enjoy #celebration #family #shoaib #sitara #salma #naina #zaid #rahim #maaz #aroob #mintoo #maria#natasha #natashawaqas #ducky #sabaibrahim #sistrology #vikrum #india #tech #vlogs #trend #trending #viral #latest #psl #kpl #ipl #bpl #uk #kashmir #kpk #news #village #cricket #videos #party #
#india #tech #vlogs #trend #trending #viral #youtube #search #new #latest #psl #kpl #rabialife #salma #naina #zaid #rahim #maaz
City Happy Family
voltage fluctuations,voltage fluctuation test,mitigate voltage fluctuations,voltage drop,calculating voltage drop,voltage sag in power quality,voltage,voltage drop explained,mppt by fixed voltage method in solar pv system,what is voltage drop,voltage protection,low voltage protection,high voltage protection,low voltage
You may adjust AC Voltage high and low level in inverter settings ...
Adjust the high voltage up to 260 to resolve your problem...
But I think it is not advisable, appliances may be damaged due to this. I do not know the safe level of all appliances.
Ma sha Allah, nice information, God bless you end your family❤
❤️❤️❤️❤️
Nice family vlog. Keep it up.
❤️❤️❤️
Assalamualaikum same yahi issue mairai saath be hai nitrox,but I think sub k saath he hai qk panels jab saaf hotai hain aor Barish k Baad mathla be saaf ho jata hai so pv ke production inverter ke capacity sai Thora zyada Jaana normal hai but tripping ka issue different reasons ke wajah sai hota hai chunkai aapko pehlai yai masla nahi aaya so esbar 100% wapda ke waja sai ta,wapda jab stable nahi hota tho yahi hota hai inverter and grid apas Mai sahi nahi chaltai inverter Mai be breaker hota hai jab wapda k high voltage aatai hain so inverter trip karta hai,es ka acha Hal yahi hai k jab yai masla aayai aap export 6000 sai Kam kar k 3,4k per laayain tho aap ke voltage inverter ke control hojayge tab wapda agar Bahar phases Mai zyada be aaraha ho Aapka inverter trip nahi hoga,2nd yai k agar aap phase change kar dogai wapda ka tab be Hal hojaga
W.salam, Arshad bhai. Thank you so much ❤️❤️❤️❤️❤️❤️
G aapki baat bilkul theek hai ❤️❤️❤️❤️❤️
ak din 460 say oper aa gay thy.Allah ka sukar hy humari tu batcht ho gi.aas pass main logo ka bhot nuksan howa.nutrul ka masla ban gya ta tab voltage zayda ho gay thy
Haan nitrox aur iss jaisay inverter safe kr dete hein ghar ko
Problem is at grid side but what you can do is to make sure your grid neutral is properly intact, neutral missing or losing can also cause high voltage. And during such cloudy day high uv's are normal it's not a surge.
Yes brother you are right, thanks
Same problem I am also facing. One phase out of 3 goes over 265V, because of which Inverter trips. Problem happens between 10:30am to 12:00, after that voltage starts coming down. I think the reason for this is too much grid feeding during this time. To push power to the grid, the solar inverter has to increase the voltage to be above grid voltage, then power starts flowing in reverse direction and that is how net metering works. But if too many inverters are feeding to the grid simultaneously, the voltage will keep increasing and that leads to high voltage. 3 phase inverters feed on all three phases and thus, the power is evenly distributed. But single phase inverters send power on only one phase and that can cause imbalance between voltages of 3 phases. One phase becomes too high and the other two are low. If too many single phase inverters are connected to the same phase, that phase will always have high voltage during day and during night time, that phase will suffer from low voltage. Because, during night time, the same single phase inverters connected to that phase will be pulling a lot of current resulting in low voltage. The solution is to ensure that all single phase inverters in the neighborhood are not connected to the same phase, unfortunately you have no control over this, wapda has to ensure this. If you have single phase inverter, then connect your inverter to a different phase that does not suffer from high voltage problem. Second option is to turn off the grid when voltage is not stable or use a voltage protector which will disconnect the inverter from grid. During this time, inverter will run in offgrid mode and you will not be able to export excess energy. But it will protect your inverter.
