Customer Fired Other Company! Can I Figure This No Cooling Out?

Sdílet
Vložit
  • čas přidán 12. 09. 2024
  • In this video we take a look at a large Trane RTU that isn’t cooling properly. Another company couldn’t figure out and the customer threw them off the job! Can I figure it out? Let’s see…
    ​⁠ ‪@pisfinest660‬ email me jeffshvacadventures@gmail.com to claim your prize!
    Get your Mileseey TP2 camera here
    amzn.to/3YB5q9Q
    Check out these great tools I use on a daily basis! Use the links…SAVE SOME CASH!
    Guide Sensmart PC230 Thermal Camera
    amzn.to/4f6nz4U
    WisePro 1000v Insulated Screwdriver set: amzn.to/43nBUV6
    Avhrit Electric Pipe Cutter amzn.to/4e6YDKb
    Discount code to save 10% : 104H1TFB
    TOPTES Combustible Gas Leak Detectors.
    4 TO CHOSE FROM!
    PT210S
    amzn.to/3QSHJEu
    Discount Code: GSYQFS4Z
    PT299
    amzn.to/3R38JlS
    Discount Code: 4A3HH88Q
    PT199
    amzn.to/3M5kTYs
    10% off with code: N83SX3Q6
    PT520B+ Professional Gas Leak Detector amzn.to/494fISD
    10% off with code: R98D8JH8
    TOPTES CT-300 CO Detector: amzn.to/499s23E
    Discount Code: 953OHRKL
    Get yourself a HIK Micro B20 Thermal Imaging Camera. Use this Link!
    amzn.to/3KwRw0m
    Inficon Gas-Mate Combustible Gas Leak Detector amzn.to/40ifEdL
    Tesman TN-213 NCV Tester amzn.to/3rVZY3j
    10% off with code: FJDYR4W3
    WisePro Tradesman Backpack:
    amzn.to/4912DYW
    If there are any other tools and products I use in my videos that interest you…just ask! I’ll get you a link!
    Support the Channel with a Super Thanks or
    PayPal: ​⁠@JeffsHVACAdventures
    CashApp: $JeffsHVACAdventures
    Venmo: @JeffsHVACAdventures
    Like and Subscribe!
    Questions, comments or to just say Hi, email me
    jeffshvacadventures@gmail.com

Komentáře • 296

  • @YTsux24-7
    @YTsux24-7 Před měsícem +86

    "I know it's old, I know it needs replaced, but if i can get seven more years out of it before i retire, I'd appreciate it, mang."
    Every time...

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před měsícem +11

      Spot on! Lol

    • @daeroc
      @daeroc Před 28 dny +8

      Sell their problems to someone else.

    • @bobshanery5152
      @bobshanery5152 Před 27 dny +1

      Hey if they want to pay to replace every part that fails then by all means.. Fact it is going to be cheaper in the long run to buy a new one is irrelevant. Waste money. Tech is not here to teach you about bad financial decisions.

    • @Herecomesthethruth
      @Herecomesthethruth Před 16 dny +1

      😂😂😂😂

    • @MindzEnt
      @MindzEnt Před 9 dny

      Yep, problem is these cheap ass business owners aren't about to pay 20,000 dollars for a new unit on a building they don't even know. They will make that shit last as long as possible.

  • @j.t.johnston3048
    @j.t.johnston3048 Před 18 dny +26

    The bad cap on the one fan motor kept it from starting properly. Once the other fan started, it was pulling air back through the other fan causing it to start pinwheeling backwards.

  • @VooDooV6
    @VooDooV6 Před 26 dny +11

    Been doing this for about 30yrs...we all can learn from one another...i learn something every day..

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 26 dny +3

      “Everydays a school day”
      Steve Lav

    • @heatingairservices8708
      @heatingairservices8708 Před 20 dny

      Amen Yes sir been in it since 1980 & lot charges & thats how ive tired kept up... call . ask read study what others have done ahead of me but to be Honest to me ...its getting way more complicated Than necessary save power bill but @ what costs

  • @brunonikodemski2420
    @brunonikodemski2420 Před 20 dny +19

    This is a good example of how induction motors work. In a two fan parallel system, if one fan starts, it will blow air back out of the other motor/fan. That can allow an induction motor to "run" without having to go through the normal high-current start, and since it is backwards, it will continue to run backwards. Usually this result in higher than normal current flow, so possibly might be diagnosed via a simple ampere check on each motor. This can also happen in synchronous motors, for various reasons, including phase reversal. Usually happens in "high efficiency" motors, due to their low slip-frequency designs.

  • @Joshuatimmons1783
    @Joshuatimmons1783 Před měsícem +86

    The reason the fan is running the wrong way is it probably wasn’t running at all the other fan was pulling air in through the other fan making it spin like it’s running backwards

    • @michaeldickson9501
      @michaeldickson9501 Před měsícem +6

      I was about to comment this myself!

