    4 types of dg checklist that every engineer should know
    What is preventive maintenance
    Preventive maintenance is the process of scheduled checking, replacement of parts, and servicing of a machine to maintain the performance of the machine, increase the efficiency and continue the reliability of the machine.
    Why it is important
    It is cost-saving
    Increase the efficiency of the machine
    Reduce the breakdown time of the machine
    To Continue the safety of the machine
    Diesel generator preventive maintenance dg checklist
    There are mainly four types of dg checklist that perform on during preventive maintenance
    A check
    B check
    C check
    D check
    A check
    A check performs daily checking procedure of diesel generator sets.
    Check oil level in the diesel generator sets.
    Check cleanliness of diesel generator sets.
    Check battery voltage
    Check for any type of leakage
    Check all filter condition
    Check coolant level
    Check the condition v-belts
    B-check-B-check performs on weekly basis or after running hours of (300-350) hours.in this type of check following parameters should be checked:
    Change oil
    Change oil filter, fuel filter, and bypass filter
    Change air filter
    Change water separator
    Radiator cleaning with chemical
    C-check-c-check performed on monthly basis or after running hours of (800-1500) hours
    Check all electrical conditions
    Check pollution level
    Change oil
    Change oil filter, fuel filter, and bypass filter
    Change air filter
    Change water separator
    Radiator cleaning with chemical
    D-check-D-check performed on yearly basis or after running hours of (3000-5000) hours.
    The complete dg set should be dismantled.
    turbocharger service
    injector pin service
    cylinder head service
    PT pump service
    Change oil
    Change oil filter, fuel filter, and bypass filter
    Change air filter
    Change water separator
    Radiator cleaning with chemical
    video created by unnipgs electrotech
    DG Cummins 380kva
    Powerica Stamford sunitha sales and service
    topic covered
    1. DG maintenance procedure
    2. A check
    3 B check
    4. C check
    5. D Check
    6 coolant checking
    7 oil level checking
    8 diesel level checking
    9 v belt checking
    10 battery voltage checking