In this video, I will explain,
1. Reinforcement lapping Zone as per IS Code 13920 in Column
2. What is the reason behind this?
3. What is Reinforcement Lapping?
4. What is the function of Reinforcement lapping?
5. Bending Moment Diagram of Column
⓿My Playlist Link
✔HOW TO STUDY DRAWING
• How To Study Drawing
✔CIVIL INTERVIEW
• Interview
✔CHECKLIST OF CIVIL WORKS
• Checklist of Civil Works
✔BBS (BAR BENDING SCHEDULE)
• BBS (Bar Bending Sched...
✔QUANTITY ESTIMATE
• Quantity Estimate
✔CONCRETE VOLUME CALCULATION
• Concrete Volume
✔IS CODE LECTURE
• IS CODE LECTURE
✔DREAM HOUSE CONSTRUCTION SERIES
• DREAM HOUSE CONSTRUCTI...
✔HOUSE CONSTRUCTION
• House Construction
✔HOUSE PLAN
• House Plan
✔CIVIL EXPERIMENTS
• Experiment
✔SURVEYING
• Surveying
✔CIVIL ENGINEERING TALK
• Civil Engineering Talk
****************************************************************
Official Website in English: www.learningtechnologyofficia...
Official Website in Hindi: www.civilofficial.com
****************************************************************
#CivilEngineerMukeshSah #ReinforcementLappinginColumn #LapinRCCColumn #LappingZoneinColumn ReinforcementLappingZone #CivilEngineeringVideos #LearningTechnology #L&T-LearningTechnology
Video ko Daba ke Share karo bhailog aur apna pyar dikhau.. Taki hamare sabhi bhahiyo, hamare Juniors aur Engineers tak pahuch sake.
Sir plinth beam top se floor beam bottom hight hi length hoga kya
I like ur videos more than other's videos.....
Sir middle zone me to bending moment kam hota he na tabbi ties ki spacing ku kam rkhte he
It's good explanation and very easily understood.
Good and informative video. Thanks!
Sir aapka video dekhne ke bad pura tarah se satisfied ho jata hu bhagwan aap ko aise aur mind ko clear rakhe 👏
Sir I'm form Bangladesh,You are my very good teacher.Your explanation is very good sir.
Thank you so much,keep your update your video.
Sir I am Engineer but I can't explain as you explain. Thanks sir 🙏
अच्छा.व्हिडीओ.धन्यवाद.सर.
Also make video on staircase. As most of the people get confused while calculating treads and risers on actual site. Most important is staircase which is starting from some random floor. Which is not in continuation.
I have downloaded your IS Code app.You have done a fab job brother.
your explaination is very good
Mukesh ji I like you for good teachings
u r so good person! ❣️
Allah bls you
Thanks For Teaching Sir
#Beam zone required. Beautifully explained.
Excellent sir.. 👍👍👍🙏🙏🙏🙏
Bro ur teaching is damn good
👍🏻 Keep it up
Tnx for clearing my concept
Excellent sir
Good job 👌
Thank you for your support
Bahat achhaa!
Hats of to you sir...
NYC videos about lap zone
Superb video sir.
#Beam and Slab lap zone
knowledgeable video sir 👌👍
Thank You Sir
Also make video on beam and slab for overlapping
Well explained
Thank a lot sir
Very nice👌👌👌
👍👍# good lap zone in column #
Beam lap also required .
Thank you soo much.
Thank you very much for the practical knowledge on Lapping Zone in column.
It is increasing our knowledge and confident in real time environment in site.
I have one question regarding column.
What could be the solution if the length of the reinforcement from isolate foundation is not enough for Lapping which should be provided for second or next story of building ?
Thank you and Regards!
Shailesh Singh.
Nepal
nice information , take a example of floor to floor ht 4 m , and give detail of lapping and lap length for footing to coloum , and above
Thank u sir
Very well and technically explained
Very good video
Share and Keep Learning
Your my Guruji
Good sagsion
Very Good Follower Base. Good Luck. #Success555
Its very good vidio. Please make vidio on mivan Constructions steel.
Thank you sir.....ur valuable information.sir i want to know that about bbs.
Very nice sir .make vedio also beam ,slab lapping
Absolutely sir
Thanks for Ur valuable information. I want to know one information, what is the joggle length and its ratio of the lapping bar as per the code reference.
Will make video on it
Auto level pe video banao sir....