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před měsícem +25

      That’s what happens most of the time. But this time, it was actually running backwards.

    • @TheGgin
      @TheGgin Před 29 dny +10

      ​@@JeffsHVACAdventures Nice save for the Tennant! You're correct the motor is running backwards, but when the run cap is dead, a PSC motor will run either direction it's spun with, in this case the working motor drew air down thru the guard as the comments above mentioned, both are right!

    • @throttlebottle5906
      @throttlebottle5906 Před 28 dny +4

      that can happen from a weak or bad capacitor also, it just needs a little help from the wind or other fan pulling through it, causing it to spin backwards.
      alternate, some tool put in the wrong rotation motor or has the reversing wires flipped.(now days, very likely!) 😬

    • @RAM4elightbars
      @RAM4elightbars Před 28 dny +6

      ​@@throttlebottle5906 Exactly... Basically The ambient airflow in the opposite direction takes the place of the capacitor and gives the blades a push start in the wrong direction.

  • @randomletters2948
    @randomletters2948 Před 17 dny +5

    Jeff,
    You can check the saturated temp of a standing system vs ambient temp and usually determine what refrigerant you have in the system.
    Shut off that circuit, equalize it and average the evap and cond entering air temps and compare it to your saturated temp for 22 and 407 to see which one it matches closest (as long as it’s close to fully charged).

  • @OShackHennessy
    @OShackHennessy Před 27 dny +24

    As a business owner I can understand the frustration when service companies recommend expensive repairs unnecessarily. More than once I’ve gotten second opinion and had units fixed for a few hundred instead of a few thousand and the repairs lasted. I also understand that inexperienced techs can make mistakes but perhaps they shouldn’t be the ones to condemn equipment and this wouldn’t happen. I do get both sides but when it’s my money I’m not throwing it away and the best man gets the job.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 27 dny +4

      Totally agree with you!

    • @brunonikodemski2420
      @brunonikodemski2420 Před 20 dny +4

      Totally agree. We had one company come out, crappy tech, they tried to sell us a complete whole system, which had only about 3000-hours refrig use on it. Second company diagnosed the problem, and fixed it for for 80-dollars, standard one-hour fee. It was only one bad wire connection. The tech probably spent about 15-minutes inside the system.

    • @heatingairservices8708
      @heatingairservices8708 Před 20 dny +5

      Right an Rookie should not condemn an unit yall been serviced or married too for years , call & send A seasoned tech to get em back going but senor tech in this case forgot to call to gain necessary the protocol to access the Roof & customer blew up ..but sure theres more to the story Customer already had something this One thing dint end years of trust but broke the camels back n my opinion either way new customer & hes impressed greatly & hey that how we survive in this business being the best we can Be

  • @Hvacguy1990
    @Hvacguy1990 Před 19 dny +5

    Bro I do residential but and the hand over the fan is spot on 😂

  • @doogie812
    @doogie812 Před 28 dny +16

    You said the key thing. 'If I don't know I had to call for help.' That is what makes you one of the good ones. Today there are a lot more people that would blow smoke up your ass than call for help.

    • @senffabrik4903
      @senffabrik4903 Před 19 dny +1

      true, sometimes the thing is a simple information you didn't have prior.

  • @Gary-ts6dh
    @Gary-ts6dh Před 6 dny +1

    6:41 - A bad capacitor will definitely cause the fan to run backward. Sometimes the AC would work at my tenant's home and sometimes it wouldn't. I asked her to contact me immediately when it wasn't working. She called and I asked her to turn the thermostat down so it would run till I got there (I was ten minutes away). Sure enough, the fan was running backward. I replace the dual run (30/5) and, Viola! Fixed. It's still operating after three years.

    • @josephkostinko739
      @josephkostinko739 Před 6 dny

      A blown fuse for 1 of the 3 phases could also make a fan run backwards. Had a bad motor master make one spin backwards too.

  • @tomh3652
    @tomh3652 Před 19 dny +3

    Some companies you just cant trust. The one that came to my house to check my 21 year old Trane 3 ton unit told me it could not be fixed. But the next company showed up found a pin hole leak in the copper line fixed it in like an hour saved me from getting a new unit for now he said it could last a few more years.

  • @arthouston7361
    @arthouston7361 Před 23 dny +3

    I would definitely replace an aging Voyager now, because after January, he will only be able to get an A2L unit, and who knows what kinds of fun that will bring. It is good that the owner got mad, so those guys never have to worry about dealing with him again. For all we know, the other company did find the bad caps, but he was so mad that they didn't get as far as telling him that. One tip for you...I carry a bunch of the rounded brass schrader caps, and once I remove those antique hex caps that ruin the valve core opening, I replace the old caps with the new. HTH.

