HVAC: How To Test a Single Phase Compressor & Check For Any Grounds (Insulation Resistance) Ohm Test

Sdílet
Vložit
  • čas přidán 1. 06. 2024
  • How to check a compressor for any grounds
    How to check the windings of a single phase compressor
    How to check resistance of a single phase compressor
    How to ohm out a compressor
    How to read ohms on a compressor
    How to check the windings of a refrigeration compressor
    How to test for bad compressor. Ohms test with multimeter
    Troubleshoot a grounded (Shorted to ground) compressor
    How to test a compressor - HVAC
    How to test a refrigeration compressor
    How to troubleshoot a 3 phase compressor using a muli-meter
    How to check the windings of a 3 phase compressor
    How to check resistance of a 3 phase compressor
    Single phase vs three phase
    Fluke 902 FC HVAC True-RMS Clamp Meter
    amzn.to/39wvwiK
    Veto Pro Pac TECH-LC Tool Bag
    amzn.to/3qbmIWg
    hvac,hvacr,ac,3 phase compressor troubleshooting,3 phase compressor,3 phase,resistance,ohms,how to check 3 phase compressor,how to check 3 phase compressor windings,how to check compressor hvac,how to check compressor on refrigerator,how to check compressor for,how to check for bad compressor hvac,how to check resistance on compressor,how to ohm out a compressor,how to check for a grounded compressor,how to test 3 phase compressor winding,3 phase compressor testing
    Thanks for watching!
    Email: Jumpermantech@Gmail.com
    Follow me on instagram! @JumpRmantech
  • Věda a technologie

Komentáře • 101

  • @Ferreira-qq9cd
    @Ferreira-qq9cd Před 2 měsíci +3

    OMG the way you explain it is amazing. Specially, with someone with dyslexia that makes my job so hard you just made it so easy explain it. Thank you.

  • @professormantle7959
    @professormantle7959 Před 3 měsíci +2

    You are so clear and audible. So clear and not too fast not too slow. Perfect. Thanks, so helpful

  • @haroldseals5935
    @haroldseals5935 Před rokem +9

    This is by far one of the best explained videos on troubleshooting compressors posted period! What a great reference. Thanks so much.

  • @BraveToasterStrudel
    @BraveToasterStrudel Před 2 měsíci

    Blessed to have you making videos man. You have been an incredible resource for me learning this trade.

  • @zartalks
    @zartalks Před 5 měsíci +1

    Super helpful video ....and its easy to understand when we know what to look for and what not to look for ...thanks a lot

  • @davonetoney475
    @davonetoney475 Před 2 měsíci

    You made your explanation clear and simple.

  • @flexortiz92
    @flexortiz92 Před 3 lety +2

    I’m ballin like an athlete but got no Jumpa! Jumper man tech back at it again good shit bro

    • @JumpermanTech
      @JumpermanTech  Před 3 lety

      Lmaoooo thank you bro! Stay safe out there & stay tuned for new videos every week🔧

  • @roberts1159
    @roberts1159 Před 3 lety +1

    Nice job explaining this. Makes sense that run to start would equal two common to run and start since resistors in series are equal to the total.

  • @takatastore6338
    @takatastore6338 Před rokem +7

    Your videos are so valuable it's crazy....I just started in the industry and I have been learning so much from your videos... thank you very much for your time and work

  • @Mex710
    @Mex710 Před měsícem

    Thanks for that great explanation

  • @kitwahlai236
    @kitwahlai236 Před 2 měsíci

    Very clear instructions. Thanks. Allow me a little comment, the running coil should be of higher ohm(thin wiring). Starting coil is thicker wiring and thus, lower ohms.

  • @DrKay-kt8oz
    @DrKay-kt8oz Před 8 měsíci +1

    Greatest video on the subject matter.

  • @gotchaplumber
    @gotchaplumber Před 20 dny

    Great explanation.

  • @vesiwiw6
    @vesiwiw6 Před 8 měsíci

    Outstanding video - you have great knowledge of the subject and explain it clearly. Thank you

  • @stinkyvonfishstix4196
    @stinkyvonfishstix4196 Před 7 měsíci

    your above and behold. keep it up, your teaching

  • @johndaniels5407
    @johndaniels5407 Před 8 měsíci

    Excellent video 🎉 Thank you for sharing 🙏🏾

  • @refrigerationconfidential4376

    This is a great video for troubleshooting for a compressor to verify if it’s good 👍🏽

    • @JumpermanTech
      @JumpermanTech  Před 3 lety

      My guy!!! Thank you! Appreciate your feedback very much🙏 If anyone is reading this, check out his channel "Refrigeration Confidential" for some great content! Much love🙏✌

  • @bettalinks
    @bettalinks Před měsícem

    Perfectly executed thank you for your knowledge

  • @calebmcauley9220
    @calebmcauley9220 Před 2 měsíci

    Excellent video 👍

  • @MustangWes
    @MustangWes Před 7 měsíci

    Great information well put together. Professional video easy to understand.