May be you are right, but it was quite fine during last 2 months, only happened 2 days ago
I personally experienced a similar issue after my solar system was installed last year. Unfortunately, you should know that our grid voltages are rarely stable. Most of the transformers have exceeded their service life, and proper maintenance by the DISCOs (Lesco, Gapco, etc.) is often lacking. Your system will shut down if the grid voltage exceeds the set value for AC overvoltage, which in your case is 250V. You should increase this to 260V, which is still considered safe according to Pakistani standards.
If you are concerned about your home appliances, you may want to install individual voltage and ampere protector devices at their electrical sockets. Refrigerators and LEDs are particularly prone to damage from high voltages, so it’s advisable to install protectors specifically for them. In my experience, inverter ACs can usually handle voltages up to 265V.
Lastly, if your PV voltages are increasing, this could be a rare occurrence. Your DC breaker with a 1000V capacity would only trip if a single string attached to it exceeds this voltage, assuming your solar panels are connected in parallel. When connected in series, the amperage wouldn’t increase.
In short, you need to file a complaint with your electric supply company and request them to replace the transformer to stabilize the voltage. However, be aware that they often won’t take action unless you pay them a bribe-we paid 15,000 Rs. to get ours replaced. First, I would advise you to adjust your AC overvoltage setting to 260V. This may help.
Sir thank you so much for your detail reply and explaining the whole situation this is what exactly happening in Pakistan you are 100% right and once again thank you so much, love and respect for your detail reply.❤️❤️❤️❤️❤️❤️❤️❤️❤️🥰🥰🥰🥰❤️❤️
@@CityHappyFamily Pleasure is all mine, brother. Stay safe.
@@fahadsaudia ❤️❤️❤️❤️❤️❤️
masha allah bachche bohat cute hain
Jazakallah bro, ❤️❤️❤️❤️❤️❤️
install mora or tomzen voltage protector on main lain it will protect your inverter also, max voltage should be 255 low is 180.
2500 lag jangy par 4lack ka inverter safe hojayga, inverter may apna protector hota hai par safty k liya lagana zarori hota hai bohot
G wu tu thek hy lakin abi masla yay hy grid light fluctuate kr rhy hy 110 sy 270 volts ky drmian 2 din sy. Wapda kutch nhe kr rha . Iska koe siltion nhe mill rha
❤❤ماشاءاللہ ماشاءاللہ ❤❤❤
❤️❤️❤️❤️❤️❤️❤️
بھائی۔ inverex nitox کے 6kw کے انورٹر کی Rated output power = 6kw ہے۔ لیکن Maximum output power 6.6kw ہے۔ اور ایکچوئل آؤٹ پٹ rated آؤٹ پٹ سے زیادہ ممکن ہے۔ میں نے ابھی انٹرنیٹ سے اس انورٹر کی ڈیٹا شیٹ کی pdf دیکھی۔ اس میں maximum آؤٹ پٹ 6600 واٹ بتائی گئی ہے۔ سولر پینل میں بھی ایسا ہوتا ہے کہ rated power 585w والا سولر پینل آئیڈیل روشنی، ٹمپریچر اور موسم میں 585 واٹ سے بھی زیادہ آؤٹ پٹ دے دیتا ہے۔ یہ میرا ذاتی تجربہ ہے۔ اور سولر پینل میوزیکچرر بھی یہی کہتے ہیں۔
جی ایسا ہی لگ رہا ہے لیکن وہ مسئلہ نہیں ہے یہاں پہ مسئلہ واپڈا کا جو گرڈ ہے نا وہاں سے وولٹیج فلکچویٹ ہو رہے ہیں بیسیکلی جس کی وجہ سے انورٹر بار بار ٹرپ ہو رہا ہے۔
1 pannel kam ker dain 40 sae 45 volt theek ho jaye ga
overall app kae 12 ziyada hae
G good ho gya sir
Mashallah happy family
❤️❤️❤️❤️❤️❤️❤️❤️❤️🥰
Sir 6.5 is ok no worries. Pv volts bass 450vdc se ziyada nhi jaein
Ok, thanks
Ksi or phase ko chk kreain jis phase py voltage kam hn us phase py inverter ko connect krein
Sir wapda ky transformer mein masla hy lakin wu log maan nhe rhay buht ziada voltage fluctuate kr rhay hein
Parrots rakh lien maghar temperature control krna bhi zroori hota hai aur metal cages ka pv stand ky metal ko touch na kry
Ok, thank you ❤️❤️❤️❤️
Temperature will be higher than birds survive under PV shade ....