  • @michaeldice7459
    @michaeldice7459 Před 20 hodinami

    You can never know everything so learning something new is always a good idea

  • @lindawo1760
    @lindawo1760 Před měsícem +1

    Good job man ! I’m a landlord and really want to learn more about hvac, having troubles with hvac guys so many times. I learned st new from you today. Thank u!

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před měsícem

      Happy to help.

    • @johngatsby1473
      @johngatsby1473 Před 28 dny

      You can invest in the proper equipment, don't skimp, and either take classes or CZcams like there's nothing else to do...then hire tech to help monitor you on your first install. I paid a dude 750 to just watch me and he thought I was joking but it built my confidence and I've done 10 since and working on one right now.

    • @johngatsby1473
      @johngatsby1473 Před 28 dny

      Take classes, invest in the right equipment or lots and lots of CZcams. Nuts not that hard. Diagnosing faults is tougher and does require good sense and the ability to read the wiring diagrams.
      I've replaced 10 of my AC units so far and have 3 more to go this month to solve this years issues....but man once you see how little equipment costs...you will shit a brick

  • @aaronbrown3573
    @aaronbrown3573 Před měsícem +12

    I work service and repair subbed through property managers and I gotta say I tend to trust service companies more than the customer. Landlord , owner , manager whatever. The stuff I see from them I dont trust them. They have unrealistic expectations on their highly used equipment. That being said there are bad service companies out there too. If I'm at a job and I catch any flack from owner , manager whatever I'm out. On to the next one. Most of them treat us like crap. Constantly making us wait or not being there when they say. Idk. Just My experience.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před měsícem +2

      I’ve had plenty of bad ones too!

    • @TheKnifed
      @TheKnifed Před 28 dny +1

      I work hot side, commercial food service repair. There's plenty of times where I get accused of stuff but it turns out we have never been to their site before. Sometimes they're mad because they call us out for an oven and suddenly need six other things repaired and I don't have my EPA certification because I am strictly hot side. I had a guy yesterday asking me to put gasoline in his refrigerator, it was very difficult to explain to him that I am not licensed to put gas in refrigeration systems

    • @generatornoiseheavy_a6546
      @generatornoiseheavy_a6546 Před 25 dny +1

      Totally agree. The customers are the worse, big time liars. The other day I went on a call back and my coworker only worked on the 1st floor condenser and the client admitted that but the problem was with the 2nd floor air handler. It was a bad capacitor on an old unit. Replaced it and he didn’t want to pay. Walked away, checked the dispatch and his payment information was there, charged him before I even got back to the truck, lol.

  • @jameswilyard4781
    @jameswilyard4781 Před měsícem +7

    Built in the plant I retired from. Jim

  • @johnnygonzales3211
    @johnnygonzales3211 Před 19 dny

    Very nice to see people that really help you.

  • @davidnull5590
    @davidnull5590 Před 29 dny +1

    Nice work. It's always good to get new customers.

  • @GreyRockOne
    @GreyRockOne Před 10 dny

    Nice work! Have to admit, first time I've seen a fan motor spin wrong with a bad cap, they just usually stop with my experience. Thanks Jeff.

  • @TheHolyFlapjack
    @TheHolyFlapjack Před 24 dny +3

    I have this EXACT issue with a trane at one of my stores. Replaced the fan motor with an OEM motor, replaced the capacitor, and it would just randomly run backwards. Not every time, but sometimes I'll go up there to work on something else and the fan is running backwards. Have still to figure it out but I am definitely gonna try changing the capacitor even tho it tested good out of the box.

    • @arguedscarab7985
      @arguedscarab7985 Před 22 dny +1

      It's probably because the 3 phase motor is wired incorrectly. Swap 2 wires

    • @TheHolyFlapjack
      @TheHolyFlapjack Před 22 dny +1

      @@arguedscarab7985 it's a single phase motor and has a capacitor. What I also thought about was the fact that the fan may have never actually turned on and the backwards rotation was caused by the air being pulled through the condenser by the other fan.

    • @arguedscarab7985
      @arguedscarab7985 Před 22 dny

      @@TheHolyFlapjack Yeah that's probable

  • @musicnerd72
    @musicnerd72 Před 6 dny

    Went to school for HVAC back in early 90s.... ( Didn't finish unfortunately )... But that was one of the "common sense" things taught was check fan rotation! 👍

  • @benderjrowe3599
    @benderjrowe3599 Před 27 dny +1

    It's a trane. The second fan only starts at a certain time when pressure or temperature setting is reached.

  • @hvacslayer2929
    @hvacslayer2929 Před měsícem +4

    That bigger comp for sure has been changed out. New one is probably 407c. Took the 22 retro to 407c. Buttt at least add the damn sticker.