  • @duongduong1387
    @duongduong1387 Před 18 dny

    Supper supper helpful. Thank you very much.

  • @cambullterrier4148
    @cambullterrier4148 Před 2 měsíci

    This is good man, for a layman like myself! nice!😎

  • @user-fw1io3ys7x
    @user-fw1io3ys7x Před 3 měsíci

    Great man - keep it going amazing explanations with detail

  • @Goodfella0982
    @Goodfella0982 Před 9 měsíci

    You are the best at explaining any of this, very clear and concise!! My salute to you bro!

  • @izzybell11
    @izzybell11 Před 3 lety +3

    Informative, interesting and helpful video. Great job JMT. ⭐️⭐️⭐️⭐️⭐️⭐️⭐️⭐️⭐️⭐️

    • @JumpermanTech
      @JumpermanTech  Před 3 lety

      Thank you thank you! ⭐⭐⭐Stay safe out there & stay tuned for new videos every week🔧

    • @khaoticman3055
      @khaoticman3055 Před 2 lety

      @@JumpermanTech yo i got a question what do u mean when u say your grounded when checking the restistance of the compressor?

    • @jollyscaria1922
      @jollyscaria1922 Před 7 měsíci

      Seldcomprssor terminals c .s and Rare identified by measuringrheresitance ohms between the terminals usingmultimeter or clamp meter the resistance of ruing winding is low while thatofstarting windingis high when the multimeter pords are connected to twrminal R and c resistance of ruing windingor the low est resistance is indicated whwnthe connected to terminals c r and s total resistance of both qinding is indicatwd when the terminala c and s are connected to the meter the resistance of starting winding is indicated or the value willbe bet ween the abovetwo rhe high est resistace ind icated bet wen r cthe resustancc and sthes two sum of resistance of ruing betweenr and c and starting windingbwtqeen c and s is to r and s hight expls 1.2 50 2.3 30 .1.3 20 lowesr 1.2 rs 2 3 cs 1 3 r 1 r 2 s 3 c hight reding 50 medom 30 low 20 low est restnc rc highest r s 13 lowes

  • @jd5787
    @jd5787 Před rokem

    Best. Explanation. Ever. Thanks! So my compressor is good, there are no shorts BUT it is not cooling... What gives if it not the relay then? Too much gas topped up last time? (I noticed the compressor was running very hot). Its a wine fridge so not as complex as a fridge/freezer...

  • @btd1993
    @btd1993 Před 3 měsíci

    super informative! thanks for sharing

  • @David-hj6if
    @David-hj6if Před 11 měsíci

    Very easy to follow instructions. Made perfect sense. Thanks, keep up the good work.

  • @alexeytech1495
    @alexeytech1495 Před 3 lety +2

    Well explained material. Well done job.

    • @JumpermanTech
      @JumpermanTech  Před 3 lety

      Thank you! Much appreciation🙏🙏🙏Stay safe out there & stay tuned for new videos every week🔧

  • @kennethlobo4420
    @kennethlobo4420 Před 2 lety

    Great explanation

  • @jollyscaria1922
    @jollyscaria1922 Před 4 měsíci

    Thankyou gues welcomed

  • @belayrebi8415
    @belayrebi8415 Před měsícem

    Really good really good thank you

  • @alfredfu7052
    @alfredfu7052 Před rokem

    It helped. Thanks a bunch

  • @beemikeme
    @beemikeme Před rokem +2

    What is the ohm readings from C - R & C- S do NOT add up to the reading R - S?

  • @rolandubaldo3965
    @rolandubaldo3965 Před 6 měsíci

    Thank you you save me a lot of money

  • @neilvestervictor180
    @neilvestervictor180 Před 3 lety +2

    great explanations

  • @chicocash9668
    @chicocash9668 Před 3 měsíci

    good info thanks

  • @shamsheralam8862
    @shamsheralam8862 Před rokem

    Very clear thanks

  • @kensmith1104
    @kensmith1104 Před 4 měsíci +1

    Thanks a lot, very helpful

    • @JumpermanTech
      @JumpermanTech  Před 4 měsíci

      Thank you! Stay tuned for new videos every week🔧⚡️

  • @isaacaugustine2364
    @isaacaugustine2364 Před 11 měsíci

    Thanks for sharing

  • @yonastesfaye699
    @yonastesfaye699 Před 5 měsíci

    Thank you

  • @ld7103
    @ld7103 Před 2 lety +1

    Great video but does that meter go to 1 M ohm? Just my understanding u require that scale to do the insulation test?

