Ductile Detailing of Column as per IS-13920-2016 | Column detailing IS-13920 | Column Reinforcement

Sdílet
Vložit
  • čas přidán 12. 09. 2024
  • Hello Friends,
    This video explains what is ductile detailing, why ductile detailing is provided, and factors that need to be considered as per IS-13920-2016.
    Keep Watching!!! Happy Learning!!!
    Join this channel to get access to perks:
    / @civilengineeringmastery

Komentáře • 6

  • @civilfundaments
    @civilfundaments Před 5 měsíci +1

    confinement zone is a) Larger of lateral dimension of column b) 1/6 of clear column height c) 450mm which ever is larger

  • @sidseergaming
    @sidseergaming Před 25 dny

    I didn't understand figure 9 case... Is it used when column is shaped like that? But what will be the purpose of such shaped column?

  • @logeshwaranpalusamy821

    Hi ...The cross section aspect ratio shall not be less than 0.4 as per amendment no.1 and Hook dimension 8d or 75mm in same amendment. FYI

  • @PankajSingh-me4th
    @PankajSingh-me4th Před rokem +1

    Good