  • @Eddy63
    @Eddy63 Před měsícem +4

    Nice job & nice catch on the fans ... Thx

  • @MariosACandRefrigeration
    @MariosACandRefrigeration Před měsícem +89

    I would never take a customer like that,gets upset for showing up too early.wonder what he is going to say,when you tell him he needs 1500 of refrigerant.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 27 dny +30

      I guess he would just say no, which would be fine with me. And Too be fair, I didn’t know I was walking into all this when I first came out. I just thought I was a second opinion. Which we get a lot of. All this happened when I got on the job site. And you should always call the customer before showing up. Commercial or Residential

    • @OShackHennessy
      @OShackHennessy Před 27 dny +10

      His time is no less important than yours.

    • @earlestes8649
      @earlestes8649 Před 20 dny +5

      Not necessarily when you’re on the clock trying to make a buck, I’ve charged landlords for a trip charge when I get there nobody’s home

    • @user-ns3ys4kq6l
      @user-ns3ys4kq6l Před 19 dny +5

      No he didn't even call to say he was coming out. With this building there are certain protocols needed to get on the roof.
      Approvals are needed, and keys are required that he might not have and has to make arrangements to get.
      You should always call a customer and let them know when you are coming.

    • @user-ns3ys4kq6l
      @user-ns3ys4kq6l Před 19 dny +3

      ​@earlestes8649 yeah, and if you didn't call, that is on you. It is people like you that give the industry a bad name.

  • @Bobcat1950
    @Bobcat1950 Před 27 dny +11

    Who’s to say if a service HVAC company would lie about the maintenance of the unit. Why not squirt a little oil to help sell the need for a unit replacement. I learned along time ago to get a second opinion then award the contract based on that opinion. If the diagnosis is the same, the first tech gets the job. If not, I have a new Tech servicing my units. I always get the right to fire or terminate an agreement if not satisfied or disagree with the way the work is proceeding.

  • @danyonka3180
    @danyonka3180 Před měsícem +2

    Good man Jeff, i learned plenty from you in this video

  • @lakeshvac
    @lakeshvac Před 14 dny

    Looks like a good catch , out company when we do a replacement we strongly advise our guys to mark in several places of the newer refrigerant

  • @750kv8
    @750kv8 Před 16 dny

    "Life's goal: pet all the dogs" I'm not a dog person but I like that sticker in your van. 👍

  • @jeffherald260
    @jeffherald260 Před 19 dny +2

    Man i would be happy as hell if someone showed up on time much less early

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 19 dny +1

      Yea it's tough man. Your contractor should at least give you a time window tho.

  • @nomanjones4803
    @nomanjones4803 Před 7 dny

    I worked on a rooftop that a so-called pro replaced the fan 3 phase running backward, I switched two leads and it worked fine.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 6 dny

      Yup. I’ve went behind guys that have worse whole units backwards. lol.

  • @alejandromata825
    @alejandromata825 Před 12 dny

    If you don’t know what gas you have in a system or if it’s fractionated I would disconnect the compressors and run the unit fans only for 20-30 minutes letting the saturated temperature somewhat match ambient and the reference the pt chart.

  • @GaryM-n3g
    @GaryM-n3g Před 28 dny +1

    I just had that same exact problem on that exact Trane unit(r410), also, supply air fan pulley was worn knocking down the original CFM's, I adjusted it now she is purring!!!!!!!

  • @Wheel_Horse
    @Wheel_Horse Před 8 dny

    You did notice those charred yellow sleeves on those faston connectors on the back of the fuse holders, right ? Those connections either ARE or WERE getting very hot to do that. BAD CRIMP. Shoulda fixed that.

  • @UrbanXExplorer
    @UrbanXExplorer Před 18 dny

    As in every job, like when I used to work for time Warner as contractor that I was one of few that actually listened in training. Yea we called it cable camp..lol one week stay up in columbus Ohio all expenses paid, they actually had house inside a huge warehouse.. but I done it for over 9 yrs, but started getting to old to be climbing around in attics ..lol but I trained a lot of good techs actually out of a 100 I say 50 or so actually turned out to be our best techs.. I'm strictly by book.. and always told them over and over ... Cable one on one..use your meters on ope box outside where line coming from the tap on pole. Then check all outlets before anything else that way you can trace down which isn't good. No given you as a.c tech I'm sure you have that very first thing to check as in cable one on one that I learned now that your jobs one on one is to check out fans making sure its blowing out right. Now I'm gonna say this and I'm being honest.. I was almost a pea hair of going to havoc technical career center..lol swear I was.. I wished I have a long dam time ago..lol I have buddy his son started around time i took cable training and he's done got a huge log cabin home, a bunch of properties and after he came out of training he went straight to all Myers Square and removed condensers and relocated them when they started upgrading all they're stores.. but.. yea.. so yes as in any job specially yours, cable, and yea at steel mill I worked in middletown ohio of surroundings. But talking bout cable installs on business class modems, digi box's, and running arial drops rather from tap in front on pole to in back of homes which we call rear easement. I had guys call me as I was not only tech but field supervisor, had one call me and said, I can not get the MTA, (modem for phone&internet) first thing i asked him was, whats your signal levels? He got quiet so hanged up on him..not being mean it's just I knew he didn't check levels from outside ope box on house. Called me back said, why ya hang up. Again I said what's level's, mind you this guy was like everyday calling me for something he should've already known.. hung up again . Next time he called back I said reason why I done it is because Time Warner gave us brand new sweet ass meters with all the best applications for any kind of singles, noise levels, pro ber an pre bur for phone lines.. anyways.. he was like ahh man.. randy I'm sorry.. I said always number one before starting any job..another was if at anytime you go do phone job and they're keeping they're old number an we just after jobs done we call sprint they were ones that ported number over.. but yea.. get call from another..I hear in background house alarm going off.. right off I said, phone job huh..he was like how ya knew..I said then what is reason you calling me..again i told him whats the first thing you say right after you introduced yourself..( Do you have a house alarm) let me guess..you didnt .lol