@@Waqasaslam98 Yes that is valid point, will avoid that.
Transfmer ji Main Tar jo uper sy aa rhi hoti ha wo jil jy tovada hota ua high volt aty hn yey msla hmry pass hr Month msla bnta ha
G transformer ka he masla hy G, 2 din hone ko hein wapda apni mrzi sy he sehe kre ga
PV hight volt ki wjha sy bnd hva hai ya Grid high voltage ky liye ..... Aghar to grid sy aa rhy to volt/amp protection lga sakty hn usmy low aur high dono ky grid voltage set kr sakty hn us range sy upar ya jeechy jaien to grid ko woh switch khudi off kr deta hai
Ok , thank you ❤️❤️❤️❤️
Your DC side is ok don't do anything from Dc side. Just install tomzn voltage protector from AC side buy original from Daraz.
Sir tripping band nhe ho rhi
@@CityHappyFamily Jub tak Grid k voltage stable nahi hun gay tripping band nahi ho gi, Grid voltage kya aa rahay
@@zulfiqaryaqoob fluctuate ho rhay hein continuously 110 sy 270 tak.
@@CityHappyFamily tenoo phase? baki k 2 phase b check kern
@@zulfiqaryaqoob ok
Ap ke Ghar kheer bht bati hai mashaallah
G sb loog buht shouq sy khaty hein . Without any dry fruits
Bhai apki video dekhi. Pv voltage high tb hoty hein jb panels ziada lgaye hon. Apk 6,6 panel hein per string it's not an issue. It goes up to 6.5 due to barish k bad asman se dust particles clear ho jaty hein light ki density clear hony se panels max create kr jaty kisi time. Grid voltage b isi wja se high hoty. Jb ek area me ziada log peak feeding krny lgty hein due to clear weather, grid voltage get high. Today i felt that too in my solar system. Voltage protection lgwa lein kch khas frk nahi pry ga bs inverter tk high voltage ni ja paye ga. Trip ab b ho rha hai tb b hoga. Mera system b grid voltage high ki warning deta hai but 254 se up nahi jaty mery.
جی شکریہ بھائی جان بہت شکریہ اپ کی بات بالکل ٹھیک ہے ایسا ہی ہے ایس پی ڈیز لگانے سے انورٹر تک نہیں پہنچے گا لیکن ٹرپ تو ہونا ہی ہے جی 100 پرسنٹ ٹیکنیکلی اپ کی بات ٹھیک ہے۔
@@CityHappyFamily bro spd nahi voltage protector ki bat kr rha me. Spd to bs tb trigger hoti hai jb extremely high voltage aa jyen. In case wapda side pe wire sath jurr jye
@@talalakram7 ok
AC voltage 265V tak ker dein settings mein se. Phir trip nahi Hoga
Lakin wu high nhe hy kise chese ko koe nuqsaan tu nhe hoga
Cloudy mosam me high voltage ka masala ata hai. Kabi sorj ki roshni Hoti ha or kabi badal jes ki waja se panel high voltage create krte hai. Es k ky aap volt protection device lagay.
G buht acha , brother
use stabilizer with your wapda same issue with me but in my case voltages are low from wapda
G thek hy ussay masla hall ho ja3 ga
@@CityHappyFamily yes same system installed in my house after attaching 5kv stablizer to wapda issue resolved
@@earnonline786 how much that stabilizer costed you ??
@@CityHappyFamily if you go for local then 50k to 55k but i purchase imported which cost me 70k and very fast and reliable.
Ok thnx
Bhi g green meter app nsi konsa lagaya hai, Ami or old
Old one bro
Jab sa basrihein start howi hamarey wapda k voltage bhi 250,260 tak jaa rahein hain mere khayal sa chon k load nahi hota hai transformer pr mosam ki thandk ki waja
G aisa he hy kafi problems aa rhay hein inverter pr iski waja sy buhat ziada tripping ho thi hy
Chat pe kabooter rakh sakatey hain Desi totay bhi aor murghiyan bhi Lakin African totay aor Australian ke liye aap air coolar lagana parega GA mere Kafi totay es liyie Mar ghayeke hymen Pata nahi chala aor coolar ka panic wala pump band Tha.
