Why did the walk in cooler ice up

Sdílet
Vložit
  • čas přidán 16. 07. 2022
  • Got a call for a walk in box that iced up. Come along and let’s take a look, and find out why the coil iced up.
    if you would like to buy me a cup of coffee www.paypal.me/norcalrefrigera...
    music for videos www.epidemicsound.com/referra...
    #hvac #refrigeration #gopro
  • Jak na to + styl

Komentáře • 102

  • @stephenarthur5267
    @stephenarthur5267 Před rokem +4

    You are legit my new favorite guy to watch, saying out loud what all us techs think and say.

  • @YuShudNoe
    @YuShudNoe Před 2 lety +4

    Thank you Dave for explaining the solenoid diagnosis! I finally understand it now haha

  • @Taylor-bx8op
    @Taylor-bx8op Před 3 měsíci

    Coil turd oh that got me 🤣

  • @BLUE_COLLAR_REFER
    @BLUE_COLLAR_REFER Před 2 lety +1

    “Don’t ask me how I know, I’ll never tell you” haha 😄

  • @Eddy63
    @Eddy63 Před 2 lety +1

    You had me at liquor store 🤣😂😅 Good vid as usual... Thx for posting ...

  • @PedroGarcia-zl2ec
    @PedroGarcia-zl2ec Před 2 lety

    Good knowledge,excellent explanation 🙂

  • @harrydickson4575
    @harrydickson4575 Před 2 lety +1

    Great job Dave 👍👍👍

  • @pedrojardim1163
    @pedrojardim1163 Před 2 lety

    Thanks for great video very interesting

  • @TheGhettoLobster
    @TheGhettoLobster Před 2 lety

    Great call Dave

  • @mattn3273
    @mattn3273 Před 2 lety +1

    Big Dave to the rescue. Fantastic videos as usual. Keep up the great work and videos.

  • @DanO181919
    @DanO181919 Před 2 lety

    Great illustration on the solenoid valve…. Appreciate what you do!!

  • @ntsecrets
    @ntsecrets Před 2 lety +3

    Coil turd: I smell a new norcal Dave song coming! 😂

  • @DWAYNE2ism
    @DWAYNE2ism Před 2 lety

    hey, Dave nice job. And great video nice to see you having fun at work.

  • @belowzeros
    @belowzeros Před 2 lety

    fantastic as usual, things started off scary with that major pluggo situation

  • @davidharmon8745
    @davidharmon8745 Před 2 lety

    Stopped up.why did it frezze up.lol.Great job Dave.

  • @johnmarinakis7475
    @johnmarinakis7475 Před 6 měsíci

    Thankyou for the info you sure know your stuff Was very helpful ill run all the tests and clean everything out ill take it from there👍👍☺

  • @1960teko
    @1960teko Před 10 měsíci

    Side show Bob is going to be a favorite. Lol😊

  • @thesilentonevictor
    @thesilentonevictor Před 2 lety

    Two time clock on this unit madness and she need some serious love Dave is man for the job super tech 👌

  • @ianwilson1701
    @ianwilson1701 Před 10 měsíci

    Peace, appreciate your content, man

  • @johnbell6956
    @johnbell6956 Před 2 lety

    That’s some awesome water pressure. I always quote both minimal systems and what it should be. Customer can decide.

  • @garypoplin4599
    @garypoplin4599 Před 2 měsíci

    1:00 - I don’t know how far you are into the defrost; but, from the ice pattern I’m calling it a clogged condensate drain.

  • @billborglund2238
    @billborglund2238 Před rokem

    Fun thing to mention “ for the new guys” SV’s have to be sized correctly, not most by pipe size…learned that one the hard way.
    Great video

  • @jamierushing8811
    @jamierushing8811 Před 2 lety

    Hi bro from west Alabama love y’all

  • @WswRefrigeration
    @WswRefrigeration Před 2 lety +4

    Yupppp 404 ice machines need 404 lol
    Did a repair on an ice o matic. Boss has been using 449 for everything now. Told me to put in 449, ya it did not work right at all. Had to go back in with 404

    • @sjefoekel6058
      @sjefoekel6058 Před 2 lety +2

      But its envoirement friendly 😂😂😂

    • @analogmoz
      @analogmoz Před 2 lety

      I'm guessing 404 is needed to get the head pressure high enough for harvest?

    • @sjefoekel6058
      @sjefoekel6058 Před 2 lety

      @@analogmoz no its just shyte refrigerant

  • @kingofthecrease30
    @kingofthecrease30 Před 2 lety +1

    RSG (master bilt & norlake) and kolpack have those dual speed ECM fan motors...box reaches temp and the evap fans run half speed until it turns the compressor back on....they use a 3 wire johnson controls thermostat.

  • @marknaravas318
    @marknaravas318 Před 2 lety +1

    Coil turd😂. You have WAY too much fun at this job!