  • @aday1637
    @aday1637 Před 28 dny +3

    I had a new install like this. It was on a dental office and complaints were the same. Some cooling but not enough. I did a heat load calculation and it was sized properly. Come to find out the accurator piston couldn't travel all the way through the cylinder due to a flaw in the metal. It would get stuck just short of the mating surface and allow more refrigerant to flow rather than meter. It was a bear to get to but I tore the unit down to access the piston, cut it out and replaced it with heat dissipation gel and wet rags. Had to install a line dryer as well and thorough vac. No one had been able to find the issue prior. Carrier sent me in to troubleshoot. Just a manufacturing fluke.

  • @robertgregory2618
    @robertgregory2618 Před 16 dny +1

    Ability Refrigerants sells R-22 still reasonable.

  • @ellkir1521
    @ellkir1521 Před 21 dnem

    Old units are tough sometimes because there is an old saying: "You touch it, You own it". Meaning if it stops working after you have been there, owner calls you up saying you broke it. I've done work for free because I tell them it's on the way out very soon. and still get a call back my work was terrible because now it doesn't work three months later. Sheesh.

  • @USA-GreedyMenOfNoIntegrity

    27 years in the business, I’ve never seen single fan condensers with the motor running backwards with bad cap. Now dual fans like you have on that unit, yes.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 21 dnem +1

      I’ve seen it 4 times total. Only one time was on a single fan Resi unit with a dual cap.

    • @USA-GreedyMenOfNoIntegrity
      @USA-GreedyMenOfNoIntegrity Před 21 dnem

      @@JeffsHVACAdventures probably caused from convection through the fan from the heat of the condenser. But definitely not the fan motor windings causing it.

  • @achong007
    @achong007 Před 15 dny +1

    You fixed it. What is not to like :)

  • @Craig-fl8jj
    @Craig-fl8jj Před 22 dny +11

    As an electrician i can honestly say the method of wiring on hvac is highly fcked up.

    • @Matt-wm1bf
      @Matt-wm1bf Před 6 dny

      As an electronics technician, I have to agree HVAC cable management and dressing is trash.

  • @alejandromata825
    @alejandromata825 Před 12 dny

    Just my experience here but whenever I have seen a single phase condenser fan spinning backwards they have always been old motors on the outs that have broken days later and had me back out. I don’t think it’s a capacitor problem, but rather a bad motor problem.
    An AC capacitor just like an AC power supply does not have a polarity, what might be happening is that a bad capacitor in one is taking slightly longer than the other fan to get it going and if the fan blades are spinning backwards when it does get the motor going it will continue to run in the direction it was spinning, kind of like when reexpansion gas in a scroll makes it run backwards after a quick power outage without a time delay. The problem is you can never tell how long that was going on for or what damage it may have caused in the motor.
    Also, I have hosed down old condenser coils and found them to be shot in spite of physically looking ok. I have seen corroded coil fins near the ocean that look like they are intact until you hit them with the hose or touch them with your finger and they flake right off.

  • @kraftzion
    @kraftzion Před 7 dny

    Filters, evap coil, belt? On that unit just divide the model by 12 for tonnage. So 17.5.

  • @46fd04
    @46fd04 Před 19 dny

    "...he's just tryin' to get by." Owner probably says that every summer LOL

  • @troyjackson3164
    @troyjackson3164 Před 18 dny +1

    Fan runs backwards because capacitor, 3 phase blown phase in electrical or motor. Motor off and air blowing by. Blown fuse. But partial blown motor. Phase reversed.

  • @Duke93720
    @Duke93720 Před 7 dny

    More and more now, companies no longer want to troubleshoot and repair units. They just want to replace immediately

  • @turboflush
    @turboflush Před 11 dny

    Carry a paint matker and right the refrigerant near service port save the next guy.

