  • How to check and change your Navien tankless water heater DIP switch settings and parameter settings. I wanted to get the most efficiency out of my Navien Water Heater. ** I’m not a plumber. Attempt these changes at your own risk. **

Komentáře • 81

  • @howardiko7156
    @howardiko7156 Před rokem +5

    Thanks so much I got more in 5 minutes of your video than the hours with the manual.

  • @robertmoldovan5931
    @robertmoldovan5931 Před rokem +2

    This guy actually know how to explain things. Thanks for the instruction..

  • @captaincoyote1792
    @captaincoyote1792 Před 2 lety +3

    Thank you, Jim, for this Navien video. While it didn’t answer to my issue (where the hell is that DIP switch? - I have an older 240a), I did learn something about my ten year old unit. BTW…..nice Porsche. I’m a long time owner of a 944, which is in winter-time mothballs right now. I’m already looking forward to spring! Take care!

    • @1nvisible1
      @1nvisible1 Před rokem

      Two seconds of notes that might be helpful
      Manual p45 dipswitch settings
      1-3= recirc (int vs ext)
      3 = intel preheating in "A" unit
      5 = well pump is on
      6 switch 9 off = sea level
      Programmming parameters p 64-68
      Turn off
      + x 3
      - x 3
      + x 4
      >1.TEC
      +x1
      >2.PAR
      i
      Preheat is 20, title 24 is 5
      p12
      +x12
      i
      >10 (flash)
      +/-
      i
      >wait
      reset (backs you out)
      power (off)

  • @awi1330
    @awi1330 Před 2 lety

    Good vid, helpful to see you go over it in real time

  • @realtoast7036
    @realtoast7036 Před rokem +1

    Thank you! I just had the 240A installed and need to get the intelligent pre-heat setup. The installer didn't know S and I would have had to cold-call around the area to find someone with familiarity with the system.

  • @Amazighi-NJ
    @Amazighi-NJ Před rokem +1

    Man!! You saved me from the scammers!! A plumber asked me to fix it for $700.00 I said no.
    I followed your explanation now my son can take a shower.
    May god bless you.
    Thank you very much !!!

  • @fernandoalcantar7907
    @fernandoalcantar7907 Před rokem

    Thank you!! This help me, plumbers also didn’t turn on the recirculating pump

  • @KevinMarshall-vk4sp
    @KevinMarshall-vk4sp Před 11 měsíci +20

    This was an exact replacement for the old one that lasted about 10 years. czcams.com/users/postUgkx7yWIKcrbA9KMHkGSfcgxW2lsjHT6B8Sh The top of my mitigation tube by my roofline was just a 90 elbow which allowed too much debris to fall down into the fan, eventually ruining it. Without this issue, I bet it would have kept running another 10 years. When I replaced this fan, I added an extra elbow joint so the top tube now it does a 180, which should solve that problem. The radon guys around here wanted to charge me a $300 diagnostic fee, then parts/labor (probably close to $600 total). I installed this all by myself in about an hour for the cost of the fan; it would probably be even easier/faster with two people. FYI the manufacturer's warranty greatly differs depending on whether you install it yourself (1 yr warranty) or have a licensed installer do it (10 yrs).

  • @broderp
    @broderp Před rokem

    I need to find my manual now. Good information.

  • @georgekabele640
    @georgekabele640 Před rokem

    Great video, thanks. I will be installing same boiler and I see that fresh air intake you didn’t take it from outside bud is just in your basement, is this ok? Thanks for your reply, take care.

  • @johnmcnally2227
    @johnmcnally2227 Před rokem +2

    Thanks for making this video. FYI it looks like Navien has eliminated the dip switches in the newer models. It's been replaced with the initial setup wizard.

  • @trevorhoward3328
    @trevorhoward3328 Před rokem

    Appreciate you making this

  • @donkaspar5336
    @donkaspar5336 Před 2 lety +2

    Great video Jim. No I’m confident to mess with my parameters.

  • @godfollower920
    @godfollower920 Před 9 měsíci

    Very very helpful. Thank you!

  • @CobraChamp
    @CobraChamp Před rokem

    Great video. Thanks!

  • @chanhducphung2826
    @chanhducphung2826 Před 2 lety

    Thank you for your video

  • @arunramalingam6280
    @arunramalingam6280 Před 2 lety

    can we connect to the system using the mobile app using wifi, do we need an adapter to connect using wifi ?

  • @AshleyC-vw7cu
    @AshleyC-vw7cu Před 6 měsíci

    Do you know which way the black two-way switch should be for internal recirculating? 9 o’clock or 6 o’clock?

  • @Schematics_38
    @Schematics_38 Před 6 měsíci

    I have the same tankless boiler there’s an option for the gpm are we supposed to set that? It’s at 0.0 right now

  • @davidg5629
    @davidg5629 Před 2 lety +1

    Hi. Is there a manifold for the circ pump (at the end point) or do you have a loop plumbed into your house? Not sure how the external loop works. Also, can you install PEX that close to a tankless unit? 18" linear for tanks. These things have really improved since the last one I installed. Great video, thanks. I'm sold.