  • @luisloks
    @luisloks Před rokem +2

    Common and run show a reading of .6 while the left side show 8.6.
    Making a total of 9 Which sounds good.
    But is that .6 reading maybe too low indicating a worn out compressor?

  • @FatBoy7.3Powerstroke
    @FatBoy7.3Powerstroke Před 8 měsíci

    Excellent..!!

  • @fariesmech
    @fariesmech Před 3 lety

    What is the shell temperature allowed for compressor

  • @yayapagaming425
    @yayapagaming425 Před 3 lety +2

    Good job brother

    • @JumpermanTech
      @JumpermanTech  Před 3 lety

      Thank you very much bro🙏 Thank you for watching🙂Stay safe out there & stay tuned for new videos every week🔧

  • @josselindesir5409
    @josselindesir5409 Před 9 měsíci

    Goooooood job man

  • @mralizebkhan
    @mralizebkhan Před 9 měsíci

    Nice video

  • @mtbbiker6401
    @mtbbiker6401 Před 10 měsíci

    Great video. thanks. If you have a ground short or OL when checking resistance, may the compressor still run or do you only perform these tests if the compressor won't run?

    • @jollyscaria1922
      @jollyscaria1922 Před 4 měsíci

      Diffrant reding conunivet showing good runig starting point como n low restisans ok

  • @paulb9769
    @paulb9769 Před 10 měsíci

    Hi could you please explain something to me. I have just seen a video where it is stated that a PTC is connected to the compressor and not a BiMetal cut out. Surely it can not be a PTC?

  • @wadoodmohd1870
    @wadoodmohd1870 Před měsícem

    thanks

  • @rocker8692
    @rocker8692 Před měsícem

    I have a question,can you have all the winding check out good,but still inside the compressor it can be mechanically brokin inside?

  • @jvm3753
    @jvm3753 Před 9 měsíci

    Really enjoyed the video. I have a chest freezer; stopped working, but caught in time to save the food.
    Did the resistance check on compressor; all checked good. Overtemp switch, checked good. Relay checked good. I replaced the overtemp switch & relay; still won't work. Could the compressor be stuck? If so, how can I prove that?
    Thank you.

    • @jollyscaria1922
      @jollyscaria1922 Před 4 měsíci

      Vrey good gueshering gues all best welcomed gues thanyou gor allgues shering gues guied allgues thkyou somuch ..

  • @darwingarcia8491
    @darwingarcia8491 Před rokem

    What if the compressor still had refrigerant charge is there difference in reading?

  • @deddie4645
    @deddie4645 Před 19 dny

    Nice

  • @user-ff8ds3ce2t
    @user-ff8ds3ce2t Před 3 měsíci

    What if the leadings are high in resistance when checking windings like cs- 35.6, cr-22, sr59.9

  • @nnaemekaiwuozor8972
    @nnaemekaiwuozor8972 Před 11 měsíci

    This is good

  • @w.manders2817
    @w.manders2817 Před měsícem

    in other videos it is said the Ohm's between the 3 should be more or less the same, instead of the top 2 = the bottom 2, why is that?

  • @shalehinshaari2878
    @shalehinshaari2878 Před 3 lety +2

    Great video. How about 3phase compressor? Thanks

    • @JumpermanTech
      @JumpermanTech  Před 3 lety +1

      Thank you very much! I made a video on 3 phase compressors too👍 Heres a link🙂
      czcams.com/video/1ja1GkLWrwc/video.html

  • @JacksonJoy-vc3lv
    @JacksonJoy-vc3lv Před 11 měsíci

    Thanks bro I did that on my R600 c/s give me 2 and the c/m give 2 and with the conclusion of the s/m gives 4 it’s a good compressor 😢

  • @faphosy38
    @faphosy38 Před 9 měsíci

    YOU JUST SAVE ME $2k.THANKS

  • @brianmuthomi9594
    @brianmuthomi9594 Před 8 měsíci

    What causes running winding to read higher resistance than star winding

  • @wannabeelektwicityman268
    @wannabeelektwicityman268 Před měsícem

    Does it make any sense that my windings ohm out correctly but are shorted to ground?

  • @okotcharles5016
    @okotcharles5016 Před 2 lety

    I got compressor changed run cap but was only harm not starting

  • @MiguelGutierrez-gv3yy
    @MiguelGutierrez-gv3yy Před 2 lety

    What if your C to S is the lower than your C to R?