  • @r.traceypickens6390
    @r.traceypickens6390 Před 7 dny

    Did you remember to tie the condenser fan wiring up off the refrigerant lines? It just takes a little wear and heat to arc across the line and blow the charge. That's a potential major catastrophe that has an easy fix.. ,

    • @mr.monitor.
      @mr.monitor. Před 7 dny

      Looks like it's been like that for a few years so far😅 it only takes a few seconds to tape and zip tie a few things in place but whoever is doing service there over the years obviously didn't care.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 6 dny

      I pulled them into the electrical compartment

  • @alejandromata825
    @alejandromata825 Před 12 dny

    Seeing the unit at the beginning of the video and listening to your introduction the first thing I would check is for an active heater counter acting the cooling. I had a call on an RTU throw me for a loop a long time ago as an apprentice. Is the the fan running backwards, or is it just spinning backwards off the other fans suction?

  • @FrostBlueFire
    @FrostBlueFire Před 28 dny

    I dont think they used R407C, it might be a dirty evap coil, but it's hard to say. Good catches on the CFMs, two things always circle my head when I see a motor spinning backwards, no power to motor or bad cap. They were probably intermittent and caused higher head pressure and lack of proper cooling. I feel there could be a restriction in the system possibly. Great vid, good work, those voyagers can be "fun" lol

  • @Dana-rz2ct
    @Dana-rz2ct Před 14 dny

    The one issue I saw was the motor wires still hanging on the piping. The next problem will be a hole in the pipe because of a wire shorting to it. I love wire ties.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 13 dny

      I pulled them into the electrical compartment. Just didn’t get it on film.

  • @roneckler9937
    @roneckler9937 Před 24 dny

    If you work on 3 phase systems, I would get a phase rotation meter. The other thing you could do is change the A and B phase on contactor to get the rotation correct.

    • @yngndrw.
      @yngndrw. Před 21 dnem

      If it was a three-phase fan motor, I don't think it would need the capacitor.

    • @roneckler9937
      @roneckler9937 Před 21 dnem

      @yngndrw. the capacitor is there to give the motor a jump start. Yes, 3 phase motor still have capacitors. On a 3 phase system, the most important thing to keep track of is motor rotation. If the rotation is backwards then the phases need to be swapped around so the motor will run in the right direction. All 3 phase motors are stamped with a direction arrow next to the armature to ensure the direction is correct. Single phase, or as some say, 2 phase, doesn't matter in almost all cases. This tech did the right thing by testing the capacitor on the motor first. A bad capacitor will do weird things to a motor, including make it run backwards. I've been an electrician for over 30 years now, and have tested many motor capacitors, and repaired many. This tech did an excellent job for this cutomer.

    • @yngndrw.
      @yngndrw. Před 20 dny

      ​@@roneckler9937I'm a little confused. Do you mean when using a three phase motor from a single phase supply or a three phase motor from a three phase supply? You do of course need a capacitor when using one from a single phase supply to provide the extra leg and yes you could swap two wires to reverse it, but this unit has a three phase power supply available so I don't see why they wouldn't just power it from a native three phase supply in that case. I've never seen a three phase motor with a capacitor when it's powered from a three phase supply and I'm not even sure how you'd connect one in that case. The start capacitor is used with a single phase supply because there are dead spots in the sine wave, which are not there in a three phase supply. Of course if you have a three phase supply with a highly loaded motor, you may need to use a star delta starter but again there's no capacitor in that scenario.
      So from the above, logically we can say that this is a single phase motor (With a start winding) running from a single phase supply - As a three phase motor would have just used the three phase supply directly.
      I'm happy to learn something new if I'm wrong, but I just can't see how you'd connect a single start capacitor to a three phase motor across a three phase supply nor have I ever seen one like this in the wild.

  • @dogdiggingrj2089
    @dogdiggingrj2089 Před 24 dny

    If you can find information on unit compressor for what type freon , see if owner has records of service and see if it shows type freon used

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 24 dny

      Yea I asked him, he showed no record of Freon change. Of course he’s only owned the space for 3 years.

  • @TimSmith-yi9zv
    @TimSmith-yi9zv Před 21 dnem

    At the same time. Further you diagnoses by investigating the heat exchanger. Since you probably have your drill with you.

  • @onejohn2.26.
    @onejohn2.26. Před 7 dny

    I think I would have added some plastic guard for those wires that one over those pipes

  • @ronaldfortier3906
    @ronaldfortier3906 Před 19 dny +1

    Other CFM pulls air through causing to turn backwards

  • @CameronKettner
    @CameronKettner Před měsícem

    The relay disables one fan when the outdoor air temp sensor connected to the rtrm is below 60 degrees. Some times Ive seen the sensor fail and then the rtrm thinks its insanely cold out and never enables the second fan. The paint on the compressor and filter dryer is from the factory.