  • @dshanahan99
    @dshanahan99 Před 2 lety +3

    Jim, I am pretty sure the internal and external recirc is in reference to the pumps, Internal will use the pump you have internal to the unit and will push water through the circ loop via that pump. External would be if you had an external pump connected to the pcb in the water heater. The "A" units come all ready to go with internal recirc you just need to flip up dip switch 1

    • @awnrc70
      @awnrc70 Před 2 lety +5

      wrong , if u set internal , it will circulate water only in the heater ,if external it will circulate in the loop in the house

  • @da1dada
    @da1dada Před rokem

    GF’s new place has this water heater. The GPM is at 0.0, which parameter is that?

  • @pk5786
    @pk5786 Před 2 měsíci

    Hi Jim, anything in this unit that needs to cleaned or replaced even if the unit is working good?

  • @Tazod41
    @Tazod41 Před rokem +1

    Did the intelligence setting actually work, and if it did how long do you feel it took to learn your usage? Was the 10 min preheat sufficient or did you have to change it back. I have a new 240a2 and just changed setting from always on where plumber left it to intelligent so we’ll see. Good video

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před rokem +1

      It’s working ok. We don’t have a steady pattern of hot water usage so it’s a little confused. My gas bill has gone way down. I did set the preheat time back to 20 minutes. Hope this helps.

  • @mooch91
    @mooch91 Před 4 měsíci

    That "well pump" setting is very vague - what does it do? I've always assumed it changes the control to better manage the pressure/flow swings associated with the well operation, but I've never really noticed much difference.

  • @vyacheslavshimunov609
    @vyacheslavshimunov609 Před 8 měsíci +1

    You the best 👍

  • @corymccarty6496
    @corymccarty6496 Před rokem

    How dp i adjust the temperature

  • @darrentoth7165
    @darrentoth7165 Před rokem

    Hey big Jim, looks like you utilized the recirculation with a return line, did you install an expansion tank and check valve on the cold water intake side? thanks :)

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před rokem +1

      No. The house was plumbed with the hot water loop.

    • @darrentoth7165
      @darrentoth7165 Před rokem

      @@bigjimsrealm4369 I am adding a hot water loop from the furthest bathroom and bringing that line straight back to the tankless heater and utilizing the built in recirc pump. Do I not need an expansion tank for my application? Thanks for the reply and great video!!!

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před rokem +1

      @@darrentoth7165 Don’t know. Probably need to ask a plumber. 😀

  • @myreviews4905
    @myreviews4905 Před rokem

    Does the external recirculation have a sensor to put on the most distant bathroom like The Grundfos or Watts Hot water recirculation pump? So you have instant hot water? Any issues with this unit?

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před rokem

      No remote sensor. It preheats the loop during times when you typically use hot water.

  • @thomasjefferson3552
    @thomasjefferson3552 Před rokem

    I have the npe-150s unit and it takes 3 minutes to heat my faucet water. Would this solution work for my model? My navien is in my bathroom so i dont think its a pipe distance issue i am having.

  • @arbtrader43
    @arbtrader43 Před 6 měsíci

    Hey Jim Have you stuck with the intelligent recirculation setting for a long while now? If so, how would you rate how intelligent it is? Any details appreciated ... thanks!

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před 6 měsíci

      I have had it on since I posted the video. I would give the intelligence 6/10. But we are retired and don’t have a set schedule and we have 2 units servicing the house. But I would give the gas savings a 10/10.

  • @danieljohnson2671
    @danieljohnson2671 Před 2 lety +1

    Hey Jim what version is your book. My version is a 1.0 (Feb.2021) and my book does not show the dip switches like yours on page 45. I am hooking up a brand new NPE-240A2 with the internal pump.

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před 2 lety

      My book is 5.4 Jan 2020. Also my unit is a 240A not a 240A2. Don’t know what the 2 means.

  • @dergibog27
    @dergibog27 Před 2 lety

    Would a recirculation valve be beneficial for this model?

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před 2 lety +1

      I’m guessing no. The unit has a recirculating pump in it. I don’t think any additional valves would be needed.

  • @valueStocks
    @valueStocks Před 2 lety

    My water takes forever to get warm. Is that what this pre heat is about. Keeps the lines warm?

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před 2 lety +1

      Yes, but your house has to be plumbed with a hot water loop. The water heater can be set to preheat the loop.