  • @garyglenn1445
    @garyglenn1445 Před 2 lety

    Turd Among US that things hammered!!! But good as new after the Nor Cal Dave special!!!!

  • @scottk0623
    @scottk0623 Před 2 lety +1

    🤣🤣I can’t remember if I ever saw a fan guard with that much junk on it. Love their maintenance program, service on repair🤦🏻

  • @williamgeyer4389
    @williamgeyer4389 Před 2 lety +5

    Hey Dave! Do you ever analyze the coil scat for diagnosis? You know, like a good animal tracker. Smells, taste, looks. I bet that can make the overall diagnosis easier 🤔

  • @michaelrodrigues246
    @michaelrodrigues246 Před 2 lety

    I just ran into the same exact call the other day a three-year-old sporlan solo noid valve

  • @saltrue1555
    @saltrue1555 Před rokem

    Good video thank you God bless

  • @redneckways1617
    @redneckways1617 Před 4 měsíci

    You could have just taken a temp reading on both sides of the solenoid valve when closed to see if it was leaking by

  • @jibaritomx
    @jibaritomx Před 2 lety

    To remove that kind of dirt from evap coil I have been using supco ccb100 life saver xD

  • @MariosACandRefrigeration
    @MariosACandRefrigeration Před 2 lety +1

    you could have used the pins to have 4 defrost,what i would be afraid if it freeze the beers.

  • @brnmcc01
    @brnmcc01 Před rokem

    Haha, we got a 1 strapper! I'm guilty, I've done the 2 ziptie! (But wrapped with some foam tape, and a couple more zipties).... 😆😆

  • @quetzelcotle3816
    @quetzelcotle3816 Před 2 měsíci

    The suction is higher than my check 😂😂😂

  • @mainj54
    @mainj54 Před 2 lety

    That time clock was set for a 2 hour defost at 2 am. Should be enough to keep the coil clear for a few days.

  • @ore-georgecicovic6533
    @ore-georgecicovic6533 Před 2 lety

    Thanks for great video. Did you pull vacuum after opening that solenoid and did you do it at the evaporator or upstairs at the condensing unit? Thanks, cheers

  • @apprenticephil649
    @apprenticephil649 Před 2 lety

    Super tech twisted his spine changing that TX, but ignored the obvious dirty evap. Been there.

  • @philliphall5198
    @philliphall5198 Před 9 měsíci

    I AllWAYS thought a freeze up is because of moisture or heater not working properly ???
    I’m leaning to ask a lot of questions 😊 Thank you 🙏

  • @heavydiesel
    @heavydiesel Před 2 lety

    That coil turd was a toe stubber!
    I've done that with the flare nut 🙈🤣 Had to cut it in half with the grinder as was on outlet and suspected frost would crush the pipe and cause issues.
    Those condenser fans stopped a bit quick, tight bearings?

  • @RobertL78
    @RobertL78 Před 2 lety +1

    You gotta love the people who bury the thermostat thinking it will engage the mythical “turbo mode” cooling.

  • @eugenegrzeca4214
    @eugenegrzeca4214 Před měsícem

    Just wondering why you did not shut up the low pressure control to act as the thermostat for the weekend it's old school but sometimes you gotta do what you gotta do

  • @REFRITEKREFRIGERACION
    @REFRITEKREFRIGERACION Před 2 lety

    One of my friends charged an ice machine with r449 and he got lucky. I told him don't do it because I remember you mentioned it on another video.He got away with murder. Im sticking with r404a for ice machine too.

    • @NorCal-refrigeration
      @NorCal-refrigeration  Před 2 lety +2

      The 448 worked but it was flooding back and there’s no adjustment on those txv’s. Also the charger is so small in ice machines the 404a is the way to go.

    • @brnmcc01
      @brnmcc01 Před rokem

      @@NorCal-refrigeration I have a few Koolaire I bought couple years ago for some of the restaurants, they have 410a in them.

    • @NorCal-refrigeration
      @NorCal-refrigeration  Před rokem +1

      @@brnmcc01 the only issue I’ve had with those are noise complaints. Window shaker compressor are noisy.

    • @brnmcc01
      @brnmcc01 Před rokem

      @@NorCal-refrigeration The ones I got are from around 2-3 years ago, they had small scroll compressors in them, I think LG, not sure. They are pretty quiet though. One of them I got the remote condensor for, and put that on the roof. That location they have really hard water, and I didn't want to use a water cooled unit. Was pretty easy to run a 20ft precharged lineset up to the roof.

  • @sherwinalvarez7365
    @sherwinalvarez7365 Před 2 lety

    Hey Dave. Dont know if i missed it, but do you need to pull a lil vacuum after taking that solenoid apart.

