Piping Engg : Cathodic Protection Calculation - Sacrificial Anode

Sdílet
Vložit
  • čas přidán 5. 08. 2024
  • G. S. Samanta : Engineering & Educational

Komentáře • 33

  • @mukarramalvi9204
    @mukarramalvi9204 Před 3 měsíci +1

    Excellent explanation

  • @subhasgram
    @subhasgram Před 5 dny

    Very nice explanation but very much complicated equations

  • @maxero4p
    @maxero4p Před 5 měsíci

    Very nice video

  • @user-ot3tw3xf2x
    @user-ot3tw3xf2x Před 5 měsíci

    Very good ❤

  • @skma1911
    @skma1911 Před 5 měsíci

    Very nice

  • @user-ze6rx4ie8v
    @user-ze6rx4ie8v Před 5 měsíci

    Very very nice 👍

  • @user-lf3ds7ph2l
    @user-lf3ds7ph2l Před 5 měsíci

    Very nice 👍

  • @gurjeetsaini2711
    @gurjeetsaini2711 Před 5 měsíci +3

    Sir please post for ICCP system also.

  • @user-pl1mp4nx7j
    @user-pl1mp4nx7j Před 5 měsíci

    Very good 👍

  • @Kritix5o
    @Kritix5o Před 5 měsíci

    Darun

  • @user-po6de4tu5l
    @user-po6de4tu5l Před 2 měsíci

    Thanks ❤

  • @maxero4p
    @maxero4p Před 5 měsíci

    Very very nice

  • @learnmillwright
    @learnmillwright Před 3 měsíci

  • @Kartik1g933
    @Kartik1g933 Před 5 měsíci

    Very nice sir 👍

  • @rajmariappan
    @rajmariappan Před 5 měsíci

    I made same calculation but i am getting incorrect answer. 3) 1.197 mA and Rh in calculation 4) 1.192Ohm why?

  • @pravinnkumar7835
    @pravinnkumar7835 Před 5 měsíci

    Hello Sir, Does a Hot water vessels located above ground, For instance, at a 20m height needs sacrificial anode?

    • @gourisankarsamanta7670
      @gourisankarsamanta7670  Před 5 měsíci

      Water vessel can be installed over a supporting steel structure. Above ground structure or pipeline or vessel does not need any cathodic protection, needs only painting.

  • @diyaazaghloul756
    @diyaazaghloul756 Před 5 měsíci

    Please Shared numerical solved example of impressed current cathodic protection

  • @elio9207
    @elio9207 Před 3 měsíci

    Can i have sacrifcial zinc anode to my Trampoline mat just screw it in the frame? And preventing rust?

    • @gourisankarsamanta7670
      @gourisankarsamanta7670  Před 3 měsíci +1

      Yes, it will work.

    • @elio9207
      @elio9207 Před 3 měsíci

      @@gourisankarsamanta7670 it hasnt to be in to water as they using for boats or using any electricity.
      It just will work and prevent my Trampoline to rust??

  • @rajmariappan
    @rajmariappan Před 5 měsíci

    Step 4 some mistake in unit conversion. Can you please check. I used 0.0521 instead of 0.00159 then only getting answer. why did we calculate Resistance of ground bed?

    • @yahshuatabilog7163
      @yahshuatabilog7163 Před 2 měsíci

      the reason why you need to calculate the resistances of ground bed is to check what is the best anode to use, anode is base of what resistances of soil so if that is high resistances low resistant may changes the factor of what kind of anode you should be use, in onshore nearby sea we use zinc anode because it has a low resistances and we use magnesium anode in desert area because of its high resistance compatibility beacasuse magnesium anode has a high voltages , exceeding 2 000 ohm-cm. that is why magnesium anode is widely us in remote area

  • @rajmariappan
    @rajmariappan Před 5 měsíci

    In step 3 we should not divide Jc/1000 insted we need to use Jc as it is since it is unit is ma/m^2 then we will get answer 1.197A

  • @rajmariappan
    @rajmariappan Před 5 měsíci

    Nice video but Itot=1.197 mA not A

  • @danielodeliro2412
    @danielodeliro2412 Před 5 měsíci

    Thank u sir
    But first question is which underground line need cathodic protection?

    • @gourisankarsamanta7670
      @gourisankarsamanta7670  Před 5 měsíci

      It may be any underground line, like water, air, etc. To protect the Pipeline from corrosion, we need to provide cathodic protection system.

    • @danielodeliro2412
      @danielodeliro2412 Před 5 měsíci

      @gourisankarsamanta7670 is there any standard or other reference for this question?

    • @rajmariappan
      @rajmariappan Před 4 měsíci

      @danielodeliro2412 . All underground Pipelines subject to corrosion due to the oxidations are required cathodic protection. For example. all carbon steel pipes are required Cathodic protection. There is no specific standard for this but this will be recommended by the corrosion engineer.

  • @karthiasundaram
    @karthiasundaram Před 5 měsíci

    Very nice video

  • @user-wc2er9id6g
    @user-wc2er9id6g Před 5 měsíci

    Very good 👍

  • @user-eh6yr8mq9n
    @user-eh6yr8mq9n Před 5 měsíci

    Very nice sir 👍

  • @Sonjib8zd5lr3n
    @Sonjib8zd5lr3n Před 5 měsíci

    Very nice