  • @kelbymorgan
    @kelbymorgan Před rokem

    I just had a 240S2(NG) installed. If I set the temperature at 120f, the kitchen tap reads 90f after running for 10 minutes. If I bump it up to 140f, the kitchen tap will read 110f after running 10 mins. Anything I should check? I have already power cycled it. Just looking for things to check before my plumber gets here later this week.
    Thanks,
    Kelby

    • @DBC-NC
      @DBC-NC Před rokem +1

      You are most likely loosing those degrees on the run between heater and fixture. If the water line between the two is accessible, try insulating it to maintain the temperature coming out of the water heater.

    • @kelbymorgan
      @kelbymorgan Před rokem

      @@DBC-NC thanks for the info Raymond. My plumber came by and it was a shower valve (showers not done yet) in my master bath allowing hot and cold to mix. Now the kitchen sink water will scald my hands!

  • @luisrgomez804
    @luisrgomez804 Před 2 lety

    Thank you, I’m having trouble with error codes and one is E438 is this sample fix or I need to change parts? Cay you help me?

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před 2 lety

      Sorry, I’m not familiar with the error codes.

    • @captaincoyote1792
      @captaincoyote1792 Před 2 lety

      @ Luis R Gomez good morning, . I’m dealing with my Navien and internal vs external circulation….and a “mildly disturbed” wife when there was no hot water for her shower!. Our unit is ten years old, I’m in western MA, and we’ve had extremely cold temps recently. I’m in my manual (I have a 240A model)….and I have two pages of error codes…but no code E438. I do have a E038….which signifies “Abnormal Circulation Pump, with three suggestions: (1) check circulation pump, (2) check water valve sensor, and (3) check cold water main. I hope this helps…..damn this technology.

    • @captaincoyote1792
      @captaincoyote1792 Před 2 lety

      Good morning, Luis….my reply above accidentally sent to Big Jim

  • @michaeldamico9592
    @michaeldamico9592 Před 2 lety

    I’m having one of these units installed in my house in a few weeks… trying to learn more about them…. But very hard to hear you in this video

  • @user-pt9gi3sl2c
    @user-pt9gi3sl2c Před 3 měsíci

    do you know where is the thermistor and how to change for this water heater

  • @Dbonecapo
    @Dbonecapo Před 5 měsíci

    Temp will not go up on my navien 240s only down, what can I do to raise the temperature?

  • @slbynum
    @slbynum Před 22 dny

    In the menu, there’s also intelligent mode. I guess I’m confused. Why is there intelligent mode on and off in the menu and also dip switch settings?

  • @silva0003
    @silva0003 Před 6 měsíci

    How do you increase PSI on this thing?

  • @ajnaprints
    @ajnaprints Před 2 lety +3

    Should be pulling combustion air from outside

  • @FORD150-5.4
    @FORD150-5.4 Před 8 měsíci

    140f is good settings for my house?

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před 8 měsíci +1

      120

    • @FORD150-5.4
      @FORD150-5.4 Před 8 měsíci

      @@bigjimsrealm4369 is very cold outside 20°

    • @FORD150-5.4
      @FORD150-5.4 Před 8 měsíci

      ​@@bigjimsrealm4369right now she is on 133f that perfect right I don't want to use too much gas is very cold outside

  • @Myoldiesrecordings
    @Myoldiesrecordings Před 2 lety

    Is there a video on just start up?

  • @kbabyblue
    @kbabyblue Před rokem

    I want to shutoff 1 area thats 1 room and is super hot
    Thermostat broke and I dont need that area
    So I can just stay with the house one

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před rokem

      If there is a valve to shut off that area, should be no problem. What is the set temp on the water heater?

  • @redeyewill100
    @redeyewill100 Před 2 lety

    Is 120 the max temperature?

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před 2 lety

      I’ve heard 140. Never seen anyone go that high. Usually people go 120 or 125.

    • @yingnyang2889
      @yingnyang2889 Před rokem

      @@bigjimsrealm4369 we had ours set at commercial setting (160 degs [8 yr warranty] vs 140deg setting residential temp - [15 yr warrant]). Been fine for a year. Then my kids said it was too hot this week (Jan 2023)?? I turned it down to 139 via the front panel, now it’s just luke warm can’t even make tea. AND the temp button stays at 139 and won’t go up. I’ll try your +++--++++ method

    • @bigjimsrealm4369
      @bigjimsrealm4369  Před rokem

      @@yingnyang2889 we leave ours at 120. It takes a few minutes to get the shower hot hot.

    • @PaulWyandt
      @PaulWyandt Před 5 měsíci

      We have the NPE-A2 and it allows temps 140-160 but you have to turn off the temp lock dip switch and enable commercial mode through the installer menu on the front panel. See manual p91.

  • @RS-cd9cf
    @RS-cd9cf Před 2 lety +1

    There is this weirdo guy Mikey Pipes up in New York who is a plumber and is also a registered Sx offender hates Navian and cries about them all the time

  • @zavie22
    @zavie22 Před 2 lety +1

    I guess you FAILED to read manufacturers manual it literally says do NOT put a 90 elbow directly on top of tankless lmao 🤣 amateurs