Plinth Beam Size size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey
Vložit
- čas přidán 5. 08. 2021
- Plinth Beam Size size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey
Disclaimer - This video is for educational purposes only. Copyright Disclaimer under section 107 of the copyright act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship and research. Fair use is a use permitted by copyright statutes that might otherwise be infringing. Non-profit educational or personal use tips the balance in favour of fair use.
beam size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house
In this video we know about column size and sariya details for Single storey building, double Storey building, 3 storey building, 4 Storey building & 5 storey floor building and also know about what is minimum and maximum distance between two-column. Ek manjila Makan, do manjila Makan, 3 मंजिला मकान और 4 मंजिला मकान के लिए कॉलम का साइज और सरिया क्या होना चाहिए. column size for G+0, G+1,G+2,G+3 Building construction.
#PlinthbeamStandardSize #PlinthbeamReinforcement
Topic Covered:-
beam sizes for various floors
plinth beam size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house,
building design
various plinth beam sizes
what is the beam size for the g+1 building
minimum beam design
g+1 building design
beam design
minimum size of column
column size for ground story building
different column sizes
apartment building column sizes
building design by staad pro
plinth size for 1 storey building
plinth size for 2 storey building
plinth beam size for 3 storey building
beam size for 4 storey building
beam size for g+0 building construction
beam size for g+1 building
beam size for g+2 building
plinth beam size for g+3 building
RCC Column Standard Size
RCC beam standard size
the standard size of the beam
standard beam size residential building
plinth beam size calculation
Bar Bending Schedule Basics: Especially for Freshers Civil Engineers (Bar Bending Schedule Part-1) Kindle Edition
amzn.to/3uvEMNo
My Social Media Link:-
Telegram Link:-
t.me/yoursengineer
Facebook page:-
/ yoursengineer
Facebook group:- / yoursengineer
Twitter link:- / yoursengineer
Instagram link:- / yoursengineer
Pinterest:- / _created
Linkedin:- / vishal-goel-17426a48
Website:- myengineeringsupport.com
Accessories I Use for making Videos
Mic I use - amzn.to/3r5f1S6
The laptop I use - amzn.to/3ayYNu3
Laptop Stand I Use- amzn.to/3cnILpj
_______________________________________________________
LIKE | SHARE | SUBSCRIBE FOR MORE VIDEOS LIKE THIS
~
THANKS FOR WATCHING! -ENJOY
===============================
Bahut hi short video me aapne achchi jankari de di.thank u sir
Welcome
Awesome explanation sir....thanking you a lot...
Bahot achchha jankari di sir aap ney Sukriya sir
Thanks alot
Baat karni hai ji
Superb sir thnx u for great knowledge 👍
My pleasure✨
Great information 👍😊
thank you very much sir
Good information
Thankyou
Please talk about roof beam size for 3 storey house
Noted
If all group builds lead saliya, sikud or box type, your mapping will keep cowered front while basements will operate 174_ west room ceilings on u yahoa type instead stitch plinth, makes none foundation. It is a misrepresentation to put refined bars in plinth ie to keep ply before five root storeys.
thanks for sharring...👍👍👍new subscriber..
Your welcome🎉🎉🎉🎉
Sir agar plinth beam me 12mm ke 6 saliye dede our 5 floor banan ho to koi dikat to nhi hogi na
hi. very good informative videos for non professionals of civil engineering, do you have any details or standards of lintel beam for G2 storey building
Video available on channel
Kya plinth beam se column start kar sakhte hai aghar pehle se column nahi banaya ?
I think yes
Sir fast manjil ke liye plinth beam ka saige kya hona chaiye
Minimum 12 mm ke 4 bar
Normally plinth beam is provided at ground level or at below ground level. The size of beam depends span of beam and the load it carrys say 9" wall or 4.5" wall and type of soil. As perIS bending moment on plinth beam is wl^2/30 without support. You have shown more than one beam in a G+3F and size is constant only reinforcement only vary without mentioning span of plinth beam. What about span. Minimum stirrups is 8mm dia and not 6mm dia.
V.M.RAJAN.
Ohk thank for information
Column size 8x12 inch. Average distance between columns 11 ft. Wall thickness 8 inch. Plinth beam size 8x10 inch. I want to constract g+2 building. Will it works?
Sir G+1 storey mai kevel 5 rebars honge ya top extra and bottom extra rebars bhi provide karna hai?
👌
👍
Suppr sir
Thanks
1se5 manjila ghar ka slab bem latak bem me kya steel Dena hai
Can we use 6mm for stirrups in beam 10"*10"
Yes
sir, explain plinth beam sizes for g+4.
Good
Thanks
Hi Brother Make video and tell us about column size and the plinth beam size as well up to 4 story house please your videos is very helpful. Thanks
All video available in house construction tips playlist
Okay thanks
Sir G+1 storey ke liye 4 bars 12 mm ka hone se hoga kiii nahi please reply me sir bohut tension .mein hein sir and also tell me the cutting length of stirrup
G+4 ke liye plinth beam aur latak beam ka size 9/12 le skte h aur ush m 12 mm ke 4 sariya continue aur 12 m ke 2 top extra aur 2 bottom extra le skte h ya fir 6 ke 6 continues hi use kare konsa best option rhega ya kuch aur
6
Sir 1.5feet ki plinth beme me 6 sariya lagana hai to kya 3-3sariya side side me rahega ya uper me 3 aur niche me 3 de sakte hai kya
No
Sir hum footing mein 10 mm rod deya hai or column mein 6 12 mm rod deya hai or column size 10×12 beam mein 4 12mm 2 10mm rod deya hai and beam size 10×,12 kya mein g+2 bana payenge pls reply me sir please
What about crank rods ?