  • @liquidmocofilmsllc4915
    @liquidmocofilmsllc4915 Před 2 lety +1

    I can't find any videos on MECHANICAL FAILURES of a compressor. I have a compressor that the windings are fine but makes a ugly loud noise at start up and then trips the breaker. Anyone know of a good video to check for mechanical failures?

    • @JumpermanTech
      @JumpermanTech  Před 2 lety

      I have many troubleshooting videos on my channel so subscribe for new videos every week! Sounds like locked rotor on the compressor. Check the compressor specs for LRA. Locked rotor amps. Upon startup, check amps on the compressor and if it's really high and matches the LRA versus the RLA (Running load amps) then you have locked rotor and the compressor needs to be replaced. Before determining that, make sure your start/run capacitors are good. If the caps are good, your compressor is bad and needs to be replaced. If the capacitors are bad, replace them and see what happens. Most likely will solve your issue. Thank me later 😅

  • @kevinbergen1565
    @kevinbergen1565 Před 3 měsíci

    So for a Samsung Compressor with the S-C-R scheme, I get readings of S-C 7.2 ohms, C-R 7.5 ohms, R-S 7.2 ohms but none went ground to copper. Is my compressor good or bad? One more note, the compressor- MKV190CL2B is label rated as 240VAC 3 P- Huh? I'm only providing residential from-the-wall 120VAC. How can it work?

    • @PuddinJr1993
      @PuddinJr1993 Před 2 měsíci

      It is 3 phase, the 3 phase is created by a pulse width module signal from the inverter control board that converts single phase to 3 phase.
      In the Appliance tech world we see more dead inverters dead then compressors on Samsung units.

  • @HVACRDUDE
    @HVACRDUDE Před 3 lety +1

    I'll usually run a sj cord from the vans battery to ground on the door frame into the unit. If I 1890kohmsufs to frame from van it's a working canuuter oscillator

  • @TheWpruden
    @TheWpruden Před 2 lety +1

    Nice video
    However when checking for shorts a megommeter should be used.

    • @JumpermanTech
      @JumpermanTech  Před 2 lety

      Thank you! A megohmmeter is definitely the best to use 💯 Need to make use of what you have though. Thanks for watching! Stay tuned for new videos every week🔧

  • @alvincee7605
    @alvincee7605 Před měsícem

    ❤❤❤

  • @darwingarcia8491
    @darwingarcia8491 Před rokem

    Christal clear

  • @Sroor2023
    @Sroor2023 Před rokem +1

    So I’ve checked if I got 1.2 , 3.1 and 3.8 so is the compressor ok ?

    • @stefanschuster8971
      @stefanschuster8971 Před rokem

      I got 2.5 run 3.5 start and 4.8 5 .5 for run + start

    • @stefanschuster8971
      @stefanschuster8971 Před rokem

      Unit ran for 1 second and would shut off . Got 50 amps when lra is 40. Chnaged cap , relay and tried a hard start. She wouldn't go. No high limit no lpco no continuity to ground... how would you finalize diagnostics. It would run when you bump started it as well but didn't seem to have too much power behind it .

    • @Sroor2023
      @Sroor2023 Před rokem

      Mine is ok I’ve just changed capacitor nothing else and it’s cool now

  • @nothingeverything6708

    What is that meaning open and close winding?

    • @louisdreyer7523
      @louisdreyer7523 Před 11 měsíci

      Two types of shorts can occur in a compressor motor, a turn-to-turn short within a winding or a winding-to-frame short. The reading obtained between the Run and Common, and the Start and Common pins should be within .5 ohm of each other. If these readings are significantly different, the winding with the significantly lower reading has a turn-to-turn short and the compressor needs to be replaced. Check for a winding-to-the-motor- frame short by taking a reading between each of the pins and the compressor housing. If the meter's LCD displays anything other than an "O.L." during these tests, the compressor is bad and needs to be replaced.

  • @matthewnaidoo8606
    @matthewnaidoo8606 Před 3 lety +2

    What if the number dont add up ?

    • @bherna10
      @bherna10 Před 2 lety +1

      That’s what I want to know

  • @nnaemekaiwuozor8972
    @nnaemekaiwuozor8972 Před 11 měsíci

    I had a compressor, when I connect it directly without the relay and overload it cuts the fuse.

  • @shadrackagyemang9740
    @shadrackagyemang9740 Před rokem

    Please what if the value of c-r=20.5, c-s=29.5 and s-r=50.5

    • @pedropiernas3616
      @pedropiernas3616 Před rokem

      means compressor seems good; check for isolation of the 3 pins now

  • @night_grinder1378
    @night_grinder1378 Před 14 dny

    What if S/C is OL
    If R/C is OL
    if S/R is 16 ohms

  • @Giovis1968
    @Giovis1968 Před 2 lety

    £13 on Amazon