  • @engineer_07-present14
    @engineer_07-present14 Před 13 dny +2

    Imagine that, a customer knows it's junk but wants miracles . Craps on anyone who can't perform the miracle under his terms. Typical

  • @senffabrik4903
    @senffabrik4903 Před 19 dny

    You say, experienced, a simple lesson prior, came in handy. No need for experience, just knowledge: Look Hands here, Measure here like this.
    Done.

  • @justaperson8560
    @justaperson8560 Před 11 dny

    Wired backwards is first thing I thought

  • @bobflatman278
    @bobflatman278 Před 19 dny

    Wonder if a tech did an acid test to check the windings pn a compressor. Even done properly it can get messy. Seem s lot of oil spray

  • @Sleeperking05
    @Sleeperking05 Před 12 dny

    This guy seems trustworthy. Probably why he's an independent contractor.

  • @gallardo360
    @gallardo360 Před 25 dny

    put a delay on make for stage 2 compressor, if not a 2 stage cool thermostat

  • @landerverheyden1652
    @landerverheyden1652 Před 18 dny

    Normal motors can turn both ways just depends on the polarity but and other stuff depending if it's AC or DC but no idee if there is a other kind of motor

  • @gankstar2000
    @gankstar2000 Před 17 dny

    Well done; God bless!!!

  • @davidsanders6957
    @davidsanders6957 Před 24 dny

    You mean a "WRECK-NITION" !!!! LOL

  • @ThermalDynamicSevices
    @ThermalDynamicSevices Před měsícem +2

    The paint is factory called Glyptal enamel coating

  • @richardmoody9422
    @richardmoody9422 Před 23 dny

    In my experience trane doesn't use two different compressors suggesting y2 has been replaced. That much oil would warrant a better leak check method. And I'll bet no one split that condenser to clean it. A little too much guess work for my liking.

  • @sparkystevo1
    @sparkystevo1 Před 4 dny

    The worst wiring you will EVER find is in the HVAC industry. Also, be careful of the clients you take on

  • @stephengalvan7722
    @stephengalvan7722 Před 13 dny

    Y1/y2 jumped automatically turns 2nd stage cooling run 8 wire call it a day

  • @007jechu
    @007jechu Před 18 dny

    I had a contractor do that once it was puzzling to say the least

  • @zekenzy6486
    @zekenzy6486 Před měsícem

    Great video. Thank you for sharing

  • @CubbyTech
    @CubbyTech Před měsícem

    Hope you managed the wires! That just bugs me to no end!

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před měsícem

      Didn’t film it but I did. Pulled them into the electrical section and secured them.

  • @cthompson658
    @cthompson658 Před 28 dny +1

    How come you didn't ty wrap condenser fan motor wires up off the piping

  • @mike675n5
    @mike675n5 Před 16 dny

    What were the black n orange probes attached to the copper lines?
    Are those how you were checking the pressure digitally?

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 16 dny

      Yea.. Testo Bluetooth probes. Sends all the readings right to my phone.

    • @mike675n5
      @mike675n5 Před 15 dny

      @JeffsHVACAdventures nice! I been out of the game 15 years bc of a wreck. Quadriplegic now but i still help family w hvac issues.
      So do they replace connecting hoses unless need to add freon?

  • @captainron7904
    @captainron7904 Před 27 dny

    i still see lots of R22 units luckily i still have 3 bottles of R22 and boy do i charge a lot for it.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 27 dny

      We still have a bottle or two we keep at the shop. In a very rare case we might use it but ok Resi stuff, if it’s low enough to cause an issue, then I usually just remove what’s left, quick vac, and charge will all 422B.

  • @DavidSmith-qk9ok
    @DavidSmith-qk9ok Před 17 dny

    Nobody carries R-22 anymore! It’s too expensive. I swap everything to 407C.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 17 dny

      Yup. I use R-422B myself but I’ve used 407c and tried Bluon a few times.

  • @VooDooV6
    @VooDooV6 Před 26 dny

    ALWAYS CLEAN ANY OIL RESIDUE WITH SAFTY SOLVENT..CARB CLEANER...WHEN YOU COME BACK YOU WILL KNOW IF ITS LEAKING

  • @turboflush
    @turboflush Před 11 dny

    Sending out a sales guy is frustrating to a customer when some sort of actuall diag is needed. In this case.. sending a rookie that clearly hasnt had the needed training yet.

  • @bobbiac
    @bobbiac Před 21 dnem

    Phrases you don't want to hear from your technician.. "huh.. that's new.."

  • @mikemoseley8711
    @mikemoseley8711 Před měsícem +4

    17.5 tons

    • @jkmarshall3553
      @jkmarshall3553 Před měsícem +1

      Nice! How can you tell?

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před měsícem +1

      The math did add up to that but it seemed like such an obscure size didn’t think it was.

  • @dyslectische
    @dyslectische Před 19 dny

    That 3 wires are have tape on it ? That are blank coper cable for testing?