Acha g , iska matlab wu garmi bardasht nhe krein gy
@@CityHappyFamily ji bilkul apney bachoon se zayada khayal rakha hoga Garmin aor sardi ka.
@@ilyasali8502 G aisa he hy, chalein dekhtein hei . Humein ti idea nhe hy koe iska
Bhai opr parrots garmi mein expire ho jayein gy..Solar panels k nechy garmi bohaat ziyada ho jati hy...ap nechy waley portion mein jahan plants rakhy hein wahan pr cages bnwa leinn wahan theek rahein gy
Thank you so much for your valuable advice ❤️❤️❤️❤️❤️
Bhai ac side pe jo inverter ko ac input di hai wahan volt protector lagyen.
G thek hy brother, thank you so much ❤️❤️❤️
Hmry pass wapda apni mrzinh krta itna zeyda hr shaka sy calo krvaty hn Madia Reporter sy call krvaty hn 4 5 hour mn aa jaty hn khud kbi nh ayn gy
G aisa he hy, mulk ky halay Allah he behtar janta hy kia hein
Pv ka aik breaker off kar dian karen
Ussy be kutch nhe ho rha, abi masla yay hy grid light fluctuate kr rhy hy 110 sy 270 volts ky drmian 2 din sy. Wapda kutch nhe kr rha . Iska koe siltion nhe mill rha
@CityHappyFamily
All three pase pa voltage check kare.
Ground and neutral ke voltage bhe check karen, baz dafa neutral ma voltage aye rahe hoti ha 60v sa oper ground neutral ke voltage ho tu inverter nahe chalta.
Wapda ko complain karni parti ha ka transformer ke earting theek karen phir masla hal hota ha
@@sohaib.s1573 G complaint kr ky be masla thek nhe hota bro 2 din ho gye hein complaint k9 abi tk rabta nhe ho ska
@CityHappyFamily apna transformer ka earthing bore kara daen khud, 20ft bore chemical ke 3 bori 5kg wale iron pati 2inch wale 20ft, phir wapda line man sa kahen earting connect kara da.
Masla hal ho gye ga
@@sohaib.s1573 haan yay b acha idea hy
Sir ap ka system neem hakeem ny lgya he ji mujhy samjh ae he. Me ny 2016 me 1st system lgya tha jb log mazaq krty thy. Jan roshni achi ho to 1 plate 50vdc tak b chali jati he. Barsih k bad mosam saaf ho jata he. Ap ko yehi masla march me b ae ga. 10 panals 1 sting me hony chaye thy .nitrox best 380vdc se 400vdc p kaam krta he. Yehi baat jab ap kisi b lagany wali installer se bolein gye wo kahy ga hame pata he ya use. Laken 95% logo ko is kaam ki samjh nahi .
Bro mostly solar ky ander neem hakeem he hein, muje tu abi tk professional log nhe mile shayed bre cities mein hon yu pata nhe
Lakin asal.masla wapda ka hy, unky transformer ki mrzi jitna volt dena chahe
Ji han wo b hamara ek masla hota he. Laken 180 volt tak be app ki reversing band nahi hoti. 150 140 tak drop ho jae to system trip krta he... us ka haal ye he k apna phase change krwa k dekh lein. Some time 1 phase bohat kam or 2 sahi hoty hen.
@@shahzaibyounass3974 haan ji wu masla ho jata hy kabi knar lakin iss dfa yay masla nhe tha.
Aap Mora ki Voltage device lagwai, Aur us mai setting karday high and low voltage set karday. Inverter khud trip kar jai ga aur koi loss nhai hoga.
Kahan sy mile ga original wala. Yahan tu 2 number be nhe 10 number chesen mill rhi hein iswaqat
Ap kis area me hain? @@CityHappyFamily
@@talalakram7 under mepco
@@talalakram7 Mian Channu
@@CityHappyFamilyor mein apko lahore ka samjhta rha aj tk, by the way i am from Multan ❤
Ab ap ka masla resolve hogia ha kia?
