Video není dostupné.
Omlouváme se.

WE INSTALLED A LAMP POST // TLF 57

Sdílet
Vložit
  • čas přidán 15. 09. 2023
  • In this video, Chris and Josh install a new lamp post next to the driveway improve the house's curb appeal and security. To supply electricity, they tap into the outdoor outlet installed in the last episode: • WE INSTALLED AN OUTDOO...
    ➤➤ Lamp Post 👉🏻 handydad.tv/qgza
    ➤➤ Post Light 👉🏻 handydad.tv/9g31
    ➤➤ Front Lights 👉🏻 handydad.tv/b4gw
    ➤➤ 12/2 UF-B Wire 👉🏻 handydad.tv/hja5
    ➤➤ GFCI/AFCI Tester 👉🏻 handydad.tv/gtst
    ➤➤ Grounding Wire Connector 👉🏻 handydad.tv/gnut
    ➤➤ Wago Connectors 👉🏻 handydad.tv/wago
    This is episode 57 of The Living Flip, a series where my daughter Julie and her husband Josh bought a foreclosure to fix up while they live there. Watch the whole series here:
    • The Living Flip
    DISCLAIMER:
    💳 - We purchased a product with our own money
    See handydad.tv/disclaimer for details.
    ☕️☕️☕️ If you liked this video, say thanks with a cup of coffee 👉🏻 ko-fi.com/handydadtv ☕️☕️☕️
    ✔︎Follow me on Facebook, Instagram and Twitter @HandyDadTV
    #thelivingflip #handydadtv #electricalg

Komentáře • 36

  • @arjunc2266
    @arjunc2266 Před 10 měsíci +3

    Beautiful!! Love to see all the hard work coming together!

  • @sewndebisdream6953
    @sewndebisdream6953 Před měsícem

    Beautiful! Thanks for the information.

  • @heidifritz3053
    @heidifritz3053 Před 10 měsíci

    Wow! The landscaping and pavers are beautiful…as is the lamppost!

  • @So_pho_king_awesome
    @So_pho_king_awesome Před 9 měsíci

    Congratulations, all the hard work is paying off. Looks beautiful.

  • @ridinwithricky6444
    @ridinwithricky6444 Před 10 měsíci

    Looks fantastic! Very nice addition! 👍🏼

  • @zekenzy6486
    @zekenzy6486 Před 10 měsíci

    Great Video. Thank you for sharing. It is nice and beautiful. Have a nice weekend

  • @phillyfathead
    @phillyfathead Před 10 měsíci

    Very well done!

  • @AndreasLenze
    @AndreasLenze Před 10 měsíci

    Well done!

  • @stanleykeith6969
    @stanleykeith6969 Před 8 měsíci

    Great Job.

  • @henrymcdonald870
    @henrymcdonald870 Před 6 měsíci

    Great job

  • @kbeast98
    @kbeast98 Před 10 měsíci

    Lamp post is sweet!

  • @notsure3448
    @notsure3448 Před 10 měsíci

    Would it be possible to put this on a switch in addition to using the light sensor if you wanted to turn it on when the sensor isn't activated?
    Would you have to wire it like a three way switch with the light sensor acting as the second switch? Or is there another way that I'm missing?

    • @handydadtv
      @handydadtv  Před 10 měsíci

      You could definitely wire it with a switch but not a 3-way. The switch wouldn’t override the light sensor.

  • @michaelsteinbach
    @michaelsteinbach Před 10 měsíci

    Should the conduit from the outlet into the ground be sealed so that insects don't make their way into that wall box?

    • @handydadtv
      @handydadtv  Před 10 měsíci +1

      I always leave it open, so water can escape down the bottom.

  • @Eric.Mercado
    @Eric.Mercado Před 6 měsíci

    I can’t believe you or they got rid of that gorgeous blue spruce! 😢 As well as some of the other mature specimens. Were they diseased or unhealthy?

  • @KeatonWarner1
    @KeatonWarner1 Před 10 měsíci

    👍

  • @secretagentbrewsky
    @secretagentbrewsky Před 5 měsíci

    do you have 15 amp outlets on a 20 amp circuit?

    • @handydadtv
      @handydadtv  Před 5 měsíci

      Yes. Nothing wrong with that. Just can’t put 20 amp outlets on a 15 amp circuit.

  • @ronnietruman7296
    @ronnietruman7296 Před 10 měsíci

    Direct burial cable must be 24 inches deep unless under concrete or in conduit per NEC section 300.5.
    18” if using pvc conduit and 6” if using rigid metal conduit.

    • @handydadtv
      @handydadtv  Před 10 měsíci

      True for non-GFCI circuits.

    • @handydadtv
      @handydadtv  Před 10 měsíci

      codes.iccsafe.org/s/IRC2015/chapter-38-wiring-methods/IRC2015-Pt08-Ch38-SecE3803.1#:~:text=For%20example%2C%20a%20120%2Dvolt,under%20the%20residential%20drive%2Dway.

    • @364gpwhite
      @364gpwhite Před 3 měsíci +1

      Look at column four, 12" for 120 volt GFCI protected branch circuit.