9*15 column 4rod12mm aur 2 rod10mm kitne floar le sakte please reply
10mm wrong
Ground floor pe 10 mm ka sariya lga h to 2nd floor construction time me cloum & Plinth me sriya ka size 12 mm ka diya ja skta hai ya nhi present & future time ko mind me rkhte hua hi frankly answer dijiyegaa
I wait for my answer
🙏🙏 have a nice night🙏🙏
No
Dear sir,
How to calculate the average spacing of ties, if a column having length of 3 m. The spacing of ties in CR (i.e. 1 m) is 125 mm and in NR (i.e. 2 m) is 175 mm.
Thanks
150mm
Sir Gi g+4 ke liye kya dena Hoga RAINSFORMANT sariya our uper floor Ka beam me kum krte Jaye floor to floor Jaise uper bdta Jaye
Yes km kr sakte ho
@@myengineeringsupport sir ji es topic pe ek video bnaye g+4 house me kaise beam Ka sariya kum krte Jaye uper floor bnate hue logo KO help Hoga essa video NHI h 🙏
Sir 4 storey tk pura beam sariya ka details btaye.....
The column of the four-storey building gave a video on reinforcement.
Ok
May I use 4 nos 16 mm rod for 10"×10" column for two storey house?
Yes
@@myengineeringsupport thank you.
Hi sir,
Area 1000 square foot
Foundation 10 foot deep 15 nos
10 mm k 6 bar
Three storey house
Is it good ???
No.. 10 mm bar rod app pillar me lagao ge ... 😢 Too week
Sir slab beam and lintel beam ka size kya rakhe
Depends on storey
G+2 ke liye
Sir kya hum beam ka size 9/12 le skte h G+3 ke liye aur sariya 6 dia 12mm ke use krte h kya
Yes
Sir plinth main 16 mm rod lagaye to Kya hoga
Money waste
What about short column house construction for two storey house.. Please reply..
Yes you can construct with short column
Sir, column till plinth level then only brick wall without any column... Can i build two storeys like this way.
RCC, Structural designer not provided this method.
Ok
Sir plz talk about G +5
Ok
Stilt+5 Storeys Design?
Hello sir
G-3, For column -(16mm-4),(10mm-2), Total -6, .i want suggestion,please reply me sir, 9" /12"
12*12 beam size 6 12mm rods every beam have a distance of 12feet in any side and plinth beam also same.....Is it good for g+2 storey building pls reply...
Afcourse you can
@@myengineeringsupport sir the same g+2 building can I use 16mm rods 4 and 12mm rods 2 for stronger quality beam same 12*12 inch.....pls reply sir
Sir SHYAM STEEL THIK HOGA...
Yes
Sir ji B+G+4 ka Makan banana hai uske liye hamen khudai kitni gehri rakhni hai pillar Kitna jameen ke andar jaega please reply
Minimum 7feet
For G+2 building I am using 8"x10" plinth beam and using 4 16mm rods. Will it work?
No
@@myengineeringsupport will it work for g+1?
Not recommended 8"
@@myengineeringsupport since wall is 8 inch plinth beam size is 8x10 inch
Ohk
How much you charge for making drawing for house sir???
4Rs/- sqft
Sir, mera plinth beam ka size 10*12 inch ka ha aur tmt bars 2, 12 mm top me and 2, 12 mm bottom me and 1, 16 mm bottom me middle position me diya ha total 5 bars. Mera question ha kya me iss beam me 3 storry building bana paunga? Plz reply 🙏🙏🙏
Not enough
5*16mm cost = 7500/-
(4*16)+(2*12)mm cost = 7700/-
So over all 4storey ki plinth beam cost 3storey ki barabar
May be
What about g +g
Sir ye jo 9*12 ka naap hai ye with slab hai ???
Yes
@@myengineeringsupport thnk u sir
Sir mera room size hai ek 12 *15 na usme column distance hai one side 10 one side 15 column hain 9*15 k steel hai 4 baar16 k and 4 baar 12 k and beam size with slab 9.*14 kya ye thik hai ??
Beam main 4 baar16 ke and 1 baar 12 ka hai
Aut main kitne floor tk ja skta hu
साबसाबज9"का 23 सेन्टीमीटर बता रहे है मै क्या करू?
Yes 9 inch ka itna hi hota hai 23 cm ya 230mm
what about g+5
Notef
Sir ring ka size kya rahega
8 to 10mm dia
Dhalai 15 inch karna hai ki 12 inchh
Beam size should be not less than 9×12 whether it's a G,G+1 ,etc....
Column size should be not less than 9x 9
Length of beam
16 feet safe
Lekin l nai moda hai
Moda h
Hello sir.
Area: 540sq. Feet
Column : 10'*10', 4bar of 12 mm and Total no. of column is 12
Plinth foundation : 12 feet deep
We want to make it G+2 is it possible sir?
At second floor it will be a hall and no extra dead load.
Distance between 2 column is 10 feet and some are under 5 feet.
Plz. Help sir.
Yes it is ok but no need to given too much column
Rong
اتنی لمبی اور بے سود باتیں شامل کردیں
title me 5 storey kyon likha jab 4 tak hi batana tha
Good information
Thanks🙏