SOLARKIT - Deye inverter installation - a STEP-BY-STEP guide

Sdílet
Vložit
  • čas přidán 17. 12. 2023
  • We present the process step by step on how to commission a Deye inverter 📱🔧. Our aim is to help our partners to provide smooth installation experience to all customers.
    🤝 YOUR TRUSTWORTHY BUSINESS PARTNER TAILORED TO PERFECTION!
    - All essential components for a comprehensive solar system.
    - Official distributorship for esteemed brands such as Huawei, Deye, SolaX, Tongwei
    - Swift availability of globally recognized panel brands like Tongwei, Longi, Trina, Jinko, Risen with prompt international delivery.
    - Flexible payment terms to accommodate your financial preferences.
    - Benefit from loyalty rewarding discounts and promotions.
    - Access expert advice, training, and technical support for seamless commissioning and installation processes.
    Choose Solar Kit as your reliable partner, and let us tailor a solution that aligns perfectly with your requirements.

Komentáře • 7

  • @SiBex_ovh
    @SiBex_ovh Před měsícem

    6:25 best way is say it's a order of 3 phase like proper L1+L2+L3 or L1+L3+L2 what have impact on rotate direction of electric 3phase motors and everyone say... ohh Now I see, nice to have that.

  • @cybostampile4308
    @cybostampile4308 Před 20 dny

    hello, I can't find the answer in the manual: for connecting a SM Eastron SDM230, which colors from rs485 / inverter go to A and B / 5 and 6 from SM? possibly the grounding... thank you very much!

  • @nt4hx
    @nt4hx Před 5 měsíci

    System work mode > zero-export power: 20. What is this actually? I'm a little bit confuse but from my understanding it will use the grid (build in CT) power to sense the voltage, current and frequency to match with generated AC power by the inverter. However, my meter still detect I'm using about 1.2 A from grid all the time. I've battery connected everything should run by the battery but not sure why. There's people also reported this on the forum. I've set this zero-export power to 0 but still my enerygy meter is showing I'm using about 1.x A all the time to power the inverter (mine is 8kw and grid is 240VAC) so means I'm using about 300w from grid all the time. All my house power connected to smart load. In deye app it showing 1A but on graph it showing I'm importing 0.

    • @SolarKitEurope
      @SolarKitEurope  Před 4 měsíci +2

      As load amount changes quickly when a device is shut down, the inverter cannot reduce the power at the same rate. So, to avoid injecting electricity back to the grid when it is not allowed, there is a given consumption that is always drawn from the grid first before the inverter starts up. Depending on the amount and type of electrical appliances, this number could differ. If the meter shows that the system is injecting back to the grid when it should not, then this number needs to be increased. We suggest starting with 20 W, as it is usually sufficient for many households and won't significantly affect performance. This adjustment serves regulatory purposes only.

    • @nt4hx
      @nt4hx Před 4 měsíci +1

      @SolarKitEurope Let me rephrase again - here is the scenario: during the day, My PV is generating enough power to charge my battery bank and to supply house consumption (connected to inverter smartload output). the rest of excess power generated by PV are being sell to the grid. This is good. When turns evening, night or PV not generating enough power to supply, battery will supply power to smart load. Grid should remains idle as there's are not enough power to sell, however grid consumption is at 1A I'm importing 1A all the - not sure why? The inverter should be powered by the battery as well. I've set this configuration. If it's using maybe 0.2 A i don't mind but, 1A is about 300W (depending on pf) for standby.. x24 hrs x30 days that's about 200kwh which is quite substantial.

    • @odoohub5010
      @odoohub5010 Před 2 měsíci

      ​@@nt4hxyou can turn off grid charge, if that does not work, then do it manually by installing an isolator between your grid and inverter grid input, then switch the grid off.

  • @Chris-hw4mq
    @Chris-hw4mq Před 7 dny

    Why would I let you give me access to my equipment. I am the admin not you.