Not yet aaj be off hy inverter, due to light fluctuating, complaint ki hy lakin koe pata nhe kb masla hall ho
same problem mery gher main .mera 8kw hy laken 9.30kw aa rhy thy
main nay app ko phaly bhi masg kiya tha.yah problem aa rahi.
Pata nhe aisa kuin hy
Mere pass abi aaj sy aana start huwa hy
main nay yah setup lahore say lagwaya hy .waha 5.6 ghero main asa hi problem hy.yah double glass ki waja say hy .sab log yahi bol rahy
@@starshipteck acha yay 1 new theory aa gye hy abb
Bhai umeed krta ap khairyat sy hongy. Mjhe Apne ghr ma ac lgwana Mjhe bilkul smjh nai arhi Konsa lgwao..13 by 13 room size hai or 14 feet pay Ghar ki roof hai.. ird gird Kahi sy direct dhoop Nahi ati
Bro apna budget , aur choice ko zehn mein rkhty huwe koe b ac lay lo ju criteria pr pora utrta hon , Haier, Gree, TCL, Midea,etc
@@CityHappyFamily 1 ton ma konsa full dc behtr rhyga plus 1.5 ton ma bhi bta dein. AP k mutabik.
@@ubaidwaheed9252 1 ton na lein aapka room size bra hy 1.5 ton ka inmein sy koe b lein lein
@@CityHappyFamily gree ma ap Konsa model recommend krygy... Jo full DC ho
@@ubaidwaheed9252 bro yhora aap market search kro, latest model mill jae ga aapko
Salam o alaikum brother aik tu aap ko spd laga I pregi alag se earthing ke sat dosri aap ko aik DC earthing lagwani parengi algag se jehaan tak panels ke vol ka MASALA Hai tu aap Un ke sirf open circuit volt laga sakatey hain jitni inverter kihad hai short circuit nahi kion ke beshak solar panel 570 watt ka he ho wo us sey kahan zayada bijli Ana sakta hai jasey marey pass aik 150 watt ka solar panel Hai Lakin wo 180watt banata Hai peak waqat men ye sab solar ke sath likha howa bhi hota. Hai.
W.salam, G aapki baat thek hy. Krta hon kutch iska
Sir i live close by, same issue mery inverter mein bhi hua tha but PV breaker 63A Tomzn ka lga hua hy wo trip kr gya.
Wapda high voltage issue k liay phase change krwa den jis pr sb sy kam voltage hain us pr set kr den.
G aisa he krna pre ga
Aap kahan sy hein
After rain sometime this issue happens because the debris in the air settles and sunlight hits the solar directly.
@@najamulhassan1962 yes true
@@CityHappyFamily I’m from Vehari sir.
Bhai voltage protection device lagwao and pv voltage ka koi issue nhi sab jhoot bolta hann
Ok, thank you 🙏🙏
I think betry lagany say masla hal ho jaye ga
Nhe battery ka issue nhe hy ussy backup mile ga aur kutch nhe
Apka hybrid inverter hai?@@CityHappyFamily
@@samilegend4362 yes
Yehi problem mert sath hay vayron 2 6kw
Acha phir thek huwa aapka masla
Bhai ap ky pv volt theek han koi issue nahe hai, jab ap ky wapda ki voltage high aa rahe hai tou ap ku inverter ky voltage wapda ky voltage se kam han match nahe ker rahe, es leya tripping g howe hai, aur wapda py volte protection devise lagain. Jo inverter kohigh voltage se safe rakhay ge.aurjab tak 240vte py normal voltage nahe ho ge yeh devise ap ky inverter ko wapda se connect nahe honay dy ge. Aur apky gher ka load chalta rahe ga. Mai nay apnay lal walay inverter py 575 watt ki 7 aur 280 watt wali 8 modules lagaye howay han. 280 watt ky panels 39.5 volt aur 575 watt walay panels ki 52 volte banaty han, 575 walay 336 volte aur 280 walay 275 volte dytey han. Total volt 611 hotey han per bina kise problem ky chal raha hai. Tou pv volt kise ky high howay
Ok, brother very good advice. Thank you so much ❤️❤️❤️❤️❤️❤️
Use time delay protection
Ok, but tripping sy kaisay bachein
@@CityHappyFamily only time delay can help you from tripping search the benefits of time delay protection device your problem will solve
Best of luck 👍
@@MarkPrince1317 ok, that is something new to me
Birds na rakhay, Aapkay Panels bi Facial hai to ye dono side say kaam kartay hai, Heat Reflect hoti hai is mai. Aur Birds bohat nazuq hotay hai aap birds ko room mai rakhhay ya big size ka cage design karwai.