Bhut gazab sir Plz Do some Thing for compitative exam
PLEASE MAKE A VIDEO ON LEVEL OF. SLAB. ( SLAB ka level kaise check krte hai before casting)
Excellent sir. Please sir still ki quantity nikalna batao. Kaise still ki quantity ko nikale total slab, beam, coloum etc.
from the edge of the bottom or the top of the slab into the column, what shall be the minimum distance to provide the ties.
Very nice app
Sir I have one doubt about feture extension of building we leave 1 height of steel for feture extension but that is not a lap zone.then what we do for that for over come that problem
Nice sir
Thank u dimpal ji
Lap joint in beam as per is13920 2016
Sir , now column height is 2.5m and stirrups spacing is 150mm. This data’s are given as per drawing ..L/6 area it has less spacing .I what spacing should use here (L/6)
Sir plz bta dain stagger kB provide krte hai raft me
Plz make a video on importance of primavera p6
Sir while calculating L beam depth should minus or not
Hello sir..
Yaha lap ham upar se jo joint karenge us steel me dena hai ya niche wala me.
Please make videos on RE wall highway
Column ki laping beam wale porsen me kr sakte h
Sir ; Bridge pier or abutment will be same Lapping zone
In addition to that minimum clear vertical distance between lapped bars shall be 0.25 times lap length. What is this?
#beam pl. Sir bnao, and also explain how to decide L lenght of primary & secondary beam at end of beam.
Slab beam ke Ander column r/f ka lap de sakte h kya
Sir colomn ki clear length beam bottom se Lena hai ya slab bottom se ? Kyoki beam bottom , slab bottom se down hi hoga
# plz tell about cutting length of steel from foundation so that we can avoid zone A for floor height 3mtr..❤
Hi mukesh... i have a question. Between both the lapping zone how much should be the spacing? I mean 50% rebars to be lapped below centerline and 50%above centerline. Should there be any gap between these staggered bars?
Mukesh ji only column beam junction mai actually minimum numbers of ring set kitne provide krne chahiye as per which is code
Sir me assam se hu . mera building me column ka 6 sariya me 4 ko job join kiya tha usme laping kiya baki bij ka 2 me laping kiya nahi .kiya kharab hoga kiya .abhi me groun floor banaya he .
Pls explain abt shear wall bro
What happen if the lapping given by welded ? Kindly make a vedio about why engengeers do not let welding any rebar joint in the building design ? Please let me know ! ?
waterpoofing mixing details at buildings prepare one video sir.....
Lapping lower dia ya higher dia interview Questions?
Also make a video on water proofing of terrace. What are the best materials present for it in the market.
already made a video on waterproofing of terrace..few days back... check my videos
@@LearningCivilTechnology yeah sure...Great 🙂
Thank you for this video.pls make a video on beam lap required.👍
Sir splice mai jo ties provide krte hai uska spacing kitna hota hai ???
Kindly make a video on accelerator and retarders, plasticizers and superplasticizers
What type of joggle,joggle methologi, IS code standard interview Question?
Agar zone B me bars ko starting karni padi to kya karenge. How it possible with overlap?
Jab ham clear cover ki baat karte hain to beam ya column dono cases me yah clarify Karen ki langitudinal bar ke outer face se clear cover consider Karen ya stirrups/ ties ke outer face se.Thanks
Total station operation video banaye sir G
🙏 🇮🇳 👍 😍 #beamlap required
Sir, I want to know that.... Ki sariya ka dia Or quantity saman hona chahiye ya nanhi..... 1000sq building ka sab Callum ka
Sir clear span for lap in column is from beam bottom or slab bottom please tell me from where we take l/4 length please explain sir
From soffit of beam
Mukesh tum yaha ho..Mai Kabse dhund rha tha
G+2 ke liye column, beam or plinth Ka kya size rkhe
Bro,in lap zone do we used 45D
2Good
16mm bar 45d kar k kat diya hun... isku over lapping dene se koi problem hoga????
Please make a video on Beam and shear wall according to IS 13920:2016. IS-13920:2016 is very jumbled and difficult to understand.
Sir it’s not available in App Store .. I could not find .. pls help
# beam lap explain please sir
Beam lap required Sir ji
#beam zone required
#parapet part, column extend wat height we should leave for further construction and lapping on it, tag mee bro when u upload
Bar me Kita mm ka minimum rod use karte hai
Kese Membership lena hai
sir , colomn ka lapping to pura samajh gaya but beam or other member ke liye bhi vedio bana dijiye sir , please
# beam lapzone video
Yadi lap plinth beam me hai to Sahi hai ya galat ,yadi galat hai tab kya kare
how can we get your apps on ios.?
# Bram lapping required