  • This is a short follow-up video to DR #47. In this video, I finish servicing and testing the NAD 2200 power amplifier. This includes a nearly complete re-cap, a relay replacement (with slight modifications), idle current and DC off-set adjustment, and testing.
    This was a very satisfying service.
  • Věda a technologie

Komentáře • 20

  • @peter.stimpel
    @peter.stimpel Před rokem +2

    Nick got his voice back, and I love it. How do they judge the price for those electrolytics, what is so special about them?

  • @wayneg296
    @wayneg296 Před 4 dny +1

    👍👍😎✌️🤟

  • @TravelOutlook
    @TravelOutlook Před rokem +1

    Nice one Nick. Satisfying indeed!

  • @KuntalGhosh
    @KuntalGhosh Před rokem +1

    That analogue scope looks mint 👍

    • @dualityrepair4770
      @dualityrepair4770  Před 11 měsíci +1

      Agreed @KuntalGhosh. Not that I have many, but it's the first scope I bought. It'll be my #1 until it dies.

  • @ianmacpherson8385
    @ianmacpherson8385 Před rokem +1

    I learn so much. Thank you.

  • @montynorth3009
    @montynorth3009 Před rokem

    The idle current is around 34 ma which equates to 7.5 mv across the 0.22 ohm resistors.

  • @metallitech
    @metallitech Před 2 měsíci

    Any difference in the soudn?

  • @rickjames6948
    @rickjames6948 Před 6 měsíci +1

    Where do you repair guys get the schematics from?

  • @ewhibs
    @ewhibs Před 7 měsíci

    Noob here, how do you know where to solder the other end of the jumper wires? Thx

    • @calebeecher8451
      @calebeecher8451 Před 6 měsíci +1

      So where your pad sits. It’s in what is called a trace. Think of it as a wire laying on the board. If you pause his video you can see what I’m saying.
      So all you need to do is connect a jumper from the leg of the component with the damaged pad to another leg in that same trace. If they are in the same trace they are already connected together.

    • @ewhibs
      @ewhibs Před 6 měsíci

      Thank you! Totally understand that now.@@calebeecher8451

  • @iblesbosuok
    @iblesbosuok Před rokem

    Small copper tube can be used to repair chipped solder pads.
    Cheers

    • @paulb4661
      @paulb4661 Před rokem +1

      you can also get actual vias of differing sizes, look like a fine flanged tube, you take it through the hole and then press the ends together.

    • @dualityrepair4770
      @dualityrepair4770  Před rokem

      Good to know thank you. There’s always something to learn.