  • @Joseph-jt3vg
    @Joseph-jt3vg Před 20 dny

    Is that an electrical meter WITH a capacitor tester??? I don’t know how many they make just like it, amp draw clamp, auto current detect, but no cap tester/meter

  • @anthonymcdonald3167
    @anthonymcdonald3167 Před 23 dny

    If you do the right thing for people and you give give them the best service you possibly can you try to save them money everybody wants to save money That's how you make money that's how you get more customers be honest that's all honest man here loved your video thank you sir keep up the good work good things will happen to you ❤❤❤❤❤🎉🎉🎉🎉🎉

  • @BWIL2515
    @BWIL2515 Před 7 dny

    Any tech in the field should mark a changed refrigerant

  • @jrh86
    @jrh86 Před 29 dny +1

    Time after time after time here in the UK the so called senior service engineer is just a sales guy masquerading as a HVAC guy which just pisses everyone off and is without doubt the worst aspect of the job.

  • @heatingairservices8708

    Hand over the fan ...110 % yes sir 2 reason fan direction & is iT Discharging heat

  • @JackGore
    @JackGore Před měsícem +1

    What wireless gauges do you use?

  • @GMCGUY-
    @GMCGUY- Před 20 dny

    Why don't you carry that R22 refrigerant? You said that you don't carry it anymore. Our 21 or R22 refrigerant. I can't remember which you said. Do they not make it anymore?Or is it just harder to get????

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 20 dny

      It’s phased out. They starting phasing it out in 2009 with a complete cease production in 2020. It’s extremely expensive. They do make a replacement for it but it requires removing existing R22 before using it.

    • @GMCGUY-
      @GMCGUY- Před 20 dny

      @@JeffsHVACAdventures ahhhhh ok ok 👍 THANKS I AM NEW TO YOUR CHANNEL DEFINITELY HERE TO STAY. THANKS FOR LETING ME KNOW MUCH APPRECIATED MY FREIND THANKS AGAIN. LOOKING FORWARD TO AN OTHER VIDEO

    • @gettogo0159
      @gettogo0159 Před 15 dny

      @@JeffsHVACAdventures Not to blow your mind, you can get virgin gas from India direct shipped anything from R12/22/R134A/R290/410A/R600 etc No controls over there..... In US/Europe shouldn't have an issue. All the save the planet arh?? 🤣😂🤣😂😅🤣😂

  • @kyndred-ry5mm
    @kyndred-ry5mm Před 18 dny

    experience !!

  • @USA-GreedyMenOfNoIntegrity

    That unit was not cleaned recently. Did you see how nasty it was?

  • @Maniac742
    @Maniac742 Před 10 dny

    Someone replaced that fan and didn't bother to bring any zip ties? Those cost pennies.

  • @ShionWinkler
    @ShionWinkler Před 18 dny

    YCD211C3LACA, the 211 is the BTU's in 1000's so 211,000 BTU. Trane is normally 12,000 BTU per ton so 17.5 tons ish

  • @rc51price
    @rc51price Před 24 dny

    It wasn't running backwards. It wasn't running at all. Air vacuum from the other motor caused it to turn backwards

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 24 dny

      It was running backwards. I’ve Seen bad caps make single motor set ups run backwards too.

  • @drodriguez394
    @drodriguez394 Před 29 dny +5

    Bad cap doesn’t cause it to spin wrong, it doesn’t spin at all, and when the other fan starts up it sucks air through the other fan whole and that jump starts it and that’s what causes it to spin backwards

    • @paulmadsen51
      @paulmadsen51 Před 28 dny +1

      Makes perfect sense!

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Před 28 dny +4

      I’ve seen units with only one fan motor spin backwards with a bad capacitor.

    • @drodriguez394
      @drodriguez394 Před 27 dny +2

      @@JeffsHVACAdventures doesnt take much. you ever see a condenser fan motor free spinning while off because of the wind? now imagine that free spinning blade is spinning backwards. it has a bad cap and now it just got a call. boom you have a jumpstarted fan spinning backwards.

    • @russellshomestead3947
      @russellshomestead3947 Před 18 dny +1

      Get more experience in the feild if you haven’t seen a bad cap run it backwards rezi or commercial

  • @mr.monitor.
    @mr.monitor. Před 7 dny

    Did the other guy get hurt when he was thrown off the roof?

  • @yesdeere1376
    @yesdeere1376 Před 25 dny

    407c on a voyager? I’ve been out of the field for too long I guess

  • @openglpwr
    @openglpwr Před 18 dny

    Could tell by the video thumbnail it was bad capacitors

  • @qball6520
    @qball6520 Před 4 dny

    Sounds like a butcher-job by Coldstat Refrigeration from New Jersey 😂

  • @magchicago100
    @magchicago100 Před 19 dny

    ...you said a HVAC company recommended an expensive requirement of a new machine.....whoda thunk