  • @pimwear2niee421
    @pimwear2niee421 Před 2 lety

    7:01 am in Texas

  • @ThizzSnake
    @ThizzSnake Před 2 lety +1

    can you elaborate a little bit on the tell a system is overcharged by your head pressure during a pump down thing? good charge it falls a little, it rises its overcharged?

    • @NorCal-refrigeration
      @NorCal-refrigeration  Před 2 lety +2

      Over charge head psi will sky rocket 🚀 on pump down.
      Now it will rise a little at first then start to fall as system pumps down if charge is ok.

    • @ThizzSnake
      @ThizzSnake Před 2 lety

      @@NorCal-refrigeration thanks! Appreciate the reply and knowledge

  • @jhhawaii8
    @jhhawaii8 Před 2 lety

    Hey Dave, I was wondering about whether or not if you ever tried an ultrasonic leak detector. I heard it might be able to have you help diagnose leaking valves during operation. I picked one up recently. Seems promising. Just got to try it in the field.

  • @michaelmonfeli736
    @michaelmonfeli736 Před 5 měsíci

    Who doesn’t go outside with the unit. Cold or not, unit belongs outside when dealing with walk in boxes

  • @Jon.Rushing
    @Jon.Rushing Před 2 lety

    Hey Dave are you still using the coil cleaner from Home Depot and what was the brand of it?

  • @davejohnsonnola1536
    @davejohnsonnola1536 Před 2 lety +1

    Always bemused at seeing how many wood paneled walk ins you call on. Is this common anywhere else?

  • @fredflintstone8048
    @fredflintstone8048 Před 2 lety

    Thanks for the coil and fan cleaning porn. That poor system was really constipated. I'm sure it loves Dr. Refer coming along and helping it get rid of those coil turds.

  • @thepoopsoup
    @thepoopsoup Před 2 lety

    I wash out the grills on a milk case to not bend over so much. Yayyyyyy

  • @scottbig123
    @scottbig123 Před 2 lety

    Do you go to RSD Salinas or SJ?

  • @mikev.1034
    @mikev.1034 Před 2 lety

    👍🤘🤙

  • @kingofthecrease30
    @kingofthecrease30 Před 2 lety

    is that an old peerless evap coil ? would expect that in a wooden walk in box. Outdoor units are protected from any weather especially rain...also prevents pigeons & other birds from building homes inside the units

  • @bobbytsiamis8553
    @bobbytsiamis8553 Před 2 lety

    After taking apart the solenoid did you pull a vacuum from the low side?

    • @NorCal-refrigeration
      @NorCal-refrigeration  Před 2 lety +2

      Correct that’s all you need to do. With a call for cool so the solenoid is open.

  • @shine-cg9uf
    @shine-cg9uf Před 2 lety

    🇺🇸❄️💪👍 great vid n troubleshooting. A call like that n with defrost n cleaning, is that a good 3 hr call ?

  • @timothydelgado4907
    @timothydelgado4907 Před 2 lety

    If you did a pump down and the system is over charged what would your high side pressure look like?

    • @pizzapale
      @pizzapale Před 2 lety +1

      Your head pressure will go up instead of falling, basically the receiver is over full and theres no where else for the refrigerant to go so it builds up pressure.

  • @bernadettelee7670
    @bernadettelee7670 Před 7 měsíci

    Would you recommend for business owners to have walk in cooler checked for maintenance? Once or twice a year?

  • @briancarlisi2224
    @briancarlisi2224 Před 2 lety

    Do you charge a fuel surcharge during this high price time?

  • @danbell1733
    @danbell1733 Před 2 lety

    Bad case of crustytitus there Dave!!!!!

  • @crg061
    @crg061 Před 2 lety

    Hack and Moe put did that install, I know it !

  • @rocker8692
    @rocker8692 Před 2 lety

    You should sell them on a maintenance maybe.

  • @ChingusTheOneAndOnly
    @ChingusTheOneAndOnly Před 2 lety

    Hey now

  • @robertpeters9438
    @robertpeters9438 Před rokem

    You need a baby swimming pool for situations like this one.

  • @IFIXCASTLES
    @IFIXCASTLES Před 2 lety

    How they pass health department????

  • @sjefoekel6058
    @sjefoekel6058 Před 2 lety

    Change over to on off instead of pump down, the spring pressure does not close the flow, its refrigerant PD what does it.

  • @nategadow4482
    @nategadow4482 Před rokem

    Coil turdasoris🤣🤣🤣

  • @nikyjim
    @nikyjim Před 2 lety

    that whole box is fucked!

  • @timporter7760
    @timporter7760 Před 2 lety

    ᑭᖇOᗰOᔕᗰ

  • @mikelilley
    @mikelilley Před 2 lety

    Love this guy, has mad skills..... Intro music is just awful. I have to turn off my speakers.

  • @steveblake8766
    @steveblake8766 Před 2 lety

    166 Thumbs uP