G aapki baat mein buhat wazan hy, thanks brother
@@CityHappyFamily Welcome Bhai
❤️❤️❤️❤️
Apne solar panel k frame ka detail tour krwao
Ok
گرمی بہت زیادہ ھو جائے گی گلاس کی وجہ سے
G yay tu hy
Birds k liye sai nai rahy ga, Q plates sun light se heat absorb kr k bohht bura affect create krti hn or birds wese hi boht sensitive hoty hn
Thek hy bro, isse liyie aap sb ki rehnumae ki thi
Earthing karwa lo
G thek ho gya
Asalamoalaikum Atif bhai
w.salam
😋😋😋😋😋😋😋😋😋😋😋😋
❤️❤️❤️❤️❤️❤️❤️❤️
Sir khariat hy, pakistan mein tou maslu masael he hein. Masailistan he hy Pakistan waisay. Koe na koe masla bna he rehta hy ju mrzi kr lein aap
@@CityHappyFamily I love Pakistan but i really hate the administration.Maamooli masail insay hall nai hou rahay....Kehtay hein keh F.A.Paas karo tay fauj vich bharti houndi a...Menu tay eh saalay Primary paas vi nai lagday...........
@@user-de5zy3el7g 😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂
Economics ki kitabein bhari pari hein keh POPULATION can be a Great Asset...Inhan kolon munday E sambhalay nai jaanday,Kia dassan yaar,Fer likhan tay koi chapar kanatiya fon karda A...Tenoon asein chadna nai...Oye maan day denio,Jay tuhanoo kujh nai aanda tay koi dassay vi naan ?
Asalamoalaikum Atif bai
W.salam
Ap ne voltage protection relay nai lagai?
Nhe, mera installer ny mana kia tha ky already inverter ky ander moujoud hoty hein Spds , double kuin lganay hein. Iski setting mein hy ky aap voltage define kr dein inverter uss setting pr trip krwa deta hy light ko
@@CityHappyFamily sai, mein ne hifz e mataqdumm lagwai hui hy
@@Kamran bro double lganay sy problems he aaty hein aapko pata he hy Pakistan mein breakers aur yay spds kis level ki aati hein
@@CityHappyFamily ye baat ho hy wese, khair ab lag gye daikhty hn kb tk chalty hn
@@Kamran G aisa he hy
Fist floor pere bna lan🦃🦃🦃
G thek hy, Jazakallah ❤️
Aap ki solar production barhi hey aur aap KY panels bificial hain zaroor bificial gain Ho raha hey kaun aisy inverter ky sath bificial panel nahi lagany chahy
Ok ,g
Earthing kurvai hai?
Not yet
Neutral ki wire lose honay sai fluctuation hoti hai zada tur transformer ki earth lose ho tou hoti hai ya apki Neutral pol sai lose ho tub bhi... and agur ac earthing hoi ho tou wo esko cover kur leta hai
@@mrbjazzify May be that is 1 of the reason
Sir battery installation karo
Ussay grid ki voltage kaisay control hogi
Ussay grid band kr ky ghar chal jae ga waisay lakin grid feeding nhe hogi phir
Battery installation se kia yeh masala hal hoga ??
@@zamankhan9285 This is not batteries issue. It is die to wapda transformer problem.
@@CityHappyFamily battery se aapka inverter shutdown Nahin hoga.
Asalamoalaikum Atif bhai
W.salam ❤️❤️❤️❤️
Bhai me Saad baig bat kr rha hu
Kesy hain app log
@@AbdullahBaig-y3z Alhamdulillah thek thaak
@@AbdullahBaig-y3z Welcome bro, G muje idea ho gya tha.